• 제목/요약/키워드: conventional curing

검색결과 268건 처리시간 0.024초

The polymerization rate and the degree of conversion of composite resins by different light sources

  • Ryoo, Joo-Hee;Kwon, Hyuk-Choon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.565-566
    • /
    • 2003
  • The clinical performance of light polymerized composite resins is greatly influenced by the quality of the light curing unit used. Commonly used halogen light curing units(LCUs) have some specific drawbacks such as decreasing light output with time. To overcome this, the blue LED LCUs are newly developed and introduced. The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue LED LCUs compared with conventional halogen LCUs.(omitted)

  • PDF

다중 집광성 UV-LED 경화형 코팅의 경화특성에 관한 연구 (A study on the curing characteristics of multi-concentrating UV-LED Curable Coating)

  • 정찬권;김범수;박대희
    • 한국산학기술학회논문지
    • /
    • 제19권10호
    • /
    • pp.339-345
    • /
    • 2018
  • 본 논문은 기존의 단일 파장의 UV(Ultraviolet: 자외선)-LED(Light-Emitting Diode) 경화형 코팅 방법과 달리 UV 파장에서 동작되는 LED를 중첩한 다중 집광성 UV-LED 경화형 코팅의 경화 특성에 대해 연구하였다. 각각 365nm, 395nm, 420nm, 450nm 단일 파장의 UV-LED 광원을 선정하여 광원의 광속, 지향각 등 광 특성을 분석하였으며, 또한 UV-LED 광원의 파장별 경화 특성에 대해 분석을 통하여 복합 파장에 대한 LED를 최적화를 진행하였다. 다파장 UV 광원이 중첩되었을 경우 경화 성능 상태를 전산모의 실험을 통해 예측하였으며 실제 설계 및 제작을 하였다. 내부 고속경화도 향상을 위해 각각의 LED를 집광시켜 동일한 위치에서 다파장이 합성, 집광되는 multi-spot 방식 모듈을 제작하여 파장 조합 조건을 달리하여 경화제의 접착력 및 표면, 내부 경화도를 실험하였다. 경도계와 FT-IR 분석 장비를 이용하여 표면 경화와 내부 경화 상태를 비교 분석하였다. 그 결과, 단일 파장보다 UV-LED 4파장을 중첩한 multi-spot방식이 표면 및 내부 경화도의 특성이 높아짐을 확인할 수 있었다.

치면열구전색제의 표면처리와 중합시간 증가에 따른 미반응 모노머 용리 평가 (MONOMER RELEASE FROM PIT AND FISSURE SEALANT FOLLOWING BY SURFACE TREATMENT AND CURING TIME)

  • 서현우
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.122-129
    • /
    • 2007
  • 본 연구는 복합 레진의 중합률에 영향을 미치는 광조사 시간을 달리하여 치면열구전색제를 중합하였을 경우 이로부터 용리되는 미반응 모노머들을 확인하고 정량화하고자 하였다. 그리고 치면열구전색제 중합 후 표면에 나타나는 미반응 모노머 층을 다양한 방법으로 제거한 후 용리되는 미반응 모노머들을 정량분석함으로써 미반응 모노머의 제거효과를 비교평가하고자 하였다. 광중합 시간에 따라 각각 20초, 40초, 60초간 중합한 후, 중합시간 별로 어떠한 처리도 시행하지 않은 군을 대조군, 증류수로 10초간 세척한 군을 I군(Group I), 75% 알콜에 젖은 면구로 10초간 문지른 군을 II군(Group II), 퍼미스와 러버컵을 이용하여 10초간 처리하고 증류수로 가볍게 세척한 군을 III군(Group III)으로 분류하였다. 표면처리 후 각 시편을 3차 증류수에 넣고 $37^{\circ}C$ 항온 수조에서 10분간 보관한 후 각각의 용리액을 고성능 액체 크로마토그래피를 이용하여 정성 및 정량 분석을 시행하였고 다음과 같은 결과를 얻었다. 1. 모든 대조군과 실험군에서 TEGDMA를 제외한 어떠한 모노머들도 검출되지 않았다. 2. 최소 중합시간, 권장 중합시간, 권장 중합시간 이상의 순으로 중합시간이 증가할수록 TEGDMA의 용리량은 감소하였다. 3. 표면처리를 한 군들은 대조군에 비하여 TEGDMA의 용리량이 유의할 만하게 감소하였다. 4. 표면처리를 한 군 가운데 퍼미스와 러버컵을 이용한 경우 잔존 모노머의 제거 효과가 다른 군에 비하여 유의성 있게 높았다. 5. 권장 중합시간 이상인 60초 중합 후, 퍼미스와 러버컵을 이용하여 표면처리한 경우 가장 적은 양의 모노머 용리량을 보였다.

  • PDF

Pontic Design에 따른 임시가공의치의 파절강도에 관한 연구 (FLEXURE STRENGTH OF ACRYLIC RESIN TEMPORARY BRIDGE BY PONTIC DESIGN)

  • 오상천;진태호;동진근
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.65-72
    • /
    • 1992
  • The purpose of this study was to evaluate the flexure stregth of posterior 4-unit acrylic resin bridge with different pontic designs : 1) Conventional pontic 2) Hygienic pontic and 3) Modified hygienic pontic. All specimens were made of self-curing acrylic resin for provisional restorations. Self-curing acrylic resin was filled in a silicone mold by the drop-on technique ; and was polymerized in a pressure spot under 20 psi pressure. The test specimens which were simply shaped posterior 4-unit bridge were 38mm ion 4mm wide, and 35mm thick(connector : 3mm thick). Each specimen was subjected to an increasing load of Instron machine with its tip centered on the specimen at 90-degree angle, and the machine was operated with its load cell of 50kg and its crosshead speed, 2mm/minute : and then the load values at the moment of the fracture of them were recorded. This study was also performed to analyze their stress distributions by the finite element method. The obtained results were as follows : 1. Flexure strength of the hygienic pontic(9.78kg) and the modified hygienic pontic(10.17kg) was higher than that of conventional pontic(6.96kg). But no significant difference was found between the hygienci pontic and the. modified hygienic pontic. The above statistic values were appraised by ANOVA and Duncan's multiple range test 2. Stress was concentrated on the middle portion in every group : and the stress of conventional pontic was found the greatest of all pontic designs.

  • PDF

OoA (Out-of-Autoclave) 프리프레그를 이용한 항공기용 복합재 일체형 부품 제작 및 평가 (Fabrication and Evaluation of Integrated Composite Part for Aircraft using OoA (Out-of-Autoclave) Prepreg)

  • 홍성진;송민환;송근일;백상문;신상준
    • Composites Research
    • /
    • 제29권5호
    • /
    • pp.315-320
    • /
    • 2016
  • 일반적으로 항공기 복합재 구조물은 고압의 오토클레이브(Autoclave)를 이용하여 제작하고 있으나 제작 가능한 크기가 제한적이고 고가라는 단점이 있다. 최근 전통적인 오토클레이브 공정을 대체하기 위해 Out-of-Autoclave(OoA) 공정에 대한 연구가 많이 이루어지고 있다. 최근에 개발된 OoA 프리프레그는 오븐에서 경화가 가능하기 때문에 장비 투자비와 경화 비용이 낮을 뿐만 아니라 오토클레이브 프리프레그와 유사한 품질을 나타내는 것으로 알려져 있다. 그러나 OoA 공정은 낮은 압력 때문에 복잡한 형상의 부품을 결함없이 제작하기는 매우 어렵다. 본 연구에서는 최신 OoA 프리프레그를 이용하여 Skin-Spar-Rib 일체형 복합재 부품을 제작하고 단면 관찰 결과를 통해 기존 오토클레이브 공정의 대체 가능성을 판단하고자 한다.

Shear strength behaviors of grouts under the blasting induced vibrations

  • Sagong, Myung;Choi, Il Yoon;Lee, Jun S.;Cho, Chung-sik
    • Geomechanics and Engineering
    • /
    • 제21권2호
    • /
    • pp.207-213
    • /
    • 2020
  • Umbrella Arch Method (UAM) often employed in the tunnel construction under poor rock mass conditions in Korea. Insertion of steel pipes at the periphery of the tunnel and infiltration of grouts along the pipes into the rock masses increases tunnel stability. There are two major effects of grouts expected at the tunnel face: 1) increase of face stability by enhancing the frictional resistance of discontinuities and 2) decrease of permeability along the rock masses. Increase of resistance and decrease of permeability requires a certain curing time for the grout. In Korea, we require 24 hours for curing of grout, which means no progress of excavation for 24 hours after infiltration of grouts. This step delays the tunnel construction sequences. To eliminate such inefficiency, we propose MTG (Method for Tunnel construction using Grouting technology), which uses extended length of steel pipes (14 m) compared to conventional pipe roof method (12 m). The merit of MTG is the reduction of curing time. Because of the approximately 2 m extension of the length of steel pipe, blasting can be done after infiltration of grouting. For this paper, we conducted experiments on the shear strength behaviors of grout infilled rock joint with elapsing of curing time and blasting induced vibration. The results show that blasting induced vibration under MTG does not influence the mechanical features of grout material, which indicates no influence on the mechanical behaviors of grout, contributing to the stability of tunnels during excavation. This result indicates that MTG is a cost effective and fast construction method for tunneling in Korea.

광원의 종류에 따른 복합레진의 중합거동 및 중합률에 관한 연구 (THE POLYMERIZATION RATE AND THE DEGREE OF CONVERSION OF COMPOSITE RESINS BY DIFFERENT LIGHT SOURCES)

  • 류주희;이인복;유현미;김미자;석창인;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.386-398
    • /
    • 2004
  • Objectives: The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue Light Emitting Diode Light Curing Units (LED LCUs) compared with conventional halogen LCUs. Materials and Methods: First, thermal analysis was performed by a differential scanning calorimeter (DSC). The LED LCU (Elipar Freelight, $320{\;}mW/\textrm{cm}^2$) and the conventional halogen LCU (XL3000, $400{\;}mV/\textrm{cm}^2$) were used in this study for curing three composite resins (SureFil, Z-250 and AEliteFLO). Second. the degree of conversion was obtained in the composite resins cured according to the above curing mode with a FTIR. Third, the measurements of depth of cure were carried out in accordance with ISO 4049 standards. Statistical analysis was performed by two-way ANOVA test at 95% levels of confidence and Duncan's procedure for multiple comparisons. Results: The heat of cure was not statistically different among the LCUs (p > 0.05). The composites cured by the LED (Exp) LCUs were statistically more slowly polymerized than by the halogen LCU and the LED (Std) LCU (p < 0.05). The composite resin groups cured by the LED (Exp) LCUs had significantly greater degree of conversion value than by the halogen LCU and the LED (Std) LCU (p =0.0002). The composite resin groups cured by the LED (Std) LCUs showed significantly greater depth of cure value than by the halogen LCU and the LED (Exp) LCU (p < 0.05).

광조사 방법에 따른 복합레진의 중합수축에 관한 연구 (A STUDY ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN ACCORDING TO VARIOUS LIGHT-CURING METHODS)

  • 권오진;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제30권1호
    • /
    • pp.102-109
    • /
    • 2003
  • 본 연구는 중합수축을 줄이기 위해 개발된 2단계 광조사법을 사용하여 복합레진의 중합시 발생하는 수축양상을 스트레인 게이지법(strain gauge method)으로 측정해 보고, 중합도의 비교를 위해 미세경도를 측정해 본 다음 이 결과를 기존의 광조사법과 비교해 보고자 하는 것이었다. 내경 6mm, 높이 2mm의 아크릴 주형에 복합레진인 $Z100^{TM}$(3M, USA)을 충전하였고 Curing light 2500(3M, USA)과 Elipar Highlight(ESPE, Germany)의 광조사기를 사용하였다. I 군은 광도가 $450mW/cm^2$인 Curing light 2500으로 40초간 광조사하였고, II 군은 광도가 $650mW/cm^2$인 Elipar Highlight로 40초간 광조사하였으며, III 군은 Elipar Highlight의 2단계 중합 방법을 이용하여 초기 10초간은 $150mW/cm^2$로, 나머지 30초간은 $650mW/cm^2$의 광도로 조사하였다. 스트레인 게이지법을 이용하여 광조사 후 1초 간격으로 10분간 선중합 수축률(linear polymerization shrinkage)을 측정한 다음 그래프로 분석하였고, 중합 1분 후와 10분 후의 선수축률을 측정하여 통계분석하였으며 미세경도기를 사용하여 중합 24시간 후의 각 군의 미세경도를 측정하여 통계분석하였다. 중합수축 양상을 관찰해 본 결과 각 군에서 모두 중합 초기에 일시적인 재료의 팽창을 나타내었고, 그 후 약 1분간은 수축량이 급격히 증가하다가 증가의 폭이 점차 감소하는 양상을 보였다. 전반적으로 2단계 광조사법을 사용한 III 군에서 수축률이 낮게 나타났다. 중합 후 1분과 10분에서의 선수축률을 비교해 본 결과 통상적인 광조사법을 사용한 I 군과 II 군에 비해 2단계 광조사법을 사용한 III군에서 유의하게 낮은 수축률을 나타내었다(p<0.05). 미세경도 측정결과 상면과 하면에서 모두 각 군간에 유의한 차이를 발견할 수 없었다.

  • PDF

레진 강화형 글라스아이오노머의 색 안정성에 관한 연구 (A STUDY ON THE COLOR STABILITY OF RESIN MODIFIED GLASS IONOMERS)

  • 구대회;이용근;손호현;임미겸
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.358-373
    • /
    • 1997
  • Resin modified glass ionomers were introduced in 1988 to overcome the problems of moisture sensitivity and low early mechanical strength of conventional glass ionomers and to maintain their clinical advantages. The purpose of this study was to evaluate the color stability of four resin modified glass ionomers(Fuji II LC, Vitremer, Dyract and VariGlass), one resin composite material(Z-100), and one conventional glass ionomer(GC Fuji II) under several conditions. These conditions were as follows: 1) before curing, 2) after curing, 3) after polishing, 4) after 500 thermocycling, 5) after 1,000 thermocycling, 6) after 1,500 thermocycling and 7) after 2,000 thermocycling. Three specimens of each material/shade combination were made. Materials were condensed into metal mold with a diameter of 10 mm and a thickness of 2.0 mm, and were pressed between glass plates. The material was polymerized using a light polymerizing unit(Visilux II, 3M, USA). After removal of excess, the surface was polished sequentially on wet sandpapers. A reflection spectrophotometer(Model TC-6FX, Tokyo Denshoku Co., Japan) was used to determine CIELAB coordinates($L^*,a^*$ and $b^*$) of each specimen. CIE standard illumination C was used as the light source. The results were as follows : 1. In comparing different shades of same material, CIELAB color difference(${\Delta}E^*$) value was not significantly different from each other(p>0.05). 2. CIELAB color difference(${\Delta}E^*$) values between after-curing and after-polishing were ranged from 5.53 to 27.08. These values were higher than those of other condition combinations. 3. CIELAB color difference(${\Delta}E^*$) values between before-thermocycling and after-thermocycling were ranged from 1.40 to 7.81. Despite the number of thermocycling increased, CIELAB color difference(${\Delta}E^*$) value was low. 4. The color stability of resin modified glass ionomers was more stable than that of conventional glass ionomers but less stable than that of Z100.

  • PDF

고성능 피막양생제 개발 및 나노물질의 분산방안 평가 (Development of High Performance Curing Agent and Effective Dispersion Method of Nanomaterials)

  • 손호정;유병현;이동규
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.230-236
    • /
    • 2019
  • 최근 콘크리트 품질과 관련된 이슈로 시멘트의 원가절감 및 잔골재의 품질저하로 인해 콘크리트 표면의 들뜸, 레이턴스의 과다로 인한 표면 스케일링 및 소성수축의 증가로 인한 균열발생 등의 표면품질 하자 발생사례가 지속적으로 증가되고 있으며, 사회적인 이슈로 인해 미세먼지 및 배기가스로 인한 환경문제를 해결하고자 도로구조물의 광촉매 적용이 시도되고 있다. 이에 본 연구에서는 현장에서 편리하게 적용될 수 있는 양생 방법 중 작업 속도 및 효율성에서 우수한 양생제를 개발하고자 하였으며, 이와 더불어 표면층의 광촉매 코팅을 위한 나노사이즈의 이산화티탄(TiO2)의 혼입 및 분산방안을 평가하여 광촉매 작용이 가능한 다기능성 피막양생제를 개발가능성을 검토하고자 하였다. 실험결과 실리콘계 및 실란계는 굳지않은 콘크리트 표면에서 신속하게 피막을 형성하는 성능을 보이기 때문으로 양생제로서의 원료로 검토를 진행하여 기존의 양생제보다 피막성능이 우수한 고성능 피막 양생제를 개발하였다. 나노물질의 적용을 위한 분산방안을 검토하기 위해 분산된 시료를 4주간 옥외폭로하여 분리유무를 통한 안정성을 평가한 결과 초음파 분산기의 성능이 가장 우수한 것으로 확인되었다.