• Title/Summary/Keyword: conventional cone

Search Result 187, Processing Time 0.025 seconds

Comparison of access window created by cervical ventral slot and modified slanted ventral slot in canine cadaver

  • Kang, Ho Young;Kang, Jinsu;Lee, Haebeom;Kim, Namsoo;Heo, Suyoung
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.3
    • /
    • pp.139-144
    • /
    • 2020
  • Ten cadavers were studied to compare the accessibility of cervical vertebral canal with conventional standard ventral slot and modified slanted ventral slot. One group performed standard ventral slot procedures at the C3-4, C5-6. The other group performed modified slanted ventral slot with inverted cone technique procedures at the C3-4, C5-6 computed tomography was performed before and after surgery. The accessibility of cervical vertebral canal with conventional standard ventral slot and modified slanted ventral slot using computed tomography in C3-4 and C5-6 intervertebral space was compared. Although smaller ostectomy was performed in the modified slanted ventral slot, some lesions were more accessible but limitations were obvious in C3-4 and C5-6 intervertebral disk space. After the disc material has been identified through accurate preoperative diagnostic imaging, less morbidity and complications can be expected if the appropriate surgical method is selected based on the lesion of compression.

Micro-computed tomographic evaluation of a new system for root canal filling using calcium silicate-based root canal sealers

  • Tanomaru-Filho, Mario;Torres, Fernanda Ferrari Esteves;Pinto, Jader Camilo;Santos-Junior, Airton Oliveira;Tavares, Karina Ines Medina Carita;Guerreiro-Tanomaru, Juliane Maria
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.34.1-34.7
    • /
    • 2020
  • Objectives: This study evaluated by using micro-computed tomography (micro-CT) the filling ability and sealer apical extrusion promoted by a new Sealer Injection System (SIS; Angelus) with side openings needle, in comparison with the conventional injection system, associated with a new ready-to-use calcium silicate-based sealer (Bio-C Sealer). Materials and Methods: Acrylic resin models containing a main curved artificial canal and 3 simulated lateral canals in apical, middle and cervical thirds were used. The main root canals were prepared using a rotary system up to size 35.05. The canals were filled with Bio-C sealer by using a single cone technique and the conventional delivery system or SIS. Samples were scanned in micro-CT. The percentage of voids throughout the entire extension of the main root canal and in each third of the lateral canals, besides the apical extrusion of the sealer was calculated. Data were submitted to t-test (p < 0.05). Results: There was no difference between both systems in the main root canals filling. Although the volume percentage of voids was similar in the apical and middle thirds of lateral canals, SIS had the greatest filling ability of the cervical third lateral canal. Moreover, the conventional system showed the highest apical extrusion of the sealer. Conclusions: The conventional and SIS obturation systems had an appropriate filling ability of the main root canal. SIS had the best filling of the cervical third of the lateral canals, besides lower sealer apical extrusion, suggesting its clinical indication.

3D Printed customized sports mouthguard (3D 프린터로 제작하는 마우스가드)

  • Ryu, Jae Jun;Lee, Soo Young
    • The Journal of the Korean dental association
    • /
    • v.58 no.11
    • /
    • pp.700-712
    • /
    • 2020
  • The conventional mouthguard fabrication process consists of elastomeric impression taking and followed gypsum model making is now into intraoral scanning and direct mouthguard 3D printing with an additive manufacturing process. Also, dental professionals can get various diagnostic data collection such as facial scans, cone-beam CT, jaw motion tracking, and intraoral scan data to superimpose them for making virtual patient datasets. To print mouthguards, dental CAD software allows dental professionals to design mouthguards with ease. This article shows how to make 3D printed mouthguard step by step.

  • PDF

Conventional Female Donor Costume of Cave 79 of Kumtura

  • Shenya, Shenyan
    • The International Journal of Costume Culture
    • /
    • v.12 no.2
    • /
    • pp.210-214
    • /
    • 2009
  • Cave 79 of Kumtura grottoes, is the best preserved cave, which has an important meaning for research on Uighur costume. This paper is intended to analyze the costume characteristics of female donors in Cave 79 by comparing image materials between Dunhuang murals and other murals in Xinjiang province. In Cave 79, female donor wears red robe with tight sleeve, whose collar is crescent-shaped decorated. Two different opinions are upheld for this decoration. One regards this as the turn-down collar, while the other believes this as decoration on V-neckline. Red robe is quite common in female donors of Xinjiang and Dunhuang murals and a female in fresco is wearing a crown in a triangle red headwear style, regarded as red silk and drooping at head. Female donors wear an extra coat, kame hair clasp, red jacket, light-colored high-waist skirt with a long-tail waistband, and tangerine Pibo (silk ribbon) with scattered small flowers. All these costume styles are commonly-used by Han females. The kame headwear is also the common ornament for Han females and the female's hairstyle is in cone shape on head by a white kame. Current costumes are similar but not completely same.

  • PDF

Digital Tomosynthesis using a Flat-panel Detector based Micro-CT

  • Mandai, Koushik Kanti;Choi, Jeong-Min;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.364-370
    • /
    • 2008
  • Recent development in large area flat-panel x-ray detector technology enables clinical application of digital tomosyntesis. Unlike conventional motion tomography using x-ray films, flat-panel x-ray detectors provide projection images in digital formats so that tomographic images can be synthesized in a more flexible way. For the digital tomosynthesis, precise movements of the x-ray source and the x-ray detector with respect to a fulcrum point are necessary. In this study, we apply the digital tomosynthesis technique to the flat-panel detector based micro-CT in which the flat-panel detector and the x-ray source rotate together on a circular arc. The experimental results suggest that flat-panel detector based 3D CTs can be used for digital tomosynthesis in the clinical environment.

DC Langmuir Probe for Measurement of Space Plasma: A Brief Review

  • Oyama, Koichiro
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.167-180
    • /
    • 2015
  • Herein, we discuss the in situ measurement of the electron temperature in the ionosphere/plasmasphere by means of DC Langmuir probes. Major instruments which have been reported are a conventional DC Langmuir probe, whose probe voltage is swept; a pulsed probe, which uses pulsed bias voltage; a rectification probe, which uses sinusoidal signal; and a resonance cone probe, which uses radio wave propagation. The content reviews past observations made with the instruments above. We also discuss technical factors that should be taken into account for reliable measurement, such as problems related to the contamination of electrodes and the satellite surface. Finally, we discuss research topics to be studied in the near future.

Generalized Schmertmann Equation for settlement estimation of shallow footings in saturated and unsaturated sands

  • Mohamed, Fathi M.O.;Vanapalli, Sai K.;Saatcioglu, Murat
    • Geomechanics and Engineering
    • /
    • v.5 no.4
    • /
    • pp.343-362
    • /
    • 2013
  • Simple relationships are proposed in this paper by modifying the Schmertmann's equation for settlement estimations of footings (i.e., $B/L{\approx}1$) carrying vertical loads in saturated and unsaturated sandy soils. The modified method is developed using model plate load tests (PLTs) and cone penetration tests (CPTs) results conducted in saturated and unsaturated sand in a controlled laboratory environment. Seven in-situ large-scale footings tested under both saturated and unsaturated conditions in sands were used to validate the proposed technique. The results of the study are encouraging as they provide reliable estimates of the settlement of shallow footings in both saturated and unsaturated sands using the conventional CPT results.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

Pulp revascularization with and without platelet-rich plasma in two anterior teeth with horizontal radicular fractures: a case report

  • Arango-Gomez, Edison;Nino-Barrera, Javier Laureano;Nino, Gustavo;Jordan, Freddy;Sossa-Rojas, Henry
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.35.1-35.10
    • /
    • 2019
  • Pulp revascularization is an alternative treatment in immature traumatized teeth with necrotic pulp. However, this procedure has not been reported in horizontal root fractures. This is a case report of a 9-year-old patient with multiple horizontal root fractures in 2 upper central incisors that were successfully treated with pulp revascularization. The patient presented for treatment 2 years after the initial trauma, and revascularization was attempted after the initial treatment with calcium hydroxide had failed. Prior to pulp revascularization, cone-beam computed tomography and autoradiograms demonstrated multiple horizontal fractures in the middle and apical thirds of the roots of the 2 affected teeth. Revascularization was performed in both teeth; platelet-rich plasma (PRP) was used in one tooth (#11) and the conventional method (blood clot) was used in the other tooth (#21). Clinical and radiographic follow-up over 4 years demonstrated pulp calcification in the PRP-treated tooth. Neither of the 2 teeth were lost, and the root canal calcification of tooth #11 was greater than that of tooth #21. This case suggests that PRP-based pulp revascularization may be an alternative for horizontal root fractures.

Uncertainty Analysis of Soft Ground Using Geostatistical Kriging Method (지구통계학 크리깅 기법을 이용한 연약지반의 불확실성 분석)

  • Yoon Gil-Lim;Lee Kang-Woon;Chae Young-Su
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.3
    • /
    • pp.5-17
    • /
    • 2005
  • Spatial uncertainty of Busan marine clay ground, which commonly occurs during site investigation testing, data analysis and transformation modeling, has been described. In this paper geotechnical uncertainty of shear strength indicator $N_k$ has been quantified in both horizontal direction and vertical direction using geostatistical Kriging method. Most of soil data used are from 25 boring tests, 75 laboratory tests, 124 field vane tests and 25 cone penetration tests (CPT). CPT-$N_k$ data for undrained shear strength determination, which are the most important properties in geotechnical design stages, have been analysed. Comparison between cone factor from conventional CPT-based method and that of geostatistical method shows that geostatistical Kriging method is an ideal tool to quantify the spatial variability of uncertainty from self-correlation of soil property of interest, and can be recommended to identify the spatial distribution of consolidation .md shear strength of soils at any sites concerned.