• 제목/요약/키워드: conventional cone

검색결과 187건 처리시간 0.031초

무인 착저식 해양 콘관입시험기 개발 (Development of Unmanned Seabed type Marine Cone Penetration Testing System)

  • 장인성;권오순;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.611-622
    • /
    • 2007
  • In the design and construction of the coastal/offshore structures, it is very important to evaluate the geotechnical characteristics of marine soils, which support the structures. Although the offshore site investigation is much more difficult than onshore, safe and precise jobs have not been accomplished in Korea because of the insufficiency of the test equipments especially for the site with deep water depth. The main objective of this study is to develop a new type of marine cone penetration testing(CPT) system, which can be utilized to even deep sea and high depth of soil layer. The system is one of seabed types and employs the conventional cone, which shows more reliable results than miniature cone. The most important parts of the marine CPT including continuous rod system, cone penetration system with wheel drive, automatic cone rod assembly/dissembly system etc., were designed and manufactured. Some tests to verify the developed marine CPT system were performed at both onshore and offshore sites as well as mechanical test in laboratory. The test results show the consistent and promising performance of the new equipment, and thereafter the system would be applicable to various sites with practical/economical advantages.

  • PDF

Cone beam CT와 일반 CT의 흡수선량 및 유효선량 비교평가 (Comparison of cone beam CT and conventional CT in absorbed and effective dose)

  • 김상연;한진우;박인우
    • Imaging Science in Dentistry
    • /
    • 제38권1호
    • /
    • pp.7-15
    • /
    • 2008
  • Purpose: This study provides comparative measurements of absorbed and effective doses for newly developed cone beam computed tomography (CT) in comparison with these doses for conventional CT. Materials and Methods: Thermoluminescent dosimeter rods (TLD rod: GR-200, Thermo Fisher Scientific Inc., Waltham, MA, USA) were placed at 25 sites throughout the layers of Male ART Head and Neck Phantom (Radiology Support Devices Inc., Long Beach, USA) for dosimetry. Implagraphy, DCT Pro (Vatech Co., Hwasung, Korea) units, SCT-6800TXL (Shimadzu Corp., Kyoto, Japan), and Crane x 3+(Soredex Orion Corp., Helsinki, Finland) were used for radiation exposures. Absorption doses were measured with Harshaw 3500TLD reader (Thermo Fisher Scientific Inc., Waltham, MA, USA). Radiation weighted doses and effective doses were measured and calculated by 2005 ICRP tissue weighting factors. Results: Absorbed doses in Rt. submandibular gland were 110.57 mGy for SCT 6800TXL (Implant), 24.56 mGy for SCT 6800TXL (3D), 22.39 mGy for Implagraphy 3, 7.19 mGy for DCT Pro, 5.96 mGy for Implagraphy 1, 0.70 mGy for Cranex 3+. Effective doses $(E_{2005draft)$ were 2.551 mSv for SCT 6800TXL (Implant), 1.272 mSv for SCT 6800TXL (3D), 0.598 mSv for Implagraphy 3, 0.428 mSv for DCT Pro and 0.146 mSv for Implagraphy 1. These are 108.6, 54.1, 25.5, 18.2 and 6.2 times greater than panoramic examination (Cranex 3+) doses (0.023mSv). Conclusion: Cone beam CT machines recently developed in Korea, showed lower effective doses than conventional CT. Cone beam CT provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology.

  • PDF

Comparison of conventional imaging techniques and CBCT for periodontal evaluation: A systematic review

  • Choi, Isabela Goulart Gil;Cortes, Arthur Rodriguez Gonzalez;Arita, Emiko Saito;Georgetti, Marco Antonio Pauperio
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.79-86
    • /
    • 2018
  • Purpose: This study aimed to carry out a systematic review of studies in the literature comparing conventional imaging techniques with cone-beam computed tomography in terms of the role of these techniques for assessing any of the following periodontal conditions and parameters: infrabony defects, furcation involvement, height of the alveolar bone crest, and the periodontal ligament space. Materials and Methods: Interventional and observational studies comparing conventional imaging techniques with cone-beam computed tomography were considered eligible for inclusion. The MEDLINE and Embase databases were searched for articles published through 2017. The PRISMA statement was followed during data assessment and extraction. Results: The search strategy yielded 351 publications. An initial screening of the publications was performed using abstracts and key words, and after the application of exclusion criteria, 13 studies were finally identified as eligible for review. Conclusion: These studies revealed cone-beam computed tomography to be the best imaging technique to assess infrabony defects, furcation lesions, the height of the alveolar bone crest, and the periodontal ligament space.

접촉 마찰을 고려한 다중 로봇 시스템의 조작도 해석 (Dynamic Manipulability for Cooperating Multiple Robot Systems with Frictional Contacts)

  • 변재민;이지홍
    • 전자공학회논문지SC
    • /
    • 제43권5호
    • /
    • pp.10-18
    • /
    • 2006
  • 본 논문에서는 다중 로봇 시스템에서 물체와 로봇 팔끝 간에 접촉 마찰이 존재할 때 이 로봇 시스템의 조작도를 해석하는 새로운 방법을 제안한다. 로봇이 물체를 떨어뜨리지 않고 잡고 있으려면, 로봇이 물체에 가하는 힘 벡터가 friction cone 내부에 존재 해야만 한다. 이러한 friction cone 내부를 나타내는 식은 일반적으로 비선형 형태로 되어 있기 때문에 기존의 조작도 분석 방법에 이 식을 구속 조건으로 적용하기가 쉽지 않다. 따라서 본 논문에서는 이러한 friction cone 내부를 다각뿔로 근사함으로써 선형적인 구속 조건으로 표현하였다. 또한 선행 연구에서 찾지 못했던 부분을 새롭게 찾아내었다. 그리고 다중 로봇 시스템에 조작도를 나타내는 물체 중심의 가속도를 구하기 위해서, 먼저 선형계획법을 통해서 허용 가능한 토크의 영역을 구하였다. 이 토크의 영역을 선형 변환을 통해 최종적으로 물체의 최대 가속도의 영역을 구하였다. 본 방법의 타당성을 입증하기 위해서 두 대로 구성 된 다중 로봇 시스템과 PUMA560 로봇 시스템에 적용하였다.

디지털 원추관입기 개발 (Development of a Digital Cone Index Measuring Device)

  • 이규승;이동훈;조용진;정선옥;박원엽;노광모;장영창
    • Journal of Biosystems Engineering
    • /
    • 제35권6호
    • /
    • pp.387-392
    • /
    • 2010
  • This study was performed to design and to construct a digital soil cone index(CI) measuring device replacing conventional analog type devices. The device developed in the study consisted of a load cell, a rotary encoder and a motor with a decelerator as its main parts. The cone speed was controlled lower than 3.0 m/s which keeps the standard suggested by the ASABE S313.3 specification. The experiment was conducted in a soil bin system as well as in various fields. The CI data measured by the developed device were compared with those by an existing measurement device(SC900, Spectrum, USA). Based on the experiments at various field conditions, the CI measuring characteristic of the device was quite similar to that of the conventional device within a acceptable $R^2$ range of more than 0.5(mean=0.76). It was concluded that the digital cone index measuring device was an effective and comprehensive sensor for measuring soil strength.

Cone beam computed tomography로 합성된 두부규격 방사선사진에서의 각 계측점의 정확도와 재현성에 관한 연구 (Accuracy and reproducibility of landmark of cone beam computed tomography (CT) synthesized cephalograms)

  • 권대근;민승기;전인철;팽준영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.78-86
    • /
    • 2010
  • Introduction: Cone beam computed tomography (CBCT) has various advantages and is used favorably in many fields in dentistry. Especially, CBCT is being used as basic diagnostic tool for 3-dimensional analysis in orthognathic patient. Two-dimensional cephalograms can be synthesized from CBCT digital imaging and communications in medicine (DICOM) data. In this study, conventional cephalograms and CBCT were taken simultaneously, and representative landmarks were located and analyzed in its accuracy and reproducibility. Materials and Methods: Ten patients who had orthognathic surgery in Wonkwang University Daejeon Dental Hospital participated in this study. For each patient, CBCT and conventional cephalogram was taken. By using Ondemand (Cybermad, Korea), 2-dimensional cephalograms was established on CBCT. In addition, 19 landmarks were designated and measured by 3 orthodontists twice a week. After these landmarks were transferred to a coordinate, distance of landmark and axis, standard error, distribution degree were measured, compared and analyzed. Results: Comparing the CT ceph group and conventional cephalogram group, CT ceph group had shown shorter distance of landmark and axis in S, Hinge axis, Bpt, Ba, Or, Corpus left. Standard error of the mean shows that CT ceph group has better reproducibility in Or, Corpus left, Hinge axis at X axis and Na, U1R, U1T, Bpt, PNS, Ba Corpus left, Hinge axis at Y axis. In both groups, mean error was less than 1.00 mm, no significant difference were found between CT ceph group and conventional cephalogram group in all measurements. Furthermore, comparing two groups, each 17 landmarks out of 19 had its characteristic in distribution degree. Conclusion: No significant difference were found between CBCT composed cephalographic radiograph and conventional cephalograghic radiograph, clinical application may be possible if improved.

Assessment of the role of cone beam computed sialography in diagnosing salivary gland lesions

  • Abdel-Wahed, Nagla'a;Amer, Maha E.;Abo-Taleb, Noha Saleh Mahmoud
    • Imaging Science in Dentistry
    • /
    • 제43권1호
    • /
    • pp.17-23
    • /
    • 2013
  • Purpose: The purpose of this study was to assess cone-beam computed (CBCT) sialography imaging in the detection of different changes associated with lesions of salivary glands. Materials and Methods: This study consisted of 8 cases with signs and symptoms from salivary gland lesions. Conventional sialography using digital panoramic and lateral oblique radiographs and CBCT sialography were performed for each subject. The radiographs were evaluated by 3 radiologists independently of each other. The results were compared between conventional sialography and CBCT sialography in the evaluation of various lesions associated with the salivary glands. Results: There was an agreement between the radiologists in interpreting the lesions that affected salivary glands with both techniques. The detection of the presence of stones or filling defects, stenosis, ductal evagination, dilatation, and space occupying lesions was 83% for conventional sialography compared with CBCT sialography. CBCT sialography was superior to conventional sialography in revealing stones, stenosis, and strictures, especially in the second and third order branches. Conclusion: It would be advisable to perform CBCT sialography in cases of obstructive salivary gland diseases for better demonstration of the ductal system of the gland.

고속 내면 연삭기 주축용 원추형 자기베어링 설계 연구 (Study on Design of Cone-Shaped Magnetic Bearing Spindle System for High Speed Internal Grinding)

  • 노승국;경진호;박종권;최언돈;양승준;이재응;김남용;이동주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.79-83
    • /
    • 2001
  • A cone-shaped active magnetic bearing spindle system for high speed internal grinding is designed and tested. The cone-shaped AMB system consists of only 4 couples of magnet, it can be smaller and lighter than conventional radial-axial-type AMB system. In this paper, the cone-shaped electromagnets are designed by magnetic circuit theory, and de-coupled direct feedback PID controller is applied to control the coupled magnetic bearings. The designed cone-shaped AMB spindle system is built and constructed with a digital control system, and tested its stbility and dynamic performances. As the results of the tests, this spindle runs up to 40,000 rpm with about 5 ${\mu}{\textrm}{m}$ of runout, and the AMB system provides high damping ratio eliminating overshoot and resonance speed.

  • PDF

개단 강관말뚝 내부 콘항타에 의한 지지력 증대효과 분석 (Analysis of Bearing Capacity Improvement Effect of Inner Cone Penetration Equiped Open-Ended Steel Pipe Pile)

  • 이준호;지수빈;이기철;김동욱
    • 한국지반신소재학회논문집
    • /
    • 제16권2호
    • /
    • pp.67-77
    • /
    • 2017
  • 본 연구에서는 콘 장비를 강관말뚝 중공에 설치함에 따른 말뚝의 거동을 분석하기 위해 축소 모형실험을 진행하였다. 콘 장비를 항타하여 설치 할 경우 먼저 강관 내부에 유입되는 관내토의 높이를 수치상으로 확인 할 수 있으며, 이를 통해 플러깅을 예측하여 플러깅에 따른 말뚝의 거동을 분석 할 수 있다. 또한 물리적인 항타 에너지로 지반의 강성과 강도를 증가 시켜 지지력을 상승 시킬 것으로 기대된다. 강사 장치를 이용하여 상대밀도 90%의 지반을 조성하고 거칠기가 다른 두 강관말뚝을 항타높이를 200mm와 500mm로 나누어 근입깊이 600mm까지 설치한다. 그리고 콘 장비의 유무에 따라 총 8가지 케이스를 나누어 말뚝의 지지력을 분석하였다. 말뚝의 항타높이, 말뚝의 거칠기, 콘 장비의 유무에 따른 세 가지 변수 중 항타높이가 약 70%로 지지력에 미치는 영향이 가장 컸으며 다음으로 콘 장비의 유무가 약 40%, 말뚝의 거칠기가 약 21%로 나타났다.

임상가를 위한 특집 1 - CBCT의 기본원리 및 적용 (Fundamentals and Applications of Cone-Beam Computed Tomography(CBCT))

  • 박인우
    • 대한치과의사협회지
    • /
    • 제50권4호
    • /
    • pp.180-188
    • /
    • 2012
  • Cone beam computed tomography(CBCT) machines recently developed in Korea, being designed for imaging hard tissues of the oral and maxillofacial region. I reported a brief overview of CBCT system, in comparison with coventional computed tomography(CT) system. CBCT provides high resolution, simpler image acquisition, lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology.