• Title/Summary/Keyword: convective conditions

Search Result 214, Processing Time 0.025 seconds

A Study on Thermohydrodynamic Turbulent Lubrication of High Speed Journal Bearing Considering Various Thermal Conditions on Walls (다양한 열전달 경계조건을 고려한 고속 저어널 베어링의 난류 열유체 윤활 연구)

  • 전상명;장시열
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.93-98
    • /
    • 2000
  • Turbulence on the journal bearing operation is examined. And the thermal variability is studied for isothermal, convective and adiabatic conditions on the walls within some degree of journal misalignment. An efficient algorithm for the solution of the coupled turbulent Reynolds and energy equations is used to examine the effects of the various factors. The calculation data of turbulent analysis are compared with the ones of laminar analysis. Heat convection is found to play but a small role in determining friction and load. The friction distribution patterns through inside a journal bearing now appear different with high values at the front part of the bearing due to the high speed and low temperature, and a sudden decrease past the pressure maximum.

  • PDF

A Study on Thermohydrodynamic Turbulent Lubrication of High Speed Journal Bearing Considering Thermal Conditions on Walls (열전달 경계조건을 고려한 고속 저어널 베어링의 난류 열유체 윤활 연구)

  • 전상명;장시열
    • Tribology and Lubricants
    • /
    • v.16 no.3
    • /
    • pp.208-217
    • /
    • 2000
  • Turbulence in journal bearing operation is examined and the thermal variability is studied for isothermal, convective and adiabatic conditions on the walls within some degree of journal misalignment. An efficient algorithm for the solution of the coupled turbulent Reynolds and energy equations is used to examine the effects of the various factors. The calculation data of turbulent analysis are compared with those of laminar analysis. Heat convection is found to play but a small role in determining friction and load. The friction distribution patterns through the journal bearing are now different with high values at the upstream region of the bearing due to the high speed and low temperature, and a sudden decrease past the pressure maximum.

Analysis of Thermal Comfort Factor′s Distribution in Convective Heating Space (대류난방공간에서 온열쾌적조건의 분포상태 분석에 관한 연구)

  • 공성훈
    • Journal of the Korean housing association
    • /
    • v.6 no.1
    • /
    • pp.31-37
    • /
    • 1995
  • The purpose of this study is to analyse the distribution of thermal sensation response and thermal environment condition in convective heating space. The contents of this study are as follows: 1)the spatial distributions of thermal conditions are measured 2)the thermal sensation vote of residents is taken in order to investigate the relation between thermal condition and human thermal sensation in sedentary condition 3)to analyse the distribution of subject's thermal sensation vote and thermal environment condition by two methods-regression method and graph method.

  • PDF

Water Sorption/Desorption Kinetics and Convective Drying of Eucalyptus globulus Wood

  • AMER, Mahyoub;KABOUCHI, Bousselham;El ALAMI, Salah;AZIZE, Brahim;RAHOUTI, Mohamed;FAMIRI, Abderrahim;FIDAH, Abdelwahed
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.557-566
    • /
    • 2019
  • Radial and tangential water diffusion in Eucalyptus globulus wood was investigated using three mature trees from a forest in Khemis Sahel (North Morocco). Absorption and desorption kinetics experiments were conducted at ambient temperature ($25^{\circ}C$) and $30^{\circ}C$, respectively, and a relative humidity of 60%. The diffusion coefficients in the two directions were determined under imposed hygrothermal conditions; they were greater in the radial direction for the absorption as well as desorption processes. Convective drying under load, preceded by reconditioning and followed up by balancing, revealed the drying conditions that corresponded to the appropriate drying schedules for E. globulus wood. This was verified by measuring the cracks and bowsbefore and after drying of boards.

FLASH FLOOD FORECASTING USING REMOTELY SENSED INFORMATION AND NEURAL NETWORKS PART II : MODEL APPLICATION

  • Kim, Gwang-seob;Lee, Jong-Seok
    • Water Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.123-134
    • /
    • 2002
  • A developed Quantitative Flood Forecasting (QFF) model was applied to the mid-Atlantic region of the United States. The model incorporated the evolving structure and frequency of intense weather systems of the study area for improved flood forecasting. Besides using radiosonde and rainfall data, the model also used the satellite-derived characteristics of storm systems such as tropical cyclones, mesoscale convective complex systems and convective cloud clusters associated with synoptic atmospheric conditions as Input. Here, we present results from the application of the Quantitative Flood Forecasting (QFF) model in 2 small watersheds along the leeward side of the Appalachian Mountains in the mid-Atlantic region. Threat scores consistently above 0.6 and close to 0.8 ∼ 0.9 were obtained fur 18 hour lead-time forecasts, and skill scores of at least 40% and up to 55 % were obtained.

  • PDF

Laminar Forced Convective Heat Transfer to Near-Critical Water in a Tube

  • Lee, Sang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1756-1766
    • /
    • 2003
  • Numerical modeling is carried out to investigate forced convective heat transfer to near-critical water in developing laminar flow through a circular tube. Due to large variations of thermo-physical properties such as density, specific heat, viscosity, and thermal conductivity near thermodynamic critical point, heat transfer characteristics show quite different behavior compared with pure forced convection. With flow acceleration along the tube unusual behavior of heat transfer coefficient and friction factor occurs when the fluid enthalpy passes through pseudocritical point of pressure in the tube. There is also a transition behavior from liquid-like phase to gas-like phase in the developing region. Numerical results with constant heat flux boundary conditions are obtained for reduced pressures from 1.09 to 1.99. Graphical results for velocity, temperature, and heat transfer coefficient with Stanton number are presented and analyzed.

Analysis for Air-Side Convective Heat Transfer Characteristics in Compact Heat Exchangers (밀집형 열교환기 내 공기 측 대류열전달특성)

  • Moh, Jeong-Hah;Lee, Sang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1443-1448
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchangers with continuous plate fins. Simulation results such as air flow and temperature distributions are presented, and heat transfer characteristics are compared for various inlet conditions. Results from various turbulence models are also compared for applicability. There is large difference between the local heat transfer coefficient distributions along the cylinder wall for circular tubes. Colburn j factors from the calculated results of circular and flat tubes in the heat exchangers are compared for various Reynolds number. The predicted results in this study can be applied to the optimal design of air conditioning system. with compact heat exchanger.

  • PDF

Proper Numerical Scheme to Solve the Flow Past a Circular Cylinder with Time and Grid Size Variations (시간과 격자 크기 변화에 따른 원주후류해석의 경제적 수치기법)

  • Maeng, Joo-Sung;Kim, Yong-Dae;Choi, IL-Kon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.652-659
    • /
    • 2000
  • The purpose of this study is to present the most effective numerical scheme to calculate the unsteady flows. In order to calculate the flow quantities of flow past a circular cylinder, Three-time level and five convective schemes are applied to unsteady and convective terms, respectively. The values obtained are compared with those from the existing experimental and numerical studies. At Reynolds numbers up to 160, time intervals can be expanded 10 times of Implicit Euler scheme using Three-time level method, and it is found that QUICK and CUI schemes work much stable than others even if less grid density conditions. The combination of Three-time level and QUICK scheme gives high resolutions for laminar unsteady problems with PC level.

An Analysis of Precipitation Systems Developed near Jeju Island in Korea during the Summer Monsoon, 2006

  • Jang, Sang-Min;Gu, Ji-Young;Lee, Dong-In;Jeong, Jong-Hoon;Park, Sung-Hwa;Uyeda, Hiroshi
    • Journal of the Korean earth science society
    • /
    • v.33 no.5
    • /
    • pp.377-394
    • /
    • 2012
  • To elucidate the mechanism associated with the development of heavy precipitation system, a field experiment was carried out in Jejudo (or Jeju Island) and Marado, Korea from 22 June to 12 July 2006. The synoptic atmospheric conditions were analyzed using the National Centers for Environmental Prediction-National Center for Atmospheric Research's (NCEP/NCAR) reanalyzed data, weather maps, and sounding data. The kinematic characteristics of each precipitation system were investigated by dual Doppler radar analysis. During the field experiment, data of four precipitation events with more than 20 mm rainfall were collected. In F case (frontal precipitation), a typical Changma front was dominant and the observation field was fully saturated. However there was no convective instability near the surface. LF case (low pressure accompanied with Changma front) showed strong convective instability near the surface, while a strong convergence corresponded to the low pressure from China accompanied with Changma front. In FT case (Changma front indirectly influenced by typhoon), the presence of a convective instability indicated the transport of near surface, strong additional moisture from the typhoon 'EWINIAR'. The convergence wind field was ground to be located at a low level. The convective instability was not significant in T case (precipitation of the typhoon 'EWINIAR'), since the typhoon passed through Jejudo and the Changma front was disappeared toward the northeastern region of the Korean peninsula. The kinematic (convergence and divergence) characteristics of wind fields, convective instability, and additional moisture inflow played important roles in the formation and development of heavy precipitation.

Combustion Instability and Active Control in a Dump Combustor (덤프 연소기에서의 연소불안정과 능동제어에 대한 연구)

  • Ahn Kyu-Bok;Yu Kenneth;Yoon Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.445-449
    • /
    • 2005
  • The mixed acoustic-convective mode combustion instability and the possibility of combustion control using a loudspeaker to these instabilities were studied. By changing inlet velocity, combustor length and equivalence ratio, the dynamic pressure signals and the flame structures were simultaneously taken. The results showed that as the combustor length increased and the inlet velocity decreased, the instability frequency decreased and the maximum power spectral densities of the dynamic pressures generally decreased. The instability frequency could be affected by an equivalence ratio over the operating conditions. From the data of close-loop control, as the loudspeaker may work out-of-phase with the natural instability, the optimum time-delay controller was confirmed to be able to reduce the vortex shedding from the mixed acoustic-convective mode combustion instability.

  • PDF