• Title/Summary/Keyword: controlled switching

Search Result 626, Processing Time 0.038 seconds

A Harmonic Elimination Method of PWM Inverter Using Walsh-Fourier Transform (Walsh-Fourier 변환을 사용한 PWM 인버어터의 고조파 제거 방법)

  • Ahn, Doo-Soo;Won, Chung-Yuen;Lee, Hae-Ki;Kim, Tae-Hoon;Kim, Hack-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.296-300
    • /
    • 1989
  • The paper proposes a method to eliminate harmonics of PWM inverter fed induction motor system using Walsh series. In other words, this paper presents technique of the selective harmonics elimination(SHE) by W-FT series in three phase PWM inverter output waveform. A microprocessor(8086 CPU) - controlled three phase induction motor system in order to verify this algorithm is present. It is designed for a three output voltage in the 1$\sim$60 Hz inverter with the 5th and 7th harmonics, 5th, 7th, 11th, and 13th, harmonics eliminated, and with the fundamental wave amplitude proportional to the output frequency. In the PWM inverter, dead time circuit is inserted in the switching si gnats to prevent the de link shortage. This paper is deals with quantative prediction of dead-time effect and its compensation in PWM inverters. The performance of the compensation circuits is confirmed by the experiment.

  • PDF

A Study On Parameter Compensation Scheme in Vector Controlled Induction Motor Drive (벡터제어 유도전동기 구동의 파라메터 보상에 대한 연구)

  • Park, Min-Ho;Kim, Young-Real;Won, Chung-Yuen;Kim, Tae-Hoon;Kim, Yuen-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.20-24
    • /
    • 1989
  • The time optimal position control scheme can be repeatedly taken from the initial state of a dynamic system to a desired one as fast as possible at the industrial drives. In this case, the machine parameters will vary due to temperature, frequency, and saturation effects. In particular, the rotor resistance value changes dramatically with temperature and frequency. These changes affect the command values of the stator current components and slip speed. There is a mismatch between the commanded variables and actual variables of the induction motor drive, and this situation leads to decoupling of the vector controller from the plant, i.e the induction motor. Consequences of such decoupling include the initiation of oscillations of the rotor flux and unsuitable switching of electromagnetic torque of the induction motor servo drive. Therefore, a rotor resistance parameter compensating method for the induction motor is described.

  • PDF

A Study on the Output Characteristics of AC Chopper Duty-Ratio $CO_2$ Laser System using 3 Electrode-type and Ring Blower (AC Chopper 3전극 방식의 듀티비에 따른 $CO_2$ 레이저 출력 특성에 관한 연구)

  • Park, Sung-Joon;Chung, Hyun-Ju;Kim, Geun-Yong;Lee, Yoo-Su;Kim, Whi-Young;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1697-1699
    • /
    • 2001
  • In this paper, the circuit of AC Choppers for $CO_2$ laser power supply are proposed and investigated. IGBT-controlled ac voltage regulators, operating at high frequency chopping mode. Chopping-to-supply duty ratio plays an important role in terms of laser output. Laser input energy is varied by controlling the leakage transformer used with the proposed system. This improved circuit employs a 3 electrode - type and Ring Blower. This improved circuit system has many advantages compared with the conventional SMPS such as simple design requirement, easy implementation, high reliability, low switching loss, and consequently high efficiency. As a result, the maximun output was 16W at duty-ratio of 92%, total gas mixture of $CO_2$ : $N_2$ : He = 1 : 9 : 15, total pressure of 15torr.

  • PDF

Economic Feasibility Study for Peak Load Control (최대부하제어(最大負荷制御)의 경제적(經濟的) 타당성(妥當性) 검토(檢討))

  • Yu, Sung-Chul;Yoon, Kap-Koo;Cho, Soon-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.19-22
    • /
    • 1993
  • Demand side management (DSM) is the planning and implementation of those utility designed to influence customer use of electricity in ways that will produce desired changes in the utility's load shape. It is conspicuous that the peak load control of DSM is efficiently adopted. In this paper, the package type air conditioner(A/C) mounted radio controlled switch. During the summer of 1990 KEPCO conducted tests in Seoul areas to determine the economic feasibility of interrupting A/C units for short periods of time during peak load periods. These tests were performed between July 30 and September 20 and were limited to the hours of between 1 and 6 p.m. These tests indicated that each A/C contributes approximately 4.5kW to the system peak and can be switched off 10 minutes out of each 1/2 hour without causing the customer any discomfort. Switching each A/C off for 10 minutes out of each 1/2 hour results in a peak load demand reduction of one kW per unit.

  • PDF

A 1.62/2.7/5.4 Gbps Clock and Data Recovery Circuit for DisplayPort 1.2 with a single VCO

  • Seo, Jin-Cheol;Moon, Yong-Hwan;Seo, Joon-Hyup;Jang, Jae-Young;An, Taek-Joon;Kang, Jin-Ku
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.3
    • /
    • pp.185-192
    • /
    • 2013
  • In this paper, a clock and data recovery (CDR) circuit that supports triple data rates of 1.62, 2.7, and 5.4 Gbps for DisplayPort 1.2 standard is described. The proposed CDR circuit covers three different operating frequencies with a single VCO switching the operating frequency by the 3-bit digital code. The prototype chip has been designed and verified using a 65 nm CMOS technology. The recovered-clock jitter with the data rates of 1.62/2.7/5.4 Gbps at $2^{31}$-1 PRBS is measured to 7/5.6/4.7 $ps_{rms}$, respectively, while consuming 11 mW from a 1.2 V supply.

Efficient Transmission Mode Selection Scheme for MIMO-based WLANs

  • Thapa, Anup;Kwak, Kyung Sup;Shin, Seokjoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.7
    • /
    • pp.2365-2382
    • /
    • 2014
  • While single-user spatial multiplexing multiple-input multiple-output (SU-MIMO) allows spatially multiplexed data streams to be transmitted to one node at a time, multi-user spatial multiplexing MIMO (MU-MIMO) enables the simultaneous transmission to multiple nodes. However, if the transmission time required to send packets to each node varies considerably, MU-MIMO may fail to utilize the available MIMO capacity to its full potential. The transmission time typically depends upon two factors: the link quality of the selected channel and the data length (packet size). To utilize the cumulative capacity of multiple channels in MIMO applications, the assignment of channels to each node should be controlled according to the measured channel quality or the transmission queue status of the node.A MAC protocol design that can switch between MU-MIMO and multiple SU-MIMO transmissions by considering the channel quality and queue status information prior to the actual data transmission (i.e., by exchanging control packets between transmitter and receiver pairs) could address such issues in a simple but in attractive way. In this study, we propose a new MAC protocol that is capable of performing such switching and thereby improve the system performance of very high throughput WLANs. The detailed performance analysis demonstrates that greater benefits can be obtained using the proposed scheme, as compared to conventional MU-MIMO transmission schemes.

Precise Control for Servo Systems Using Sliding Mode Observer and Controller (슬라이딩 모드 관측기와 제어기를 이용한 서보시스템의 정밀제어)

  • Han, Seong-Ik;Gong, Jun-Hui;Sin, Dae-Wang;Kim, Jong-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.154-162
    • /
    • 2002
  • The effect of nonlinear friction in the low velocity is dominant in precise controlled mechanisms and it is difficult to model. This paper is concerned with the compensation for friction using the variable structure system approach as nonmodel based method. The problem of chattering in the sliding mode controller is suppressed by the implementation of the boundary layer concept. And the estimation for friction using sliding mode observer makes the upper bound of matched uncertainty reduced. Accordingly, the effect of chattering can be more suppressed. And the sliding surface is constructed by adding an integral component to the switching function that is made by using error dynamics. This sliding surface guarantees the good tracking performance. Experimental results for a XY table system show that the proposed method has a good performance especially in the low velocity.

Analysis of Transient Characteristics of SFCL using the Three-Phase Transformer and Power Switch (삼상 변압기와 전력용 스위치를 이용한 초전도 한류기의 과도특성 해석)

  • Jung, Byung-Ik;Choi, Hyo-Sang;Park, Jung-Il;Cho, Geum-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1743-1747
    • /
    • 2012
  • The research of superconducting fault current limiter (SFCL) for reduction of the fault current is actively underway in the worldwide. In this paper, we analyzed the characteristics of a SFCL using the transformer and superconducting elements combined mutually in accordance with the fault types. The structure of this SFCL was composed of the secondary and third windings of a transformer connected to the load and the superconducting element, respectively. The provided electric power flew into the load connected to the secondary winding of the transformer in normal state. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the effect of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the current transformer(CT) and then turn-on and turn-off switching behavior of the secondary line in the transformer was performed by the silicon-controlled rectifier(SCR). As a result, the proposed SFCL limited the fault current within one-cycle efficiently. Also, the degradation of the superconducting element in the normal state was avoided.

Ultra fast Marx Generator of N2, SF6, N2-SF6 Mixture Gas based on Research Output Characteristics (초고속 Marx Generator의 N2, SF6, N2-SF6 혼합가스에 따른 출력 특성 연구)

  • Doo, Jin-Suk;Han, Seung-Moon;Huh, Chang-Su;Choi, Jin-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1850-1855
    • /
    • 2010
  • The application field of the pulse power is very wide. Recently, Pulse power technologies take a large place in several applications. Then, many civil and military applications proceed. Marx generator is widely used in high voltage applications. Marx generator is widely used in high voltage applications, such as eletromagnetic wave and power lasers. This paper, we described about the high voltage pulse generator. A compact size high voltage pulse generator with nanosecnd rise time has been fabricated and investigated experimentally. The marx generator has 2 stages. Each stage was constructed one charging capacitor, two electrodes and one charging resistor. A inductance structure is used in order to improve the switching performances fo the whole generator. The experiments of rise time in pure gas and mixtures of gases were described. We tested the Marx generator at different insulation gas. the results show that the dielectric strength of the $N_2-SF_6$ mixture was significantly increased compared with pure nitrogen gas. The experimental results show that the rise time characteristics of the Marx generator can be controlled through varying insulation gas.