• Title/Summary/Keyword: control vibration

Search Result 4,113, Processing Time 0.029 seconds

A Study of vibration Characteristics of Compressors with FEM model (유한요소 모델을 이용한 압축기의 진동특성에 관한 연구)

  • Ju, Jung-Ham;Hwang, Won-Gul;Choi, Gi-Seob;Ryu, Ki-O;SeoMoon, Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.967-971
    • /
    • 2004
  • Today, as the demands for home appliances are increasing, the understanding of noise and vibration characteristics have become more important. It is hard to control its vibration and noise characteristics, because its mechanical structure is very complex. In this study a model of reciprocating compressor is developed. Spring, frame, and LDT are modeled as flexible body, and the other parts are modeled as rigid. FEM model of frame is simplified in order to save the simulation time. We validated the simple model by comparing their natural frequencies and mode shapes. Motor torque is applied to a rotor, and the piston is subjected to a gas pressure. The vibrational characteristics of compressor is analyzed with LS-DYNA. Its results are compared with the simulation results of rigid body frame. The effect of LDT is also studied by comparing the vibration of frame with the results of simulation with no LDT.

  • PDF

Free Vibration of Arbitrary Shaped Arches (임의선형을 갖는 아치의 자유진동)

  • Lee, Tae-Eun;Shin, Seong-Cheol;Lee, Byoung-Koo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.526-529
    • /
    • 2004
  • Arches are one of the most important basic structural units as well as the beams, columns and plates. Most complicated structures consist of only these basic units and therefore it is very attractive research subject to analysis both the static and dynamic behavior of such units including the arches. This study deals with the free vibration of arbitrary shaped arches. In order to obtain the exactly arch shape, which surveyed (x, y) of neutral axis of arbitrary shaped arches are compared to various shape of arch: circular, parabolic, sinusoidal, elliptic, spiral and cartenary. The differential equations governing free vibrations of arches are merely adopted in the open literature rather than deriving the equations in this study. The Taylor series method is used as the numerical differential scheme. The Runge-Kutta method and the Regula-Falsi method, respectively, are used to integrate the governing differential equations and to compute the natural frequencies It is expected that results obtained herein can be practically utilized in the fields of vibration control.

  • PDF

The source identification of noise & vibration using characteristics of vibro-acoustic transmission (진동-음향 전달특성을 이용한 진동 및 소음원의 규명)

  • Oh, Jae-Eung;Kim, Dong-Sup;Kim, Woo-Taek;Kang, Hyun-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.495-499
    • /
    • 2000
  • The booming noise of a vehicle is usually caused by the vibration of the vehicle's body transmitted from the engine through the mounting system. Thus the engine mounting system must be cautiously designed to reduce the noise. Vector synthesis analysis is performed to predict the booming noise when the characteristic of the engine mounting system is changed., i.e., when magnitudes and phases of vibratory forces after the mounts are altered. To effectively use the method, the concept of 'effectiveness' is introduced to identify the contributions of each vibration sources and transmission paths to interior noise. When the magnitudes and phases of the forces due to the engine vibration are changed, the synthesized interior booming noise level is predicted by the vector synthesis diagram. Thus, the optimum characteristics of the forces are obtained through the simulations of the vector synthesis analysis. It is shown that the vector synthesis method can be used to obtain the optimum design characteristic of the mounting system to control the interior booming noise of a vehicle.

  • PDF

Application of Strain Energy for Determining the Location of Damping Material (스트레인 에너지를 이용한 제진재 위치 결정)

  • Kim, Joong-Bae;Ryu, Kuk-Hyun;Park, Sang-Kyu;Lee, Sang-Jo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.11
    • /
    • pp.1199-1205
    • /
    • 2008
  • The vehicle design engineers have studied the method of applying damping materials to the vehicle bodies by computer simulations and experimental methods in order to improve the vibration and noise characteristics of the vehicles. The unconstrained layer damping, being concerned with this study, has two layers(base layer and damping layer) and proyides vibration control of the base layer through extensional damping. Generally this kind of surface damping method is effectively used in reducing structural vibration at frequencies beyond 150Hz. The most important thing is how to apply damping treatment with respect to location and size of the damping material. To solve these problems, the current experimental methods have technical limits which are cumbersome, time consuming, and expensive. This Paper proposes a method based on finite element method and it employes averaged ESE(element strain energy) percent of total of dash panel assembly for 1/1 octave band frequency range by MSC/NASTRAN. The regions of high ESE percent of total are selected as proposed location of damping treatment. The effect of damping treatment is analyzed by comparing the frequency response function of the SPCC bare Panel and the damping treated panels.

An Experimental Study on the Vibration Response Characteristics of Floating Floor Systems for Heavyweight Impact Noise Reduction. (바닥충격음 차단을 위한 뜬바닥 구조의 진동응답특성에 관한 실험적 연구)

  • Choi, Kyung-Suk;Seok, Won-Kyun;Mauk, Ji-Wook;Shin, Yi-Seop;Kim, Hyung-Joon;Kim, Jeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.227-228
    • /
    • 2023
  • A floating floor generally consists of mortar bed separated from the structural RC slab by a continuous resilient layer. It is known that the floating floors are a type of vibration-isolation system to improve the impact sound insulation performance. However, some researchers have demonstrated that the amplification of vibration response at a specific range of frequencies results in an increase in the impact sound level. This study carried out the forced vibration tests to obtain the frequency response function (FRF) of a floating floor compared with a bare RC slab. Test results shows that the additional peak occur in vibrational spectrum of the floating floor except natural vibration modes of the bare RC slab. This is because the relatively flexible resilient material and mass of the mortar bed offer an additional degree of freedom in the structural system. Therefore, it could be efficient for reduction of floor impact vibration and noise to control the additional mode frequency and response of floating floors.

  • PDF

Feedback control strategies for active control of noise inside a 3-D vibro-acoustic cavity

  • Bagha, Ashok K.;Modak, Subodh V.
    • Smart Structures and Systems
    • /
    • v.20 no.3
    • /
    • pp.273-283
    • /
    • 2017
  • This paper presents and compares three feedback control strategies for active control of noise inside a 3-D vibro-acoustic cavity. These are a) control strategy based on direct output feedback (DOFB) b) control strategy based on linear quadratic regulator (LQR) to reduce structural vibrations and c) LQR control strategy with a weighting scheme based on structural-acoustic coupling coefficients. The first two strategies are indirect control strategies in which noise reduction is achieved through active vibration control (AVC), termed as AVC-DOFB and AVC-LQR respectively. The third direct strategy is based on active structural-acoustic control (ASAC). This strategy is an LQR based optimal control strategy in which the coupling between the various structural and the acoustic modes is used to design the controller. The strategy is termed as ASAC-LQR. A numerical model of a 3-D rectangular box cavity with a flexible plate (glued with piezoelectric patches) and with other five surfaces treated rigid is developed using finite element (FE) method. A single pair of collocated piezoelectric patches is used for sensing the vibrations and applying control forces on the structure. A comparison of frequency response function (FRF) of structural nodal acceleration, acoustic nodal pressure, and piezoelectric actuation voltage is carried out. It is found that the AVC-DOFB control strategy gives equal importance to all the modes. The AVC-LQR control strategy tries to consume the control effort to damp all the structural modes. It is seen that the ASAC-LQR control strategy utilizes the control effort more intelligently by adding higher damping to those structural modes that matter more for reducing the interior noise.

Vibration Control of a Robot Manipulator with a Parallel Drive Mechanism (평행구동방식 로봇 조작기의 진동제어)

  • 최승철;하영균;박영필
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2015-2025
    • /
    • 1991
  • A long and light-weight forearm of the vertical 2 DOF robot manipulator with a heavy payload driven by parallel drive mechanism is modelled as a Euler-Bernoulli beam with a tip mass subjected to a high speed rotation. Governing equation is obtained by Hamilton's principle and represented as state variable form using the perturbed variables which describe the perturbed errors at the manipulator's final configuration. Digitial optimal control and observer theory are used to suppress the forearm vibration and control the positions of the joint angles with measured/estimated state feedback. Computer simulations and experimental results are obtained and compared each other.

Structural vibration control using $H_{\infty}$ control theory : unceratinty model ($H_{\infty}$제어이론을 이용한 구조진동제어 - 불확실성 모델)

  • 송병석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.240-245
    • /
    • 1995
  • 제어이론의 역사적 발전사를 고찰해보면 1930년대부터 1960년대까지를 고전 제어(classical control) 시대로 분류되고 이때 주로 사용되었던 용어들은 주파수역(frequency domain)에서 사용된 개념인 극점(pole), 영점(zero), Nyquist, 근궤적(root-Locus) 선도(plot)등으로 대표된다. 그 다음단계인 현대 제어(modern control) 시대 (1960년대-1980년대)때는 새로운 개념들이 도입 되었는데 시간역(time domain)에서 사용되는 상태공간(state-space) 모델, 가제어성(controllability), 가관측성(observability), Kalman 필터, LQG 제어 등이다. 1980년대부터 현재까지를 강인제어(robust control) 시대로 분류하는데 이것의 특징들은 극점이나 영점 대신 상태공간 모델을 사용하여 주파수역에서 정의되는 개념들인 H$_{\infty}$ 합성법, .$\mu$ 해석법, LQG/LTR 및 QFT, Lyapunov 등으로 대표된다. 현대제어시대때는 제어기 K는 공칭 플랜트 모델 G$_{0}$를 기준으로 설계되었으나 실제로 공칭 플랜트 모델은 실제 플랜트와 항상 같을 수가 없었다. 따라서 실제 플랜트 G는 G=G$_{0}$ + .DELTA.G로 표현되며 여기서 .DELTA.G는 플랜트 불 확실성(plant uncertainty), 즉 실제 플랜트와 공칭 플랜트의 차이를 나타낸 다. 이 플랜트 불확실성은 제어기가 실제 응용되어 사용되었을 때 제대로 작동하지 않는 주요 이유중에 하나이다. 이와 같은 상황에서 안정도 강인성 (stability robustness) 및 성능 강인성(performance rosubtness)의 보장은 상 당히 중요한 문제로 대두되었으며 주어진 플랜트 불확실성하에서 이러한 강이성들이 보장되는 제어이론들 중 H$_{\infty}$ 제어이론이 많이 연구/응용 되고 있다. 특히 공칭 플랜트 모델과 함께 사용되는 플랜트 모델과 함께 사용되는 플랜트 불확실성 모델은 직접적으로 성능 및 안정도에 영향을 미치므로 주의 깊게 선정해야 한다.

  • PDF

Performance Evaluation of the Drift Control in Residential Tall Building Using the Dampers (제진장치를 적용한 초고층 주거형 건축물의 횡변위 제어 성능 평가)

  • Park, Ji-Hyeong;Kim, Tae-Ho;Kim, Ook-Jong;Lee, Do-Bum
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.265-273
    • /
    • 2008
  • The problem controlling lateral drift by the wind and the earthquake is very important in high rise buildings. But, outrigger system, generally used for residential tall buildings in Korea, has weak points with the occupancy of special space, the difficult construction and the long duration of works. On the other hand, the damper reduces story drifts of building structure by absorbing vibration energy induced by the dynamic loads and the application of damper systems is relatively simple. Also, the lateral drift control system such as outrigger system may raise the wind vibration problem of serviceability like human comfort and this problem may need another vibration control devices. Accordingly, we analyze the effect of the drift control using various dampers to substitute for outrigger system as the efficient system in residential tall buildings.

A Study of the Structural Vibration Control Using a Biaxial Tuned Mass Damper (2축 동조 질량 감쇠기를 이용한 구조물의 진동 제어 연구)

  • 정태영
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.473-481
    • /
    • 2000
  • Civil structures are becoming more flexible and lightly damped. When subjected to dynamic loads such as wind, earthquake and wave, vibration may be easily induced and lasted for lond duration. To suppress the wind-induced and earthquake-induced vibration of high-rise buildings, study on the development of a tuned mass damper has been carried out. Based on optimal design on passive tuned mass damper which is considered for a building subject to random excitations, a biaxial tuned mass damper was designed and developed. It is confirmed that the vibration levels of the test structure are reduced using the developed tuned mass damper.

  • PDF