• Title/Summary/Keyword: control vibration

Search Result 4,111, Processing Time 0.034 seconds

Semi-active vibration control using an MR damper (MR 댐퍼를 이용한 반능동식 진동 제어)

  • Jeon, Do-Yeong;Park, Chan-Ho;Yu, Jeong-Yeol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.1
    • /
    • pp.26-31
    • /
    • 1998
  • For the semiactive vibration control, a variable damper and proper control systems are essential. In this research, a controllable damper was designed using the MR fluids and its mechanical properties such as damping constant and response time were measured. Since the response time of the MR damper was much longer than nominal MR fluid response time, the time delay of the damper should be considered in the design of controllers. It is shown that the advanced On/Off vibration control which includes the damper time delay performs more effectively than the conventional one.

  • PDF

독립모달공간 제어기법에서 작동기 수의 절감에 대한 연구

  • 황재혁;김준수;박명호
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.273-279
    • /
    • 1997
  • Reduction of number of actuators for independent modal space control In this paper, a new modified independent modal space control (IMSC), which relaxes the fundamental hardware limitation of IMSC, is suggested to handle the vibration and attitude control problem for flexible large structures. This method has adapted a new switching algorithm between controlled modes and a novel design technique for modal control force. The main advantage of this method is to minimize the discontinuity of the modal control forces and to assure the asymptotic stability of the closed-loop systems. This process is shown to be simple and efficient in a realistic example of vibration control of a cantiloever beam. It has been found that the modified IMSC suggested in this paper, which can reduce the number of actuators, is highly excellent compared to other previous methods in terms of the performance and stability of the vibration control systems.

  • PDF

High-Speed Active Vibration Control System of Plate using TMS320C6713DSK (TMS320C6713DSK를 적용한 평판의 고속 능동 진동제어)

  • Choi, Hyeung-Sik;Her, Jae-Gwan;Seo, Hae-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.918-924
    • /
    • 2009
  • This paper deals with the experimental assessment of the vibration suppression of the smart structures. First, we have presented the paper about the new high-speed active control system that we have developed using the DSP320C6713 microprocessor and a peripheral system composed of a data acquisition system, A/D and D/A converters, piezoelectric (PZT) actuator/sensors, and drivers using PA95. Since fast data processing is very important in the active vibration control of the structures, we utilized the fast processing DSP320C6713 microprocessor as a main processor to the controller and fast peripheral devices for fast control loop. To realize a fast active vibration control, we have analyzed and tested the processing time of the peripheral devices and provided the corresponding test results. Especially, we have focused on achieving the fast signal amplification of the PA95 device since it takes most of loop times of the control system. Finally, we performed numerous experiments of active vibration control of the aluminum plate to validate the superior performance of the developed control system based on previous mode tests of the plate.

Development of ETMD for Improving TMD Control Performance (TMD 제어성능 개선을 위한 ETMD 개발)

  • Jeon, Seung gon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.157-164
    • /
    • 2022
  • The TMD has a simpler structure than other vibration control devices and shows excellent control performance for the standardized vibration occurring in the structure. However, when the vibration cycle of the structure coincides with the vibration cycle of the TMD due to the sudden external loads, the off-tuning occurs, which threatens the structure while increasing the vibration width of the TMD. Therefore, Electromagnetic Tuned Mass Damper (ETMD) was developed as a semi-active TMD that prevents off-tuning while exhibiting excellent control performance like TMD. To verify the control performance of the developed ETMD, the bending behavior control performance evaluation experiment using a simple beam bridge was performed. The experimental method compared the mutual control power by experimenting with the existing TMD method and the developed ETMD under nine excitation frequency conditions. As a result, it was confirmed that the control effect of ETMD was about 4.85% higher than that of TMD at 3.02Hz, which generates the maximum displacement in the simple beam bridge. Also, the off-tuning occurred in some excitation conditions when using TMD, although the off-tuning did not occur when using ETMD. Therefore, the excellent control performance of the ETMD developed in this study was verified.

Vibration Control and System Identification of Long Span Slab (대형 구조물 바닥판의 동적 거동 및 제어)

  • 황재승;김장윤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.56-59
    • /
    • 2003
  • As the slab is longer and lighter, it is more sensitive to the external force so that the vibration of slab and noise induced by the slab vibration is bigger than expected in normal slab. The purpose of this study is to investigate how the dynamic characteristic of slab is different from the normal slab through the system identification and tn evaluate the vibration control performance when the damper system is installed. Finally, we was trying to understand by what mechanism the slab noise is induced from the slab vibration. The relationship between the vibration and the noise of slab is shown by the numerical simulation.

  • PDF

Effects of Local Vibration on Knee Joint on Postural Control (슬관절에 대한 국소 진동 적용이 자세 조절 능력에 미치는 영향)

  • Park, Soo-Jin;Bang, Hyun-Soo;Choen, Song-Hee;Kang, Jong-Ho;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.195-203
    • /
    • 2007
  • Purpose : The purpose of this study was to evaluate the effects of local vibration on knee joints on ability of postural control. Methods : The subjects(50) were divided into control group(25) and vibration group(25). Vibration group was given vibration on knee joint for 10 minutes and control group was given resting for 10 minutes. All subjects of each group were tested on MFT balance tester board for 30 seconds and MFT Balance Test English 1.7 was used to measure ability of postural control pre and post test. Results : 1. Laterality didn't have statistically significant difference pre and post test in both groups(p<0.05). 2. In the control group Body stability didn't have significant difference pre and post test(p>0.05), but had significant difference in the vibration group(p<0.05). 3. At assessment Movement of COG, sector2 in the control group and sector 1, 5 in the experimental group had significant difference pre and post test(p<0.05). Conclusion : From this result vibration on knee have an effect on Body stability. Therefore, the vibration will be effective in treatment of patients who have disability of postural control.

  • PDF

Performance Estimation of Semi-active Real-time Feedback Vibration Control System (준능동형 실시간 Feedback 진동제어시스템의 성능평가)

  • Heo, Gwang Hee;Jeon, Joon Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.85-94
    • /
    • 2011
  • This paper is concerned to constitute a semi-active realtime feedback vibration control system and evaluate it through experiments in order to control in realtime the vibration externally generated, specially on the bridges which is structurally flexible. For the experiment of vibration control, we built a model bridge structure of Seohae Grand Bridge in a 1/200 reduced form and inflicted El-centro wave on the model structure also in a reduced force considering the lab condition. The externally excited vibration was to be controled by placing a shear type MR damper vertically on the center of bridge span, and the response (displacement and acceleration) of structure was to be acquired by placing LVDT and Accelerometer at the same time. As for the experiment concerning controlling vibration, a realtime feedback vibration control experiments were performed under each different condition largely such as un-control, passive on/off control, Lyapunov stability theory control, and Clipped-optimal control. Its control performance under different condition was quantitatively evaluated in terms of the peak absolute displacements, the peak absolute accelerations and the power required for control on the center of span. The results of experiments proved that the Lyapunov control and clipped-iptimal control were effective to decrease the displacement and acceleration of the structure, and also to decrease the power consumption to a great extent. Finally, the semi-active realtime feedback vibration control system constituted in this research was proven to be an effective way to control and manage the vibration generated on bridge structure.

Full-scale experimental verification on the vibration control of stay cable using optimally tuned MR damper

  • Huang, Hongwei;Liu, Jiangyun;Sun, Limin
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.1003-1021
    • /
    • 2015
  • MR dampers have been proposed for the control of cable vibration of cable-stayed bridge in recent years due to their high performance and low energy consumption. However, the highly nonlinear feature of MR dampers makes them difficult to be designed with efficient semi-active control algorithms. Simulation study has previously been carried out on the cable-MR damper system using a semi-active control algorithm derived based on the universal design curve of dampers and a bilinear mechanical model of the MR damper. This paper aims to verify the effectiveness of the MR damper for mitigating cable vibration through a full-scale experimental test, using the same semi-active control strategy as in the simulation study. A long stay cable fabricated for a real bridge was set-up with the MR damper installed. The cable was excited under both free and forced vibrations. Different test scenarios were considered where the MR damper was tuned as passive damper with minimum or maximum input current, or the input current of the damper was changed according to the proposed semi-active control algorithm. The effectiveness of the MR damper for controlling the cable vibration was assessed through computing the damping ratio of the cable for free vibration and the root mean square value of acceleration of the cable for forced vibration.

Active Vibration Control of An Automotive Roof using Piezoelectric Sensor and Actuator (압전재료 센서 액츄에이터를 이용한 자동차루프의 능동진동제어)

  • Moon, Sung-Jin;Kim, Chan-Mook;Kang, Young-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.834-839
    • /
    • 2004
  • In this paper, we have studied on the active vibration control of an automotive roof in passenger car's structure using piezoelectric material as the actuator and sensor attached on the surface of the automotive roof, As a control algorithm, negative velocity feedback control method is used in the study and the position of the sensor is almost attached on the nearest position of maximum normal stresses occurring while the roof is vibrating due to disturbance or exciting, Also, the actuator is attached on the other side mostly collocated to the sensor. The optimum positions have the maximum stresses of the roof which have been found in the result of the finite element analysis using Nastran software, As the fundamental experiments, a beam and plate have also been implemented to verify the performance of vibration suppression. Finally the experiment of the roof has been carried out and The roof experiment has just given a possibility to an active vibration control of the automotive structure still not applied for passenger cars.

  • PDF

Real-time Semi-active Vibration Control in Cable-stayed Bridges by Shear-type MR damper and Clipped-optimal Control Algorithm (전단형 MR 댐퍼 및 Clipped-optimal 제어알고리즘을 이용한 사장교의 실시간 준능동 진동제어)

  • Heo, Gwanghee;Jeon, Joonryong;Jeon, Seunggon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.113-123
    • /
    • 2016
  • This paper is concerned with an experimental research to control of random vibration caused by external loads specially in cable-stayed bridges which tend to be structurally flexible. For the vibration control, we produced a model structure modelled on Seohae Grand Bridge, and we designed a shear type MR damper. On the center of its middle span, we placed a shear type MR damper which was to control its vibration and also acquire its structural responses such as displacement and acceleration at the same site. The experiments concerning controlling vibration were performed according to a variety of theories including un-control, passive on/off control, and clipped-optimal control. Its control performance was evaluated in terms of the absolute maximum displacements, RMS displacements, the absolute maximum accelerations, RMS accelerations, and the total power required to control the bridge which differ from each different experiment method. Among all the methods applied in this paper, clipped-optimal control method turned out to be the most effective to reduces of displacements, accelerations, and external power. Finally, It is proven that the clipped-optimal control method was effective and useful in the vibration control employing a semi-active devices such MR damper.