• Title/Summary/Keyword: control vibration

Search Result 4,111, Processing Time 0.03 seconds

Optimal placement and design of nonlinear dampers for building structures in the frequency domain

  • Fujita, Kohei;Kasagi, Masatoshi;Lang, Zi-Qiang;Penfei, Guo;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • v.7 no.6
    • /
    • pp.1025-1044
    • /
    • 2014
  • In this paper, a systematic technique is proposed for the optimal placement and design of nonlinear dampers for building structures. The concept of Output Frequency Response Function (OFRF) is applied to analytically represent the output frequency response of a building frame where nonlinear viscous dampers are fitted for suppression of vibration during earthquakes. An effective algorithm is derived using the analytical representation to optimally determine the locations and parameters of the nonlinear dampers. Various numerical examples are provided to verify the effectiveness of the optimal designs. A comparison of the vibration suppression performance with that of the frame structure under a random or uniform damping allocation is also made to demonstrate the advantages of the new designs over traditional solutions.

Visualization of the Sound Radiation from a Guitar Using Acoustic Holography (음향 홀로그래피를 이용한 기타의 방사음장 가시화)

  • Kim Young-Ju;Choi Joung-Woo;Kim Yang-Han
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.285-288
    • /
    • 1999
  • 기타를 구성하고 있는 요소들, 즉 목, 몸체, 면 그리고 브리지 등이 서로 어떠한 음향학적 관계를 갖고 있고, 그들이 방사 특성에 구체적으로 어떻게 연관되어 있는 지를 밝혀보고자 한다. 이를 위하여는, 기타의 전체 특성 및 개별 요소의 특성을 동시에 살펴볼 수 있는 음향홀로그래피 방법이 가장 설득력이 있다. 본 연구에서는 이 홀로그래피 방법을 이용하여 다음과 같은 결과를 얻었다. 즉, 고주파 대역의 소리는 주로 판을 통해 방사가 되며 저주파 대역은 구멍과 현의 진동을 통해 주로 방사가 된다.

  • PDF

Study of Finite Element Analysis of Tuned Liquid Damper for Seismic Design of High-Rise Building (고층건물 내진설계용 TLD의 유한요소 해석에 관한 연구)

  • Park Seoung-Woo;Cho Jin-Rae;Lee Jae-Hoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.597-602
    • /
    • 2006
  • Many researches have been studied several vibration control device such as TMD and TLD to reduce the influence of wind or seismic waves for high-rise buildings. TLD provides some advantages such as easy installation and low maintenance cost. However, because of the difficulties in evaluating the characteristics of TLD, the dynamic characteristics of TLD must be investigated by experiment or analysis. In this study, the dynamic response analysis of structure with TLD was carried out to verify the vibration control ability of the proposed TLD for high-rise building with about 60 stories. A real seismic wave was used, and the parameter of interest was chosen by the height of water level in the same shape of water tank. From the numerical results, the responses of structure with water tank were confirmed to be safer than those of structure without water tank.

  • PDF

Active and Semi-Active Vibration Control of Piezoelectric Smart Structures Using a Pseudo-Sensor-Output-Feedback Method (PSOF 방법을 이용한 압전 지능 구조물의 능동 및 반능동 진동제어)

  • 김영식;김영태;오동영
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.70-76
    • /
    • 1999
  • This paper presents a pseudo-sensor-output-feedback(PSOF) method for the vibration suppression of the flexible piezoelectric smart structures. This method reduces the modeling errors using pseudo sensors in the output equation formulation. It also reduces computation time in practice. since the output equation does not need the state observer required in the state space equation. Experimental works are performed for the validation of theoretical predictions with the piezoelectric sensor and actuator bonded on the cantilever beam. An algorithm based on the sliding mode control theory is developed and analyzed for the robustness to the modeling errors and parameter uncertainties. This study also discusses the characteristics of the active and semi-active systems.

  • PDF

Vibration Control of Pretwisted Composite Thin-walled Rotating Beam with Non-uniform Cross Section (초기 비틀림각을 갖는 비균일 박판보 블레이드의 진동제어)

  • 임성남;나성수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.6
    • /
    • pp.486-494
    • /
    • 2004
  • This paper addresses the dynamic modeling and closed-loop eigenvibration analysis of composite rotating pretwisted fan blade modeled as non-uniform thin-walled beam with bi-convex cross-section fixed at the certain presetting angle and incorporating piezoelectric induced damping capabilities. The blade model incorporates non-classical features such as transverse shear, rotary inertia and includes the centrifugal and Coriolis force field. A velocity feedback control law relating the piezoelectiriccally induced transversal bending moment at the beam tip with the appropriately selected kinematical response quantity is used and the beneficial effects upon the closed loop eigenvibration of the blade are highlighted.

Derivation of Linearized Dynamic Equations of Motion for HexaSlide Type Parallel Manipulators (6 자유도 HexaSlide 형 병렬기구의 선형화된 운동방정식 유도)

  • Kim, Jong-Phil;Ryu, Je-Ha
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.743-750
    • /
    • 2000
  • This paper presents an equivalent linearization method and application to the equations of motion of a 6 degree-of-freedom PRRS HexaSlide type parallel manipulators which are characterized as the architecture with constant link lengths that are attached to moving sliders on the ground and to a mobile platform. Since dynamic equations of parallel manipulators are complicated and highly nonlinear, control bandwidth, adjustable control gain as well as vibration characteristics cannot be easily found. The proposed equivalent linearization method can be applied over specified workspace as well as on a path of mobile platform. Through an equivalent linearization method, one can easily get a simple linear dynamic model. This linearized dynamic model may be utilized in a simplified computed torque control strategy.

  • PDF

A diagnosis system and ultrasonic vibration energy in plant to quality control

  • Suh, Chang-Min;Song, Gil-Ho;Pyoun, Young-Shik;Kim, Seong-Yun
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.29-34
    • /
    • 2006
  • In this paper, the mechanical characteristics of ultrasonic cold forged technology (UCFT) used for the trimming knife and the effects of ultrasonic vibration energy (UVE) into the trimming process on the state of the strip cutting face were studied. And a diagnosis system to quality control for trimming knife and strip cutting face was developed and installed in plant. By the plant application of UCFT, service life of knife was more increased over 100% than that of conventional knife. And using the developed diagnosis system, the knife breakage and saw ear have been perfectly detected and quality control of trimming face is obtained effectively.

  • PDF

Vibration Control Performance of a Passenger Vehicle Featuring ER Engine Mounts (ER 엔진마운트를 장착한 승용차량의 진동제어 성능)

  • Song, Hyun-Jeong;Choi, Seung-Bok;Jeon, Young-Sik
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.481-486
    • /
    • 2000
  • This paper presents vibration control performance of a passenger vehicle installed with olectro-rheological(ER) engine mounts. As a first step, a mixed-mode ER engine mount is modeled and manufactured. After verifying the controllability of the dynamic stiffness by the intensity of the electric field, ER engine mounts are incorporated with a full-car model. The governing equation of motion is then formulated by considering engine excitation force. A skyhook controller to attenuate vibration motions is designed. The controller is implemented through hardware-in-the-loop simulation and control responses are presented in the both frequency and time domains.

  • PDF

Active Vibration Control of a Plate Using the Distributed Modal Sensitivity (분포모달감도를 이용한 평판의 능동진동제어)

  • 송철기;박재상;이장무;황진권;최종호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.320-325
    • /
    • 1995
  • This study deals with the active vibration control system for an all-clamped rectangular plate with piezoceramic actuators and sensors. A line nonent algorithm (LMA) with the distributed modal sensitivity(DMS) is proposed to reduce the structural vibrations effectively and to select the optimal locations and the optimal directions (skewed angles) of uniform piezoelectric actuators or sensors. Experimental results show that eachmode can attenuated byabout 10 .approx. 13 dB in case a piezoelectric actuator generate the psuedo-random disturbances that excite the plate modes.

  • PDF

Active control of sound fields from vibrating plates using piezoelectric and viscoelastic material (압전재료와 점탄성재료를 이용한 평판진동 음장의 능동제어)

  • 강영규;김재환;최승복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.311-315
    • /
    • 2002
  • The coupled finite/boundary element method is used in numerical analysis for acoustic radiation from the vibration of rectangular composite plate which is simply supported. This analysis is validated using the Wallace equation for an isotropic plate. Active control of sound fields has been carried out using 3 pairs of piezoelectric sensor/actuator and a pair of viscoelastic material by passive constrained layer damping treatment. The results show that the optimal placement of piezoelectric sensor/actuator and VE patch is required to control the sound fields from a vibrating composite plate.

  • PDF