• 제목/요약/키워드: control room

검색결과 1,974건 처리시간 0.028초

족욕요법이 수술실 간호사의 하지 부종, 스트레스 및 피로에 미치는 효과 (Effects of Foot Bath Therapy on Operating Room Nurses' Lower Extremities Edema, Stress, and Fatigue)

  • 이영신;박해경;김현제;정윤희
    • 임상간호연구
    • /
    • 제20권1호
    • /
    • pp.102-112
    • /
    • 2014
  • Purpose: The purpose of this study was to identify the effects of foot bath therapy on operating room (OR) nurses' lower extremities edema, stress, and fatigue. Methods: This study used a randomized control group non-synchronized design. The data were collected from August to October 2013, and a total of 50 OR nurses in an university hospital in U Metropolitan City participated in the study: 25 nurses for the experimental group and 25 for the control group. The experimental group received foot bath in which feet were soaked in $40^{\circ}C$ water and immersed up to ankle line for 20 minutes per a day for 12 times. Results: There were significant decrease in the calf edema, physical stress, and fatigue between pre and post foot bath therapy. Conclusion: The findings of this study show that foot bath had the effect in decreasing lower extremities edema, stress, and fatigue among OR nurses. Foot bath therapy, therefore, is suggested as a comfort and easy-to-use method in clinical setting to reduce OR nurses' lower extremities edema, stress, and fatigue.

유한 두께 창문 모델을 적용한 능동 소음제어 창문 (Active Window system based on Finite Thickness Window Model)

  • 권병호;박영진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.763-768
    • /
    • 2012
  • Active window system which can reduce the environmental noises, such as traffic noise and construction noise, from an open window into a room was proposed in the previous works. The key idea of the proposed active window system was that the control sources are approximately collocated with the primary noise source in terms of the acoustic power for global noise reduction throughout the interior room. Moreover, because it is important not to intrude into the living space in the building environment, no error sensors were used and an open-loop control method using control sources at the window frame and the reference sensors outside the room was used for the proposed system. The open-loop control gain was calculated by the interior room model assumed as the semi-infinite space, and the interior sound field was estimated by Rayleigh integral equation under the baffled window model assumption. However, windows with a finite thickness should were considered for the calculation of the open-loop control gain of the active window system since these are representative of most window cases. Therefore, the finite thickness window model based on the Sgard's model was derived and the open-loop control gain using the interior sound field estimated by that model was calculated for active window system. To compare the performance of these two models, a scale-model experiment was performed in an anechoic chamber according to noise source directions. Experimental results showed that the performance for the thickness window model is better than the baffled window model as the angle with respect to the perpendicular direction is larger.

  • PDF

바닥복사 난방공간의 효율적인 난방제어방법 (The Effective Heating Control Method of the Radiant Floor Heating System)

  • 조성환;태춘섭
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.317-329
    • /
    • 1996
  • By describing the floor slab of a radiant heating system as a one dimensional transient heat exchanger problem, a dynamic analysis model to incorperate with TRNSYS program was developed and their results were compared with experimental results. Results showed that the both of TPOC(Two Parameter On-off Control) and TPSC(Two Parameter Switching Control) method using room air temperature and floor surface temperature as the control parameters does not maintain room air and floor surface temperature exactly at the setting temperatures. But TPSC method is a better candidate for the temperature regulations of room air and floor surface temperature than TPOC method which can keep on the upper and lower limit temperature according to outside temeperature and wall structure etc. And better thermal circumstance can be given by TPSC method than On-off and TPOC method and the overheating which can be occured at the radiant floor heating system with on-off heating control will be reduced.

  • PDF

선박 에너지 절감을 위한 기관실 팬 제어 시스템 구축 및 알고리즘에 관한 연구 (A Study on the Development of the Engine Room Fan Control System and ERFCS Algorithm for Ships Energy Saving)

  • 강영민;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권6호
    • /
    • pp.642-648
    • /
    • 2015
  • 최근 선박에서 에너지 절감에 대한 많은 연구가 수행되고 있다. 그러한 연구의 일환으로 선박의 고정적인 부하를 제외한 변동 부하를 파악하고 제어함으로써 선박의 에너지를 절감할 수 있다. 기관실 팬 시스템은 대표적인 변동부하 중 하나이다. 기존 선박에서는 기관실 팬을 특별한 지침 없이 실 경험에 의해 정격운전으로 운용하고 있다. 이에 본 논문에서는 기관실 팬의 특성을 파악하고, 에너지 관리 시스템 중 하나로 ERFCS(Engine Room Fan Control System) 및 ERFCS 알고리즘을 제안하였다. ERFCS는 온도 및 압력에 따라 팬의 속도를 제어하며 부하 변화에 따라 팬의 운전 대수를 1대에서 4대 사이로 조절한다. 또한 기관실 팬의 최소 회전속도를 50%로 제한하여 낮은 RPM(Revolution Per Minute)에서 기계적 마찰, 발열 등의 이유로 팬이 손상을 입거나 낮은 압력으로 팬에 서징(surging) 현상이 발생하지 않도록 한다. 제안된 알고리즘과 ISO 8861을 바탕으로 LabVIEW를 사용한 팬 제어 시스템 시뮬레이션을 개발하였다. 결론적으로, 구현된 시뮬레이션을 통해 제안된 팬 제어 시스템이 기존 사용 방식에 비해 46.4%만의 동력만으로도 운전이 가능함을 확인하였다.

노인요양시설 방역을 위한 시설 개선 방안 (Architectural Improvement plans in a quarantine system for Senior facilities)

  • 강지은;권순정;이현진
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제27권3호
    • /
    • pp.61-69
    • /
    • 2021
  • Purpose: Senior long-term care facilities are vulnerable to a cluster infection because of frequent physical contact, large group dining, communal living, and room sharing. This study aims to provide architectural improvement plans for a quarantine system in the facilities. Methods: Actual quarantine action data, guidelines from governments and institutes, in-depth interviews with facility staff are analyzed. Results: To prevent a cluster infection in the senior facilities, it is necessary to provide an architectural plan focusing on increasing the number of single rooms and isolation rooms, providing isolation rooms for staff, separation of a soiled room from a clean room, planing an entry vestibule and a visitor's room. Implications: It is important to analyze the existing condition of facilities that had been going through cohort isolation and provide the architectural solution to strengthen infection control.

실온하강신간 예측을 위한 신경망 모델의 개발 (Development of Artificial Neural Network Model for the Prediction of Descending Time of Room Air Temperature)

  • 양인호;김광우
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.1038-1047
    • /
    • 2000
  • The objective of this study is to develop an optimized Artificial Neural Network(ANN) model to predict the descending time of room air temperature. For this, program for predicting room air temperature and ANN program using generalized delta rule were collected through simulation for predicting room air temperature. ANN was trained and the ANN model having the optimized values-learning rate, moment, bias, number of hidden layer, and number of neuron of hidden layer was presented.

  • PDF

납-고무베어링을 적용한 제어장치의 동적평가를 위한 해석적 연구 (Analytical Study to Determine the Dynamic Property of Control Equipment Room using LRB)

  • 김우범;김대곤;이경진;박병구
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.473-480
    • /
    • 2003
  • In these days, The base isolation system is often used improve the seismic capacity of the structure Instead of conventional techniques of strengthening the structural members. The purpose of this study is to evaluate dynamic property evaluation of control equipment using Lead Rubber Bearing. In this study, analysis numerical was performed to determine the optimal dynamic property of lead rubber bearing and damper which minimize the response of base from in main control room. Also the analytical results was composed with the test results peformed in previous study

  • PDF

바닥복사 난방시스템의 제어방식에 관한 실험적 연구 (An Experimental Study on the Control Methods of Radiant Floor Heating Systems)

  • 김오봉;이진영;여명석;석호태;김광우
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1297-1305
    • /
    • 2001
  • In this study, existing control methods that are suggested or applied until now are classified by control parameters, and stability of in the room and floor surface temperatures of each control method is compared through experiments. Then, the control performance of these control methods are analyzed to evaluate the applicability to Korean apartment housing. From the result of the applicability analysis, the outdoor reset with on/off PWM control is found to be desirable for district heating systems and flux modulation is found to be applicable for decentralized heating systems. In the case of independent control systems for each room, on/off PWM control is desirable.

  • PDF

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • 제7권2호
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.