• Title/Summary/Keyword: control network protocol

Search Result 1,451, Processing Time 0.029 seconds

Prolong life-span of WSN using clustering method via swarm intelligence and dynamical threshold control scheme

  • Bao, Kaiyang;Ma, Xiaoyuan;Wei, Jianming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.6
    • /
    • pp.2504-2526
    • /
    • 2016
  • Wireless sensors are always deployed in brutal environments, but as we know, the nodes are powered only by non-replaceable batteries with limited energy. Sending, receiving and transporting information require the supply of energy. The essential problem of wireless sensor network (WSN) is to save energy consumption and prolong network lifetime. This paper presents a new communication protocol for WSN called Dynamical Threshold Control Algorithm with three-parameter Particle Swarm Optimization and Ant Colony Optimization based on residual energy (DPA). We first use the state of WSN to partition the region adaptively. Moreover, a three-parameter of particle swarm optimization (PSO) algorithm is proposed and a new fitness function is obtained. The optimal path among the CHs and Base Station (BS) is obtained by the ant colony optimization (ACO) algorithm based on residual energy. Dynamical threshold control algorithm (DTCA) is introduced when we re-select the CHs. Compared to the results obtained by using APSO, ANT and I-LEACH protocols, our DPA protocol tremendously prolongs the lifecycle of network. We observe 48.3%, 43.0%, and 24.9% more percentages of rounds respectively performed by DPA over APSO, ANT and I-LEACH.

Design of a Remote Distributed Embedded System Using the Internet and CAN (인터넷과 CAN을 이용한 원격 분산 Embedded System 설계)

  • Lee, Hyun-suk;Lim, Jae-nam;Park, Jin-woo;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.5
    • /
    • pp.434-437
    • /
    • 2002
  • A small size and light-weight DSP board is newly designed for a real time multi-distributed control system that overcomes constraints on time and space. There are a variety of protocols for a real-time distributed control system. In this research, we selected CAN for the multi distributed control, which was developed by the BOSCH in the early 1980's. If CAN and Internet are connected together, the system attains the characteristics of a distributed control system and a remote control system simultaneously. To build such a system. The TCP/IP-CAN Gateway which converts a CAN protocol to TCP/IP protocol and vice verse, was designed. Moreover, the system is required to be small and light-weighted for the high mobility and cost effectiveness. The equipment in remote place has a TCP/IP-CAN Gateway on itself to be able to communicate with another systems. The received commands in the remote site are converted from TCP/IP protocol to CAN protocol by the TCP/IP-CAN Gateway in real time. A simulation system consists of a TCP/IP-CAN Gateway in remote place and a command PC to be connected to Ethernet.

Performance Analysis of the HIPERLAN Channel Access Control Protocol (고속 무선 근거리 통신망(HIPERLAN) 채널접근제어 프로토콜의 성능분석)

  • Hyun, Young-Guen;Lee, Jong-Kyu
    • Journal of KIISE:Information Networking
    • /
    • v.27 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • In this paper, we analyzed the performance of EY-NPMA(Elimination Yield-Non-preemptive Priority Multiple Access) protocol-channel access control protocol of HIPERLAN(HIgh PErformance Radio Local Area Network) type 1 specification, adopted as european high speed wireless LAN standard by ETSI(European Telecommunication Standards Institute). We established a system model for EY-NPMA protocol analysis, analyzed success probability in a channel access cycle, and derived expressions for the average length of contention phase. Using a M/G/1 model, we approximated the normalized delay, and throughput, and we evaluated these results by simulations.

  • PDF

Remote Measurement of the Automobile′s ECU Signals with KWP2000 using Bluetooth Module (Bluetooth 모듈을 이용한 KWP2000 차량 ECU신호의 원격 계측)

  • Choi Kwang-Hun;Kwon Tae-Kyu;Lee Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.86-93
    • /
    • 2004
  • This paper presents the remote measurement of the ECU signals adopted with KWP 2000 protocol using the wireless communication technique of bluetooth. The bluetooth technology will be the most promising network paradigm which can open the new area in the information technology. Especially, bluetooth module is able to link all the electrical products and personal computers to cellular phone or PDA. This research has a try to design a wireless measurement model of ECU signal based on the car telemery system using bluetooth device. In order to measure the ECU signals, we designed the interface circuits which is able to communicate between the ECU system and the terminal circuits according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3c341 OX is used for the system control and communication of ECU signals. The embedded system software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on Micro/OS-II kernel to communicate between two bluetooth modules using bluetooth stack. The remote measurement of ECU signals using the bluetooth was designed and implemented to evaluate the performance of wireless network to the transmit measurement data. The possibility for the remote measurement of the self diagnosis signals of ECU adopted with KWP2000 protocol verified through the developed systems and algorithms in embedded system.

A Simulation-Based Study of FAST TCP Compared to SCTP: Towards Multihoming Implementation Using FAST TCP

  • Arshad, Mohammad Junaid;Saleem, Mohammad
    • Journal of Communications and Networks
    • /
    • v.12 no.3
    • /
    • pp.275-284
    • /
    • 2010
  • The current multihome-aware protocols (like stream control transmission protocol (SCTP) or parallel TCP for concurrent multipath data transfer (CMT) are not designed for high-capacity and large-latency networks; they often have performance problems transferring large data files over shared long-distance wide area networks. It has been shown that SCTP-CMT is more sensitive to receive buffer (rbuf) constraints, and this rbuf-blocking problem causes considerable throughput loss when multiple paths are used simultaneously. In this research paper, we demonstrate the weakness of SCTP-CMT rbuf constraints, and we then identify that rbuf-blocking problem in SCTP multihoming is mostly due to its loss-based nature for detecting network congestion. We present a simulation-based performance comparison of FAST TCP versus SCTP in high-speed networks for solving a number of throughput issues. This work proposes an end-to-end transport layer protocol (i.e., FAST TCP multihoming as a reliable, delaybased, multihome-aware, and selective ACK-based transport protocol), which can transfer data between a multihomed source and destination hosts through multiple paths simultaneously. Through extensive ns-2 simulations, we show that FAST TCP multihoming achieves the desired goals under a variety of network conditions. The experimental results and survey presented in this research also provide an insight on design decisions for the future high-speed multihomed transport layer protocols.

A Design of Hop-by-Hop based Reliable Congestion Control Protocol for WSNs (무선 센서 네트워크를 위한 Hop-by-Hop 기반의 신뢰성 있는 혼잡제어 기법 설계)

  • Heo Kwan;Kim Hyun-Tae;Ra In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.6
    • /
    • pp.1055-1059
    • /
    • 2006
  • In Wireless Sensor Networks(WSNs), a sensor node broadcasts the acquisited sensing data to neighboring other nodes and it makes serious data duplication problem that increases network traffic loads and data loss. This problem is concerned with the conflict condition for supporting both the reliability of data transfer and avoidance of network congestion. To solve the problem, a reliable congestion control protocol is necessary that considers critical factors affecting on data transfer reliability such as reliable data transmission, wireless loss, and congestion loss for supporting effective congestion control in WSNs. In his paper, we proposes a reliable congestion protocol, called HRCCP, based on hop-hop sequence number, and DSbACK by minimizing useless data transfers as an energy-saved congestion control method.

Performance Analysis of the UPC/NPC Algorithm for Guaranteed QoS in ATM Networks

  • Kim, Yong-Jin;Kim, Jang-Kyung;Lee, Young-Hee;Park, Chee-Hang
    • ETRI Journal
    • /
    • v.20 no.3
    • /
    • pp.251-271
    • /
    • 1998
  • It is well known that if usage parameter control/network parameter control (UPC/NPC) functions are used together with a cell loss priority control scheme in ATM networks, the measurement phasing problem can occur. This makes it difficult for a network provider to define and commit the cell loss ratio as a QoS parameter. To solve the problem, we propose a new UPC/NPC algorithm. By using the proposed UPC/NPC algorithm, we can define the cell loss ratios for CLP = 0 and CLP = 0+1 cell streams without the measurement phasing problem under any conditions. We analyzed the performance of the proposed UPC/NPC algorithm. Using a discrete time model for the UPC/NPC architecture with a discrete-time semi-Markov process (DSMP) input model, we obtained the cell discarding probabilities of CLP = 0 and CLP = 0+1 cells streams and showed that more CLP = 0 cells are accepted compared to what was proposed in ITU-T.

  • PDF

A Study on the Network Architecture for KEPCO SCADA Systems (한국전력 스카다 시스템의 네트워크 구조에 대한 연구)

  • Ryo, Woon Jong
    • Industry Promotion Research
    • /
    • v.2 no.2
    • /
    • pp.1-6
    • /
    • 2017
  • SCADA (Supervisory Control and Data Acquisition) System was first introduced to the Seoul Electricity Authority, which manages the transportation part among the three business fields that produce, transport and supply electric power in Korea. Has been using the data link with 1200 bps and 9600 bps in 5 protocols such as HARRIS 6000, BSC, HDLC, L & N and Toshiba by configuring 3 layers of EMS, SCADA and RTU computer equipments in 1: N radial form. This paper presents the OSI standard network packet flow, analyzing DataLink and Network Layer, and presents a KEPCO SCADA network model composed of X.25 high - speed communication network using 3 layers of network. We proposed a future SCADA communication structure that improved the current SCADA communication structure, defined the SCADA DB structure, introduced the concept of the remote SCADA gateway to the SCADA functional structure, applied the standard communication protocol, Multiplexing of surveillance and control in other local facilities and ensuring communication openness.

Processing of Congestion Problem in the Interworking Node (연동 노드에서 집중 문제 처리)

  • 김평중
    • Journal of the Korean Professional Engineers Association
    • /
    • v.29 no.3
    • /
    • pp.94-104
    • /
    • 1996
  • When Broadband Integrated Services Digital Network(BISDN) becomes commercially available In public network, conventional Local Area Network(LAN)s will still be in use. The first wide spread application for B-ISDN will be the interconnection of LANs. The equipment providing the connection between the LAN and the BISDN will be given the general name Inter Working Unit(IWU). We addresses the congestion problem of many interworking issues. In this paper, Our study is concentrated on applying connectionless network protocol for interworking. We suggest a rate control method in the network layer to prevent a buffer overflow in the IWU. Since this rate control method can be applied to prevent buffer overflow in a congested IWU, We investigate the use of rate control to solve congestion problems of IWU and parallize network layer with rate control to lessen the congestion problem in IWU.

  • PDF