• Title/Summary/Keyword: control leakage

Search Result 932, Processing Time 0.031 seconds

Single Stage Resonant Power Supply for Driving Magnetron Device (마그네트론 구동용 단일단 공진형 전원장치)

  • Jeong Jin-Beom;Yeon Jae-Eul;Kim Hee-Jun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.10
    • /
    • pp.625-633
    • /
    • 2004
  • This paper proposed a boost input type single stage resonant power supply for driving magnetron device. The proposed power supply can control both input power factor and output power at the same time. Also, because ZVS is achieved using the resonance between leakage inductance and resonant capacitance, switching losses are drastically reduced. To prevent breakdown or moding phenomenon of the magnetron due to excessive starting voltage, variable frequency ignition method is also proposed. Experimental results for the prototype power supply are presented and discussed to verify the validity of the proposed power supply.

Power Factor with Single Power Stage AC/DC Converter Operated in Active-Clamp Mode (능동 클램프 모드로 동작하는 단일 전력 AC/DC 컨버터에 의한 역률개선)

  • Yoon, Shin-Yong;Baek, Hyun-Soo;Kim, Yong;Kim, Cherl-Jin;Eo, Chang-Jin
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.392-401
    • /
    • 2001
  • This paper presents the single-stage high power factor AC to DC converter operated in active-clamp mode. The proposed converter is added active-clamping circuit to boost-flyback single-stage power factor corrected power supply. The active-clamping circuit limits voltage spikes, recycles the energy trapped in the leakage inductance, and provides a mechanism for achieving soft switching of the electronic switches to reduce the switching loss. The auxiliary switch of active-clamping circuit uses the same control and driver circuit as the main switch to reduce the additional cost and size. To verify the performance of the proposed converter, a 100W converter has been designed. The proposed converter gives good power factor correction, low line current harmonic distortions, and tight output voltage regulation, as used unity power factor.

  • PDF

Maximum Torque Operation of an Induction Machine in the field weakening regoin (약계자 영역에서 유도전동기의 최대 토오크 운전)

  • 김상훈;설승기;박민호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • In this paper, a new approach for the induction machine control whih ensures producing maximum torque per ampere over the entire field weakening region is presented. In addition, the relation of the output torque capability with the leakage factor of the machine is examined. Also the smooth and precise transition into the field weakening operation can be achieved by adjusting the base speed for the field weakening operation according to the flux level, the current limit and the voltage limit. The proposed is verified through simulation and experiment for a 5hp laboratory induction motor drive system.

  • PDF

Reducing the Harmonics of Static Var Compensator Using Multi-Step Inverter (멀티-스텝 인버터를 이용한 무효전력 보상장치의 고조파 저감)

  • Park, Hyun-Chul;Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.19-22
    • /
    • 2001
  • For stabilization and improving power factor in the power lines, various Static Var Compensators(SVC) have been considered to be installed and partly applicated already. With all these merits of the SVC, it stil has demerits, principally evoking harmonic problems. So far, many harmonic reduction type inverters have been used in various parts. In this paper, the reactive power is controlled by amplitude of the output voltage. This paper propose that the multiple voltage source inverter have controllable power factor made by load vary at receive-stage as lagging and leakage control. The theoretical analysis on this system was confirmed through the computer simulation and the experiments.

  • PDF

Subaxillary Minithoracotomy for Treatment of Primary Spontaneous Pneumothorax (액와부 소절개를 통한 원발성 자연기흉의 치료)

  • 정성규
    • Journal of Chest Surgery
    • /
    • v.25 no.10
    • /
    • pp.1020-1024
    • /
    • 1992
  • Thirty-four patients underwent 39 subaxillary minithoracotomies for the treatment of primary spontaneous pneumothorax from June 1987 to April 1992. The age of patients ranged from 17 to 32 years. The ratio of male to female was 8.8: 1 with male predominance. The associated pulmonary lesions and pleural adhesion were not seen on the chest X-rays in all cases. Average operative time was 83 minutes[30~130 min]. Postoperative average duration of air leakage was 2.4 days, the chest tube indwelling was 5.1 days, and postoperative hospital stay was 8 days, Analgegics were not given for pain control postoperatively In conclusion, the subaxillary minithoracotomy has the following advantages: reducing the operative time, postoperative pain, morbidity, hospital stay, shoulder problems, and excellent cosmetic result.

  • PDF

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

Case Studies on Investigation Technologies on Embankments (제방의 조사 기술에 관한 고찰)

  • Yang, Tae-Seon;Kim, Jin-Man;Choi, Bong-Hyuck;Kim, Ju-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.680-688
    • /
    • 2008
  • On behalf of hazard mitigation, cases of investigation methods on levee are described. In general, failures of levee are caused by piping, water leakage through ground under the levee in Kimpo, Ilsan etc. Several phenomena against levees should be protected through consideration of analysis and quality control stage during construction. In this paper, protection methods against failures should be investigated by case studies.

  • PDF

Improvement of Cooling Water Quality by Corrosion and Scale Inhibitor (부식 및 스케일 억제제에 의한 냉각수 수질향상)

  • Jo, Kwan-Hyung;Woo, Dal-Sik;Hwang, Byung-Gi
    • Journal of Environmental Science International
    • /
    • v.18 no.2
    • /
    • pp.187-195
    • /
    • 2009
  • This study was investigated to control the corrosion and scale at the cooling water system in steel works. Laboratory and field tests were performed for the indirect cooling water system of plate mill. Throughout the experiment, various factors such as leakage of pipes, heating rate and capacity, and the reaction between existing and substitute inhibitors were carefully monitored. The results showed that the harmful effect of high temperature could be minimized, and satisfactory corrosion/scale controls were effectively achieved using inhibitor, even at the increased temperature of $80^{\circ}C$. The batch and field tests in the gas scrubbing cooling water system of blast furnace and cooling water system of corex plant indicated that the new inhibitor was more effective for the prevention of corrosion and scale than the existing one.

A Study on Minimizing for Hydration Heat Cracks of a Subway Concrete Box Structure (지하철 콘크리트 BOX 구조물의 수화열에 의한 균열저감 대책 연구)

  • Kim, Eun-Kyum;Youn, Seok-Goo;Bae, Sang-Il;Jeong, Jae-Yong;Kim, Hyeon-Cheol;Heo, Jeong-Ok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.425-428
    • /
    • 2006
  • The bigger of concrete strctures by a construct technique improvement, and the increase of the cement quantity which is caused by with use of the high-strength concrete for the load-carrying-capacity and a durability cause temperature cracks by a heat of hydration. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box strucuture, the use of blended cement, the temperature of air and concrete, control joint, was considered and analysed by a three dimensional finite element method.

  • PDF

Electrical Properties of Zinc Oxide Varistor with $\alpha-Zn_7Sb_2O_{12}$ ($\alpha-Zn_7Sb_2O_{12}$ 첨가에 의한 Zinc Oxide 바리스터의 전기적 특성)

  • 김경남;한상목
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.11
    • /
    • pp.1396-1400
    • /
    • 1994
  • Electrical properties in the ZnO-Bi2O3-CoO-Zn7Sb2O12 system were investigated with Zn7Sb2O12 content (0.1~2 mol%). The increase of the Zn7Sb2O12 content inhibited the grain growth of ZnO, which showed a narrow grain size distribution of ZnO. The breakdown voltage (Vb) increased markedly with 1 mol% Zn7Sb2O12 addition due to the grain growth control behaviour of the Zn7Sb2O12 . The nonlinear I-V characteristic was significantly influenced by the Zn7Sb2O12 content (or Bi2O3/Zn7Sb2O12 ratio). Addition of 0.5 mol% Zn7Sb2O12 showed the highest nonlinear coefficient ($\alpha$) of 43. The leakage current in prebreakdown region was decreased with increasing Zn7Sb2O12 content.

  • PDF