• Title/Summary/Keyword: control leakage

Search Result 943, Processing Time 0.033 seconds

Smartphone Camera Control System in connection with Personnel Access Rights (인원 출입 권한과 연계한 스마트폰 카메라 제어 시스템)

  • Jeon, Byung-Jin;Han, Kun-Hee;Shin, Seung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.93-101
    • /
    • 2017
  • The purpose of this paper is to investigate the effect of the smart phone camera on the company's employees or employees of partner companies, we want to block things in advance. In this paper, we propose a smart phone camera control system which is connected with the personnel access right which enables to share the photographed image of the authorized user and the data shot only within the enterprise. To this end, we have developed the installation status of smart phone control program (MCS: Mobile Camera Control System) of employees, employees and visitors of company, and experimented and analyzed whether the smart phone control program installed in the authorized area. In addition, when visitors visited the company, the effect of prevention of photograph shooting through smart phone camera and the cost of seal sticker attached to the smart phone camera lens part were reduced.

Experimental Study of Operating Parameters for Pneumatic Control Valve in Abnormal Conditions (공기구동 제어밸브 비정상상태 운전변수에 관한 실험적 연구)

  • Kim, Yang-seok;Kim, Dae-woong;Lee, Byoung-oh;Jeoung, Rae-hyuk;Lee, Seung-ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.613-619
    • /
    • 2016
  • A pneumatic control valve performs a major role in controlling the flow of a system or the level of a key tank in many power plants, and its performance should be guaranteed during the plant's lifetime. Its operation starts by supplying air to the pneumatic actuator or by exhausting the air from the actuator. To control the valve position, the amount of air supply or exhaust is adjusted by a control loop where various accessaries are equipped. In this paper, air leakage in the air supply line, changes in the valve packing force, and false adjustments of zero and the span of the positioner are simulated and analyzed using a 2-in pneumatic valve with a position control loop including an I/P converter and positioner, where the valve position is controlled within ${\pm}2%$ of the control pressure at 67% opening position.

Software Design of Computerized Gas Safety Control System (컴퓨터에 의한 가스안전 제어시스템 소프트웨어 설계)

  • Kim Tae-Ok;Jou Wouseok;Park Hyunmin;Lee Hern-Chang;Chang Seo-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.1 s.22
    • /
    • pp.30-36
    • /
    • 2004
  • Although the usage of gas as one of the most economical energy source is ever expanding, numerous gas accidents occur as a result of negligence in safety management. The main reason behind such accident is that the current safety control system relies heavily on the manual control mechanism. This paper designed and developed a prototype of a computerized gas safety control system that automates such critical functions as the alarm sensing and the valve control. Since the system is connected through a digital network, the control can be performed remotely. Most importantly, the accidental risk or damage can be greatly reduced since the system monitors and reacts actively to gas leakage in real time.

  • PDF

Clinical Safety and Efficiency of the H-Port for Treatment of Leptomeningeal Metastasis

  • Sung-Min Jang;Ho-Shin Gwak;Ji-Woong Kwon;Sang Hoon Shin;Heon Yoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.4
    • /
    • pp.467-476
    • /
    • 2024
  • Objective : To evaluate the usefulness of a cranial implantable chemoport, the H-port, as an alternative to the Ommaya reservoir for intraventricular chemotherapy/cerebrospinal fluid (CSF) access in patients with leptomeningeal metastasis (LM). Methods : One hundred fifty-two consecutive patients with a diagnosis of LM and who underwent H-port installation between 2015 and 2021 were evaluated. Adverse events associated with installation and intraventricular chemotherapy, and the rate of increased intracranial pressure (ICP) control via the port were evaluated for safety and efficacy. These indices were compared with published data of Ommaya (n=89), from our institution. Results : Time-to-install and installation-related complications of intracranial hemorrhage (n=2) and catheter malposition (n=5) were not significantly different between the two groups. Intraventricular chemotherapy-related complications of CSF leakage occurred more frequently in the Ommaya than in the H-port group (13/89 vs. 3/152, respectively, p<0.001). Intracranial hemorrhage during chemotherapy occurred only in the Ommaya group (n=4). The CSF infection rate was not statistically different between groups (14/152 vs. 12/89, respectively). The ICP control rate according to reservoir type revealed a significantly higher ICP control rate with the H-port (40/67), compared with the Ommaya result (12/58, p<0.001). Analyzing the ICP control rate based on the CSF drainage method, continuous extraventricular drainage (implemented only with the H-port), found a significantly higher ICP control rate than with intermittent CSF drainage (33/40 vs. 6/56, respectively, p<0.0001). Conclusion : The H-port for intraventricular chemotherapy in patients with LM was superior for ICP control; it had equal or lower complication rates than the Ommaya reservoir.

Sensitive Personal Information Protection Model for RBAC System (역할기반 접근제어시스템에 적용가능한 민감한 개인정보 보호모델)

  • Mun, Hyung-Jin;Suh, Jung-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.5
    • /
    • pp.103-110
    • /
    • 2008
  • Due to the development of the e-commerce, the shopping mall such as auction collects and manages the personal information of the customers for efficient service. However, because of the leakage of the Personal information in auction, the image of the companies as well as the information subjects is damaged. Even though the organizations and the companies store the personal information as common sentences and protect using role based access control technique, the personal information can be leaked easily in case of getting the authority of the database administrator. And also the role based access control technique is not appropriate for protecting the sensitive information of the information subject. In this paper, we encrypted the sensitive information assigned by the information subject and then stored them into the database. We propose the personal policy based access control technique which controls the access to the information strictly according to the personal policy of the information subject. Through the proposed method we complemented the problems that the role based access control has and also we constructed the database safe from the database administrator. Finally, we get the control authority about the information of the information subject.

  • PDF

A Study on the Analysis of Validity and Importance of Event Log for the Detection of Insider Threats to Control System (제어시스템의 내부자 위협 탐지를 위한 Event Log 타당성 및 중요도 분석에 관한 연구)

  • Kim, Jongmin;Kim, DongMin;Lee, DongHwi
    • Convergence Security Journal
    • /
    • v.18 no.3
    • /
    • pp.77-85
    • /
    • 2018
  • With the convergence of communications network between control system and public network, such threats like information leakage/falsification could be fully shown in control system through diverse routes. Due to the recent diversification of security issues and violation cases of new attack techniques, the security system based on the information database that simply blocks and identifies, is not good enough to cope with the new types of threat. The current control system operates its security system focusing on the outside threats to the inside, and it is insufficient to detect the security threats by insiders with the authority of security access. Thus, this study conducted the importance analysis based on the main event log list of "Spotting the Adversary with Windows Event Log Monitoring" announced by NSA. In the results, the matter of importance of event log for the detection of insider threats to control system was understood, and the results of this study could be contributing to researches in this area.

  • PDF

A Study on the Efficiency Method of Location-Based Control Function Applied to MDM Applications (MDM 앱에 적용되는 위치 기반 통제 기능의 효율화 방법에 관한 연구)

  • ChangIk Oh;SuGil Hwang;Hyun Son;Dongho Kim
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.171-177
    • /
    • 2023
  • When configuring MDM services only with applications without a central control server, a method that allows security control to be released based on GPS signals in areas sufficiently far from the security area of the workplace is generally applied by embedding and distributing location information of workplaces in MDM applications. This study proposed a method in which each individual directly enters the location information of the security control area needed for them in the distributed app and maintains it as setting information without embedding location information of a specific area such as work in the MDM applications. The method proposed in this study can improve universality, compatibility and the security control level of MDM services, and minimize deployment costs.

EFFECT OF BISCOVER ON THE MARGINAL MICROLEAKAGE OF COMPOSITE RESIN RESTORATION (복합레진 수복물의 변연 미세누출에 관한 BiscoverTM 전색제의 효과)

  • Cho, Young-Gon;Choi, Hee-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.355-362
    • /
    • 2005
  • The purpose of this study was to compare the effect on marginal leakage of a resin surface sealant (Biscover) applied before or after polymerization of composite resin to unsealed composite restorations. Thirty Class V cavities with the occlusal margin in enamel and cervical margin in dentin or cementum were prepared on the buccal surfaces of sound extracted molars and restored with a microfilled light-cured composite resin (Micronew). Restorations were randomly assigned into one of three equal groups (n = 10): a control group - no surface sealing, group 1 - applied Biscover after polymerization of the composite resin. and group 2 - applied Biscover before polymerization of the composite resin. Specimens were thermocycled, immersed in a $20\%$ methylene blue solution for 4 hoots, sectioned longitudinally, and analyzed for leakage at the occlusal and gingival margins. The results of this study were as follows 1. In sealed group, group 2 showed higher microleakage than group 1 at both occlusal and gingival margins. but there was no significant difference between two groups (p > 0.05). 2. Unsealed control group showed a little higher microleakage than sealed group at occlusal margins, and a little Higher or similar microleakage than sealed group at gingival margins (p > 0.05) 3. Control group and group 2 showed significantly less microleakage at the occlusal margins, but group 1 showed no significantly difference between microleakage at the occlusal and gingival margins.

Influences of Histamine on Permeability across Blood-brain Barrier (혈액-뇌장벽 투과성에 대한 히스타민의 영향)

  • Kim, Kee-Jin;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.33-43
    • /
    • 1968
  • Histamine, 0.5 mg as histamine base in 4 ml of normal saline solution, was injected into rabbits anesthetized with nembutal and the mean blood pressure was kept in the range of $52{\sim}80\;mmHg$ for over one hour by supplemental additions. Following the injection of the test substances, 300 mg of urea and 200 mg of antipyrine intravenously, serial blood samples were obtained from the femoral artery and the internal jugular vein at $0.5{\sim}3$ minutes interval. The decreasing patterns in the concentrations of arterial and venous blood plasma samples were compared with each other. The ratio of the concentration of brain tissue to that of the final arterial plasma was also studied. By these measures the degrees of penetration of the test substances in the brain in the control and in the histamine treated rabbits were observed. The concentrations of antipyrine and urea in the arterial blood plasma were decreasing exponentially with respect to the time elapsed. The venous concentrations were anticipated to increase initially and to cross the arterial concentration curve in the point of equlibrium between the plasma and the tissue. On the contrary to the expectation venous concentration also revealed the decreasing tendency similar to that of arterial plasma. The similarity between these two curves, arterial and venous, would be atributable to the fact that the cerebral blood flow rate was large enough and the rising phase in the venous concentration curve was instantly over before serial blood samples were taken. Inspite of some similarity in the decreasing tedency in both concentration curves there were appreciable discrepancies between the arterial and venous plasma which would reflect the situation far from the equlibria among several compartments in the brain. Changes in plasma potassium levels caused by the injection of histamine or bleeding were observed, too. Using 8 rabbits as the control and 12 rabbits for the histamine treated group following results were obtained: 1. Both of the concentration curves, arterial and venous, declined rapidly at_first and slowly later on and approached same equilibrium concentration with the passage of time after a single injection. The time at which attained the same concentration was $2.0{\pm}0.54\;min.$ in the control and $4.3{\pm}1.92\;min.$ in the histamine treated group with respect to antipyrine. On the other hand in the case of urea they were $2.4{\pm}0.59\;min.$ in the control and $4.4{\pm}1.31\;min.$ in the histamine group, respectively. In the histamine treated group enlarged spaces for distribution of test substances were postulated. 2. The concentration of antipyrine in the brain tissue water revealed no significant differences between the control and experimental groups, showing $212{\pm}40.2\;mg/l$ in the control and $206{\pm}64.1\;mg/l$ in the histamine treated group. On the other hand urea revealed higher value in the histamine treated group than in the control, showing an enhanced penetration of urea into the tissue after injection of histamine. Urea concentration in the brain water was $32.3{\pm}3.36\;mg%$ in the control and $39.2{\pm}4.25\;mg%$ in the histamine treated group. 3. The distribution ratio of antipyrine in the brain tissue was very close to unity in the histamine treated animals as well as in the control. 4. The average of the distribution ratio of urea in the control animals was 0.77 and it showed the presence of blood-brain barrier with regard to urea. However in the histamine treated animals the distribution ratios climbed up to 0.86 and they were closer to unity than in the control animals. Out of 12 cases 5 were greater than 0.9 and 8 exceeded 0.85. It appeared that histamine enhanced the penetration of urea through the barrier. 5. Histamine injection and or hemorrhage caused an elevation of the concentration of potassium in plasma. In the event that histamine and hemorrhage were applied together the elevation of potassium exceed the elevation seen at the histamine alone. There was no evidence that the leakage of potassium from the brain tissue was dominant in comparison with the general leakage from the whole body.

  • PDF

Rectifier with Comparator Using Unbalanced Body Biasing to Control Comparing Time for Wireless Power Transfer (비대칭 몸체 바이어싱 비교기를 사용하여 비교시간을 조절하는 무선 전력 전송용 정류기)

  • Ha, Byeong Wan;Cho, Choon Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1091-1097
    • /
    • 2013
  • This paper presents a rectifier with comparator using unbalanced body biasing in $0.11{\mu}m$ RF CMOS process. It is composed of MOSFETs and two comparators. The comparator is used to reduce reverse leakage current which occurs when the load voltage is higher than input voltage. For the comparator, unbalanced body biasing is devised. By using unbalanced body biasing, reference voltage for comparator changing from high state to low state is increased, and it reduces time interval for leakage current to flow. 13.56 MHz 2 Vpp signal is used for input and $1k{\Omega}$ resistor and 1 nF capacitor are used for output load for simulation and experimental environment. In simulation environment, voltage conversion efficiency(VCE) is 87.5 % and Power conversion efficiency(PCE) is 50 %. When the rectifier is measured, VCE shows 90.203 % and PCE shows 45 %.