• Title/Summary/Keyword: contrast reduction

Search Result 667, Processing Time 0.023 seconds

Effects of Transmittance of Diffusive Blur on Visual Acuity and Contrast Sensitivity (확산적 흐림의 투과율이 시력과 대비감도에 미치는 영향)

  • Yang, Seok-Jun;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.355-362
    • /
    • 2015
  • Purpose: To investigate the effects of the transmittance of diffusive blurson visual acuity and contrast sensitivity. Methods: Visual acuity and contrast sensitivity were measured by using Optec$^{(R)}$ 6500 in Healthy 30 subjects aged $22.83{\pm}0.50$ (male 13, female 17) who were recruited from university students. Cataract simulator was used as a tool for diffusive blur. Visual acuity and contrast sensitivity were measured with varying the transmittance of diffusive blur in order to simulate progression of cataract and concentration in fog. Results: Visual acuity was reduced proportionally with decreasing the transmittance of the diffusive blur as follows: $VA(T)=1.84{\times}10^{-2}T-0.645$. Contrast sensitivity was decreased in all spatial frequencies. Contrast sensitivity in a high spatial frequency band was a greater effect and was off the normal range of contrast sensitivity. The peak of contrast sensitivity was moved in the direction to low frequency. From an intersection point of contrast sensitivity function, we could calculated the transmittance of the diffusive blur being off the normal range and the shift to peak spatial frequency. The peak of contrast sensitivity function was observed to move from 6 to 3 cpd at transmittance of about 78.70%, the contrast sensitivities for all frequencies at transmittance of about 69.71% were deviated from the normal range. Conclusions: The transmittance of diffusive blur causes a reduction in visual acuity and contrast sensitivity, a deviation of normal range of contrast sensitivity, and a shift of peak contrast sensitivity. Therefore the more attention is required when suffering from cataracts or driving in fog.

PHOTOCHEMICAL REACTIONS OF PSEUDOSACCHARIN 3-ALLYL ETHER (PROBENAZOLE) AND ITS ALKYL ETHER

  • Yoon, Ung-Chan
    • Journal of Photoscience
    • /
    • v.2 no.2
    • /
    • pp.77-81
    • /
    • 1995
  • Photoreactions of pseudosaccharin ethers have been investigated. Pseudosaccharin 3-allyl ether undergoes a facile photoreaction via reaction pathways involving homolysis of bond between pseudosaccharyl oxygen and 3-allyl carbon, and excited nucleophilic substitution of allyloxy group by solvent which are not quenched by oxygen present in the reaction. Product yield demonstrates that the homolysis pathway predominates over the nucleophilic substitution in ca. 7:1 ratio. In contrast, pseudosaccharin alkyl ethers follow different reaction routes to produce two products, solvent-substituted pseudosaccharin alkyl ethers and reduction products, 3-alkoxy-1, 2-benzisothiazoles. The formations of reduction products, 3-alkoxy-1, 2-benzisothiazoles are completely quenched by oxygen.

  • PDF

A New Driving Waveform for Stable Address Discharge in an Alternating Current Plasma Display Panel

  • Kim, Sung-Hwan;Seo, Jeong-Hyun;Lee, Seok-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.503-506
    • /
    • 2004
  • In this paper, we suggest a new driving waveform for stable address discharge in AC PDP without the reduction of contrast ratio. To analyze the influence of cross-talk between discharge and non-discharge cells and verify that proposed waveform shows a stable address discharge, we measured the address discharge delay time. The proposed waveform shows the reduction of the cross-talk and concurrently the improvement of address voltage margin compared with those of selective reset waveform having one reset period in 1TV-Field..

  • PDF

Fast non-local means noise reduction algorithm with acceleration function for improvement of image quality in gamma camera system: A phantom study

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.719-722
    • /
    • 2019
  • Gamma-ray images generally suffer from a lot of noise because of low photon detection in the gamma camera system. The purpose of this study is to improve the image quality in gamma-ray images using a gamma camera system with a fast nonlocal means (FNLM) noise reduction algorithm with an acceleration function. The designed FNLM algorithm is based on local region considerations, including the Euclidean distance in the gamma-ray image and use of the encoded information. To evaluate the noise characteristics, the normalized noise power spectrum (NNPS), contrast-to-noise ratio (CNR), and coefficient of variation (COV) were used. According to the NNPS result, the lowest values can be obtained using the FNLM noise reduction algorithm. In addition, when the conventional methods and the FNLM noise reduction algorithm were compared, the average CNR and COV using the proposed algorithm were approximately 2.23 and 7.95 times better than those of the noisy image, respectively. In particular, the image-processing time of the FNLM noise reduction algorithm can achieve the fastest time compared with conventional noise reduction methods. The results of the image qualities related to noise characteristics demonstrated the superiority of the proposed FNLM noise reduction algorithm in a gamma camera system.

Change of Fixation Disparity and Accommodation when the Fusion Contrast Varied (융합대비에 따른 주시시차와 조절의 변화)

  • Seo, Jae-Myoung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: To study the change of fixation disparity and accommodation as fusion contrast is deteriorated. Methods: 16 subjects who had above 20/20 and stereopsis took part. Monocular and binocular refraction were done with Zeiss Polatest Classic whereas the critical angle for stereopsis was done with TNO. A computer programmed with Random-Dot stereogram and vernier test managed a precise change of the fusion contrast and exposure time. Results: The fixation disparity was influenced by reduction of fusion contrast and had tendancy to exophoria (p=0.0004), especially it is considerably higher when uncrossed disparity was shown to exophoric subjects. Although accommodation was not influenced by a change of fusion contrast (p=0.803), vernier acuity was influenced (p=0.0000). Conclusions: Exophoric trend arose as the fusion contrast was reduced, nevertheless there was no accommadative change.

  • PDF

The Effects of Total Variation (TV) Technique for Noise Reduction in Radio-Magnetic X-ray Image: Quantitative Study

  • Seo, Kanghyen;Kim, Seung Hun;Kang, Seong Hyeon;Park, Jongwoon;Lee, Chang Lae;Lee, Youngjin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.593-598
    • /
    • 2016
  • In order to reduce the amount of noise component in X-ray imaging system, various reduction techniques were frequently used in the field of diagnostic imaging. Although the previous techniques -such as median, Wiener filters and Anscombe noise reduction technique - were able to reduce the noise, the edge information was still damaged. In order to cope with this problem, total variation (TV) noise reduction technique has been developed and researched. The purpose of this study was to evaluate and compare the image quality using normalized noise power spectrum (NNPS) and contrast-to-noise ratio (CNR) through simulations and experiments with respect to the above-mentioned noise reduction techniques. As a result, not only lowest NNPS value but also highest CNR values were acquired using a TV noise reduction technique. In conclusion, the results demonstrated that TV noise reduction technique is proved as the most practical method to ensure accurate denoising in X-ray imaging system.

Simultaneous Measurement of Size and Velocity of Microbubbles inside Opaque Tube Using X-ray PTV Technique (X-ray PTV 기법을 이용한 불투명 튜브 내부의 미세기포의 크기 및 속도 동시 측정)

  • Kim, Seok;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.69-75
    • /
    • 2006
  • The microbubbles were used in various fields, such as turbulent control, drag reduction, material science and life science. The X-ray PTV using X-ray micro-imaging technique was employed to mea-sure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}$=2.7mm) were tested. Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of over-lapped microbubbles. In all of the working fluids tested (deionized water, tap water, 0.01 and 0.10M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The rising velocity was increased with increasing mole concentration. The microbubble can be useful as contrast agent or tracer in life science and biology. The X-ray PTV technique should be able to extract useful information on the behavior of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.

  • PDF

The Reduction of Address Discharge Delay Time Using a New Driving Method (새로운 구동방식을 이용한 어드레스 방전 지연시간의 감소)

  • Song, Keun-Young;Kim, Gun-Su;Seo, Jeong-Hyun;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.123-125
    • /
    • 2004
  • In order to achieve high efficiency and low cost, new high-speed addressing method is suggested. This can be achieved by reducing the address discharge delay time through the priming effect. This paper suggests a new ADR (Address During Reset) driving method which provides priming particles by using a separated driving method without adding auxiliary electrode or auxiliary discharge. The experimental results show an approximately loons reduction in the formative delay time of address discharge and a reduction in jitter of over 200ns. Also, due to enough time being available for reset, there was a reduction in light emitted during reset of about 29% which improved the dark contrast ratio considerably.

  • PDF

Discrimination Energy Range Analysis of Contrast Agents and Calcification using by VNC Application of DECT (DECT의 VNC 적용으로 조영제와 석회화의 식별 에너지 영역 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.179-185
    • /
    • 2024
  • By applying the various energy spectrum imaging functions of DECT, To quantitatively distinguish between contrast agent and calcification, changes in image quality are analyzed by comparing CNR and SNR. We investigated the level of dose reduction during two scans and one VNC scan. As a result, contrast agent and calcification were best distinguished in the 70 keV area, CNR and SNR were excellent, and scan dose was reduced by about 26.5%. Therefore, by applying DECT, meaningful results were obtained that could visually and quantitatively distinguish between the intravascular contrast agent and the shade of calcification. If clinical research is conducted in the future considering the patient's age, gender, and body type, quantitative analysis of calcification will be possible even with intravascular contrast agent flowing in, which will have a significant effect in reducing the patient's scan dose and the burden of multiple scans.