• Title/Summary/Keyword: continuous-wave

Search Result 795, Processing Time 0.028 seconds

Influence of plugger penetration depth on the apical extrusion of root canal sealer in Continuous Wave of Condensation Technique (플러거 삽입깊이가 근관실러의 치근단 정출에 미치는 영향)

  • So Ho-Young;Lee Young-Mi;Kim Kwang-Keun;Kim Ki-Ok;Kim Young-Kyung;Kim Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.439-445
    • /
    • 2004
  • The purpose of this study was to evaluate the influence of plugger penetration depth on the apical extrusion of root canal sealer during root canal obturation with Continuous Wave of Condensation Technique. Root canals of forty extracted human teeth were divided into four groups and were prepared up to size 40 of 0.06 taper with ProFile. After drying. canals of three groups were filled with Continuous Wave of Condensation Technique with System $B^{TM}$ and different plugger penetration depths of 3. 5, and 7 mm from the apex. Canals of one group were filled with cold lateral compaction technique as a control. Canals were filled with non-standardized master gutta-percha cones and 0.02 mL of Sealapex. Apical extruded sealer was collected in a container and weighed. Data was analyzed with one-way ANOVA and Duncan's Multiple Range Test. 3 and 5 mm penetration depth groups in Continuous Wave of Condensation Technique showed significantly more extrusion of root canal sealer than 7 mm penetration depth group (p < 0.05). However, there was no significant difference between 7 mm depth group in Continuous Wave of Condensation Technique and cold lateral compaction group (p < 0.05). The result of this study demonstrates that deeper plugger penetration depth causes more extrusion of root canal sealer in root canal obturation by Continuous Wave of Condensation Technique. Therefore, special caution is needed when plugger penetration is deeper in the canal in Continuous Wave of Condensation Technique to minimize the amount of sealer extrusion beyond apex.

A study on the optimal equation of the continuous wave spectrum

  • Cho, Hong-Yeon;Kweon, Hyuck-Min;Jeong, Weon-Mu;Kim, Sang-Ik
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.6
    • /
    • pp.1056-1063
    • /
    • 2015
  • Waves can be expressed in terms of a spectrum; that is, the energy density distribution of a representative wave can be determined using statistical analysis. The JONSWAP, PM and BM spectra have been widely used for the specific target wave data set during storms. In this case, the extracted wave data are usually discontinuous and independent and cover a very short period of the total data-recording period. Previous studies on the continuous wave spectrum have focused on wave deformation in shallow water conditions and cannot be generalized for deep water conditions. In this study, the Generalized Extreme Value (GEV) function is proposed as a more-optimal function for the fitting of the continuous wave spectral shape based on long-term monitored point wave data in deep waters. The GEV function was found to be able to accurately reproduce the wave spectral shape, except for discontinuous waves of greater than 4 m in height.

A GNSS Interference Detection Method Based on Multiple Ground Stations

  • Kim, Sun Young;Kang, Chang Ho;Yang, Jeong Hwan;Park, Chan Gook;Joo, Jung Min;Heo, Moon Beom
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.1 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • For a GNSS receiver's robustness against RFI and the high accuracy of navigation solution in GNSS, interference source detection and mitigation are needed. In this paper, an adaptive lattice IIR notch filter is employed to track single-tone continuous wave and swept continuous wave interference signals, and an interference detection method is proposed. Furthermore, this paper presents interference source characterization algorithm using multiple ground stations' interference detection results. The measurement of the signal powers from each ground station is used to build weighting factors to estimate the type of the interference. The performance of interference detection algorithm is simulated for scenarios of GPS signal in the presence of single-tone continuous wave interference and swept continuous wave interference.

Stimulated Brillouin scattering in optical fiber for pulsed lights compared to continuous wave lights (광펄스신호와 연속광원을 이용한 광섬유내의 stimulated Brillouin scattering 비교 연구)

  • 이한협;최현범;이동한;남성현;김대연;윤형규
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.338-342
    • /
    • 2003
  • We have studied the properties of stimulated Brillouin scattering (SBS) in an optical fiber using optical pulses and continuous wave light. We find that the thresholds for SBS are the same when the averaged power of pulse light is the same as the power of cw light. From this result, the SBS threshold of pulse light can be deduced from that of continuous wave light, which can be obtained easily and accurately.

A Study On The Doppler Radar Of Range Measurement On Electro-Optical Tracking System (광학추적장비의 거리측정 도플러 레이더에 관한 연구)

  • Park, Doo-Jin;Noh, Young-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.700-702
    • /
    • 2016
  • The Doppler Radar that mounted on Electro Optical Tracking System has been operated to measure range and velocity during the initial mission of space launch vehicle at Naro space center. In this paper, we mentioned configuration of MFCW(Multi frequency Continuous Wave) and FMCW(Frequency Modulation Continuous Wave) Doppler Radar on Electro Optical Tracking System and described method of range measurement.

  • PDF

The Effects of Pain and Range of Motion by Continuous Wave Ultrasound and Pulsed Wave Ultrasound on Patient with Temporomandibular Joint Disability (측두하악관절장애 환자에서 연속초음파와 맥동초음파 적용이 통증과 관절가동범위에 미치는 효과)

  • Moon, Hyun-Ju;Seo, Hyun-Kyu;Gong, Won-Tae
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.1-11
    • /
    • 2007
  • Purpose: The purpose of this study was to determine the effect of continuous wave ultrasound and pulsed wave ultrasound that influence changes in pain and range of motion when applied to patients with temporomandibular joint disability. Methods: The subjects of the study were 40 selected patients who had been diagnosed with temporomandibular joint movement restriction and had endured pain for more than two weeks. These patients had visited K orthopedic surgery in Deagu measured from October 1, 2004 to March 31, 2005. The subjects were divided into two groups with 20 patients each. The one group was applied to continuous wave ultrasound and the other group was applied to pulsed wave ultrasound at a dosage of 1.5 W/$cm^2$ for a duration of 5 minutes and eight times for two weeks. The pain perception degree were measured by using Visual Analogue Scale(VAS) and the range of motion was measured by using a rule for each group. Results: The results obtained were as follows The change in the pain perception degree were statistically significant in both group(p<0.05) ; however, the continuous wave ultrasound group showed more difference in the average decrease in the pain perception degree than did the pulsed wave ultrasound group. Both groups showed significant results regarding changed in the range of motion(p<0.05) ; Comparing the difference in the average of the range of motion between the two groups, came back from normal the range of motion of temporomandibular joint at the both groups. Conclusion : Based on the results of this study, we found that both groups showed decreased pain and increased the range of motion, but the continuous wave ultrasound method had a higher therapy effect pain and the range of motion than the pulsed wave ultrasound method to patients with temporomandibular joint disability. With such finding, we expect that according to ultrasound therapy applicant method can be helped usable accurately to patients with variety symptoms temporomandibular joint disability.

  • PDF

The S-wave Velocity Structure of Shallow Subsurface Obtained by Continuous Wavelet Transform of Short Period Rayleigh Waves (Continuous Wavelet Transform을 단주기 레일리파에 적용하여 구한 천부지반 S파 속도구조)

  • Jung, Hee-Ok;Lee, Bo-Ra
    • Journal of the Korean earth science society
    • /
    • v.28 no.7
    • /
    • pp.903-913
    • /
    • 2007
  • In this study, the researchers compared the S-wave velocity structures obtained by two kinds of dispersion curves: phase and group dispersions from a tidal flat located in the SW coast of the Korean peninsula. The ${\tau}-p$ stacking method was used for the phase velocity and two different methods (multiple filtering technique: MFT and continuous wavelet transform: CWT) for the phase velocity. It was difficult to separate higher modes from the fundamental mode phase velocities using the ${\tau}-p$ method, whereas the separation of different modes of group velocity were easily achieved by both MFT and CWT. Of the two methods, CWT was found to be more efficient than MFT. The spatial resolutions for the inversion results of the fundamental mode for both phase and group velocities were good for only a very shallow depth of ${\sim}1.5m$. On the other hand, the spatial resolutions were good up to ${\sim}4m$ when both the fundamental and the 1st higher mode poop velocities obtained by CWT were used for S-wave inversion. This implies that the 1st higher mode Rayleigh waves contain more information on the S-wave velocity in deeper subsurface. The researchers applied the CWT method to obtain the fundamental and the 1st higher mode poop velocities of the S-wave velocity structure of a tidal flat located in SW coast of the Korean peninsula. Thea the S-wave velocity structures were compared with the borehole description of the study area.

AN in vitro STUDY OF THE CORONAL LEAKAGE OF TWO ROOT CANAL FILLING TECHNIQUE USING ANAEROBIC BACTERIAL LEAKAGE MODEL (근관 충전된 치아에서의 혐기성세균을 이용한 치관부 미세누출측정에 관한 연구)

  • Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.490-494
    • /
    • 1999
  • The aim of this in vitro study was to investigate the coronal leakage of obligate anaerobes into root canals obturated with two different techniques. 48 extracted human teeth with straight, single root canals were prepared with crown-down technique with Profile under copious irrigation until the master apical file was size 40. The teeth were divided randomly into experimental groups (40 teeth) and control groups (8 teeth). In the experimental groups, 20 teeth were obturated with lateral condensation and other 20 teeth were obturated with continuous wave technique with System B. Coronal leakage of two root canal filing technique was evaluated using anaerobic bacterial leakage model with Fusobacterium nucleatum(ATCC 25586) for 60 days. The results were as follows 1. The incidence of bacterial leakage of experimental groups was 65% in group 1 (lateral condensation) and 60% in group 2 (continuous wave technique with System B). This difference was not statistically significant (P>0.05). 2. There was no statistically significant difference(P>0.05) in leakage score between group 1 (lateral condensation) and group2 (continuous wave technique with System B).

  • PDF

Damage Detection of Plate Using Long Continuous Sensor and Wave Propagation (연속형 센서와 웨이브 전파를 이용한 판 구조물의 손상감지)

  • Lee, Jong-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.3
    • /
    • pp.272-278
    • /
    • 2010
  • A method for damage detection in a plate structure is presented based on strain waves that are generated by impact or damage in the structure. Strain responses from continuous sensors, which are long ribbon-like sensors made from piezoceramic fibers or other materials, were used with a neural network technique to estimate the damage location. The continuous sensor uses only a small number of channels of data acquisition and can cover large areas of the structure. A grid type structural neural system composed of the continuous sensors was developed for effective damage localization in a plate structure. The ratios of maximum strains and arrival times of the maximum strains obtained from the continuous sensors were used as input data to a neural network. Simulated damage localizations on a plate were carried out and the identified damage locations agreed reasonably well with the exact damage locations.