An Experimental Study on the Strength Development of Porus Concerte according to the Mixing Ratio of Aggregate. (골재의 혼합비율에 따른 포러스콘크리트의 강도 증진을 위한 실험적 연구)

  • 김재환;유범재;백용관;김규용;박정호;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.253-256
    • /
    • 2000
  • The functions of porous concrete were influenced by continuous void, and it differ greatly from the distribution and size shape of continuous void in the same void volume. And porous concrete has been few used because the strength level of porous concrete is lower than that of ordinary concrete at the present time. So the purpose of this study is to increase the strength of porous concrete at the range of satisfying its function, analyze those effects of the mixing ratio of aggregate, affecting the development of its strength.

  • PDF

Evaluation of Air Permeability of Virtual Cement Paste Specimen with Linear Void Ratio Gradient Constructed using Stochastic Optimization (확률적 최적화를 활용한 연속적인 공극비 기울기를 갖는 시멘트 풀 가상 시편 제작 및 투기율 분석)

  • Kim, Se-Yun;Han, Tong-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.5
    • /
    • pp.463-469
    • /
    • 2016
  • In this study, a virtual specimen with a linear continuous gradient of void ratio (FGM: Functional Graded Material) is constructed using low-order probability functions of two real cement paste specimens. Two real specimens with difference void ratios are taken from X-ray CT to construct the virtual specimen. A virtual specimen with a gradient void distribution, whose average void ratio is between void ratios of two homogeneous real specimens, is constructed using a stochastic optimization approach. The void ratio distribution is assumed to be linear, and continuously varies in the vertical direction. In this study, a gradient term of void ratio is incorporated into the objective function as well as low-order probability functions from the previous research. To confirm the effect of gradient void distribution on the material response, air permeability is evaluated using finite element analysis. The analysis results are compared with experimental results, and confirm the effect of gradient void distribution on permeability.

An Expermental Study on the Properties of Porous Concrete Pavement (투수성 콘크리트 포장의 특성에 대한 실험적 연구)

  • 문한영;김성수;김홍삼;정호섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.329-334
    • /
    • 1997
  • Most of domestic pavement were non-permeable. However, in foreign country although it wasn't entirely satisfied, porous pavement was partially utilized with footpaths and soft-roadways. In this study, experiments were carried out to investigate the properties fundamental of porous concrete pavement. As a result of experiments, it was concluded that the coefficient of permeability was increased in proportion to continuous void ratio and decreased in proportion to S/a ratio and unit cement contents. On the other hand, the strength of porous concrete pavement was in inverse proportion to the void ratio.

  • PDF

Strength properties of Polymer-modified Sandwich panel core using non-structural lightweight Aggregate (비구조용 경량 골재를 충진재로 활용한 폴리머 개질 샌드위치 패널 심재의 강도 특성)

  • 노정식;도정윤;문경주;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.775-780
    • /
    • 2002
  • Sandwich panel made by foamed styrene and ployuretane has been used generally in the construction area because of the high thermal conductivity and light weight but they occur harmful gases to both bodies and environments in the high temperature over $50^{\circ}C$. So, the purpose of this study is to investigate the physical properties of light-weight panel using the non-structural lightweight aggregate as a part of the substitution of foamed styrene and ployuretane. This paper dealt with the effect of the addition of polymer dispersion such as SBR, St/BA-1 and St/BA-2 having polymer-cement ratio as 5, 10, 15% and the filling ratio of continuous void as 50, 60% on the strength of polymer-modified sandwich panel core. From the results, we could know that the compressive and flexural strength of the sandwich panel core using non-structural lightweight aggregate and polymer dispersion such as SBR, St/BA-1 and St/BA-2 tended to be increased with an increase in the polymer-cement ratio and the filling ratio of continuous void.

  • PDF

An Experimental Study on the Mechanical Properties of Porous Concrete Using Coal Ash and Polymer (석회석 골재를 사용한 강섬유보강 포러스콘크리트의 강도특성에 관한 실험적 연구)

  • Lee, Byung-Jae;Park, Seong-Bum;Jang, Young-Il;Jeon, Heum-Jin;Lee, Taek-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.685-688
    • /
    • 2008
  • Concrete is strong on the compressive property, but weak on the tensile and flexural properties. To improve these problems, the reinforcing bar is used in concrete. But porous concrete with steel fiber has a weak point when exposed to air, because porous concrete has the vast continuous void on its inside and steel fiber is easily rusted by air. For these reasons, this study investigated the void ratio, compressive strength, bending strength and bending toughness as steel fiber mixing ratio and target void ratio. From test results, actual void ratio and strength properties increased as the mixing ratio of steel fiber increase. In case the mixing ratio of steel fiber over the fixed ratio, strength is decreased. And from the toughness evaluation, compared to the porous concrete which isn't mixed with steel fiber, the deflection variation efficiency is remarkably improved. Consequently we can confirm the possibility of porous concrete with steel fiber for the secondary product and pavement material to improve strength and bending resistance efficiency.

  • PDF

The Study on the Physical and Mechanical Properties of Porous Concrete according to Compaction Method (다짐방법에 따른 포러스콘크리트의 물리.역학적 특성에 관한 연구)

  • Song, Jae-Lib;Park, Seung-Bum;Seo, Dae-Seuk;Lee, Jun;Jang, Young-Ill
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.813-816
    • /
    • 2006
  • Recently, improvements in the standard of living in industrial area require the establishment of a convenient residential environment in order to enhance the quality of living. To achieve such an environment, it is necessary to effectively reduce or prevent various environmental problems occurring in and around residential areas. Although conventional concrete has been regarded as a destroyer of nature, water and air can pass freely through concrete when it is made porous concrete by forming continuous void. In view of the harmony between nature and concrete, various research paths are being taken focusing on coarse aggregates to make porous concrete having continuous voids so as to improve water and air permeability, acoustic absorption, water purification, and applicability to vegetation. In this study, the Physical and Mechanical Properties of porous concrete according to compaction method analyzed by void ratio, coefficient of permeability and compressive strength.

  • PDF

An Experimental Study of Permeable Concrete Pavement for Application (투수성 콘크리트포장의 실용화를 위한 실험적 연구)

  • 문한영;김성수;정호섭
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.3
    • /
    • pp.165-173
    • /
    • 1998
  • 투수성 콘크리트포장은 우천시 도로포장 노면의 배수, 차량 주행 안전성의 향상 및 소음의 저감등을 목적으로 개발된 포장이지만 주행환경 및 도로주변과의 환경조화에도 기여한다. 일반적인 배수성 아스팔트 콘크리트포장에서는 투수계수 1$\times$10-2cm/sec를 목표로 정하고 있으나 본 연구에서는 투수성 콘크리트포장의 실용화를 위한 연구의 일환으로 투수계수1$\times$10-1cm/sec를 목표로 정하여 골재의 최대치수, 잔골재율 및 단위시멘트량을 변화시킨 투수성 콘크리트의 공극률, 연속공극률 및 투수계수와 제강도를 측정한 결과에 대하여 고찰하였다. 투수성 콘크리트의 목표투수계수 1$\times$10-1cm/sec 일 때 공극률 및 연속공극률은 각각 15 %와 12%정도이며, 압축강도는 240kg/$\textrm{cm}^2$정도의값을 나타내었으며, 골재의 최대치수가 10~13mm일 경우, 잔골재율 10~20%, 단위시멘트량 380 kg/$\textrm{cm}^2$정도가 적절한 배합으로 생각된다.

Property of Thermal Conductivity of Light Weight Panel Core Using Light-Weight Aggregate (인공경량골재를 이용한 경량패널 심재의 열전도 특성)

  • 이정국;도정윤;문경주;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.131-136
    • /
    • 2002
  • In recent year, it has been investigated on the reduction of mass of structures for the purpose of the larger space and the economy with the industry developing very fast and qualitatively. So the purpose of this study is to investigate the manufacture of light weight concrete panel using the artificial light-weight aggregate as a part of the substitution of foamed styrene and polyurethane because of narrow allocable temperature zone in use. The compressive strength, flexural strength, unit weight, absorption test and thermal conductivity were practised at 3, 7 and 28 days after manufacturing the light-weight concrete lot the panel core: the filling ratio of continuous void was defied as 40%, 50%, and 60% and water-cement rate was 35, 40 and 45%. As a result of this, it was revealed that the mixture derived from filling ration of void of 50% and water-cement ratio 40% were developing the best properties of the others.

  • PDF

An Experimental Study on the Evaluation of Porous Concrete using Industrial By-products of Planting Factory (산업부산물을 이용한 포러스콘크리트의 식생능력평가에 관한 연구)

  • 박승범;권혁준;서대석;윤덕열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.779-784
    • /
    • 2002
  • Porous concrete with a great deal of continuous porosity enables to contain water and to pass air freely through firmly hardened material, and allow necessary nutrients to reach roots of vegetation. Therefore, this paper deals with the voluntary properties and efficiency for planting of plant porous concrete. The results of experiment showed that void volumes were 17% to 31%, and compressive strength ranged between 80kgf/cm$^2$ and 180kgf/cm$^2$ when the ratio of the paste to aggregate was 0.3-0.5 When the aggregate size are 20-30mm, the paste to aggregate ratio is 0.3, and the length of Paranial Ryegress came up as 32cm. Ut supra the efficiency of planting goes through Paranial Ryegrass in result the length of plant are in compliance with void volume and aggregate size.

  • PDF

A Study on the Fundamental Properties of Permeable Concrete Using the Electric Arc Furnace Slag Aggregate (전기슬래그 골재를 활용한 투수성 콘크리트의 기초적 성질에 대한 연구)

  • 문한영;김성수;정호섭;안기용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.227-230
    • /
    • 1998
  • The void ratio, continuous void ratio, coefficient of permeability, compressive strength and tensile strength were considered according to the EAF(Electric Arc Furnace) slag replacement and sand percentage in permeable concrete used with EAF slag as aggregate. The sand percentage was directly proportional to the permeable coefficient, but inversely proportional to the compressive strength. When the compressive strength and coefficient of permeability were 230 kg/$\textrm{cm}^2$ and 1$\times$$10^{-1}$ cm/sec, the useful sand percentage was 8%. When the EAF slag replacement was 25%, the coefficient of permeability was the most low and compressive strength was the most high.

  • PDF