• Title/Summary/Keyword: continuous pipelines

Search Result 31, Processing Time 0.022 seconds

Vibrational Characteristics of Buried Gas Pipelines under Train Moving Loads (열차 이동하중에 의한 지중 매설 가스 배관의 진동 특성)

  • Won, Jong-Hwa;Kim, Moon-Kyum;Sun, Jin-Sun;Kim, Mi-Seung;Dang, N.Hai
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Recently, the vibration of underground structure due to high speed railway loads has been increased substantially as compared with middle and slow speed. The buried gas pipelines under continuous impact forces and repeated loading are more influenced by the vibrational loads than another pipelines. However, the static analysis was not enough to allow for the effect of vibrations because it uses impact factors for the design or analysis process. In this study, characteristics of Pipelines was quantitatively estimated through each conditions of soil covers and train speed, and the new vibration prediction is presented about the vibrational velocity.

  • PDF

Estimation of Plastic Bending Moment of Offshore Pipelines (해저관로의 대변형 굽힘에 의한 소성 모멘트 추정)

  • 이종현;최한석;이승건
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.2
    • /
    • pp.21-26
    • /
    • 2003
  • The reel-lay method of submarine pipelines a continuous string of pipe coiled onto a reel. Assembly of this pipe that is string is accomplished onshore by welding, and nondestructive testing is carried out prior to coiling the pipe. The total length of pipes on the reel depends on the reel and pipe diameters. Pipeline installation is accomplished by uncoiling, straightening the pipe, and laying out the pipe string onto the seabed as the barge moves forward. Installation associated with coiling and uncoiling is related to the bending moment and strain relationship of the pipeline, A highgrade pipe material is required when the reel-lay method is used. This paper is concerned with the highly plastic bending moment of the pipeline, including the effect of ovality. Moment calculation in the pipe is accomplished by the numerical method, including the variable ovalities during the plastic bending of the pipe string. The new calculation method of the high plastic bending moment was applied to the reel-lay method.

Simplified modelling of continous buried pipelines subject to earthquake fault rupture

  • Paolucci, Roberto;Griffini, Stefano;Mariani, Stefano
    • Earthquakes and Structures
    • /
    • v.1 no.3
    • /
    • pp.253-267
    • /
    • 2010
  • A novel simple approach is presented for the seismic analysis of continuous buried pipelines subject to fault ruptures. The method is based on the minimization of the total dissipated energy during faulting, taking into account the basic factors that affect the problem, namely: a) the pipe yielding under axial and bending load, through the formation of plastic hinges and axial slip; b) the longitudinal friction across the pipe-soil interface; c) the lateral resistance of soil. The advantages and drawbacks of the proposed method are highlighted through a comparison with previous approaches, as well as with finite element calculations accounting for the 3D kinematics of the pipe-soil-fault systems under large deformations. Parametric analyses are also provided to assess the relative influence of the various parameters affecting the problem.

Development of Permanent Reference Electrode for Corrosion Monitoring of Underground Metallic Structures (지중 금속구조물 부식감시를 위한 영구매설용 기준전극 개발)

  • Ha, Y.C.;Bae, J.H.;Ha, T.H.;Lee, H.G.;Lee, J.D.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.532-534
    • /
    • 2004
  • The advancement of electronics and telecommunication technologies has forced the risk management system for underground metallic structures to evolve into the remote monitoring and control system. Especially, facilities such as gas pipelines, oil pipelines and water distribution lines might make hazardous effect on human safety without continuous monitoring and control. As a result, pipeline engineers have applied cathodic protection system to prevent the degradation of their facilities by corrosion and carried out a periodic monitoring of the pipe-to-soil (P/S) potentials at numberous test boxes along their pipelines. The latter action on a road in downtowns, however, is so much dangerous that the inspectors should be ready to suffer the threatening of their lives and maintenance. In order to minimize these social costs and hazards, a stand-alone type corrosion monitoring equipment which can be installed in test box, store the P/S data for given Belied and send the data by wired/wireless telecommunications is under development. In order to obtain the exact P/S data, however, a reference electrode should be located as close to the pipeline as possible. Actually, the measured potential by a conventional portable reference electrode contain inevitably an IR drop portion caused by the current flow from the cathodic protection rectifier or the subway railroad. To minimize this error, it is recommended that the reference electrode should be buried within 10 cm from the pipeline. In this paper, we describe the design parameters for fabricating the permanent type reference electrode and the characteristics of the developed reference electrode.

  • PDF

Response Analysis of Buried Pipeline Subjected to Longitudinal Permanent Ground Deformation (종방향 영구지반변형에 대한 지중 매설관로의 거동특성 해석)

  • 김문겸;임윤묵;김태욱;박종헌
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.51-61
    • /
    • 2002
  • In this research, a numerical algorithm is developed for the response analysis of burined pipelines considering longitudinal permanent ground deformation(PGD) due to liquefaction induced lateral spreading. Buried pipelines and surrounding soil are modeled as continuous pipelines using the beam elements and a series of elasto-plastic springs represented for equivalent soil stiffness, respectively. Idealized various PGD patterns based on the observation of PGD are used as a loading configuration and the length of the lateral spread zone is considered as loading parameter. Numerical results are verified with other research results and efficient applicability of developed procedure is shown. Analyses are performed by varying different parameters such as PGD pattern, pipe diameter and pipe thickness. Through these procedures, relative influences of various parameters on the response of buried pipeline subject to longitudinal PGD are investigated.

The Study on the AC Interference of High Power Cable on Underground Gas Pipeline (전력케이블과 가스배관의 병행구간에 대한 교류부식 영향 검토 연구)

  • Bae, J.H.;Kim, D.K.;Ha, T.H.;Lee, H.G.;Kwak, B.M.;Lim, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.470-473
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power. Therefore, there has been and still is a growing concern (safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline. especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion, limitation of safety voltage and analysis of indiction voltage.

  • PDF

Monitoring of the Content of Imidazoline-Containing Corrosion Inhibitor

  • Zadorozhny, P.A.;Sukhoverkhov, S.V.;Markin, A.N.;Savin, K.I.;Prokuda, N.A.
    • Corrosion Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.161-166
    • /
    • 2017
  • The qualitative composition of active components of the corrosion inhibitor CGW-85567 was studied. It was found that С18:2 and С18:1 imidazolines and the corresponding imidazolin-amides are the major components. The HPLC/MS technique was developed for their determination in the water solutions of monoethylene glycol (MEG). Industrial application of the inhibitor showed that MEG solution retained high concentration of the inhibitor for a long time after ceasing its addition into pipelines. Low values of the partition coefficients (0.010-0.014) of imidazolines in the system "water solution of MEG (concentration of MEG 62-85% v/v) - gas condensate" have allowed to pass on from the technology of continuous pumping of the inhibitor into protected pipelines to the periodic dosing technology. Taking into account a long time of circulation in the system and high temperatures during MEG regeneration process possible degradation products of the inhibitor were studied. N, N-dimethyl-dodecanamine-1, and N, N-dimethyl-tetradecanamine-1 were identified as major degradation products of the corrosion inhibitor CGW-85567.

A Study on the System Integrity of Gas Pipeline by High Voltage Power Line in Submarine Tunnel (절점망 해석프로그램을 이용한 해저터널 내 고전압 전력케이블에 의한 가스배관의 안전성 평가 연구)

  • Bae Jeong-Hyo,;Ha Tae-Hyun,;Lee Hyun-Goo,;Kim Dae-Kyeong,
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.21-26
    • /
    • 2001
  • Because of the continuous growth of energy consumption, and also tile tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Recently, the results of assessment about a system integrity are needed in korea also when a gas pipeline is running parallel with high voltage power line in same submarine tunnel, Therefore, we analyze the system integrity(AC corrosion of pipe, melting of pipeline coating, safety of insulation flange, especially cathodic protection system which are rectifier and CI(cathodic Isolator)) resulting from the influence of high voltage power system.

  • PDF

Analysis of Induced Voltage on the Gas Pipeline at the Fault in a Underground Power Cables (지중전력케이블에서 고장발생시 인근 가스배관에 유도되는 전압 해석)

  • Bae J. H.;Kim D. K.;Kim K. J.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.26-32
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power Therefore, there has been and still is a growing concern(safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline, especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion limitation of safety voltage and analysis of induction voltage.

  • PDF

A review on vibration-based structural pipeline health monitoring method for seismic response (지진 재해 대응을 위한 진동 기반 구조적 관로 상태 감시 시스템에 대한 고찰)

  • Shin, Dong-Hyup;Lee, Jeung-Hoon;Jang, Yongsun;Jung, Donghwi;Park, Hee-Deung;Ahn, Chang-Hoon;Byun, Yuck-Kun;Kim, Young-Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.5
    • /
    • pp.335-349
    • /
    • 2021
  • As the frequency of seismic disasters in Korea has increased rapidly since 2016, interest in systematic maintenance and crisis response technologies for structures has been increasing. A data-based leading management system of Lifeline facilities is important for rapid disaster response. In particular, the water supply network, one of the major Lifeline facilities, must be operated by a systematic maintenance and emergency response system for stable water supply. As one of the methods for this, the importance of the structural health monitoring(SHM) technology has emerged as the recent continuous development of sensor and signal processing technology. Among the various types of SHM, because all machines generate vibration, research and application on the efficiency of a vibration-based SHM are expanding. This paper reviews a vibration-based pipeline SHM system for seismic disaster response of water supply pipelines including types of vibration sensors, the current status of vibration signal processing technology and domestic major research on structural pipeline health monitoring, additionally with application plan for existing pipeline operation system.