• Title/Summary/Keyword: continuous flow

Search Result 1,503, Processing Time 0.05 seconds

Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (Ⅳ). Continuous-Automated Determination of Sulfide Ion Using Tubular PVC Membrane Type pH Electrode (용해기체 분석용 기체감응막 이온선택성 전극 (제 4 보) 관형 PVC막 pH전극을 이용한 황화이온의 연속 · 자동화 정량)

  • Lee Heung Lark;Bae Zun Ung;Oh Sang-Hyub
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.638-643
    • /
    • 1992
  • The analytical response properties of two types of continuous flow-through electrode system as fulfide ion detectors are examined and directly compared their reponse characteristics under the optimal conditions. In both detection systems, observed peak potentials are logarithmically related to the sulfide ion concentration and at least twenty samples per hour can be determined. In the pH electrode method, the pH of the flowing recipient stream leaving the dialyzer was monitored. The designed system involves the use of continuous flow gas dialyzer in conjunction with the tubular polymer membrane electrode. In this method, optimal experimental conditions are recipient of mixture of $5.0 {\times} 10^{-5} M NaOH + 5.0 {\times} 10^{-3} M$ NaCl and diluent of 0.10 M $H_2SO_4$, and all flow rates of recipient stream, diluent stream, and sample are 1.0 ml/min. In the sulfide ion electrode method, a commercially available sulfide ion-selective electrode was used to detect sulfide ion in the flow-through cell. The optimal flow rates of sulfide anti-oxidant buffer (3.5 g ascorbic acid and 7.6 g $Na_2EDTA$ dissolved in 1.0 M NaOH solution 1 l) and sample were 1.4 ml/min and 1.0 ml/min, respectively.

  • PDF

A Study on Estimation of Fatigue Life of Aged Continuous Welded Rail using the Field Test (현장측정을 통한 노후 레일의 피로수명 평가에 관한 연구)

  • Kong, Sun-Yong;Sung, Deok-Yong;Kim, Jun-Hyung;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.352-364
    • /
    • 2007
  • It is essential to reduce track maintenance costs and to extend the periodic replacements of continuous welded rails based on accumulated passing tonnage. As recently train load decrease and rail joints wear down less, the periodic replacements of continuous welded rails can be extended. There are many kinds of rail damage like squat, head-check and corrugation. These can be taken nondestructive or naked eye test. So the periodic replacements of continuous welded rails based on accumulated passing tonnage were examine with focusing on a crack of rail bottom of continuous welded rail. Therefore, this study measure dynamic response of track by metro train load, it compute impact coefficient and track spring coefficient for estimating a condition of actual track system. Also, it is converted the measured stress waveform into stress frequency histogram by the rain-flow counting methods, and then the equivalence of stress is calculated. As apply s-n curve of a new welded rail, accumulated fatigue damage ratio of laid rail and remaining service lives is estimated. This study suggest a plan of the periodic replacements of continuous welded rails based on accumulated passing tonnage classified by the types of track system.

  • PDF

Shifting and Steering Performance Analysis of Hydromechanical Continuous Variable Transmission (정유압기계식 무단변속기의 변속조향성능해석)

  • 강서익
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.4 no.2
    • /
    • pp.25-30
    • /
    • 1995
  • The shifting and steering performance of the tracked vehicle with the hydromechanical continuous variable transmission is analyzed. The simulation results are closely similar to both the vehicle test result, As a result of hydromechanical transmission simulation, power circulation in 2nd and 3rd range is maximum 142% And power flow of mechanical part has the relationship with the effeciency of the vehicle and transmission.

  • PDF

A Study on the Flow Characteristics in T-type Rectangular Duct (T-TYPE 사각덕트내의 유동특성 연구)

  • Lee, Haeng-Nam;Park, Gil-Moon;Lee, Duck-Gu
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.702-707
    • /
    • 2001
  • The characteristics of flow in dividing regions are precise, therefore their classification is very important not only in industry but also in hydrodynamics. By now, many studies of flow in dividing regions have been performed, but flow characteristics that use visualization in dividing regions have not been studied. The present study of the PIV and the CFD exhibit average velocity distributions, kinetic energy distributions and total pressure distributions etc of the total flow field due to the development of the accurate visualization optical laser and of optical equipment. Also, PIV is accurate with the flows characteristics of the dividing region as continuous analysis is done using input equipment. The study analyzes average velocity vector field, average kinetic energy, x-axis stress distributions, average and total pressure distributions of dividing regions with flow for visualization of the PIV and the CFD measurement in a dividing rectangular duct.

  • PDF

A study on the development of CW(Continuous-Wave) Doppler system for measuring bi-directional blood flow information. (혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구)

  • Kang, Chung-Sin;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1239-1242
    • /
    • 1987
  • With the convention CW Doppler velocity meter, bi-directional velocities cannot be separated. The new CW Doppler system usee quadrature detection and phase rotation to Produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, can easily differentiate typical artery flow from vein flow. and measure both velocity characteristics qualitatively.

  • PDF

High-flow nasal cannula oxygen therapy in children: a clinical review

  • Kwon, Ji-Won
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.1
    • /
    • pp.3-7
    • /
    • 2020
  • High-flow nasal cannula (HFNC) is a relatively safe and effective noninvasive ventilation method that was recently accepted as a treatment option for acute respiratory support before endotracheal intubation or invasive ventilation. The action mechanism of HFNC includes a decrease in nasopharyngeal resistance, washout of dead space, reduction in inflow of ambient air, and an increase in airway pressure. In preterm infants, HFNC can be used to prevent reintubation and initial noninvasive respiratory support after birth. In children, flow level adjustments are crucial considering their maximal efficacy and complications. Randomized controlled studies suggest that HFNC can be used in cases of moderate to severe bronchiolitis upon initial low-flow oxygen failure. HFNC can also reduce intubation and mechanical ventilation in children with respiratory failure. Several observational studies have shown that HFNC can be beneficial in acute asthma and other respiratory distress. Multicenter randomized studies are warranted to determine the feasibility and adherence of HFNC and continuous positive airway pressure in pediatric intensive care units. The development of clinical guidelines for HFNC, including flow settings, indications, and contraindications, device management, efficacy identification, and safety issues are needed, particularly in children.

A Study on the Flow characteristics in dividing Rectangular ducts (사각분기 덕트내의 유동특성에 관한 연구)

  • 이행남;박길문;이덕구
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.270-275
    • /
    • 2001
  • The characteristics of flow in dividing regions are precise, therefore their classification is very important not only in industry but also in hydrodynamics. By now, many studies of flow in dividing regions have been peformed, but flow characteristics that use visualization In dividing regions have not been studied. The present study of the PIV and the CFD exhibit average velocity distributions, kinetic energy distributions and total pressure distributions etc of the total flow field due to the development of the accurate visualization optical laser and of optical equipment. Also, PIV is accurate with the flows characteristics of the dividing region as continuous analysis is done using input equipment. The study analyzes velocity vector field, turbulence kinetic energy, turbulence viscosity of dividing regions with flow for visualization of the PIV and the CFD measurement in a dividing rectangular ducts.

  • PDF

A Study on Unsteady Flow Characteristics of Closed Cavity with Obstacle (장애물을 갖는 밀폐공간의 비정상 유동특성에 관한연구)

  • 조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.176-183
    • /
    • 1999
  • This paper is aimed to investigate behaviour of vortex in 2-D step cavity with high Reynolds numbers$(3.2{\times}10^{3},\;10^{4},\;3{\times}10^{4},\;5{\times}10^{4}\;and\;7{\times}10^{4})$. The SOLA algorithm which is MAC type was adopted to solution method computing the flow field on irregular grid. In case of $Re=7{\times}10^{4}$ flow behavior is steady bu periodic unsteady sinusoidal fluctuation of local velocity and kinetic energy is found for $Re=10^{4}$ Continuous movements of small eddies in the secondary flow regions are discov-ered for $3{\times}10^{4}$ Generation of eddies and their active migrating behavior are detected over $Re=5{\times}10^{4}$ resulting in complete unsteady and non-linear flow characteristics Furthermore a typhoon-like vortex(TLV) appears intermittently and rotates along the separation regions and boundary layers.

  • PDF