• 제목/요약/키워드: continuous flow

검색결과 1,503건 처리시간 0.028초

자동연속흐름-흡광광도법과 DNPH-LC법에 의한 먹는물 중 포름알데히드 정량분석 비교 (Comparison of ACFAS method and DNPH-LC method for quantitative analysis of formaldehyde in Drinking water)

  • 이건호;윤인철;김영관;김종철;최금종;이택수
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.827-836
    • /
    • 2013
  • Due to the stringent drinking water quality, formaldehyde will be included in Korean drinking water standard from year 2014. However, its standard analytical method has not yet been established. This study compares two analytical methods, DNPH-LC and ACFAS with respect to their analysis principles, Method Detection Limit (MDL), Limit Of Quantitation(LOQ), precision, accuracy, reproducibility, convenience, number of samples analyzed per hour and analysis cost. These methods measure absorption intensity at 360 nm by using HPLC after DNPH-derivatization (DNPH-LC) and at 410 nm by using Automated Continuous Flow Absorption Spectrophotometer (ACFAS), respectively. Reproducibility was tested by repeating the analysis 7 times using a standard solution for each method. For DNPH-LC method, MDL was $0.5{\mu}g/L$, LOQ was $1.58{\mu}g/L$ with standard deviation of $0.16{\mu}g/L$. For ACFAS method, they were $0.27{\mu}g/L$, $0.85{\mu}g/L$L with standard deviation of $0.09{\mu}g/L$, respectively. Both methods satisfied the requirement set by the Korean drinking water quality standard. Complexity of sample pretreatment procedure for DNPH-LC method may cause large error and, consequently, the analytical result will depend on the level of skill of analyst. In contrast, ACFAS method which used only one reagent equipped with an automated injection device showed little analytical error. It costs about $5.00 and $1.00 for one sample to analyze by the DNPH-LC method and the ACFAS method, respectively. Compared to the DNPH-LC method, ACFAS method provided more reliable analytical results. In terms of convenience, easiness and analytical cost, ACFAS method was demonstrated to be superior to the DNPH-LC method. The results of this study suggested that the ACFAS method could be adapted as a proper method for determining formaldehyde content in drinking water.

혐기성 소화의 후처리로서 분리막의 여과특성 연구 (Characteristics of Membrane Filtration as a Post Treatment to Anaerobic Digestion)

  • 추광호;이정학;백운화;고의찬;김상원;고종호
    • 공업화학
    • /
    • 제3권4호
    • /
    • pp.730-738
    • /
    • 1992
  • 혐기성 소화액의 한외여과에 의한 후처리에서 분리막의 재질에 따른 여과특성을 연구하였다. 상이한 분리막의 여과특성을 정량적으로 평가하기 위해 저항 모델을 이용하였다. 소화액에 대한 플럭스의 양태는 초기의 물에 대한 분리막의 투과도에 무관하게 나타났다. 플루오로 폴리머 막의 경우에 유속의 증가에 따라 큰 플럭스의 향상을 보였는데 이것은 다른 분리막에 비해 막표면에 형성된 케이크층의부착성이 약해 쉽게 제거될 수 있음을 시사해준다. 장시간 운전에서 플럭스의 감소는 오염층 저항의 증가에서 뿐만아니라 분극층 저항의 증가에서도 기인되었는데, 이와같은 계속적인 분극층 저항의 증가는 미생물의 분해 및 성장에 따른 케이크층 내의 성상변화를 반영할 수 있다. 막표면이 친수성인 셀룰로오즈 막은 소수성인 폴리술폰 막에 비해 낮은 막오염도를 보여주었다. 감압을 통해 플럭스를 $5-10L/m^2/h$회복시킬 수 있었다. 세척단계에서 여과저항을 평가함으로써 15분의 단시간내에 세척이 완료됨을 알 수 있었다.

  • PDF

반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가 (Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room)

  • 문선여;황철홍
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.21-28
    • /
    • 2012
  • 비정상(unsteady) 화재성장이 발생되는 반밀폐된 구획에서 환기부족화재의 열 및 화학적 특성에 관한 FDS(Fire Dynamics Simulator)의 예측성능 평가가 수행되었다. 이를 위해 실규모 ISO 9705 표준 화재실의 출입구 폭이 0.1 m로 축소되었으며, spray 노즐을 통해 Heptane 연료유량은 선형적으로 증가되었다. 수치계산에 대한 신뢰도 확보를 위하여 동일 조건에서 수행된 실험결과와의 상세한 비교가 이루어졌다. 적절한 격자계를 이용한 FDS의 결과는 구획 내부의 온도 및 열유속(heat flux)은 비교적 잘 예측하지만, 비정상 CO 및 $CO_2$ 생성특성은 적절히 예측하지 못함을 확인하였다. 이러한 결과는 최근 수행된 유사조건의 정상상태 환기부족 구획화재에 대한 FDS 예측결과와 상반된 것으로서, 반밀폐된 구획화재 모델링에서 FDS를 이용한 비정상 CO 생성특성 예측에 상당한 주위가 요구됨을 확인하였다.

입상활성탄을 이용한 인공 조제 지하수내의 Cr(VI) 제거와 그 활성탄의 재생 (Cr(VI) Removal from Artificial Groundwater by Granular Activated Carbon and Regeneration of the Spent Carbon)

  • Ihnsup Han
    • 한국토양환경학회지
    • /
    • 제4권2호
    • /
    • pp.11-31
    • /
    • 1999
  • 회분식 및 연속류 주상 실험을 통해 인공 조제 지하수로부터 입상활성탄에 의한 6가크롬 (Cr(VI)) 제거에 대한 연구를 수행하였다. 실험에 적용된 변수로는 용액의 pH, 용존산소의 존재여부를 사용하였고 2가철(Fe(II))로 활성탄을 전처리한 것을 처리하지 않은 활성탄과 그 결과를 비교하였다. 용액의 pH를 4.0에서 7.5로 증가 시킴에 따라 무처리 및 Fe(II)로 전처리한 활성탄 모두에 흡착된 Cr(VI)의 양이 현저히 감소하였다. 용존산소가 배제 (무산소조건) 되었을 경우 Cr(VI) 제기량이 증가하였는데, 이는 Cr(VI)의 Cr(III)로의 환원 때문으로 추측된다. 그러나, Fe(II)에 의한 활성탄의 전처기는 Cr(Vl)제거에 거의 영향을 미치지 않았다 흡착된 Cr(VI)를 추출하기위해 0.01M $K_2$$HPO_4$와 침전 또는 흡착된 Cr(III)를 제거하기위해 0.02N $K_2$$HPO_4$로 세척하였는데, 이는 Cr(VI)로 흡착능이 고갈된 활성탄 재생의 한 방법으로 고려될 수 있으리라 사료된다. 재생된 활성탄은 본래의 활성탄보다 큰 흡착능을 보였는데, 그 이유는 Cr(VI)가 낮은 pH에서 흡착이 잘되며 또 Cr(III)로 환원되기 때문으로 사료된다. 산세척수중의 Cr(III)의 존재는 비교적 산성 조건하에서 Cr(VI)의 Cr(III)로의 환원을 보여주는 증거로 사료된다. 5회의 재생 및 재사용 실험에서 이 재생방법이 흡착능을 악화시키는 것 없이 지속적으로 사용될 수 있음을 알 수 있었다.

  • PDF

중국 연변 농촌지역의 조선족인구 감소와 지역성 변화 - 두만강변 조선족 농촌 마을을 중심으로 - (The Decrease of Korean Population and the Changes of Regional Characteristics in Rural Area of Yanbian Korean Autonomous Prefecture)

  • 여필순
    • 한국지역지리학회지
    • /
    • 제19권4호
    • /
    • pp.668-682
    • /
    • 2013
  • 본 연구는 경제개혁 이후 중국 연변조선족자치주내 조선족 인구감소의 메카니즘과 그 결과가 농촌지역에 미치는 영향 및 지역의 변화를 설명하기 위한 것이다. 중국의 시장경제체제의 도입, 호적제도의 약화 및 한 중 국교수립 이후 이동성향이 높아지고 통혼권과 거주지역이 확산되면서 조선족사회는 출산력수준의 급격한 저하와 젊은 층 및 여성 위주의 인구이동이 지속적으로 진행되었다. 이는 곧바로 농촌인구의 급격한 감소와 고령화로 이어져, 농업의 쇠퇴와 농촌지역의 조선족사회집단 해체, 기능약화, 민족교육의 위축 및 지도력 약화라는 결과를 초래하였다. 감소된 노동력을 보완하기 위한 농업경영상의 변화는 타지역 한족(漢族)농민들로 충당되었고 농업의 한족화 현상과 조선족에 비해 한족 농민들의 경제력 상승추세가 나타나고 있으며, 작물구성의 변화는 전통적 수전농업 체계에서 한전(旱田) 단작영 농체계로 특화되어 가는 경향이고, 노동력 효율적 분배가 가능한 상업적 작물이 인기가 높은 것으로 나타났다. 현재 조선족농업인구는 지속적으로 감소하는 추세이고 변화하고 있는 새로운 농업환경에 적절히 대응하지 못하는 문제들이 존재하며 이는 결국 조선족농촌마을이 소실될 위기에 놓여 있어 파격적인 정책지원 및 농촌개발정책의 수립이 중요하다.

  • PDF

질소시용수준이 베치-보리 혼파 사초의 질소고정 및 베치에서 보리로 질소이동에 미치는 영향 (Effect of N Application Rate on Fixation and Transfer from Vetch to Barley in Mixed Stands.)

  • 이효원;김원호;박형수;고한종;김수곤
    • 한국초지조사료학회지
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2005
  • With recent interest organic farming the use of legumes including vetch and clover to provide N to adjacent crops is increasing in Korea. In the present studies, we conducted a trial to investigate the effects of the application of N rate on nitrogen fixation and transfer from vetch to barley in mixed stands. The experiment was arranged in a randomized complete block design with three replications. Four different N rates(0, 75, 113 and 150/ha) was used and vetch+barley was broadcasted manually on 1.5 $\times$2 m plot in Oct. 2001. Half of urea and K$_{2}O, 200 Phosphate and 75 kg potash per ha were applied as basal dressing md half of N md 75 potash were used for topdressing to soil surface on MarctL 2002. The equivalent of 1kg ha$^{-1}$ at($^{15}$NH$_{4}$)$_{2}$SO$_{4}$ solution at 99.8 atom $\%$$^{15}$N excess was applied to the microplot in mid April. Forage was harvested from each plot at ground level and separated into barley and vetch. Total N content and It values of samples were determined using a continuous flow stable isotope ratio mass spectrometry(IsoPrime-EA. Micromass, UK.). The percentage of legume H fixed from atmospheric N2 were 95.0, 93.8, 94.4 and $84.8\%$ with increment of N levels. The percentage of N transfer from vetch to barley by N-difference method with increment of N fertilizer were from 58 to$49\%$ while 39 to $23\%$ in $^{15}$N-dilution method. The amount of transfer from vetch to barley were 87 to 68 kg/ ha with N level by N-difference moth여 and 58 to -56/ha with N application levels by $^{15}$N dilution method. The amount of nitrogen fixation per ha were from 150 kg / ha to 219 kg / ha by different method, but on the other side 49 to 105kg/ha by N$^{15}$-dilution.

Process Development for Effective Denitrification by Biofilter Using Loess Ball

  • CHOI DU BOK;LEE DONG BYUNG;CHA WOL SUK
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권2호
    • /
    • pp.412-420
    • /
    • 2005
  • In order to investigate factors affecting the denitrification in the F-STEP PROCESS using a loess ball as support media and Pseudomonas DWC 17-8, calcining temperature, loess ball size, pH, nitrate concentration, working temperature, and inhibitor were studied in batch mode using synthetic sludge. A 5- 10 mm of loess ball (960$^{circ}$ of calcining temperature) was the most suitable for denitrification. When the initial pH was increased from 3.0 to 7.0, the removal efficiency of nitrate was increased. Specifically, at initial pH of 7.0, the maximum removal efficiency of nitrate was 5.0 mg/min. When the initial concentration of nitrate was increased from 100 to 400 mg/l, the removal efficiency of nitrate was proportional to the concentration of nitrate. The maximum removal efficiency of nitrate was 5.72 mg/min at 400 mg/l of initial concentration. When the operating temperature was increased from 10 to 30$^{circ}$, the removal efficiency of nitrate was increased from 0.76 to 6.15 mg/min, and at above 40$^{circ}$ of operating temperature, it was decreased from 4.0 to 2.0 mg/min. Among the various inhibitors, higher than 10$^{-1}$ M of sodium azide abolished this reaction completely. When the KCN concentration was above 10$^{-1}$ M, the reaction was inhibited completely. In the case of 2,4-dinitrophenol and sodium sulphide, it was inhibited at above 10$^{-2}$ M completely. For testing the various flow orders of the F-STEP PROCESS for effective denitrification using practical wastewater, continuous experiments under the optimum conditions were carried out for 60 days. Among the various processes, the PROCESS A gave the highest efficiencies of denitrification, nitrification, and total nitrogen (TN) removal with 86.5, 89.5, and $90\%$, respectively. For scale-up in the PROCESS A, real farm wastewater was used and pilot tests carried out for 90 days. The denitrification efficiency was $97.5\%$, which was increased by $12.7\%$. The efficiencies of TN removal and nitrification were 96.6 and $70.0\%$, respectively. The removal efficiency of chemical oxygen demand (COD) was $63.7\%$, which was increased by $20\%$.

토양호흡의 측정과 국내 연구 현황에 대한 고찰 (A Review on Soil Respiration Measurement and Its Application in Korea)

  • 이은혜;임종환;이재석
    • 한국농림기상학회지
    • /
    • 제12권4호
    • /
    • pp.264-276
    • /
    • 2010
  • 본 연구는 토양호흡 측정방법을 소개하고 국내에서 관측된 토양호흡 자료를 고찰하고, 토양호흡 관측 자료 비교시 발생하는 문제점을 정리하였다. 토양호흡측정 방법은 측정원리에 따라 알칼리흡습법, 밀폐상법, 밀폐상역학법, 통기법으로 분류된다. 국내 토양호흡연구를 종합분석한 결과, 국내의 생태계에 적용 된 토양 호흡 측정 방법은 밀폐상역학법(62%), 알칼리흡습법(17%), 통기법(13%), 밀폐상법(8%)이 이용되었고 이러한 방법에 사용된 기기로는 LI-6400-09, EGM-3, EGM-4, 자동토양호흡측정기 등이 있다. 또한, 국내 토양호흡은 대부분 산림 생태계에 국한되어 관측이 이루어졌으며 관측된 평균 토양호흡은 130~900mg $CO_2\;m^{-2}h^{-1}$ 범위였다. 그러나 국내 토양호흡 관측이 산발적 불연속적으로 이루어져 축적된 자료가 매우 빈약한 실정이며, 토양호흡의 상호 비교 및 정량화를 위해 측정방법간의 비교 및 오차에 대한 검증된 연구가 없어 관측된 토양호흡값의 상호비교가 어려운 실정이다. 이로 인해 한반도 생태계의 탄소수지의 정확한 예측자료를 생산하기 위한 기초 자료로서의 가치를 저하시키고 있다. 한반도 탄소순환 메커니즘의 이해를 위해서는 보다 다양한 생태계의 토양호흡 관측이 시급히 이루어져야하며 토양호흡을 조절하는 환경요인과 상호작용에 관한 연구, 다양한 기상 조건을 포함하는 토양호흡 연구가 절실히 요구된다. 더불어 토양호흡의 발생원 별 구분에 대한 국내의 연구결과는 대단히 미약한 수준으로 토양호흡의 메카니즘이해와 정확한 탄소수지이해를 위해 발생원 별 토양호흡량 정량에 대한 연구가 이루어져야한다.

노후 코어형 필댐의 잠재 위해성 유형 분류 (Potential Hazard Classification of Aged Cored Fill Dams)

  • 박동순;오제헌
    • 지질공학
    • /
    • 제26권2호
    • /
    • pp.207-221
    • /
    • 2016
  • 최근 국내 필댐 및 저수지의 노후화가 급속도로 진행되고 있으며, 이에 따른 제체의 손상이나 붕괴사고가 잇따르고 있다. 그러나 필댐의 핵심적인 차수기능을 담당하는 코어층에 대한 열화와 잠재 위해성 분류에 대한 연구는 거의 미진한 실정이다. 본 연구에서는 노후화가 진행 중인 13개 기존 코어형 필댐에 대해(준공 후 경과년수 9-52년, 댐 높이 22-67 m), 무수보링에 의한 코어층 시추 지반조사와 표준관입시험, 2D 및 3D 전기비저항탐사, 물성·역학시험을 수행하여 공학적 기반의 잠재적 위해성 유형을 국내 최초로 분류, 제시하였다. 중심코어층에 대한 무수보링 시추 지반조사 결과, 코어재 잠재 위해성 유형을 국부적 포화대, 신속한 공내수 유입, 조립질 혼재 코어재, 상대적 저 강성의 네 종류로 분류하였다. 코어형 필댐의 잠재 위해성 유형 중국부적 포화대 유형은 코어존 내 유로의 성장 및 발달에 의한 내적침식의 가능성이 존재하므로 가장 위험한 위해성으로 분류 되었으며, 코어재의 열화 등급에 따라 적절한 차수능 회복을 위한 보수보강이 필요한 것으로 판단되었다. 그 외 세 가지 위해성 유형은 즉각적인 조치보다는 지속적인 모니터링과 정기 검사의 강화가 필요할 것으로 검토되었다. 본 연구대상 댐의 분석 결과, 준공 후 경과년수와 댐 코어재의 열화 양상과는 상관성이 크게 없는 것으로 나타났다. 본 연구 결과는 코어형 필댐의 노후화에 따른 댐의 안전관리와 성능개선에 있어 유용한 자료로 활용 가능할 것으로 판단된다.

Pilot Scale 연속식(連速式) 김치순간살균(瞬間殺菌) 장치(裝置)의 설계(設計) 및 제작(製作) (Design and Fabrication of a Pilot Scale Continuous Kimchi Pasteurizer)

  • 김공환;길광훈;전재근
    • 한국식품과학회지
    • /
    • 제16권1호
    • /
    • pp.83-89
    • /
    • 1984
  • 김치로부터 김치액(液)만을 분리(分離)하여 가열살균(加熱殺菌)한후 고형물(固形物)과 재혼합(再混合)하는 살균방식(殺菌方式)을 공업적(工業的) 김치생산(生産)에 적용(適用)시키기위해 pilot scale 연속식(連速式) 살균장치(殺菌裝置)를 설계(設計) 제작(製作)하여 설계기준(設計基準) 및 제작방법(製作方法)을 제시(提示)하였고 장치(裝置)의 열수지분석(熱收支分析)을 통해 장치(裝置)의 적정설계(適正設計) 및 제작(製作) 여부(與否)를 검토(檢討)하였다. 살균장치(殺菌裝置)는 김치액분리(液分離) 혼합부(混合部), 여열부(予熱部), 살균부(殺菌部), 여냉부(予冷部) 및 냉각부(冷却部)의 5개부(個部)로 구성(構成)하였다. 살균장치내(殺菌裝置內) 열교환부(熱交換部)의 소요관(所要菅)길이는 김치액(液)의 유속(流速) 5 kg/min, 총괄열전달계수(總括熱傳達係數) $1,000Kcal/m^2{\cdot}h{\cdot}^{\circ}C$로 가정(假定))하여 다음식(式) $W{\;}C_p{\Delta}T=U{\;}(2{\pi}RL){\Delta}T_m$에 의해 결정(決定)하였다. 관내(管內)에서의 물의 유속(流速)이 41/min일때 여열부(予熱部), 살균부(殺菌部), 여냉부(予冷部), 냉각부(冷却部)에서의 총괄열전달계수(總括熱傳達係數)는 각각(各各) 875, 1,398, 2,036, $288Kcal/min{\cdot}h{\cdot}^{\circ}C$이었으며 장치(裝置)의 설계온도(設計溫度)와 실제(實際) 실험치(實驗値)가 비교적 잘 일치(一致)하였다. 무우김치를 시료(試料)로 사용해 본(本) 장치(裝置)의 살균효과(殺菌效果)를 조사해본 결과 $25^{\circ}C$에서 김치 저장기간(貯藏期間)을 비살균구(非殺菌區勾)에 비해 현저히 연장(延長)할 수 있었다.

  • PDF