• Title/Summary/Keyword: continuous connection

Search Result 288, Processing Time 0.028 seconds

AN APPROXIMATION OF THE HANKEL TRANSFORM FOR ABSOLUTELY CONTINUOUS MAPPINGS

  • DRAGOMIR, N.M.;DRAGOMIR, S.S.;GU, M.;GAN, X.;WHITE, R.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제6권1호
    • /
    • pp.17-31
    • /
    • 2002
  • Using some techniques developed by Dragomir and Wang in the recent paper [2] in connection to Ostrowski integral inequality, we point out some approximation results for the Henkel's transform of absolutely continuous mapping.

  • PDF

델타 연산자를 이용한 통합형 FIR 필터 (Unified FIR filter using delta operator)

  • 서민상;권오규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.912-916
    • /
    • 1992
  • In this paper we investigate the connection between the continuous-time FIR(finite impulse response) filter and the corresponding discrtet-time FIR filter with fast sampling. The interconnection is established by formulating the discrete-time case using delta operators which has superior numerical properties in discretizing prcedure. The aim of this paper is to present a unified FIR filter using the .delta.-operator and to show that, as sampling interval .DELYA. aperator to zero, the results of this filter converge to the corresponding continuous-time reuslts, which implies that the unified FIR filter unifies continous-time FIR filter and discrtet-time FIR filter.

  • PDF

2개의 볼트를 가지는 PFRP 볼트연결부의 볼트배치에 따른 강도평가 (Strength Evaluation of Bolt Arrangement in PFRP Bolted Connection with 2 Bolts)

  • 이영근;김선희;원용석;천진욱;신광열;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제5권3호
    • /
    • pp.17-22
    • /
    • 2014
  • Fiber reinforced plastic (FRP) structural shapes are readily available in civil engineering applications. Among many manufacturing techniques used for FRP structural shapes, pultrusion process is one of the most widely used techniques in civil engineering applications. Pultrusion is a manufacturing process for producing continuous lengths of reinforced polymeric plastic structural shapes with constant cross-section. Pultruded composites are attractive for structural applications because of their continuous mass production with excellent mechanical properties. This paper presents the results of investigations pertaining to the bolted connection with two bolts for the pultruded FRP (PFRP) structural members. PFRP bolted connection tests were conducted with end distance to bolt diameter ratio ($e_1/d_b$) and two types of bolt pattern such as horizontal (Pattern A) and vertical arrangement (Pattern B). As a result, it is found that the $e_1/d_b$ is recommended as the ratio of 4. In addition, it is also found that the bearing strengths at failure of the Pattern A and Pattern B have a similar value.

Composite action in connection regions of concrete-filled steel tube columns

  • Johansson, Mathias
    • Steel and Composite Structures
    • /
    • 제3권1호
    • /
    • pp.47-64
    • /
    • 2003
  • In a nonlinear finite element study on the mechanical behavior of simple beam connections to continuous concrete-filled steel tube columns, two principally different connection types were analyzed: one with plates attached to the outside of the tube wall, relying on shear transfer, and one with an extended plate inserted through the steel section to ensure bearing on the concrete core. The load was applied partly at the connection within the column length and partly at the top, representing the load from upper stories of a multistory building. The primary focus was on the increased demand for load transfer to ensure composite action when concrete with higher compressive strength is used. The results obtained from the analyses showed that the design bond strength derived from push tests is very conservative, mainly due to the high frictional shear resistance offered by pinching and contraction effects caused by connection rotation. However, with higher concrete strength the demand for load transfer increases, and is hard to fulfill for higher loads when connections are attached only to the steel section. Instead, the connection should penetrate into the concrete core to distribute load to the concrete by direct bearing.

M-SCOTT CONVERGENCE AND M-SCOTT TOPOLOGY ON POSETS

  • Yao, Wei
    • 호남수학학술지
    • /
    • 제33권2호
    • /
    • pp.279-300
    • /
    • 2011
  • For a subset system M on any poset, M-Scott notions, such as M-way below relation,M-continuity,M-Scott convergence (of nets and filters respectively) and M-Scott topology are proposed Any approximating auxiliary relation on a poset can be represented by an M-way below relation such that this poset is M-continuous. It is shown that a poset is M-continuous iff the M-Scott topology is completely distributive. The topology induced by the M-Scott convergence coincides with the M-Scott topology. If the M-way below relation satisfies the property of interpolation then a poset is M-continuous if and only if the M-Scott convergence coincides with the M-Scott topological convergence. Also, M-continuity is characterized by a certain Galois connection.

Behavior and modeling of single bolt lap-plate connections

  • Rex, Clinton O.;Easterling, W. Samuel
    • Steel and Composite Structures
    • /
    • 제2권4호
    • /
    • pp.277-296
    • /
    • 2002
  • A research investigation of single bolt lap-plate connection load-deformation behavior is presented. Each important characteristic of this behavior is evaluated and two methods for analytically approximating the behavior are developed and presented. The first of these methods is a component method in which the behavior of the connection is modeled as a combination of the behavior of the parts. The second method utilizes a number of parametric relationships that relate the connection parameters to coefficients of two non-linear continuous analytical curves. The test results from four independent experimental programs that investigated the behavior of single bolt lap-plate connections are used in the development and verification of these methods.

플랫플레이트-기둥 접합부 강도발현에 관한 연구 (A Study on Strength of Flat Plate-Column Connections)

  • 강수민;이도범;김욱종;이지웅;박홍근;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.213-216
    • /
    • 2005
  • A numerical analysis was performed for interior connections of continuous flat plate to analyze the effect of design parameters such as column section shape, gravity load and slab span on the behavioral characteristics of the connections. Through the parametric study, the variations of shear stress distribution around the connection were investigated. According to the result of numerical analysis, as the length of the cross section of column in the direction of lateral load increases and gravity load increases, the effective area and the maximum shear strength providing the torsional resistance decrease considerably. And as the slab span loaded with relatively large gravity load increases, the negative moment around the connection increases and therefore the strength of connection against unbalanced moment decreases.

  • PDF

Ad Hoc 망에서 링크 핸드오버 방안 (Link Handover Scheme in Ad Hoc Networks)

  • 박상준;김형종
    • 한국시뮬레이션학회논문지
    • /
    • 제13권2호
    • /
    • pp.53-63
    • /
    • 2004
  • In ad hoc networks, the link survivability is firstly considered if a routing between two mobile nodes takes place through wireless environments, because all of mobile nodes participating in a connection dynamically move to anywhere. Also, mobile nodes have multi-role to implement a communication without a static system supported by wired networks. Hence, it is difficult that all mobile nodes continuously provide a reliable connection when the nodes operate each role for the connection. Therefore, it is desired to maximize the lifetime of a route as long as possible for the reliable communication. In this paper, we propose a proactive link management scheme that can provide the continuous route supported by the link handover. It consider the wireless link quality and the power lifetime of a node so that the link handover is implemented for the link survivability without disconnecting the route on the communication.

  • PDF

불균형 휨모멘트를 받는 플랫 플레이트-기둥 외부접합부의 강도 (Strength of Exterior Flat Plate-Column Connections Subjected to Unbalanced Moment)

  • 최경규;박홍근
    • 콘크리트학회논문집
    • /
    • 제15권3호
    • /
    • pp.470-481
    • /
    • 2003
  • 플랫 플레이트 구조의 외부접합부는 편심전단에 대해 비대칭형의 위험단면을 가지고 있으며, 위험단면의 길이가 내부접합부 보다 작고 중력하중과 횡하중 모두에 의해 편심전단응력이 발생하게 되므로 뚫림전단파괴에 대해 대단히 취약하다. 외부접합부의 거동은 대단히 복잡하며 또한 구조해석에서 사용하고 있는 강도모델이 부적합하기 때문에, 현 설계기준은 실험결과를 정확히 설명하고 있지 못하다. 본 연구에서는 이러한 현 설계기준의 미비점을 보완하기 위하여 슬래브-기둥 외부접합부에 대해 비선형유한요소해석을 수행하였다. 외부접합부에서는 횡하중의 재하방향에 따라 거동 및 최대강도가 상이하며, 해석결과에 근거하여 하중재하방향 별로 외부접합부에 대한 강도모델을 제안하였다. 제안된 강도모델은 실험결과와의 비교를 통해 검증되었다.

Task-Oriented Manipulabi1ity Measure를 이용한 이동매니플레이터의 연속작업 수행 (Continuous Task Performance for Mobile Manipulator Using Task-Oriented Manipulability Measure)

  • 진기홍;강진구;주진화;허화라;이장명
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.401-401
    • /
    • 2000
  • A mobile manipulator-a serial connection of a mobile robot and a task robot is redundant by itself. Using its redundant freedom, a mobile manipulator can move in various modes, and perform dexterous tasks. An interesting question,

  • PDF