• Title/Summary/Keyword: continuous chromatography

Search Result 84, Processing Time 0.026 seconds

Analysis of High-Value Materials through Continuous Cultivation System from Pre-and Post-Milking of Chlorella protothecoides (Chlorella protothecoides의 밀킹 전후 연속 배양 시스템을 통한 유용물질 분석)

  • Jeong, Yu Jeong;Kim, Seong Hak;Lee, Won Young;Kim, Sung Chun
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.10 no.2
    • /
    • pp.73-82
    • /
    • 2018
  • Chlorella are source of valuable compounds as lipids, proteins, carbohydrates, bioactive compounds. To continuous obtain the high-value materials of Chlorella protothecoides, we performed continuous cultivation after applying milking techniques to C. protothecoides grown with culture for 7 days in optical panel bioreactor (OPBR) system. Fatty acid and lutein in extracts from pre- and post-milking of C. protothecoides were analyzed using gas chromatography and high performance liquid chromatography, respectively. C. protothecoides were rich in unsaturated fatty acids with a high content of oleic acid(C18:1), which is suitable as a biofuel feedstock. The fatty acid content in pre- and post-milking of C. protothecoides was decreased from 126.424mg/g d.w. to 119.341mg/g d.w, and the lutein content decreased from 0.258mg/g d.w. to 0.178mg/g d.w. The results of this study demonstrate the feasibility of milking C. protothecoides for production of lipids for biofuels production. It was confirmed that microalgae can continuously obtain lutein present in a trace amount through a continuous culture from milking.

Development of Continuous Flow Microwave Digestion Procedures for Analysis of Trace Metal in Water Using Ion Chromatography

  • Youn Doo Kim;Gae Ho Lee;Hyung Seung Kim;Dong Soo Kim;Kwang Kyu Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.9
    • /
    • pp.786-791
    • /
    • 1994
  • A simple and rapid sample pretreatment process necessary for determination of metal oxides in water was proposed. Samples were injected into the continuous-flow tube installed inside the microwave oven and the treated samples were cooled before entered to the Ion Chromatography (IC) or Inductively Coupled Plasma (ICP). By coupling this microwave digestion system with IC or ICP, a fully automatic analytical procedures may be easily established. In this study, two different types of digestion methods were considered; the open tubing method (OTM) and the restraint tubing method (RTM). The RTM was proved to be 3 times faster in digestion period and 10 times higher in detection range than the OTM. Validation of proposed sample digestion system was carried out by using an ICP. The results showed that both of continuous-flow methods, the OTM and the RTM were comparable in accuracies with the conventional batch-type vessel digestion method.

괄루근으로부터 분리한 다당류의 화학 및 활성

  • 이정규
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1993.04a
    • /
    • pp.45-45
    • /
    • 1993
  • 괄루근으로부터 분리된 다당류에 대하여 continuous gel electrophoresis, SDS-Polyacrylamide gel eletrophoresis, ion exchange column chromatography, Hydroxyapatite column chromatography 및 Gel filtration등의 방법을 이용하여 다음과 같은 결과를 얻었다. 1) 황산암모늄 분별침전법에 의한 렉틴의 정제도는 초추출물의 4.85배이며 DEAE Sephadex A-50 column chromatography법에 의한 정제도는 24.17배로 나타났고, 마지막 정제단계인 Sephacryl S-200 gel filtration에 의한 정제도는 47.34배로 나타났다. 2) 정제된 렉틴의 분자량은 60,000da1ton으로 나타났다. 3) 사람의 혈액형에 따른 응집효과는 90-100%로 특이성은 없었다.

  • PDF

SMB 크로마토그래피를 이용한 loxoprofen racemate의 분리

  • Yun, Tae-Ho;Kim, In-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.549-553
    • /
    • 2003
  • SMB(simulated moving bed) chromatography system has been developed to realize continuous separation and save solvent consumption for binary mixture such as chiral compounds in especial. The parameters of SMB chromatography system can be calculated from mass balance equations of true moving bed chromatography, and they are used in design of 6-column SMB chromatography. We can separate 1'R-25 and 1'S-2S enantiomers as a raffinate product in 95% of purity using assembled SMB chromatography system.

  • PDF

SMB 크로마토그래피를 이용한 광학이성질체의 분리

  • Yun, Tae-Ho;Park, Hui-Jun;Kim, In-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.506-510
    • /
    • 2003
  • SMB(simulated moving bed) chromatography system has been developed to realize continuous separation and save solvent consumption for binary mixture in especial. The parameters of SMB chromatography system can be calculated from mass balance equations of true moving bed chromatography, and they are used in design of 6-column SMB chromatography. We can separate S-ketoprofen enantiomer as a raffinate product in 85% of purity and 0.3mg/ml using assembled SMB chromatography system.

  • PDF

Separation of Chiral Compound Using SMB Chromatography (SMB 크로마토그래피를 이용한 Chiral 화합물의 분리)

  • 윤태호;김인호
    • KSBB Journal
    • /
    • v.15 no.6
    • /
    • pp.541-547
    • /
    • 2000
  • Simulated moving bed (SMB) chromatography has been investigated in order to separate chiral compounds for pharmaceutical use. SMB utilizes the principle of true moving bed (TMB) chromatography, and has the advantages of low solvent usage, flexible configuration of columns and hardwares, and high productivity of the chiral compounds over the TMB. Large scale separation of xylene isomers and saccharides has been conducted since 1960s. However, the application of SMB in the fine chemical industries is still in the infant stage. The study of SMB for the chiral compounds production was initiated in the mid 1990s and further researches are actively undergoing. This review summarizes the principle of SMB as well as the chemistry of chiral stationary phase and chiral compounds.

  • PDF

Continuous Separation of Lysozyme from Egg White by Ion Exchange Column Chromatography (이온교환 칼럼 크로마토그래피를 이용한 난백에서 Lysozyme의 연속추출)

  • Park, Seong-Joon;Kim, Hyeon-Seok;Kim, Hyean-Wee;Ahn, Tae-Hoe;Park, Ki-Moon;Choi, Chun-Un
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.711-715
    • /
    • 1990
  • Continuous column chromatographic separation of lysozyme from egg white was investigated. A weak acid type cation exchange resin, Duolite C-464, was used because of high lysozyme recovery and ease of column operation in this experiment. The resin was equilibrated at $pH\;7.9{\pm}0.1$ in Na+form. Continuous lysozyme separation was processed by repeating cycles(one cycle : resin equilibration, flow egg white, rinse, lysozyme elution) in automated preparative Liquid Chromatography(LC) system(column size ; i.d. 50 mm, resin bed volumn ; 1020 ml). At comparison of UV levels in rinse end point and elution end point of every cycle, the UV levels of rinse end point are maintained below 30% for 19 cycles and that of elution end point are also maintained below 30% for 17 cycles, stably, but was increased above 50% after 18 cycle. That indicated the eluting ability of lysozyme was reduced conspicuously after 18 cycle in continuous cycling process. The recovery of lysozyme was maintained above 90% from one to 17 cycle, but was decreased to 72% and 65% in 18 cycle and 19 cycle, respectively.

  • PDF

Particle Separator using Radiation Force (광력을 이용한 입자 분리 장치)

  • Kim, Sang-Bok;Yoon, Sang-Youl;Kim, Sang-Soo;Sung, Hyung-Jin
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.55-58
    • /
    • 2007
  • To improve the conventional optical chromatography, the continuous particle separator, the cross-type optical chromatography, is fabricated using micro-channel and fiber optics. A laser beam irradiates into the liquid solution containing particles in the perpendicular to the liquid flow direction. The different sized polystyrene latex micro-spheres, $2.0\;{\mu}m\;{\pm}\;0.02\;{\mu}m$, $5.0\;{\mu}m\;{\pm}\;0.05\;{\mu}m$, and $10.0\;{\mu}m\;{\pm}\;0.09\;{\mu}m$ diameter, are separated in cross-type optical chromatography. The separated particles are delivered to down stream in the micro-channel maintaining the retention distance continuously. The measured retention distances for different sized particles well agree with theoretical predictions.

  • PDF

Simulation of IgY(Immunoglobulin Yolk) Purification by SMB(Simulated Moving Bed) (SMB(Simulated Moving Bed)를 이용한 IgY(Immunoglobulin Yolk) 분리의 전산모사)

  • Song, Sung-Moon;Kim, In-Ho
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.798-803
    • /
    • 2011
  • IgY(Immunoglobulin Yolk) is a specific antibody in egg yolk, and it protects human body from virus and antigen. There are a lot of egg yolk components such as lipoprotein and protein. To separate IgY, HPLC(High Performance Liquid Chromatography) and precipitation were used in a batch mode and SMB(Simulated Moving Bed) was adopted for continuous purification of yolk proteins. IgY and other proteins in yolk were separated by using three-zone SMB chromatography. Before performing SMB experiments, batch chromatography and PIM(pulse input method) were performed to find operation parameters and adsorption isotherms. The results of batch chromatography were compared with simulated results using Aspen chromatography. To find the most suitable separation condition in SMB chromatography, simulations in $m_2$-$m_3$ plane on the triangle theory were carried out. $m_2$ = 0.18, $m_3$ = 1.0 and ${\Delta}$t = 419 s are the best conditions for the highest purity of IgY. With this operating parameters(flow rate in three zone and switching time), the purity of raffinate results in 98.39% from Aspen chromatography simulation. Most of the simulation reached steadystate within second recycle.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.