• Title/Summary/Keyword: contamination performance

Search Result 363, Processing Time 0.02 seconds

A Study on Solar Cell Wafer Contamination Diagnostic and Cleaning (태양전지용 웨이퍼의 오염 분석 및 세정에 관한 연구)

  • Son, Young-Su;Ham, Sang-Yong;Chai, Sang-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.23-29
    • /
    • 2014
  • We have studied on ozonate water cleaning mechanisms to apply in manufacturing process of 156 mm silicon wafer which is used in the solar cell fabrication. We have analyzed contamination sources on wafer surface which causes poor quality and performance of products in fabrication process, and examined cleaning process using ozonate water to eliminate it. Contamination sources consist of remaining material like organic matter in slurry and detergent and particles in sawing wire. Using this novel technology it is possible for the solar cell wafer to clean with low cost, high performance, and eco-friendly.

The surface discharge performance of silicone rubber in the Salt fog test (Salt fog 시험에서 silicone rubber에서 발생하는 방전 전류의 특성)

  • 강성화;박영국;이광우;김완수;이용회
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.565-569
    • /
    • 1999
  • In these days, the silicone insulators have been increasingly studied and applied for outdoor insulators because it has superior characteristics than porcelain and glass insulators, which have been used for outdoor insulators. First of all, The excellent performance of the silicone rubber in polluted and wet conditions is attributed to the ability of the material to maintain the hydrophobicity of the surface in the presence of severe contamination and wet conditions. This is because of the presence of low molecular weight mobile fluid in the silicone rubber which diffuses to the surface and to above the contamination layer. But, the leakage current and some surface discharge occurs on surface of the composite polymeric insulation materials when the insulator is used for a long time with severe contaminative condition and it can lead the contamination flashover. So the leakage current and the discharge current are important to estimate the condition of the silicone rubber surface. In this paper, the average leakage current, the relation of surface discharge current and phase angle were study to investigate electrical conduction of silicone rubber surface with the salt fog condition.

  • PDF

The Status of Foodservice Operations and Perceived Performance of Management for School Dietitians in the Kyunggi Area (학교 급식 영양사들의 급식 관리 현황 및 직무 수행도 -경기 지역을 중심으로-)

  • Youn, Jong-Soon;Kim, Oi-Sook;Hwang, Seong-Yun;Chung, Yoon-Kyung;Kang, Kun-Og
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.19 no.2
    • /
    • pp.256-264
    • /
    • 2009
  • This study investigated the status of foodservice operations and perceived performance of management for school dietitians in the Kyunggi area. According to the results, the perceived performance of dietitians for cooking management presented an overall average of $3.90{\pm}0.61$, and carrying out examination and preservation of food was the highest among all sectors with $4.83{\pm}0.49$. The area of cross contamination marked a total average of $4.15{\pm}0.67$, and the perceived performance of serving management was lower than the sanitary management of cooking and cross contamination with $3.64{\pm}0.75$. The most recognized cause on foodborne illness was food materials (44.6%). Sanitary level, the temperature of most foods, and the personal hygiene of workers were also important causes of foodborne illness.

  • PDF

Correlation Analysis between Climate and Contamination Degree through Multiple Regression Analysis (다중회귀 분석을 통한 기후 및 오손도 간의 상관관계 분석)

  • Kim, Do-Young;Lee, Won-Young;Shim, Kyu-Il;Han, Sang-Ok;Park, Kang-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.49-52
    • /
    • 2003
  • The performance of insulators under contaminated conditions is the underlying and the most factor that determines insulation design for outdoor applications, Among the contamination factors, The sea salt is the most dangerous factor, and the salt factor have closed relation with climatic conditions, such as wind, temperature, humidity and so on, Effect of these factors to insulation system is different of each other, and need to show the correlation by multiple regression analysis techniques. In this paper, predicted and analyzed equivalent salt deposit density (ESDD) by change climatic condition through multiple regression analysis.

  • PDF

Leakage Current Properties Analysis of Outdoor Insulator on Climatic.Environmental Factor (기후.환경 인자에 의한 옥외 절연물의 누설전류 특성 분석)

  • Lee, Won-Yeong;Shim, Kyu-Il;Han, Sang-Ok;Park, Gang-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.27-30
    • /
    • 2002
  • In this paper, we were investigated leakage current properties of outdoor insulator on climatic environmental factor. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, we measured phase and leakage current of outdoor insulator using the temperature & humidity chamber. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity.

  • PDF

옥외에서 사용되는 배전급 폴리머 현수애자의 오손특성에 관한 연구

  • Lee, Byung-Sung;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.340-345
    • /
    • 2001
  • Because they have superior insulating properties and lower in price than their ceramic equivalents, polymeric insulators have been used in outdoor insulators. But polymeric insulators mainly using in an heavy contamination area of outdoor could be easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we dismounted polymeric insulators adhered contaminant in the field, and evaluated its electrical characteristics, CA, and ESDD. We also manufactured slurry mixed by some kaolin and salt for the artificial contamination test and measured the degree of contaminant, AC leakage current for these contaminated samples. Consequently, the adhered contaminants to its surface is likely to be affected the performance of insulation.

  • PDF

Detection of Foodborne Pathogens and Mycotoxins in Eggs and Chicken Feeds from Farms to Retail Markets

  • Lee, Minhwa;Seo, Dong Joo;Jeon, Su Been;Ok, Hyun Ee;Jung, Hyelee;Choi, Changsun;Chun, Hyang Sook
    • Food Science of Animal Resources
    • /
    • v.36 no.4
    • /
    • pp.463-468
    • /
    • 2016
  • Contamination by foodborne pathogens and mycotoxins was examined in 475 eggs and 20 feed samples collected from three egg layer farms, three egg-processing units, and five retail markets in Korea. Microbial contamination with Salmonella species, Escherichia coli, and Arcobacter species was examined by bacterial culture and multiplex polymerase chain reaction (PCR). The contamination levels of aflatoxins, ochratoxins, and zearalenone in eggs and chicken feeds were simultaneously analyzed with high-performance liquid chromatography coupled with fluorescence detection after the post-derivatization. While E. coli was isolated from 9.1% of eggs, Salmonella species were not isolated. Arcobacter species were detected in 0.8% of eggs collected from egg layers by PCR only. While aflatoxins, ochratoxins, and zearalenone were found in 100%, 100%, and 85% of chicken feeds, their contamination levels were below the maximum acceptable levels (1.86, 2.24, and 147.53 μg/kg, respectively). However, no eggs were contaminated with aflatoxins, ochratoxins, or zearalenone. Therefore, the risk of contamination by mycotoxins and microbes in eggs and chicken feeds is considered negligible and unlikely to pose a threat to human health.

Influence of Metallic Contamination on Photovoltaic Characteristics of n-type Silicon Solar-cells (중금속 오염이 n형 실리콘 태양전지의 전기적 특성에 미치는 영향에 대한 연구)

  • Kim, Il-Hwan;Park, Jun-Seong;Park, Jea-Gun
    • Current Photovoltaic Research
    • /
    • v.6 no.1
    • /
    • pp.17-20
    • /
    • 2018
  • The dependency of the photovoltaic performance of p-/n-type silicon solar-cells on the metallic contaminant type (Fe, Cu, and Ni) and concentration was investigated. The minority-carrier recombination lifetime was degraded with increasing metallic contaminant concentration, however, the degradation sensitivity of recombination lifetime was lower at n-type than p-type silicon wafer, which means n-type silicon wafer have an immunity to the effect of metallic contamination. This is because heavy metal ions with positive charge have a much larger capture cross section of electron than hole, so that reaction with electrons occurs much more easily. The power conversion efficiency of n-type solar-cells was degraded by 9.73% when metallic impurities were introduced in the silicon bulk, which is lower degradation compared to p-type solar-cells (15.61% of efficiency degradation). Therefore, n-type silicon solar-cells have a potential to achieve high efficiency of the solar-cell in the future with a merit of immunity against metal contamination.

Time Shifted Pilot Signal Transmission With Pilot Hopping To Improve The Uplink Performance of Massive MIMO System For Next Generation Network

  • Ruperee, Amrita;Nema, Shikha
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.9
    • /
    • pp.4390-4407
    • /
    • 2019
  • The paucity of pilot signals in Massive MIMO system is a vital issue. To accommodate substantial number of users, pilot signals are reused. This leads to interference, resulting in pilot contamination and degrades channel estimation at the Base Station (BS). Hence, mitigation of pilot contamination is exigency in Massive MIMO system. The proposed Time Shifted Pilot Signal Transmission with Pilot signal Hopping (TSPTPH), addresses the pilot contamination issue by transmitting pilot signals in non-overlapping time interval with hopping of pilot signals in each transmission slot. Hopping is carried by switching user to new a pilot signal in each transmission slot, resulting in random change of interfering users. This contributes to the change in channel coefficient, which leads to improved channel estimation at the BS and therefore enhances the efficiency of Massive MIMO system. In this system, Uplink Signal Power to Interference plus Noise Power Ratio (SINR) and data-rate are calculated for pilot signal reuse factor 1 and 3, by estimating the channel with Least Square estimation. The proposed system also reduces the uplink Signal power for data transmission of each User Equipment for normalized spectral efficiency with rising number of antennas at the BS and thus improves battery life.

Preemptive Failure Detection using Contamination-Based Stacking Ensemble in Missiles

  • Seong-Mok Kim;Ye-Eun Jeong;Yong Soo Kim;Youn-Ho Lee;Seung Young Lee
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.18 no.5
    • /
    • pp.1301-1316
    • /
    • 2024
  • In modern warfare, missiles play a pivotal role but typically spend the majority of their lifecycle in long-term storage or standby mode, making it difficult to detect failures. Preemptive detection of missiles that will fail is crucial to preventing severe consequences, including safety hazards and mission failures. This study proposes a contamination-based stacking ensemble model, employing the local outlier factor (LOF), to detect such missiles. The proposed model creates multiple base LOF models with different contamination values and combines their anomaly scores to achieve a robust anomaly detection. A comparative performance analysis was conducted between the proposed model and the traditional single LOF model, using production-related inspection data from missiles deployed in the military. The experimental results showed that, with the contamination parameter set to 0.1, the proposed model exhibited an increase of approximately 22 percentage points in accuracy and 71 percentage points in F1-score compared to the single LOF model. This approach enables the preemptive identification of potential failures, undetectable through traditional statistical quality control methods. Consequently, it contributes to lower missile failure rates in real battlefield scenarios, leading to significant time and cost savings in the military industry.