• 제목/요약/키워드: contamination performance

검색결과 363건 처리시간 0.023초

Contamination Control of Optical Observation Satellite

  • Lee, Chang-Ho;Lee, Choon-Woo;Cho, Young-Jun;Whang, Do-Soon
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.28.3-28.3
    • /
    • 2008
  • Contamination has the potential for degrading the performance of the optical payload beyond the limits defined by mission requirements, therefore it must be considered a risk to system performance and must be mitigated. To mitigate contamination problem, contamination budget is allocated according to the contamination requirements which is derived from contamination effect analysis. Once the contamination budget is allocated, prediction for on-ground and in-orbit contaminants amounts and cleanliness control is performed. In this article, typical contamination control for observation satellite is described.

  • PDF

옥외용 절연체 표면에서의 ESDD 측정과 내오손특성에 관한 연구 (A Study on Measurement of ESDD and Contamination Performance of Polymeric Outdoor Insulators)

  • 연복희;유형철;이현진;송정용;이태호;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.427-430
    • /
    • 2002
  • This paper presents on contamination performance of polymeric outdoor insulator with different contaminant accumulation. The ESDD (equivalent salt deposit density), tracking resistance and clean-fog test were performed to investigate the characteristics of contamination performance on polymeric outdoor insulator. Furthermore, we evaluated together with the porcelain samples for its comparison. It is found that ESDD of polymeric and porcelain insulator depends on the installation position. This surface accumulation of contaminant lead to the loss of surface hydrophobicity, expecially upper shed part of polymeric insulator. In addition, the effect of an artificial contaminant on the tracking resistance by inclined-plane method and leakage suppression ability under clean fog was surveyed. The time of tracking failure did not appear to change significantly with a much contaminant accumulation, while leakage current under clean-fog increased.

  • PDF

차선 이탈 경고 시스템의 성능 검증을 위한 가상의 오염 차선 이미지 및 비디오 생성 방법 (Virtual Contamination Lane Image and Video Generation Method for the Performance Evaluation of the Lane Departure Warning System)

  • 곽재호;김회율
    • 한국자동차공학회논문집
    • /
    • 제24권6호
    • /
    • pp.627-634
    • /
    • 2016
  • In this paper, an augmented video generation method to evaluate the performance of lane departure warning system is proposed. In our system, the input is a video which have road scene with general clean lane, and the content of output video is the same but the lane is synthesized with contamination image. In order to synthesize the contamination lane image, two approaches were used. One is example-based image synthesis, and the other is background-based image synthesis. Example-based image synthesis is generated in the assumption of the situation that contamination is applied to the lane, and background-based image synthesis is for the situation that the lane is erased due to aging. In this paper, a new contamination pattern generation method using Gaussian function is also proposed in order to produce contamination with various shape and size. The contamination lane video can be generated by shifting synthesized image as lane movement amount obtained empirically. Our experiment showed that the similarity between the generated contamination lane image and real lane image is over 90 %. Futhermore, we can verify the reliability of the video generated from the proposed method through the analysis of the change of lane recognition rate. In other words, the recognition rate based on the video generated from the proposed method is very similar to that of the real contamination lane video.

배전용 가스개폐기의 내 오손 성능향상 대책 (Anti-Contamination Capability of Gas Insulated Switch for Distribution Line)

  • 김주용;송일근;김찬영;한재홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.758-760
    • /
    • 1998
  • This paper provides the results of performance investigation of gas insulated switches(G/S) for distribution power system. In order to investigate anti-contamination capability of G/S we carried out electrical tests and material analysis on the body of G/S and it's accessories. Through this experiment we found out the lead cable of G/S had not anti-contamination capability and G/S had insufficient interval between each phase. In order to improve the performance of G/S for heavy contamination area it is indispensable to replace the lead cable to the new cable which has anti-contamination ability.

  • PDF

고분자전해질 연료전지에서 고분자 막과 전극의 철 이온 오염 및 산 세척 효과 (Iron Ion Contamination and Acid Washing Effect of Polymer Membrane and Electrode in Polymer Electrolyte Fuel Cell)

  • 유동근;박민정;오소형;박권필
    • Korean Chemical Engineering Research
    • /
    • 제60권1호
    • /
    • pp.20-24
    • /
    • 2022
  • 고분자전해질연료전지 (PEMFC) 장기사용과정에서스택요소의부식및공급가스의오염에의해막전극합체 (MEA)의 화학적 열화가 발생한다. 본 연구에서는 화학적으로 열화된 MEA를 산 세척해서 성능을 회복시킬 수 있는지 연구하였다. 철 이온을 오염시키고 황산 수용액으로 세척하여 PEMFC 셀에서 성능을 측정해 비교했다. 0.5 ppm의 철 이온 오염에 의해 약 25%의 성능 감소가 있었고 0.15 M 황산 세척에 의해 97.1% 성능회복이 가능했다. 고분자 막의 철 이온 오염에 의해 막 저항이 증가했고, 저농도 황산 수용액 세척에 의해 전극 촉매의 손실을 최소화하면서 막에서 철 이온을 세척함으로써 이온전도도가 회복되었다. PEMFC MEA의 화학적 오염에 의한 내구성 감소를 산 세척에 의해 해결할 수 있는 가능성을 확인하였다.

고분자 전해질막 수전해 막전극접합체의 양이온 오염에 따른 성능 저하 (Performance Degradation of Mea with Cation Contamination in Polymer Electrolyte Membrane Water Electrolysis)

  • 정혜영;최낙헌;임수현;윤대진;문상봉
    • 한국수소및신에너지학회논문집
    • /
    • 제28권4호
    • /
    • pp.331-337
    • /
    • 2017
  • Proton Exchange Membrane Water Electrolysis (PEMWE) is one of the most popular and widely used methods for hydrogen production. PEMWE contributes to eco-friendly system via its energy storage system application, hence making it environmentally friendly to use. However, its main drawback is contamination of proton exchange membrane during water electrolysis. Existing cation such as magnesium, calcium and the likes are the cause for membrane contamination. As a result, the cation contamination give rise to degradation of performance of electrolysis and the reverse electrolysis is effective method to remove cation.

Post-CMP Cleaning에서 PVA 브러시 오염이 세정 효율에 미치는 영향 (Effect of PVA Brush Contamination on Post-CMP Cleaning Performance)

  • 조한철;유민종;김석주;정해도
    • 한국전기전자재료학회논문지
    • /
    • 제22권2호
    • /
    • pp.114-118
    • /
    • 2009
  • PVA (polyvinyl alcohol) brush cleaning method is a typical cleaning method for semiconductor cleaning process especially post-CMP cleaning. PVA brush contacts with the wafer surface and abrasive particle, generating the contact rotational torque of the brush, which is the removal mechanism. The brush rotational torque can overcome theoretically the adhesion force generated between the abrasive particle and wafer by zeta potential. However, after CMP (chemical mechanical polishing) process, many particles remained on the wafer because the brush was contaminated in previous post-CMP cleaning step. The abrasive particle on the brush redeposits to the wafer. The level of the brush contamination increased according to the cleaning run time. After cleaning the brush, the level of wafer contamination dramatically decreased. Therefore, the brush cleanliness effect on the cleaning performance and it is important for the brush to be maintained clearly.

일개 상급종합병원에 근무하는 간병인의 의료관련감염 관리 수행도 및 손의 미생물 오염도에 영향을 미치는 요인 (Influencing Factors on the Performance of Healthcare-associated Infection Control and Microbiological Hand Contamination among Caregivers at a Tertiary Hospital)

  • 이희진;박은주;박미희;주혜영;서주위;전미양
    • 근관절건강학회지
    • /
    • 제26권3호
    • /
    • pp.241-250
    • /
    • 2019
  • Purpose: This study was conducted to identify influencing factors on the performance of healthcare-associated infection control and microbiological hand contamination among caregivers at a tertiary hospital. Methods: The participants of this study were 59 caregivers woring at a tertiary hospital. Data were collected from July 1 to 30, 2018. Data were analyzed using descriptive statistics, t-test, ANOVA, Scheffé test, Pearson's correlation coefficients and stepwise multiple regression by SPSS 23.0 Win program. Results: Multiple regression analysis revealed that factors influencing performance of healthcare-associated infection control were awareness (β=.63, p<.001) and the experience of infection-related education (β=-3.40, p=.042). Regression equations describing the performance of healthcare-related infection control were found to be appropriate (F=27.29, p<.001) and accounted for 68% of variance. Factors affecting the degree of microbiological hand contamination were work experience (β=-0.28, p=.026) and healthcare-related infection performance (β=-0.28, p=.029). A regression equation describing the microbiological hand contamination was appropriate (F=6.10, p=.004) and accounted for 42% of variance. Conclusion: The findings of this study suggest that it is necessary to increase performance of healthcare-associated infection control by caregivers. Also, educations for preventing healthcare-associated infection and guidelines for increasing compliance with healthcare-associated infection control are recommended to improve performance of healthcare-associated infection control.

인공위성의 오염 측정, 분석 및 관리 (Contamination measurement, Analysis & Control for Satellite)

  • 이상훈;홍석종;조혁진;서희준;문귀원
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.116-122
    • /
    • 2010
  • 우주환경에서 임무를 수행하는 인공위성의 경우, 조립, 시험, 운용시점까지 위성 표면에 흡착되는 오염물질을 최소화하기 위하여 전 기간 동안 세심한 주의를 기울여야 한다. 위성표면에 흡착된 미세한 오염물질은, 고진공 및 고온, 극저온이 반복되는 가혹한 우주환경 속에서 위성의 성능저하 및 효율의 손실을 가져올 수 있다. 예를 들어 위성 표면에 떨어진 입자오염은 별 추적장치의 오류를 발생시킴에 따른 위성 자세제어의 실패를 가져올 수도 있고, 표면에 흡착된 분자오염은 렌즈, 미러, 윈도우 등의 광학기기 및 주요 민감 표면에 작용하여 광학적 특성과 열제어 성능의 저하를 가져올 수 있다. 위성의 조립 및 시험을 관장하는 한국항공우주연구원에서는 위성의 오염물질에 대한 노출을 최소화하기 위해, 오염측정이 이루어지는 청정실을 운용하고 있는데, 본 논문에서는 청정실 및 진공챔버 내의 부유입자측정, 표면입자오염측정, 표면분자오염측정법을 소개하고 오염측정 결과에 대한 분석을 수행하였다.

배전용 피뢰기의 인공오손에 의한 누설전류의 고조파 분석 (Harmonics Analysis of Leakage Current due to Artificial Contamination of Distribution Arresters)

  • 박재준
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1306-1313
    • /
    • 2012
  • This paper reports the contamination performance of two distribution arresters (new and used ones) tested under three different contaminant conditions - clean fog, ESDD (equivalent salt deposit density) level (A, B, C, and D), and kaolin contamination conditions, and their leakage current, total leakage current, and component of the resistive leakage current were measured in order to diagnose arrester deterioration. The 3rd harmonics was larger than 5th and 7th ones for the arrester under the clean fog, and as the ESDD contamination level was applied, 5th one became relatively larger than 3rd one. Therefore, these results indicated that the resistive leakage current could be used for the diagnosis of the arresters.