• Title/Summary/Keyword: contamination degree

Search Result 338, Processing Time 0.026 seconds

Signal Classification of Electromagnetic Wave for Contaminated Degree on Polymer Insulator (고분자 애자 오손정도의 전자파 신호 분석)

  • Park, Jae-Jun;Choi, In-Hyuk;Jung, Myeong-Yeon;Lee, Seung-Wook;Seo, Euy-Won;Ka, Pyeong-Hyeon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.662-665
    • /
    • 2004
  • Recently, diagnosis techniques have been investigated to detect a partial discharge associated with a dielectric material defect in a high-voltage electrical apparatus However, the properties of detection technique of PD aren't completely understood because the physical process of PD. Therefore, this paper analyzes the process on Surface Discharge of Polymer Insulator using Wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time-frequency domain. As it is important to develop a non-contact method for detecting the Contamination Degree, this paper analyzes the electromagnetic waves emitted from PD using Wavelet transform. This paper experimentally shows the process of PD as a two-dimensional distribution in the time-frequency domain. This method is shown to be useful for detecting prediction of contamination degree.

  • PDF

A Study on the Arc Characteristics and Diagnosis of Electrical Contacts for Power due to Environmental Degree (환경오염도에 따른 전력용 전기접점의 아-크특성 및 진단에 관한 연구)

  • Lee, Jong-Ho;Hwang, Young-Han;Park, Hong-Tae;Lee, Kwang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.261-263
    • /
    • 1994
  • This paper deals with the on off arc characteristics of electromagnetic relay contacts contaminated by NaCl and $H_2SO_4$. In this paper, I have studied the characteristics of on-off voltage waveform. the contact errosion, contact surface analysis by SEM and EDAX under changed R-L parameter of testing circuit. After considers these result, I have tried to promote the diagnosis method and developed the contacts. As a results, (1) The arc duration and the numbers of arc occurrence characteristics are depended on contamination degree. The contamination degree is high when the arc characteristics is high. (2) Under clean condition, arc occurrence voltage, surge peak voltage, arc duration and the rate of contact errosion is lower than wet condition. (3) Surge peak voltage and arc duration is depended on L parameter. When L is High, the arc characteristics is high.

  • PDF

Concern and Improvement of the Ocean Environment by Vocational High School Students in a Seaside City (임해도시 실업계 고등학교 학생의 해양환경에 대한 관심과 개선방안)

  • KIM, Sam-Kon;Ok, Mi-Kyong
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.17 no.1
    • /
    • pp.1-17
    • /
    • 2005
  • The purpose of this study is to prepare the way for the prevention and improvement of the ocean environment pollution and destruction by researching and analyzing the degree of interests in the ocean environment which the students of seaside vocational high schools have. The concerns of this study are as follows: 1. The vocational high school students in the seaside cities of Busan and Pohang have recognized that the ocean is the object of the highest potential of development and that through the degree of their recognition that they should better preserve the ocean environment prior to a high degree of local seaside development. 2. Although they have recognized that the ocean environment has a great influence on the life of people, their interests in the environment is low. Also, it is shown that they get their knowledge and information through TV. 3. They've understood that the main factor of ocean contamination concerns the home and the causes of ocean contamination are sewage and waste material from daily life. Moreover, their answers reveal that they believe that they should participate in a sanitization activity for the ocean environment voluntarily and put trash into nearby trash cans as opposed to inconsiderately throwing away trash on the beach. 4. Their answers also show that they recognize the elements that can best preserve the ocean environment start at home and with government, and school services through experience activities are the most effective for the education of the ocean environment.

Effects of Inorganic Coagulants on Sizing and Contamination in Newsprint Mill (무기 응결제가 신문용지의 사이즈도와 공정오염에 미치는 영향)

  • Lee, Tai Ju;Seo, Jin Ho;Lee, Kwang Seob;Jeong, Sung Hyun;Ryu, Jeong Yong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.3
    • /
    • pp.40-46
    • /
    • 2015
  • For some Korean newsprint mill, addition level of aluminum sulfate has been reduced because sulfur from aluminum sulfate has detrimental effect on the efficiency of anaerobic water treatment. At this moment, an unexpected decrease in sizing degree of TMP mixed newspaper was occurred. The phenomena means that hydrophobic substance usually originated from TMP cannot be fixed on the paper. This study focused on effect of alum and PAC on sizing of paper and contamination. Also, substitutability of PAC was discussed as a possible alternatives of aluminum sulfate under anaerobic condition of water treatment. Evaluation of sizing degree and pitch deposit potential were performed at the varied addition level of PAC and aluminum sulfate. Hydrophobic substance mainly derived from TMP could be fixed on the surface of fiber by PAC. Fines retention was not changed by replacing aluminum sulfate with PAC. Additionally, fixing of hydrophobic substance without excessive agglomeration can be enhanced by PAC with low molecular weight. Consequently, sizing degree of newspaper and contamination of recycling process of ONP can be controlled by low molecular weighted PAC.

창원지역 지하수 수질과 DRASTIC에 의한 지하수 오염취약성 평가

  • 김무진;함세영;정재열;장성;차용훈
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.459-462
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in 12 administrative districts of the city of Changwon, using DRASTIC technique. DRASTIC was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. However, groundwater contamination in urban areas can also be related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is low as 0.40. The correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other factors such as groundwater withdrawal rate and well density per unit area with ratings and weights as well as the existing six DRASTIC factors.

  • PDF

Correlation Analysis between Climate and Contamination Degree through Multiple Regression Analysis (다중회귀 분석을 통한 기후 및 오손도 간의 상관관계 분석)

  • Kim, Do-Young;Lee, Won-Young;Shim, Kyu-Il;Han, Sang-Ok;Park, Kang-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.49-52
    • /
    • 2003
  • The performance of insulators under contaminated conditions is the underlying and the most factor that determines insulation design for outdoor applications, Among the contamination factors, The sea salt is the most dangerous factor, and the salt factor have closed relation with climatic conditions, such as wind, temperature, humidity and so on, Effect of these factors to insulation system is different of each other, and need to show the correlation by multiple regression analysis techniques. In this paper, predicted and analyzed equivalent salt deposit density (ESDD) by change climatic condition through multiple regression analysis.

  • PDF

The Survey about Toxic Material Contamination at the Streamwater around the Sudokwon Kandfill Area (수도권 매립지 주변 하천의 독성물질 오염실태 조사)

  • Kang, Chang-Min;Lee, In-Hyun;Jang, Won
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.565-572
    • /
    • 1998
  • This study estimate the degree of contamination in the streamwater around the Sudokwon landfill site. It was sampled at 10 sites in Jan., Apr., Jul. and Oct., 1996. There were analyzed five kinds of toxic chemical material-CN, AES, PCB, As, Org-p, and four kinds of heavy metal-Pb, Hg, Cd, $C^{+6}$ The result are 1)The COD was generally increased to compare before landfall, 2) The Org-P and PCB were not detected at all points, 3) The concentrations of Pb, $C^{+6}$ and As were lower than the environmental criteria values, 4) The CN, Hg and Cd were over envirommental criteria values. and so emergent regulation is needed, 5) The effects of the streamwater contamination were not only the leachate of the landfall, but also the small factories and agricultural land around the landfill.

  • PDF

옥외에서 사용되는 배전급 폴리머 현수애자의 오손특성에 관한 연구

  • Lee, Byung-Sung;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.340-345
    • /
    • 2001
  • Because they have superior insulating properties and lower in price than their ceramic equivalents, polymeric insulators have been used in outdoor insulators. But polymeric insulators mainly using in an heavy contamination area of outdoor could be easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we dismounted polymeric insulators adhered contaminant in the field, and evaluated its electrical characteristics, CA, and ESDD. We also manufactured slurry mixed by some kaolin and salt for the artificial contamination test and measured the degree of contaminant, AC leakage current for these contaminated samples. Consequently, the adhered contaminants to its surface is likely to be affected the performance of insulation.

  • PDF

Ultrasound Probe Contamination Classification using ATP Meter (ATP meter를 이용한 초음파 탐촉자의 오염도 분류)

  • Ha, Myeong-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.43 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, the contamination level was measured using an ATP meter using adenosine triphosphate bioluminescent material to find effective infection control to compensate for the disadvantages of the microbial culture method used for hygiene control of ultrasound probe. The convex probes were selected from six ultrasound probe in the hospital, and the samples were taken in real time before and after cleaning to check the contamination of the probe. In order to classify the pollution degree using the APT meter was classified by category. A total of 78 samples were collected from the ultrasound probe. When the pollution levels before and after cleaning were classified by category, 76.6% of the samples were classified into category 3·4 before cleaning, but they decreased to 23.3% after cleaning. 13.3% before cleaning was in category 1, but increased to 43.3% after cleaning. By classifying the pollution level, it was confirmed that the pollution level was significantly reduced by category. Until now, there was no suitable criterion for determining the contamination level by using ATP meter in medical machines where sample area is small and reused. In this study, criteria for each category were set to measure the contamination level of ATP meter suitable for small sample area such as ultrasound probe, so that contamination level could be determined in real time at the site. Therefore, it is considered that hygiene management for ultrasound probe can be more actively performed.

A Study of the Mask and Hand Contamination in Dental Clinic (치과에서의 마스크 및 손의 미생물 오염정도 비교)

  • Pyo, Eunji;Lee, Kyunghee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.85-94
    • /
    • 2019
  • Purpose: The purpose of this study was to observe the degree of mask contamination in dental hygienist for general and oral bacteria and to identify areas of mask contamination after treatment. Methods: Masks were collected with every fifty dental hygienists who currently working in the department of preventive dentistry, prosthodontics, and orthodontics in Busan. The mask bacteria were collected in specific upper and side parts of the mask. Hand germs were collected using sterile cotton swabs, and then placed in a sterile conical tube. These were transferred to the laboratory. Hand germs and mask bacteria were incubated with nutrient broth (NB) and brain heart infusion broth (BHI) for 24 hrs and each cultured with NB and BHI plate at $37^{\circ}C$ for 48 hrs. Collected data were analyzed using the SPSS Window 20. Results: The number of bacteria was observed in the order of the department of preventive dentistry ($10.1{\times}10^5CFU/ml$), prosthodontics ($14.7{\times}10^5CFU/ml$), and orthodontics ($23.3{\times}10^5CFU/ml$) in the hand. In general bacteria, the difference of contamination was seen by the parts of the mask, but there was no significant difference. However, the oral bacteria were observed highly contaminated upper part of the mask in preventive dentistry. The mask contamination according to the medical departments was observed. Especially, the contamination of mask in preventive dentistry was significantly higher than other departments in oral bacteria. Conclusion: This study suggested that correct mask replacement and recognition of contamination areas can contribute to the prevention of infectious disease. and it would be necessary to increase hand hygiene performance to prevent cross-infection with masks. Also, this study may give an idea for making guidelines for mask management and supporting to establish clear criteria for the education program of personal protective equipment.