• Title/Summary/Keyword: contaminated water

Search Result 1,325, Processing Time 0.025 seconds

What Can Radiation Protection Experts Contribute to the Issue of the Treated Water Stored in the Damaged Fukushima Daiichi Nuclear Power Plant?

  • Yamaguchi, Ichiro
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.24-31
    • /
    • 2021
  • Decommissioning efforts are underway at the reactor where the accident occurred, namely the damaged Tokyo Electric Power Company (TEPCO) Fukushima Daiichi Nuclear Power Plant (FDNPP). However, a large amount of groundwater flowing into the site has become contaminated with radioactive substances and is stored in tanks on site, which has hampered the decommissioning work. Although the inflow of groundwater has been greatly reduced through measures such as the construction of frost walls, approximately 170 ㎥ of water treated by the Advanced Liquid Processing System (ALPS) is being stored in tanks, each day. The tanks used to store this treated water are expected to become full by around the summer of 2022. It is not easy to get people to understand the efforts of all concerned parties, and providing clear information to these concerned parties is also a challenge. Questions have also been raised regarding whether other alternatives have been fully explored in the ALPS subcommittee. Some people have commented that the answers to the questions raised regarding the biological effects of tritium transmutation are inadequate. Some suspect that the answers are too detailed and incomprehensible, and that the respondents may be manipulating the public with some malicious intent. In any case, each possible plan presents both advantages and disadvantages, depending on the people who are involved. That makes it an ethical and vexing issue that can sway decisions, as perspectives change. While the environmental release plan is scientifically safe, it may represent a painful alternative. On the other hand, a more careful and imaginative approach to the idea of continued storage in tanks or other forms of storage may reveal some troublesome hidden disadvantages. Under these circumstances, experts must be prepared to answer people's questions in a comprehensive and robust manner.

Evaluation of the contamination Level of Inland Pollution Sources Flowing into Taeanhaean National Park in Summer and Fall (2017-2018) (태안해안국립공원 연안으로 유입되는 하계-추계 육상오염원의 오염도 평가(2017~2018))

  • Hwang, Da Hye;Kim, Jin Hyun;Jang, Seong Geon;Jeong, Won ok;Jeong, Byungkwan
    • Journal of Environmental Science International
    • /
    • v.31 no.6
    • /
    • pp.491-501
    • /
    • 2022
  • This study evaluated the contamination levels of inland pollution sources flowing into Taeanhaean National Park. The nutritional status of influents was assessed by analyzing water quality and trophic status index (TRIX) at 52 stations, and the contamination levels of sediments were evaluated by analyzing eutrophication cleanup index (CIET) and heavy metals at 36 stations. The results of the TRIX analysis showed that 26 of the 52 stations had influents with a TRIX value of 6-10 (poor water quality/very high trophic level), indicating atrocious water quality and high eutrophication levels. The results of the CIET analysis showed that 4 out of the 36 stations were highly contaminated with organic matter. Analysis of heavy metals showed that the copper (Cu) and zinc (Zn) levels exceeded the threshold effects level (TEL) and probable effects levels (PEL) at several stations. In addition, the arsenic (As) level exceeded the threshold effects level at one station, and the levels of the other heavy metals (Cd, Cr6+, Ni, Pb, and Hg) were lower. Most inland pollution sources have been identified as small-scale, but long-term and continuous exposure can negatively affect the marine ecosystem; therefore, it necessary to prepare inland pollution source management standards and measures suitable for the characteristics of the coastal area.

Experimental Study on the Penetration Depth and Concentration of Corrosion Inhibitor Using Press-in Method Into the Inside of Concrete (콘크리트 내부로의 압입공법을 사용한 방청제의 침투깊이 및 농도에 관한 실험적 연구)

  • Cho, Hyeong-Kyu;Yoo, Jo-Hyeong;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.160-168
    • /
    • 2009
  • After steel bar was corroded it removes concrete contaminated, it does steel bar corrosion protection, repairing method and corrosion inhibitor spreading method are difficult to secure corrosion protection performance. Accordingly, in this research before Research and Development to penetrate corrosion inhibitor to high pressure by steel bar position, it measures penetration depth through corrosion inhibitor high pressure penetration experiment and amount of nitrite by position and then it predicts penetration depth in accordance with water-cement ratio, pressure, pressure time and it computed water-cement ratio, pressure, pressure time to be more than 0.6 mol ratio of chloride ion and nitrite to have outstanding corrosion protection performance. As a result of experiment, water-cement ratio gives the biggest influence to penetration of corrosion inhibitor and also the more depth of specimen becomes deep, concentration of penetrated corrosion inhibitor does not equal and becomes low.

Potable Water Treatment Study using the Double Stage Fiber Filter for the Pre-treatment of the Reverse Osmosis Membrane (역삼투막 전처리로서의 2단 섬유상 여과기를 이용한 정수처리 연구)

  • Bae, Si-Youl;Jang, Hyung-Wook;Yun, Chang-Han
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • This study was to evaluate the performance of the Double stage Pore controllable fiber (DP) filter system as the pre-treatment of the RO membrane. The evaluation for the pre-treatment filter was performed through the indirect method, SDI (Silt Density Index) measurement of the filtrate. This study was done during Jan. 3 of 2009 to Dec. 3 of 2009 at OO Water Treatment Plant that was suppling industrial water to plants, and the raw water was contaminated lake water and it was fed to the system after clarification with coagulation. The average turbidity of the feed water and that of the filtrate was 0.79 NTU (0.28~4.01 NTU), and 0.16 NTU (0.04~0.50) respectively. And so the average turbidity removal efficiency was 77%. The filtrate flow rate and the backwash water flow rate was about 230 $m^3$/day and about 8.7 $m^3$/day respectively, and so the backwash rate was 3.8%. The data for some samples were obtained after a few days storage, and it caused the higher turbidity and SDI15 as the storage time was increased. But average SDI value of the filtrate was 3.6 (2.26~5.00) which was lower than minimum value required by the RO membrane manufacturer as the RO feed water to guarantee the life time of the RO membrane. So, the DP filter system was enough for the application as the pre-treatment of the RO membrane.

Selection of Aquatic Plants Having High Uptake Ability of Pollutants in Raw Sewage Treatment (생활오폐수에 대한 정화력이 높은 수생식물 선발)

  • Kim, Choon-Song;Ko, Jee-Yeon;Lee, Jae-Saeng;Park, Sung-Tae;Ku, Yeon-Chung;Kang, Hang-Won
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.1
    • /
    • pp.25-35
    • /
    • 2007
  • Excess runoff contaminated with N and P can impact the quality of downstream water. It has been known that aquatic plants improve the water quality through their intake of organic or inorganic nutrients. This study was conducted to select aquatic plants having high purification ability for nutrient N and P, and mineral nutrients related to EC such as K, Ca, Na, Cl, and $SO_4$ in raw sewage water in greenhouse. We assessed nutrient phytoremediation potential of alien hydrophyte and hydro-crop as well as native landscape hydrophyte to select suitable aquatic plant applied to artificial wetland and buffering site of stream-side. The amount of irrigation water during whole growing period of aquatic plane ranged from 225 L $m^{-2}$ to 444 L $m^{-2}$. Oryza sativa, Typha orientalis, Zizania latifolia, Aster subulatus, Coix lachryma-jobi var. mayuen, Paspalum disdichum var. indutum which had high biomass consumed the large amount of irrigation water over 350 L $m^{-2}$. As a result of analysis of water purification effect N and P content of shoot biomass, and media soil after experiment, Oryza sativa, Zizania latifolia, Aster subulatus, Coix lachryma-jobi var. mayuen, Paspalum distichum var. indutum showed high purification ability about eutrophication elements such as T-N and T-P. It is presented that Pistia stratiotes, Eichhornia crassipes, and Paspalum distichum var. indutum had excellent purification ability about K, Ca, Na, and Cl. Moreover, Paspalum distichum var. indutum greatly removed $SO_4$ in row sewage water.

Sampling and Analysis of Soil Pore Water for Predicting the Diffusion and Behavior of Soil Pollutant Using Soil Lysimeter (토양라이시미터를 이용한 토양오염확산.거동 예측을 위한 토양공극수 채취와 분석)

  • Ko, Il-Won;Lee, Se-Yong;Kim, Kyoung-Woong;Lee, Jin-Soo
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.551-561
    • /
    • 2007
  • This case study is about the sampling and interpretation of soil pore water in order to understand and to predict the diffusion and behavior of soil pollution. For the measurement of polycyclic aromatic hydrocarbons(PAHs) in two representative hydrocarbon-contaminated sites, the extraction system of the soil pore water was set up with respect to soil depths and the behavior of contaminants was interpreted. The soil solution extraction system consisted of peristaltic pump, and extraction and sampling compartment, and can measure simultaneously the soil water pressure. The concentration of PAHs with respect to extraction pressure and time decreased due to dilution through soil pore water. Particularly, the concentration of PAHs was more reduced under the unsaturated oxic condition than saturated anoxic condition. Therefore, the soil solution extraction with respect to soil water pressure can interpret the extent of equilibrium between porewater and soil surface.

Analysis of Off-flavor Generated from a Polyethylene Terephthalate Water Bottles and Caps by Using an Electronic Nose (MS-전자코를 사용한 페트(polyethylene terephthalate) 생수병과 뚜껑의 이취 이행 분석)

  • Han, Hyun Jung;Park, Su Won;Jung, Hyo Yeon;Kim, Jung Sun;Dong, Hyemin;Noh, Bong Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.425-430
    • /
    • 2015
  • The objective of the study was to investigate the off-flavor generated from PET water bottles and their caps by using a mass spectrometry-based electronic nose. The ion fragment data obtained from the electronic nose were used for discriminant function analysis (DFA). In the case of increased concentrations of the contamination of water, the off-flavor pattern depended on the discriminant function second score instead of the discriminant function first score. To identify the cause of off-flavor in polyethylene terephthalate (PET) bottled water, the PET bottle and its cap were analyzed by DFA. The results showed that the cap generated more volatile compounds than the bottle or mineral water did. The substances causing the off-flavor were predicted to be 2,4-di-tert-butylphenol (2,4-DTBP), nonanal, and decanal when the main peak of the mass spectrum was compared with the major ion fragments of the electronic nose. Thus, using this method, we could determine whether the PET water bottle was contaminated and whether the off-flavor resulted from contamination of the bottle cap.

A Water Surface Detection Method by Correlation Analysis of Watermark Images with Time Interval (시차가 있는 수위표 이미지의 상관분석을 통한 수면측정기법)

  • Seo, Myoung-Bae;Lee, Chan-Joo;Kim, Dong-Gu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.470-477
    • /
    • 2013
  • The aim of this study is to suggest a detection method of water surface location and its evaluation results of application for same vertical position in two successive images with time interval including both staff gauge and water surface. A specific rectangular inspection area is defined from the top of watermark and then the correlation coefficients for the inspection area of the same position of two images with short time interval is calculated. Accordingly, it is possible to identify differences between changing area and fixed area of pixel density by the water flow. The photographs taken in the laboratory were analyzed in order to validate the proposed technique. As the result of the experiment, it is identified that characteristic of correlation coefficients depends on the size of the inspection area. In the case that the inspection area is within the entire width of the watermark, water surface characteristic according to correlation coefficients is clearly noticeable. Thus, it is identified that the proposed technique can be utilized to search water surfaces. Besides, using corelation analysis of two images with time interval, it is identified that error range between 10 and 42cm was reduced in the level of 2.6cm or less in the contaminated photo of existing image stage gauge. Therefore, it is expected that the suggested method can be utilized to enhance image stage gauge performance improving the previous water surface detection method.

A Sanitary Survey on the Medicinal Water Springs Located near Taegu City(1986) (대구시 인근에 산재한 약수에 대한 위생학적 조사(1986))

  • Cha, Sang-Duk;Chang, Bong-Ki;Chun, Byung-Yeol;Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.19 no.2 s.20
    • /
    • pp.273-280
    • /
    • 1986
  • 'Medicinal water' have been used for the treatment of disease and the promotion of health. To study the quality and health effect of 'medicinal water', the eleven springs located near Taegu City during the period of March 27-February 17, 1986 were tested for biological and physiochemical examination and were checked for sanitary environment around the spring. Among them three springs (27.3%) had a good sanitary equipments and only one was negative for biological examination. Three 'medicinal warer' were accepted as potable by physicochemical examination. According to above findings, all of the 'medicinal water' sampled from the springs located near Taegu City were not potable by this sanitary survey adopted Drinking Water Standard in Korea. Kachang and Youngchum 'medicinal water' were more contaminated by heavy metals and bacteria than those of other springs. To solve the problem of contamination by heavy metals that originated from uncertain sources, we should search for the sources of water contamination, remove it completely and also support the environmental equipments and management system in protection of safe 'medicinal water' supply.

  • PDF

Antibacterial and Rinsing Activities Against Potentially Harmful Bacteria in Rice during Rice Flour Production (쌀가루 제분용 백미 내 잠재적 위해 세균에 대한 살균 및 세척 효과)

  • Han, Jae-Kwang;Cha, Min-Hee;Kim, Min-Ju;Kim, Keun-Sung
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.117-122
    • /
    • 2014
  • Rice can be the contaminating with soil-borne bacteria. Furthermore, the contaminated bacteria can be grown during immersion process for produce wet-milled rice flour. Therefore, disinfectants can be added during the immersion process. Antibacterial activities of the natural disinfectant, fermented rice spent water (FRSW), and the chemical disinfectants, chlorine dioxide (CD) and sodium benzoate (SB), were respectively determined when added in pure cultures of target bacteria such as Salmonella typhimurium, Escherichia coli, and Bacillus cereus or when added to immersion water in the immersion process. In addition, rinsing effects for removing bacteria were determined when rice was rinsed with water before and after the immersion process. Antibacterial activities were rapidly increased as increasing amounts of the disinfectants are added to the pure cultures of the target bacteria. Antibacterial activity of CD was the most effective among the three tested disinfectants when added to the pure cultures of the target bacteria, respectively. Those of the same disinfectants were increased when they were increasingly added to the immersion water. However those of the disinfectants were less effective when added to the immersion water. On the other hand, rinsing effects for removing bacteria were the most effective when rice was rinsed only with water without the immersion process. Collectively, rinsing rice with water only was more effective than using disinfectants in the immersion water during rice flour production.