• Title/Summary/Keyword: contaminated water

Search Result 1,325, Processing Time 0.032 seconds

Development of Molecular Diagnostic System with High Sensitivity for the Detection of Human Sapovirus from Water Environments

  • Lee, Siwon;Bae, Kyung Seon;Lee, Jin-Young;Joo, Youn-Lee;Kim, Ji-Hae;You, Kyung-A
    • Biomedical Science Letters
    • /
    • v.27 no.1
    • /
    • pp.35-43
    • /
    • 2021
  • Human Sapovirus (HuSaV) is one of the major causes of acute gastroenteritis in humans, and it is used as a molecular diagnostic technique based on polymerase chain reaction (PCR) from humans, food, shellfish, and aquatic environments. In this study, the HuSaV diagnosis technique was used in an aquatic environment where a number of PCR inhibitors are included and pathogens, such as viruses, are estimated to exist at low concentration levels. HuSaV-specific primers are improved to detect 38 strains registered in the National Center for Biotechnology Information (NCBI). The established optimal condition and the composition, including the RT-nested PCR primers and SL® Non-specific reaction inhibitor, were found to have 100 times higher sensitivity based on HuSaV plasmid than the previously reported methods (100 ag based on HuSaV plasmid 1 ng/μL). Through an artificial infection test, the developed method was able to detect at least 1 fg/μL of HuSaV plasmid contaminated with total nucleic acid extracted from groundwater. In addition, RT-nested PCR primer sets for HuSaV detection can react, and a positive control is developed to verify false positives. This study is expected to be used as a HuSaV monitoring method in the future and applied to the safety response to HuSaV from water environments.

Antibacterial Effect of Fermented Rice Water against Food-borne Bacteria in Kitchen Towel (행주 내 식품위해미생물에 대한 쌀뜨물 발효액의 살균 효과)

  • Ha, Ji-Hyoung;Lee, Yu-Si;Lee, Seok-Joo;Hwang, Sun-Soon;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.365-369
    • /
    • 2007
  • This study was conducted to seek optimum concentration and treatment time of fermented rice water (Rizen) to disinfect food-borne bacteria in kitchen towel. $2.65\;log_{10}cfu/g$ of E. coli was reduced when double or triple diluted fermented rice water was treated during 2 hours. In case of concentrated fermented rice water, crude and double diluted solutions showed complete sterilization after 2 and 5 hours, respectively. On the other hand, triple, quadruple, quintuple diluted solutions needed 24 hours for complete sterilization. The effect of fermented rice water as a disinfectant was compared with water, detergent and chlorine treatment against E. coli and S. Typhimurium contaminated in kitchen towel. The initial number of E. coli in untreated kitchen towel were $5.0\;log_{10}cfu/g$ and were decreased to 4.32, 3.70 and 3.02 by treatments of water, detergent and chlorine, respectively. The double and triple diluted fermented rice water and double diluted concentrated fermented rice water also reduced the E. coli in kitchen towel to 2.43, 2.30 and $1.88\;log_{10}cfu/g$, respectively. The initial number of S. Typhimurium in untreated kitchen towel were $4.80\;log_{10}cfu/g$ and were decreased to 4.12, 3.58 and 2.81 by treatments of water, detergent and chlorine, respectively. The double and triple diluted fermented rice water and double diluted concentrated fermented rice water also reduced the E. coli in kitchen towel to 2.14, 2.03 and $1.59\;log_{10}cfu/g$, respectively. Consequently, the fermented rice water is thought to be a good disinfectant to reduce food-borne bacteria like E. coli and Salmonella contaminated in kitchen towel.

A Study on the Impact of Landfill Leachate on the Water Environment - A case study of Nanji landfill - (매립지 침출수가 수환경에 미치는 영향에 관한 연구 - 난지도 매립지 사례를 중심으로-)

  • Park, Seok Soon;Park, Jae Woo;Jeong, Mi Hoon;Lee, Ji Mi;Cho, Kyung Sook;Yi, Seung Mook
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.2
    • /
    • pp.9-20
    • /
    • 1999
  • Until 1993, Nanji landfill has been the main solid waste treatment facility for Seoul, which is the capital of Korea. Since the landfill has not been properly lined, soil and ground water around the landfill has been contaminated. Due to the proximity, it has been speculated that the water quality of the Han River would have been also influenced by the leachate. In order to illuminate this, HELP model to estimate the quantity of the leachate from Nanji landfill and RMA model to simulate the change of water quality in Han River were applied in this research. The result indicates that the quantity of leachate from Nanji landfill has been overestimated by previous works and it was due to the failure to consider the water storage capacity of the landfill. The effect from Nanji landfill leachate on the water quality, in terms of COD input, proves to be smaller than those from other tributaries and influents to the River and the effect is larger when the flow of the River is reversed due to the tide.

  • PDF

Risk Assessment for Heavy Metals in Soil, Ground Water, Rice Grain nearby Abandoned Mine Areas (국내 폐금속 광산지역에서의 토양, 지하수, 쌀의 중금속 노출에 따른 인체 위해성평가)

  • Na, Eun-Shik;Lee, Yong-Jae;Ko, Kwang-Yong;Chung, Doug-Young;Lee, Kyu-Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.4
    • /
    • pp.245-251
    • /
    • 2013
  • BACKGROUND: The objectives of this study are to investigate the contamination levels of heavy metals in soil, ground water, and agricultural product near the abandoned Boeun and Sanggok mine areas in Korea and to assess the health risk for these local residents exposed to the toxic heavy metals based on analytical data. METHODS AND RESULTS: By the results of human health risk assessment for local residents around Boeun and Sanggok, human exposure to cadmium, copper, arsenic from soil and to lead, cadmium, and arsenic from rice grain were higher in Sanggok, but human exposure to zinc and arsenic from ground water was higher in Boeun. By the results of hazard index (HI) evaluation for arsenic, cadmium, copper, lead, and zinc, HI values in both areas were higher than 1.0. This result indicated that the toxicity hazard through the continuous exposure to lead, cadmium, arsenic from rice, ground water, and soil would be likely to occur to the residents in the areas. Cancer risk assessment for arsenic, risks from the rice were exposed to one to two out of 10,000 people in Boeun and one of 1,000 people in Sanggok. These results showed that the cancer risks of arsenic in both areas were 10~100 times greater than the acceptable cancer risk range of US EPA ($1{\times}10^{-6}{\sim}1{\times}10^{-5}$). CONCLUSION(S): Therefore, if these two local residents consume continuously with arsenic contaminated soil, ground water, and rice, the adverse health effects (carcinogenic potential) would be more increased.

Effect of Water Contamination of the Lubricant and Surface Roughness of Bearing Steel on the Rolling Contact Fatigue Life (윤활유의 수분혼입 및 베어링강의 표면 조도가 구름접촉 피로수명에 미치는 효과)

  • Heo, Tae Hyeon;Sim, Chung-Ki;Kim, Hong Seok;Shin, Ki-Hoon;Cheong, Seong Kyun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.15-20
    • /
    • 2017
  • A large amount of research has been performed on the rolling contact fatigue(RCF) life of bearings, since it directly affects the safety and reliability of mechanical systems. It is well known that rolling contact fatigue life is influenced by several parameters including contact pressure, oil contamination by water or metal particles, and the surface conditions of bearings. However, the detailed damage mechanisms involved in rolling contact fatigue have not been clearly identified yet. In this paper the effects of water contamination of the lubricant and surface roughness of bearing steel on the rolling contact fatigue life were investigated. Two types of specimens with different surface roughness values were prepared through turning and lapping operations. They were tested under two different lubrication conditions, i.e. oil lubricant with 100% of oil and the water contaminated condition with 80% of oil and 20% of water using the rolling contact fatigue testing machine. The surface damage induced by the rolling contact fatigue was observed by using atomic force microscope(AFM). Experimental results show that the rolling contact fatigue life, $L_{10}$ was reduced by 24 to 33% depending on the lubrication condition. The reduction of fatigue life in the range of 53 to 57% was also observed at different surface roughness conditions.

Characteristics of Suspended Fine-Grained Particles in Settling Columns (침강수주에서 부유된 광물성 미립자의 특성)

  • Kim Jong-Woo;Yoon Sei-Eui;Lee Jong-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.393-398
    • /
    • 2005
  • Suspended fine mineral particles are deposited at the areas with low flow velocity and low transportation capacity in rivers, reservoirs and lakes. It can be contaminated by heavy metals. Examples of problem fields art dredging of sediment, water pollutants, and maintenance of navigation channels and construction works. To deal with the settling problems it is necessary to understand tile physico-chemical characteristics of cohesive sediment under varying density of particle and ion addition(NaOH, HCl, NaCl), which is dissolved in river, because fine-grained cohesive sediment can lead to flocculation with the physico-chemical influences and takes different characteristics. Experiments with fresh and saline water are followed with fine-grained sediments(alumina and quartz) in settling columns. Settling velocity of suspended fine particles in still water was measured with a pressure sensor(maximum 10 mbar). Until the initial concentration of 20,000 mg/1 of alumina and quartz the settling velocity was on the increase. Above this initial concentration was it on the decrease. In an acid condition, which causes strong flocculation, average settling velocity of quartz powder was high. In an alkaline water low average settling velocity of it was observed. However, alumina behaved exactly contrarily.

  • PDF

Analysis of Field Experimental Data for Water Quality Improvement of Tributary Stream to Estuarine Reservoir Using Constructed Wetland System (인공습지를 이용한 하구담수호 유입하천수 수질개선 현장실험결과 분석)

  • Ham, Jong-Hwa;Yoon, Chun-G.;Koo, Won-Seok;Kim, Hyung-Chul;Shin, Hyun-Bhum
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.5
    • /
    • pp.141-153
    • /
    • 2004
  • Wetland system is widely accepted as one of natural water purification systems around the world for nonpoint sources pollution control. Constructed wetlands have become a popular technology for treating contaminated surface and waste water. In this study, the field experiment to reduce nonpoint source pollution loadings from polluted stream waters using wetland system was performed from June 2002 to March 2004. Four wetlands were used and the size of each one was 0.8ha. Water of Dangjin stream flowing into Seokmun estuarine reservoir was pumped into wetlands. Inflow and hydraulic residence time of the system was 500 $m^3$/day∼1,500 $m^3$/day, 2∼5 days, respectively. After 2 year operation, plant-coverage of the wetlauds was about 70% from bare soil surface at initial stage . Average water quality of the influent was $BOD_5$ 4.17 mg/L, TSS 18.45 mg/L, T-N 4.32 mg/L, and T-P 0.30 mg/L. The average removal rate of $BOD_5$, TSS, T-N and T-P during the study period was 5.6%, 46.6%, 45.7%, and 54.8%, respectively. Organic ($BOD_5$) removal rate was low and the reason might be low influent concentration. Wetland removal rate of T-P was about 10% higher than T-N. Performance of the experimental system was compared with existing data base (NADB), and it was within the range of general system performance. Overall, the wetland system was found to be adequate for treating polluted water stream with stable removal efficiency even during the winter period. Most of the nonpoint source pollutions from watershed are transported by streams or ditches, and they could be controled by constructed wetland system before entering the lake or reservoir.

Study on the Heavy Metal Contents in Fishes and Shellfishes of Gyeongsangnam-Do Coastal Area-Part 1 (경상남도 연안지역 어패류 중의 중금속 함량에 관한 연구-제1보)

  • Ha, Gang-Ja;Song, Ju-Yeong
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.3
    • /
    • pp.132-139
    • /
    • 2004
  • As measure against the environmental pollution, maximum efforts to improve of the environmental pollution have also been made; removal of the contaminated sediments of the bay and the coastal area, monitoring of several heavy metal levels in fishes, shell fishes, sea water and sediment, and so on. The objective of this research is to investigate how much metals are included in the sea water, sediment, fishes and shell fishes in kyeongnam coastal area. Specifically, we are investigating the relationships between the metal included in fishes and sea water, and shell fishes and sediment, and heavy metals and heavy metals respectively. Heavy metal over the studied component and area, the average concentrations of Pb, Cd, Cr and Hg in sea water were 0.0029 mg/L, 0.005 mg/L, 0.0016 mg/L and ND, those of sediment were 11.9583 mg/kg, 0.2136 mg/kg, 1.9158 mg/kg and Hg 0.0108 mg/kg, those of fishes were 0.4358 mg/kg. 0.0726 mg/kg, 1.1188 mg/kg and Hg 0.0622 mg/kg, and those of shellfishes were Pb 0.6738 mg/kg, Cd 0.2223 mg/kg, Cr 0.5516 mg/kg and Hg 0.0117 mg/kg respectively. In the relationship test, Cd was significant in the relationship between fishes and sea water, and Hg was significant in the relationship between sediment and shellfishes.

Study on The Salinization in Groundwater of the Eastern Area of Cheju Island (제주도 동부지역 지하수의 염수화에 관한 연구)

  • 김지영;오윤근;류성필
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.47-58
    • /
    • 2001
  • According to the results of the groundwater quality investigation about 230 holes all over the country, the groundwater which was in excess of standard grows larger every year and closed holes increased to 23,457 holes in 1997 from 15,724 holes in 1996. This is the major reasons that water quality contamination, shortage of water quantity, increasing of salinity and so on. There are 7 groundwater salinization sources which are condisered as most important on a regional level. And among theses the Cheju Island groundwater salinization sources are (1) halite solution, (2) natural saline groundwater, (3) sea-water intrusion. The method of taking an isotopes is one of research methods of the origin of groundwater salinization and is used in so many studies because it has very high confidence. $^{18O}O, ^2H, ^3H, ^{14}C$ and so on in an isotopes are frequently used in the method of them. Consequently on this study we analyzed major ions and $^3H$ in groundwater, sea-water and rain of the eastern part of cheju island known as contaminated site from long time ago to examine the origin of groundwater salinization. Relation ratios of the major ions versus chloride ion shows similar tendency to sea-water. This indicates that sea-water entered the groundwater layer. And amount of $^3H$ in holes of the land side is higher than of the sea side. Relation of chloride ion versus $^3$H indicates negative character. Therefore we can think that the reason of groundwater salinization of this part is natural saline groundwater and halite solution by relation.

  • PDF

Parameters Affecting Indoor Air Exposure to Volatile Organic Compounds (휘발성 유기화합물에 대한 실내공기노출에 영향을 미치는 인자)

  • ;C.P. Weisel
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.47-51
    • /
    • 1992
  • Volatile organic rompounds(VOCs) present in the VOCs-contaminated water are released to air while showering and their air concentrations depend on the shower parameters, resulting in the variation of the VOCs breath concentration. The present study evaluated the key shower parameters(water temperature and inhalation duration) that affect the inhalation exposure to air chloroform while showering, by determining chloroform breath concentration. The chloroform breath concentrations increased with water temperature and inhalation duration increase. The two inhalation exposure conditions which resulted in the greatest chloroform breath contentration difference were a 5 min-inhalation exposure with warm water and a 15 min-inhalation exposure with hot water. The chloroform breath concentration was almost three times higher after later exposure. The mathematical model analyzing the relationship between two key shower parameters and breath concentration normalized to water concentration fits quite Ivell with the experimental data at a probability of p : 0.0001.

  • PDF