• Title/Summary/Keyword: contaminated water

Search Result 1,322, Processing Time 0.035 seconds

A Study on the Characteristics of Water Pollution in Rural Areas (농촌유역(農村流域)에서의 수질오염(水質汚染) 특성(特性)에 관한 연구(硏究))

  • Kim, Han-Tea;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.12 no.2
    • /
    • pp.129-143
    • /
    • 1993
  • The objective of this study is to understand the status of the water pollution in rural areas and to furnish a basic material for the management of the water pollution in rural areas. For this purpose, the Bokha river basin, Ichon-Gun, Kyungki-Do considering as a typical agricultural area was selected as a representative experimental watershed. The characteristics of water pollution in streams of the Bokha river basin was revealed by investigating and analyzing data collected for the source of pollution, water qualities in reaches of the stream, the degree of contribution to the river contamination by pollution mass produced from each source, and the status of the self-purification at the main stream. The most important source of the water pollution in investigated watershed was livestock, and the next important one were in the order of population, land use, and industry. The water quality of the Bokha river was relatively favorable judging from the BOD and COD concentration, however since the concentration of T-N and T-P showed significantly large values, it was concluded that the river was seriously contaminated by the nutrient material. The main cause of the river contamination was proved due to livestock waste. For the T-N, both land use and livestock were much more contributied to the pollution than any other source, which characterized the typical water pollution of rural areas. Run-off ratios for the Bokha river tributaries to the main stream were changed according to the similar trend to the variation of discharges in the branch streams. For the value of the self-purification constant at the main stream, it showed smaller value in the downstream reach than the middle-stream and upstream reaches, where could possibly have smaller reoxidation action due to slower velocity and deeper water depth.

  • PDF

Water Quality Variations due to Tidal Change in the Lower Part of the Nagdong River (조석에 따른 낙동강 하류수질의 변화)

  • KIM Yong-Gwan;CHANG Dong-Suck;MOON Hong-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.2
    • /
    • pp.109-118
    • /
    • 1985
  • This experiment was carried out to evaluate the water quality in the lower part of the Nagdong river in Korea. Three hundred and sixty water samples were collected from the 15 stations from December 1981 to November 1982 by tide(see Fig.1). Water temperature, pH, chloride ion, salinity, total coliform, fecal coliform, viable cell count and the composition of coliform were observed to evaluate the water quality. The variations of water temperature was ranged from $2.0^{\circ}C\;to\;29.5^{\circ}C$ and as mean value from $15.8^{\circ}C\;to\;18.9^{\circ}C$. The range of pH was 6.00-8.88 and 7.20-7.96 as mean value. The concentration of chloride ion from St. 1 to 5 was higher as 17.51-771 mg/l in flood tide than 13.12-264.58 mg/l in ebb tide. Specially, water quality at St.1 (Samrangjin) which located about 46 km far from Hadan was also influenced by tide. Salinities of water in flood tide were a litte higher ($11.05{\sim}31.08\%0$) than those of in ebb tide ($7.80{\sim}29.28\%0$). Total coliform MPN's ranged from 3.6/100 m/l to 460,000/100ml. The geometric mean value of the upper area (included St. $1{\sim}3$) was $259{\sim}538/100ml$, that of the middle area (included St. $4{\sim}6$) was $1,097{\sim}39,544/100ml$ for it leveled heavy contamination. Specially, in the ebb tide St. 10 was influenced by St. 6 and 7. In the upper area, the geometric mean value of fecal coliform MPN's was $109{\sim}199/100ml$ but in the area in cluded St. 5, 6 and 7 were heavily contaminated by domestic sewage, waste water from the factories area and bird's excrement. Composition of coliform was $17\%$ Escherichia coli group, $33\%$ Citrobacter freundii group, $28\%$ Enterobacter aerogenes group and $21\%$ others. Plate count of samples was varied from <30 to $3.9{\times}10^4/ml$ during the study period.

  • PDF

A Study on groundwater and pollutant recharge in urban area: use of hydrochemical data

  • Lee, Ju-Hee;Kwon, Jang-Soon;Yun, Seong-Taek;Chae, Gi-Tak;Park, Seong-Sook
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.119-120
    • /
    • 2004
  • Urban groundwater has a unique hydrologic system because of the complex surface and subsurface infrastructures such as deep foundation of many high buildings, subway systems, and sewers and public water supply systems. It generally has been considered that increased surface impermeability reduces the amount of groundwater recharge. On the other hand, leaks from sewers and public water supply systems may generate the large amounts of recharges. All of these urban facilities also may change the groundwater quality by the recharge of a myriad of contaminants. This study was performed to determine the factors controlling the recharge of deep groundwater in an urban area, based on the hydrogeochemical characteristics. The term ‘contamination’ in this study means any kind of inflow of shallow groundwater regardless of clean or contaminated. For this study, urban groundwater samples were collected from a total of 310 preexisting wells with the depth over 100 m. Random sampling method was used to select the wells for this study. Major cations together with Si, Al, Fe, Pb, Hg and Mn were analyzed by ICP-AES, and Cl, N $O_3$, N $H_4$, F, Br, S $O_4$and P $O_4$ were analyzed by IC. There are two groups of groundwater, based on hydrochemical characteristics. The first group is distributed broadly from Ca-HC $O_3$ type to Ca-C1+N $O_3$ type; the other group is the Na+K-HC $O_3$ type. The latter group is considered to represent the baseline quality of deep groundwater in the study area. Using the major ions data for the Na+K-HC $O_3$ type water, we evaluated the extent of groundwater contamination, assuming that if subtract the baseline composition from acquired data for a specific water, the remaining concentrations may indicate the degree of contamination. The remainder of each solute for each sample was simply averaged. The results showed that both Ca and HC $O_3$ represent the typical solutes which are quite enriched in urban groundwater. In particular, the P$CO_2$ values calculated using PHREEQC (version 2.8) showed a correlation with the concentrations of maior inorganic components (Na, Mg, Ca, N $O_3$, S $O_4$, etc.). The p$CO_2$ values for the first group waters widely ranged between about 10$^{-3.0}$ atm to 10$^{-1.0}$ atm and differed from those of the background water samples belonging to the Na+K-HC $O_3$ type (<10$^{-3.5}$ atm). Considering that the p$CO_2$ of soil water (near 10$^{-1.5}$ atm), this indicates that inflow of shallow water is very significant in deep groundwaters in the study area. Furthermore, the P$CO_2$ values can be used as an effective parameter to estimate the relative recharge of shallow water and thus the contamination susceptibility. The results of our present study suggest that down to considerable depth, urban groundwater in crystalline aquifer may be considerably affected by the recharge of shallow water (and pollutants) from an adjacent area. We also suggest that for such evaluation, careful examination of systematically collected hydrochemical data is requisite as an effective tool, in addition to hydrologic and hydrogeologic interpretation.ion.ion.

  • PDF

Chemical and Bacteriological Water Qualify of the Sonakdong River (서낙동강 강수의 화학적${\cdot}$세균학적 수질)

  • KIM Yong Gwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.4
    • /
    • pp.347-355
    • /
    • 1986
  • The Sonakdong river is very important water source not only for agricultural water of Kimhae field but also for fishery water. Recently the middle and lower areas of the river have the tendency to be heavily contaminated by domestic sewage and agricultural chemicals. Fifty six water samples were collected from 8 stations from July to December in 1985 for the experiment (Fig. 1). To evaluate the water quality, pH, water temperature, electrical conductivity, chloride ion, nutrients ($NO^{-}_{2}-N,\;NO^{-}_{3}-N,\;NH^{+}_{4}-N,\;PO^{3-}_{4}-P,\;SiO_2-Si$), total coliform, fecal coliform, and fecal streptococcus were determined. Range and mean value of the samples were as follows; pH $6.3{\sim}9.4$, 7.91; water temperature $6.1{\sim}34.8^{\circ}C,\;23.88^{\circ}C$; electrical conductivity (from St. A to G) $1.575{\times}10^2{\sim}30.50{\times}10^2{\mu}{\mho}/cm,\;6.57{\times}10^2{\mu}{\mho}/cm$; chloride ion $23.5{\sim}14,300mg/l$, 770.0mg/l; nitrite-nitrogen $0.007{\sim}0.110mg/l$, 0.053mg/l; nitrate-nitrogen $0.001{\sim}1.638mg/l$, 0.649 mg/l; ammonia-nitrogen $0.017{\sim}4.200mg/l$, 0.497mg/l; phosphate-phoshorus $0.011{\sim}0.281mg/l$, 0.086mg/l; and silicate-silicious $2.4{\sim}6.5mg/l$, 4.43mg/l. Electrical conductivity and chloride ion of the station F(Chomanpo) were $2.676{\times}10^2{\mu}{\Omega}cm$ and 123.99mg/l which were lower than those of others. Among the analyzed nutrients, silicate-silicious concentration was the highest through all the samples. The bacterial density of the samples ranged $36{\sim}110,000/100ml$ for total coliform, $15{\sim}46,000/100ml$ for fecal coliform and $3.6{\sim}15,000/100ml$ for fecal streptococcus. The range and the mean of the TC/FC ratio were $3.0{\sim}9.6$, 5.51 and those of the FC/FS ratio were $1.1{\sim}9.2$, 6.19, respectively. On the other hand, fecal coliform was not detected in about $78\%$ of the water samples examined. Composition of coliform was $52\%$ Escherichia coli group, $3\%$ Citrobacter freundii group, $13\%$ Enterobacter aerogenes group and $31\%$ others.

  • PDF

INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL (치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향)

  • Lee, Jung-Tae;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.166-179
    • /
    • 1999
  • Apical sealing is essential for the success of surgical endodontic treatment. Root-end cavity is apt to be contaminated with moisture or blood, and is not always easy to be dried completely. The purpose of this study was to evaluate the influence of dry methods of retrocavity on the apical seal in endodontic surgery. Apical seal was investigated through the evaluation of apical leakage and adaptation of filling material over the cavity wall. To investigate the influence of various dry methods on the apical leakage, 125 palatal roots of extracted human maxillary molar teeth were used. The clinical crown of each tooth was removed at 10 mm from the root apex using a slow-speed diamond saw and water spray. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. After removing of the coronal 2 mm of filling material, the access cavities were closed with Cavit$^{(R)}$. Two coats of nail polish were applied to the external surface of each root. Apical three millimeters of each root was resected perpendicular to the long axis of the root with a diamond saw. Class I retrograde cavities were prepared with ultrasonic instruments. Retrocavities were washed with physiologic saline solution and dried with various methods or contaminated with human blood. Retrocavities were filled either with IRM, Super EBA or composite resin. All the specimens were immersed in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using one-way ANOVA and Duncan's Multiple Range Test. To evaluate the influence of various dry methods on the adaptation of filling material over the cavity wall, 12 palatal roots of extracted human maxillary molar teeth were used. After all the roots were prepared and filled, and retrograde cavities were made and filled as above, roots were sectioned longitudinally. Filling-dentin interface of cut surfaces were examined by scanning electron microscope. The results were as follows: 1. Cavities dried with paper point or compressed air showed less leakage than those dried with cotton pellet in Super EBA filled cavity (p<0.05). However, there was no difference between paper point- and compressed air-dried cavities. 2. When cavities were dried with compressed air, dentin-bonded composite resin-filled cavities showed less apical leakage than IRM- or Super EBA-filled ones (p<0.05). 3. Regardless of the filling material, cavities contaminated with human blood showed significantly more apical leakage than those dried with compressed air after saline irrigation (p<0.05). 4. Outer half of the cavity showed larger dentin-filling interface gap than inner half did when cavities were filled with IRM or Super EBA. 5. In all the filling material groups, cavities contaminated with blood or dried with cotton pellets only showed larger defects at the base of the cavity than ones dried with paper points or compressed air.

  • PDF

Availability of Heavy Metals in Soil and Their Translocation to Water Dropwort (Oenanthe javanica DC.) Cultivated near Industrial Complex (토양내 중금속 유효도와 미나리중의 흡수이행성 평가)

  • Jung, Goo-Bok;Kim, Won-Il;Lee, Jong-Sik;Shin, Joung-Du;Kim, Jin-Ho;Lee, Jeong-Taek
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.4
    • /
    • pp.323-330
    • /
    • 2006
  • This experiment was conducted to investigate heavy metal transition and bioavailability from soil to the edible pare of water dropwort near industrial complex. The soils were collected from the paddies cultivating water dropwort stream sediments, and background soils near industrial complex. The pH values, organic matter, Av. $P_2O_5$, Ex. Ca content of paddy soils were higher than those measured for nor-contaminated paddy fields in 2003. The contents of Cd and Cu was higher than those of standard level for soil contamination by Soil Environmental Conservation Act in Korea. The pollution index in stream sediments were higher than those of paddies cultivating water dropwort. The geoaccumulation index of heavy metals in paddy soils and stream sediment were in the order Cu>Cd>Ni>Zn>Pb. The rates of 0.1N-HCl extractable heavy metals to total contents in soils were in the order Cd>Cu>Zn>Ni>Pb. In case of Cd and Ni in paddy soils near industrial complex, 0.1N-HCl extractable heavy metals and total content were highly correlated with each other. Heavy metal contents in mot parts were higher than those in top pare of water dropwort. The Zn and Cu transfer factor from soil to the top pare of water dropwort were higher than those of other heavy metals. The bioavailability of water dropwort varied considerably between the different parts and heavy metals. Cd, Cu and Ni contents in water dropwort were correlated with each elements in paddy soils.

Evaluation of Cleanness and Physical Properties of W/O Microemulsion (W/O Microemulsion 세정제의 물성 및 세정성 평가)

  • Lee, Myung Jin;Han, Ji Won;Lee, Ho Yeol;Han, Sang Won;Bae, Jae Heum;Park, Byeong Deog
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.769-777
    • /
    • 2002
  • Using four components - nonionic surfactants, water, hydrocarbon oil and an alcohol as cosurfactant, 12 types of cleaning agents were prepared, and their physical properties such as surface tension, viscosity, electroconductivity and phase stability were measured. As the formulated cleaning agents have low surface tensions(30.5-31.1 dyne/cm) and low viscosities (1.6-7.2 c.p.), they are satisfied with the general physical properties of water-in-oil(W/O) microemulsions for their industrial use. They showed a tendency that their temperature range for stable one-phase microemulsion decreased in accordance with the increase of alcohol/surfactant(A/S) ratio in the formulations. However, the temperature range of one-phase microemulsion was much more affected by hydrophilic lipophillic balance(HLB) value of the nonionic surfactant which increased its temperature range and it increased in accordance with the higher HLB value in the formulations. And the maximum content of water which can keep stable one-phase W/O microemulsion was measured at each sample. In addition, their temperature range for stable one-phase microemulsion was also measured. It was confirmed that the selection of surfactant type was very important for formulating a cleaning agent, since the W/O microemulsion system with the nonionic surfactant of the lower HLB value showed better cleaning efficacy that of the higher HLB value for abietic acid as a soil, which was used for preparing a rosin-type flux. In the formulated cleaning agents with the increase of A/S ratio in the formulations, however, there was no significant difference in cleaning efficacy. It was investigated that the differences of their cleaning efficacy was affected by the change of the condition of temperature and sonicating frequency as important factors in the industrial cleaning. That is, the higher, their cleaning temperature and the lower, their sonicating frequency, the more increased, their cleaning efficacy. Furthermore, using optical instruments like UV/Visable Spectrophotometer and FT-IR Spectrometer, their cleaning efficacy for abietic acid was measured. The removal of soil from the contaminated rinse water was measured by gravity separation method in the rinse bath. As a result, the cleaning agent system having the nonionic surfactant of HLB value 6.4 showed over 85% water-oil separation efficacy at over $25^{\circ}C$. Therefore, it was demonstrated in this work that the formulating cleaning agents were very effective for cleaning and economical in the possible introduction of water recycling system.

The effect of cleaning methods on bond strength of zirconia after saliva contamination (타액으로 오염된 지르코니아 수복물의 접착강도에 세척 방법들이 미치는 영향)

  • Shim, Young-Bo;Choi, An-Na;Son, Sung-Ae;Jung, Kyoung-Hwa;Kwon, Yong Hoon;Park, Jeong-Kil
    • Korean Journal of Dental Materials
    • /
    • v.44 no.1
    • /
    • pp.61-68
    • /
    • 2017
  • This study evaluated the effects of various cleaning methods on the shear bond strength of zirconia ceramics after saliva contamination. Eighty zirconia disk specimens were divided into 8 groups. All groups were treated with one coat of MDP primer. All specimens (except the negative control) were contaminated with human saliva on the zirconia surface. The positive control went through the bonding procedure immediately after contamination without any cleaning procedure. With the exception of control groups, the remaining six groups were rinsed with water and either applied with MDP recoating (WATER+MDP) or without MDP recoating (WATER). While some were cleaned with a Ivoclean with MDP recoating (IVOCLEAN+MDP) or not applied with MDP recoating(IVOCLEAN), others were cleaned with a 1% NaOCl solution with MDP recoating (NaOCl+MDP) or without MDP recoating (NaOCl). The shear bond strength of all specimens were measured after being stored in distilled water at $37^{\circ}C$ for 24 hours. The data was analyzed statistically by an analysis of ANOVA, Tukey's post hoc test and Student's t-test was used to compare the shear bond strength according to the re-coating of MDP after the cleaning procedure. The positive control group showed the lowest shear bond strength value, and the WATER group and NaOCl group showed no significant difference when compared to the positive control group. The IVOCLEAN group showed significantly higher shear bond strength when compared to Water group and NaOCl group but not with the group of negative control. After rinsing with water or the NaOCl solution, the comparison of the single coating of MDP and re-coating of MDP showed different shear bond strengths but there was no significant difference to the negative control. After rinsing with Ivoclean, there was no significant difference to the negative control regardless of the recoating of MDP. In conclusion, the shear bond strength was affected by the cleansing procedure and Ivoclean was found to be effective regardless of the re-coating of MDP. When water or the NaOCl solution is used to remove surface contaminants, the re-coating of MDP provides a positive effect on cementation.

Analysis on Consolidation Behavior of Soft Ground with Reactive Drain Pile (반응성 배수파일이 타설된 지반의 압밀거동 분석)

  • Kim, Beomjun;Oh, Myounghak;Yune, Chanyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.1
    • /
    • pp.13-23
    • /
    • 2014
  • Geotechnical evaluation on the reactive drain pile which can achieve simultaneously both the soft ground improvement and the remediation of contaminated pore water in reclamation site was performed. Applicability of steel-making slag used as a inside reactive material was confirmed. To investigate the consolidation characteristics of the soft ground improved by reactive drain pile, testing devices to form and install the reactive drain pile were developed and laboratory tests were performed according to the existence of outside sand drain and the length of impermeable barrier. Test results showed that the consolidation time was decreased as the shortening of impermeable barrier. However, the effect of outside sand drain on consolidation time was dominant compared with the length of impermeable barrier.

Synthesis and Evaluation of New Nonflammable Cleaning Agents (난연성 세정제의 합성 및 평가에 관한 연구)

  • Kim, Ah Na;Yu, Young;Kim, Seok Chan
    • Clean Technology
    • /
    • v.19 no.2
    • /
    • pp.184-188
    • /
    • 2013
  • To increase flash point which is related to flammability, seven unprecedented new cleaning agents containing fluoride atoms have been invented. These newly synthesized cleaning agents's physical properties which were conducted by Korea Institute of Petroleum Management by using a standard method showed excellent values. Particularly, flash point of newly synthetic cleaning agents is more higher than that of fluoride free compound. A specimen for cleaning ability was prepared by cutting in $60mm{\times}40mm$ size of stainless steel plate. The surface of the above specimens was applied with four kinds of contaminants, such as paraffin based drawing oil, flux abietic acid, water-insoluble cutting oil, and lubricating oil. Contaminated specimens were immersed in new compounds (1-7) for 1 to 5 minutes to dissolve oil in the cleaning agent. Although the data indicate that all compounds (1-7) exhibit lower cleaning ability toward cutting oil, it is observed that in the case of the present study more than 80% of pollutants on the surface were almost removed within 5 minutes.