• Title/Summary/Keyword: contact wire

검색결과 327건 처리시간 0.029초

와이어 본더용 Horn-Holder Assembly의 접촉 해석 (Contact Analysis on a Born-Holder Assembly for Wire Bonding)

  • 장창수;안근식;김영준;곽동옥;부성운
    • 대한기계학회논문집A
    • /
    • 제26권10호
    • /
    • pp.2008-2017
    • /
    • 2002
  • Joint structure of a transducer horn-holder assembly fur a wire bonder was examined through FEM contact analysis. A three dimensional modeling and analysis was carried out to survey the internal physics of this structure and to prove the accuracy of a computation compared to a measurement. After validation, a simple two dimensional model was built fur various parametric study considering the efficiency and speed of the computation. Several factors such as boundary conditions, a modeling boundary, mesh density and so on, were considered to obtain consistency with three dimensional analysis. An arc angle and a position of each holder boss were chosen as design parameters. A design of experiment was applied to find out an optimized design of the holder geometry. As a result, a guideline for holder boss design was suggested and main factors and their influence on stress concentration in the transducer horn were surveyed.

인발 선재의 반경 방향 변형률 분포 예측 (Prediction of Radial Direction Strain in Drawn Wire)

  • 이상곤;황선광;조용재
    • 한국기계가공학회지
    • /
    • 제18권9호
    • /
    • pp.100-105
    • /
    • 2019
  • In wire drawing, aterial deformation is concentrated on the surface of the drawn wire because of surface contact with the drawing die. Therefore, strain varies from the center to the surface of the drawn wire. In this study, based on the upper bound method, an effective strain prediction method from the center to the surface of a drawn wire was proposed. Using the proposed method, the effective strain of the drawn wire was calculated verify the proposed prediction method, the predicted effective strain was compared with the result of finite element analysis.

전차선로 동적특성에 따른 설치상태 분석 (Analysis on Installation Condition According to Dynamic Characteristics for Overhead Catenary System)

  • 박영;이기원
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1605-1609
    • /
    • 2016
  • The measurement of current collection performance between pantograph and contact wire of overhead catenary system is intended to prove the safety of operation and the quality of the current collection system. The results of interaction performance of current collection system are required for approving with commercial operation on railway lines. The methods of interaction performance of current collection system are defined on interactional standards such as IEC 62486 and EN 50317. In this paper, the interaction performance is evaluated by the percentage of arcing on Honam high-speed line and the results are used for adjustment of the overhead catenary line structure. The experimental results in Honam high-speed line confirm that the duration of an arc lasting longer 25 ms between pantograph and contact wire was depended on the conditions of overhead contact line after installation.

선재 공정에서 C-Hook 트래킹을 위한 RFID 시스템 적용에 대한 연구 (A study on application of RFID systems for tracking of C-Hook in the wire rods process)

  • 권영신;이창우;반성준;조현우;김상우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.413-415
    • /
    • 2006
  • Wire rods are carried by C-Hooks and are tracked by bringing the inspection sensors into contact with steel bars on the C-Hooks. However, the conventional system using mechanical equipment is not reliable due to aging, wearing and bending of steel bars. To overcome these problems, a non-contact type identification system is required. This paper introduces the radio frequency identification(RFID) technology which is one of the most popular non-contact identification methods, and evaluates its performance in the real environment of POSCO. Specifically, we use tags which are designed for operating on high temperature and allowing easy attaching and detaching on the C-Hook. A new monitoring program is developed for reacting upon the conventional system and showing the results of reading of reading tags.

  • PDF

기존선 가동브래킷 곡선 당김 금구의 완충기능 필요성 (A Need of Buffering Function for Full-Off Fitting on Movable Bracket using Conventional Line)

  • 안영훈;김철수;이승일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.219-222
    • /
    • 2007
  • The Full-Off Fitting of Movable Bracket using conventional line have received a dynamic contact impact between contact wire and pantograph of electric rolling stock, so this impact cause a rapid vibration of foreword and back near the supporting point of movable bracket. The Full-Off Fitting on Movable Bracket in conventional line differs from that in high speed line. Now conventional line have required a speed up for new electric locomotive and electric car. In speed-up track and big impact place, the Full-Off Fitting and the dropper often get demage. We have done a study of buffering function to solve that problem in conventional line. We have find a need adopting buffer fitting. It is decrease a dynamic impact between contact wire and pantograph of electric rolling stock.

  • PDF

전차선 압상량 검출을 위한 최적 시스템 구현 (Implementation of Optimization of the Uplift Amount Measurement System of Overhead Contact Line)

  • 박영;이기원;박철민;권삼영
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.886-890
    • /
    • 2013
  • Uplift of contact wire and dynamic characteristics between pantograph and contact wire are key interaction performance of OCS (Overhead Catenary System). These two evaluation items are the approval criteria for the performance between OCS and pantograph. A telemetry system or DAQ (Data Acquisition) System based on wireless communication make it monitor a dynamic behavior which is measured directly in a 25 kv like parts. While permissible working time is too short time to install is too long. In this paper, it is described that optimization the telemetry measurement system for OCS and increasing accuracy, easy adaptation, and faster handling can be also achieved through the study.

FPGA를 이용한 전차선로 실시간 계측시스템 구현 (Implementation of FPGA-Based Real-Time data acquisition system for overhead contact wire)

  • 나해경;박영;조용현;정호성;박현준;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.531-532
    • /
    • 2006
  • This paper presents the implementation of Real-time data acquisition system for dynamic characteristics of overhead contact wire in electric railway. The reconfigurable field-programmable gate array (FPGA) and LabVIEW graphical development tools have been used to Real-time monitoring system. The results from a field test show that the proposed technique and developed system can be practically applied to measure the assessment quantity or quantities on overhead contact lines for the online real-time process monitoring.

  • PDF

선로변 전차선과 조가선의 전류를 이용한 집전성능 분석 기술 (Analysis of Current Collection Performance using Real-time Measurement of Current for Overhead Contact Line on the Track-side)

  • 박영;신승권;이기원;김재문;김원하
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.573-576
    • /
    • 2013
  • In this paper, analysis method for current collection performance based on real-time current of catenary system is proposed. An innovative method based on track-side of railway system is used for measurement of currents for overhead contact line during the collection with pantograph. The evaluation of a qualitative ratio for current collection performance were conducted using proposed algorithm under various conditions such as laboratory and track-side. To check the validity of our approach, we compared between calculation results from current of contact wire and measurement results from arcing of pantograph using simulator in laboratory conditions. The results show that the behavior of current collection performance were analysis from currents of overhead contact line in AC electric railway system.

차세대 고속전철 주행에 따른 이선현상이 전력변환 상호간에 미치는 영향분석 (An analysis of mutual influence between power conversions caused by contact loss during traction of next generation high speed train)

  • 김재문;장진영;김양수;안정준;김연준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.10-12
    • /
    • 2009
  • Electromagnetic Interference(EMI) in electric railway operation has become increasingly important. The components within very high power electronic, and the circuits for treating low-level signals, comprise complex system that must coexist and be highly reliable. To study it, It were included how much the HEMU-400X generates EMI and it has an effect on the power conversion units which resulted from Power Line Disturbance (PLD) phenomenon by contact loss during its running. In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated. The analysis of the loss of contact based on Power Simulator program software is performed to develop power line disturbance model suitable for high speed operation. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system.

  • PDF

충북선에서 전차선대 조가선의 전류 분포비에 대한 측정 결과 (Measuring results of the current distribution ratio between the contact wire and messenger wire in Chungbuk Line catenary)

  • 권삼영;박영;정호성;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.55-58
    • /
    • 2005
  • In this paper, the measuring of the current distribution ratio between catenary and messenger wire on the condition of directly applying voltage to catenary at the Chungbuk line catenary in a process of de-icing system performance test is described. measuring" method and measured data are explained. Result values are also reviewed.

  • PDF