• 제목/요약/키워드: contact time

검색결과 3,189건 처리시간 0.034초

마이크로 원형 모세관에서 계면 이동 현상의 측정 (Measurements of Flow Meniscus Movement in a Micro Capillary Tube)

  • 이석종;성재용;이명호
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.15-21
    • /
    • 2013
  • In this paper, a high-speed imaging and an image processing technique have been applied to detect the position of a meniscus as a function of time in the micro capillary flows. Two fluids with low and high viscosities, ethylene glycol and glycerin, were dropped into the entrance well of a circular capillary tube. The filling times of the meniscus in both cases of ethylene glycol and glycerin were compared with the theoretical models - Washburn model and its modified model based on Newman's dynamic contact angle equation. To evaluate the model coefficients of Newman's dynamic contact angle, time-varying contact angles under the capillary flows were measured using an image processing technique. By considering the dynamic contact angle, the estimated filling time from the modified Washburn model agrees well with the experimental data. Especially, for the lower-viscosity fluid, the consideration of dynamic contact angle is more significant than for the higher-viscosity fluid.

오존 산화가 DRAM 셀의 콘택 저항에 미치는 영향 (Effects of Ozone Oxidation on the Contact Resistance of DRAM Cell)

  • 최재승;이승욱;신봉조;박근형;이재봉
    • 한국전기전자재료학회논문지
    • /
    • 제17권2호
    • /
    • pp.121-126
    • /
    • 2004
  • In this paper, the effects of the ozone oxidation of the landing polycrystalline silicon on the cell contact resistance of the DRAM device were studied. For this study, the ozone oxidation of the landing polycrystalline silicon layer was performed under various conditions, which was followed by the normal DRAM processes. Then, the cell contact resistance and $t_{WR}$ (write recovery time) of the devices were measured and analyzed. The experimental results showed that the cell contact resistance was more significantly increased for higher temperature of oxidation, longer time of oxidation, and higher concentration of ozone in the oxidation furnace. In addition, the TEM cross-sectional micrographs clearly showed that the oxide layer at the interface between the landing polycrystalline silicon layer and the plug polycrystalline silicon layer was increased by the ozone oxidation. Furthermore, the rate of the device failure due to too large write recovery time was also found to be well correlated with the increase of the cell contact resistance.

Development of a Non-contact Input System Based on User's Gaze-Tracking and Analysis of Input Factors

  • Jiyoung LIM;Seonjae LEE;Junbeom KIM;Yunseo KIM;Hae-Duck Joshua JEONG
    • 한국인공지능학회지
    • /
    • 제11권1호
    • /
    • pp.9-15
    • /
    • 2023
  • As mobile devices such as smartphones, tablets, and kiosks become increasingly prevalent, there is growing interest in developing alternative input systems in addition to traditional tools such as keyboards and mouses. Many people use their own bodies as a pointer to enter simple information on a mobile device. However, methods using the body have limitations due to psychological factors that make the contact method unstable, especially during a pandemic, and the risk of shoulder surfing attacks. To overcome these limitations, we propose a simple information input system that utilizes gaze-tracking technology to input passwords and control web surfing using only non-contact gaze. Our proposed system is designed to recognize information input when the user stares at a specific location on the screen in real-time, using intelligent gaze-tracking technology. We present an analysis of the relationship between the gaze input box, gaze time, and average input time, and report experimental results on the effects of varying the size of the gaze input box and gaze time required to achieve 100% accuracy in inputting information. Through this paper, we demonstrate the effectiveness of our system in mitigating the challenges of contact-based input methods, and providing a non-contact alternative that is both secure and convenient.

대홍복숭아 과실주의 품질 특성에 미치는 효소와 침용 시간의 영향 (Effects of Enzyme Treatment and Skin Contact Time on the Characteristics of Dae-hong Peach Wine)

  • 임보라;김다혜;강지은;한귀정;정석태;김찬우
    • 한국식생활문화학회지
    • /
    • 제38권6호
    • /
    • pp.442-455
    • /
    • 2023
  • This study investigated the effects of pectinase treatment and skin contact time on the quality characteristics of Dae-hong peach wine. Wine was produced with variations in enzyme treatment and skin contact time (1 hour, 2 hours, 1 day, 2 days, and until the completion of fermentation). Enzyme treatment increased the production yield by 6%, as well as ethanol and redness levels, compared to the non-treated control. Volatile components were higher when the skin contact time was 2 hours or 1 day. Results were compared according to enzyme treatment and skin contact time and found to be influenced by methanol and 3-methyl-1-butanol. Enzyme treatment effectively enhanced yields and volatile compound contents. However, skin contact should be concluded a day before 1 day to ensure compliance with methanol legislative requirements. Therefore, our findings show that enzymatic treatment with shorter skin contact time preserves the distinctive characteristics of Dae-hong peaches and ensures the production of safe and flavorful wine.

비선형 헤르쯔 접촉스프링과 변위제한조건식의 적용에 의한 차량-궤도-교량 동적상호작용 수치해석기법 (Simulation of Vehicle-Track-Bridge Dynamic Interaction by Nonlinear Hertzian Contact Spring and Displacement Constraint Equations)

  • 정근영;이성욱;민경주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.191-196
    • /
    • 2005
  • In this study, to describe vehicle-track-bridge dynamic interaction phenomena with 1/4 vehicle model, nonlinear Hertzian contact spring and nonlinear contact damper are introduced. In this approach external loads acting on 1/4 vehicle model are self weight of vehicle and geometry information of running surface. The constraint equation on contact surface is implemented by Penalty method. Also, to improve the numerical stability and to maintain accuracy of solution, the artificial damper and the reaction from constraint violation are introduced. A nonlinear time integration method, in this study, Newmark method is adopted for both equations of vehicles and structure. And to reduce the error caused by inadequate time step size, adaptive time-stepping technique is partially introduced. As the nonlinear Hertzian contact spring has no resistance to tensile force, the bouncing phenomena of wheelset can be described. Thus, it is expected that more versatile dynamic interaction phenomena can be described by this approach and it can be applied to various railway dynamic problems.

  • PDF

Survival of the Insulator under the electrical stress condition at cryogenic temperature

  • Baek, Seung-Myeong;Kim, Sang-Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.10-14
    • /
    • 2013
  • We have clearly investigated with respect to the survival of the insulator at cryogenic temperature under the electrical stress. The breakdown and voltage-time characteristics of turn-to-turn models for point contact geometry and surface contact geometry using copper multi wrapped with polyimide film for an HTS transformer were investigated under AC and impulse voltage at 77 K. Polyimide film (Kapton) 0.025 mm thick is used for multi wrapping of the electrode. As expected, the breakdown voltages for the surface contact geometry are lower than that of the point contact geometry, because the contact area of the surface contact geometry is lager than that of the point contact geometry. The time to breakdown t50 decreases as the applied voltage is increased, and the lifetime indices increase slightly as the number of layers is increased. The electric field amplitude at the position where breakdown occurs is about 80 % of the maximum electric field value. The relationship between survival probability and the electrical stress at cryogenic temperature was evident.

가방 휴대 방법이 보행 시 발바닥 접촉 양상에 미치는 영향 (The Influence of Various Carrying a Pack Methods during Walking on Parameters of Foot Contact)

  • 박수진;권유정;김민희;김진상
    • 대한물리치료과학회지
    • /
    • 제18권2호
    • /
    • pp.29-40
    • /
    • 2011
  • Purpose: The purpose of this study was to analyze the changes of parameters of foot contact by various carrying a pack methods during walking. Method: The subjects were consisted of normal forty four persons (males 30, females 14, mean age 23). The carrying a pack methods were classified into five conditions: carrying no bag(Con 1), carrying a backpack(Con 2), carrying a shoulder bag(Con 3), carrying a cross bag(Con 4), carrying a one-hand bag(Con 5). All subjects were participated in these five condition and measured foot pressure by F-scan system during walking. Then foot contact time, foot contact area, foot contact length and width were measured and analyzed. The repeated one-way analysis of variance (ANOVA) was used to get difference between conditions and independent t-test was used to get difference between left and right foot within condition. Result: In the comparison of parameters of foot, contact time, contact area and mid foot width were significantly different between conditions(p<.05), and in both foot contact time at condition 5 showed the most significant reduction(p<.05). In the comparison of parameters of foot between left and right foot within condition, every conditions were not significantly different(p>.05). Conclusion: In this study various carrying methods changed the parameters of foot contact and showed significant difference in some articles between carrying methods. However, asymmetric load of pack by carrying methods didn't affected symmetry of parameters of foot contact between left and right foot.

  • PDF

평형감각자극이 정신지체아동의 시선 집중력 향상에 미치는 영향 (The Effect of Vestibular Stimulation on Eye Contact in Mentally Retarded Children)

  • 곽민숙
    • The Journal of Korean Physical Therapy
    • /
    • 제2권1호
    • /
    • pp.75-83
    • /
    • 1990
  • The purpose of this study was to determine if any differences exist in eye contact before and after vestibulaar stimulation in mentally retarded children. The subjects of this study were 20 mentally retarded children with a mean age of 9 years and 8 months and a mean intelligence quotient of $30.4{\pm}9.1$. Vestibular stimulation was given for 15 minutes, 5 times a week, for 4 weeks from September 1 to September 30, 1989. Equipment used included a rocking-horse, see-saw and scooter board. Two testers used a digital watch calibrated to 1/100 second to measure object-eye contact duration and the Blocks and Shapes test for determining frequency of object-eye contact in the subjects. The results of this study were as follows : 1. There was a significant prolongation in the duration of eye contact after 15 minutes of vestibular stimulation (p<0.005). 2. There was no significant difference in duration of eye-object contact between the first and last vestibular stimulation. 3. There was no significant difference in the length of time of attention paid to objects (frequency of eye-object contact) before and after 15 minutes of vestibular stimulation on the first vestibular stimulation. 4. There was no significant difference in the frequency of eye-object contact between the first and first vestibular stimulation. In conclusion, there was u significant improvement in duration of eye-object contact on intrasession measurement in mentally retarded children. However, there was no significant improvement over time after 4 weeks of vestibular stimulation on intersession measurement. Nor was there any statistically significant improvement in frequency of eye-object contact over time during the study period.

  • PDF

SSTDR을 이용한 케이블의 접촉 불량 고장 진단 (Diagnosis of Poor Contact Fault in the Power Cable Using SSTDR)

  • 김택희;전정채
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1442-1449
    • /
    • 2016
  • This paper proposes a diagnosis to detecting poor contact fault and fault location. Electrical fire by poor contact fault of power cable occupied a large proportion in the total electrical installations. The proposed method has an object to prevent electrical fault in advance. But detecting poor contact fault is difficult to detect fault type and fault location by using conventional reflectometry due to faults generated intermittently and repeatedly on the time change. Therefore, in this paper poor contact fault and fault conditions were defined. System generating poor contact fault produced for the experimental setup. SSTDR and algorithm of reference signal elimination heighten performance detecting poor contact fault on live power cable. The diagnosis methods of signal process and analysis of reflected signal was proposed for detecting poor contact fault and fault location. The poor contact fault and location had been detected through proposed diagnosis methods. The fault location and error rate of detection were verified detecting accuracy by experiment results.

철강재료의 다이아몬드절삭에 있어서 단속절삭가공법의 적용에 의한 공구마모억제 (Control of Tool Wear in Diamond Cutting of Steels by Intermittent Cutting Method)

  • 송영찬;근진건태랑;박천홍;삼협준도
    • 한국정밀공학회지
    • /
    • 제25권6호
    • /
    • pp.40-46
    • /
    • 2008
  • Ultraprecision cutting of steels with geometrically defined single crystal diamond tools is handicapped by excessive tool wear. This paper presents a new approach to suppress the wear of single crystal diamond tool in cutting of steels. In general, it is said that the wear of diamond tool is caused by chemically reactive wear under high temperature and high pressure conditions. In order to suppress such chemical reactions, the time of contact between the diamond tool and the steel work in cutting was controlled by employing the intermittent cutting method such as fly-cutting. Series of intermittent cutting experiments have been carried out to control the tool-work contact time by changing one cycle of cutting length and cutting speed. The experimental results were shown that the tool wear was much dependent on the contact time regardless of the cutting speed, and that the wear was much suppressed by reducing the tool-work contact time. It is expected that the steels can be successfully cut with a single crystal diamond tool by controlling the contact time.