• Title/Summary/Keyword: contact sensitivity

Search Result 253, Processing Time 0.028 seconds

Effects of organic silicone additive material on physical and mechanical properties of mudstone

  • Chai, Zhaoyun;Kang, Tianhe;Chen, Weiyi
    • Geomechanics and Engineering
    • /
    • v.6 no.2
    • /
    • pp.139-151
    • /
    • 2014
  • Mudstone is a very common rock that, when in contact with water, can exhibit considerable volume change and breakdown. This behavior of mudstone is frequently encountered in geotechnical engineering and has a considerable influence on infrastructure stability. This is particularly important in the present work, which focuses on mitigating the harmful properties of mudstone. The samples studied are of Permian Age mudstone from Shandong Province, China. Modification tests using organic silicone additive material were carried out. The mechanisms of physical properties modification of mudstone were comparatively studied using corresponding test methods, and the modification mechanism of organic silicone additive material acting on mudstone was analyzed. The following conclusions were drawn. The surface texture and characters of mudstone changed dramatically, surface character turns from hydrophilic to hydrophobic after organic silicone additive material modification. The changes in the surface character indicate a reduction in the water sensitivity of mudstone. After modification, the shape of porosity and fracture of mudstone changed unremarkable, and the total and free expansion ratios decreased obviously, whereas the strength increased markedly.

The Role of Adiponectin in the Skin

  • Oh, Jieun;Lee, Yeongyeong;Oh, Sae-Woong;Li, TianTian;Shin, Jiwon;Park, See-Hyoung;Lee, Jongsung
    • Biomolecules & Therapeutics
    • /
    • v.30 no.3
    • /
    • pp.221-231
    • /
    • 2022
  • Adiponectin (Ad), a 30 kDa molecule, is an anti-diabetic adipokine; although derived from adipose tissue, it performs numerous activities in various other tissues. It binds to its own receptors, namely adiponectin receptor 1(AdipoR1), adiponectin receptor 2 (AdipoR2), and T-cadherin (CDH13). Ad plays several roles, especially as a regulator. It modulates lipid and glucose metabolism and promotes insulin sensitivity. This demonstrates that Ad has a robust correlation with fat metabolism. Furthermore, although Ad is not in direct contact with other tissues, including the skin, it can be delivered to them by diffusion or secretion via the endocrine system. Recently it has been reported that Ad can impact skin cell biology, underscoring its potential as a therapeutic biomarker of skin diseases. In the present review, we have discussed the association between skin cell biology and Ad. To elaborate further, we described the involvement of Ad in the biology of various types of cells in the skin, such as keratinocytes, fibroblasts, melanocytes, and immune cells. Additionally, we postulated that Ad could be employed as a therapeutic target to maintain skin homeostasis.

Multi-Label Image Classification on Long-tailed Optical Coherence Tomography Dataset (긴꼬리 분포의 광간섭 단층촬영 데이터세트에 대한 다중 레이블 이미지 분류)

  • Bui, Phuoc-Nguyen;Jung, Kyunghee;Le, Duc-Tai;Choo, Hyunseung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.541-543
    • /
    • 2022
  • In recent years, retinal disorders have become a serious health concern. Retinal disorders develop slowly and without obvious signs. To avoid vision deterioration, early detection and treatment are critical. Optical coherence tomography (OCT) is a non-invasive and non-contact medical imaging technique used to acquire informative and high-resolution image of retinal area and underlying layers. Disease signs are difficult to detect because OCT images have many areas which are not related to any disease. In this paper, we present a deep learning-based method to perform multi-label classification on a long-tailed OCT dataset. Our method first extracts the region of interest and then performs the classification task. We achieve 98% accuracy, 92% sensitivity, and 99% specificity on our private OCT dataset. Using the heatmap generated from trained convolutional neural network, our method is more robust and explainable than previous approaches because it focuses on areas that contain disease signs.

Evaluation of Wear in Inconel 600 Tools in Superplastic Forming of Ti6Al4V Sheet (Ti6Al4V 판재의 초소성 성형공정에서 Inconel 600 금형 마모 평가)

  • J. Bang;J. Song;M. Kim
    • Transactions of Materials Processing
    • /
    • v.33 no.2
    • /
    • pp.112-117
    • /
    • 2024
  • In this study, the friction and wear characteristics of Inconel 600 in the superplastic forming process of Ti6Al4V were evaluated through pin-on-disc tests. To achieve an efficient and systematic experimental design, the Taguchi method was employed. The wear track of the Inconel 600 pin showed scratches in the sliding contact direction, confirming that the wear mechanism is abrasive wear. Through sensitivity analysis such as ANOVA and Main effects, it was confirmed that both normal force and sliding distance have a significant impact on the wear. Changes in sliding velocity and distance did not affect the friction coefficient, which remained relatively constant at approximately 0.380. The wear prediction model for Inconel 600 in the superplastic forming of Ti6Al4V was constructed, which can be utilized as a guideline for the prediction and management of tool wear.

Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor (중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발)

  • Jung, H.K.;Lee, D.H.;Lee, Y.S.;Huh, H;Cheong, Y.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.164-170
    • /
    • 2004
  • Liquid Injection Nozzle(LIN) tube and Calandria tube(CT) in pressurized Heavy Water Reactor (PHWR) are .ross-aligned horizontally. These neighboring tubes can contact each other due to the sag of the calandria tube resulting from the irradiation creep and thermal creep, and fuel load, etc. In order to judge the contact which might be the safety concern, the remote field eddy current (RFEC) technology is applied for the gap measurement in this paper. LIN can be detected by inserting the RFEC probe into pressure tube (PT) at the crossing point directly. To obtain the optimal conditions of the RFEC inspection, the sensitivity, penetration and noise signals are considered simultaneously. The optimal frequency and coil spacing are 1kHz and 200mm respectively. Possible noises during LIN signal acquisition are caused by lift-off, PT thickness variation, and gap variation between PT and CT. The simulated noise signals were investigated by the Volume Integral Method(VIM). Signal analysis on the voltage plane describes the amplitude and shape of LIN and possible defects at several frequencies. All the RFEC measurements in the laboratory were done in variance with the CT/LIN gap and showed the relationship between the LIN gap and the signal parameters by analyzing the voltage plane signals.

Human Health Risk Assessment of Polycyclic Aromatic Hydrocarbons (PAHs) from Road Dust Sediments in Korea (국내 도로 노면 퇴적입자 내 PAHs의 인체 위해성 평가)

  • Lee, Gain;Kim, Hongkyoung;Ji, Seungmin;Jang, Yong-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.4
    • /
    • pp.286-297
    • /
    • 2020
  • This research studied human health risk assessment of PAHs (Polycyclic Aromatic Hydrocarbons) in road dust sediments collected from 6 sites in four different cities in Korea. PAHs are well known to be human carcinogens and toxic compounds that are commonly generated from incomplete combustion of fuels and energy products. Such compounds which is absorbed by atmospheric suspended dust can be emitted into air in gaseous form and often deposited on road dust sediments. The PAHs which is deposited on sediment particles can also be re-dispersed by vehicles or winds on the road surface. It can be harmful for humans when exposed via breathing, ingestion and dermal contact. This study examined human health risk assessment of PAHs in deposited road dust sediments. Results showed that the excess cancer risk estimates were above 1.0×10-6 at main traffic roads and resident area in Ulsan city. According to the result of deterministic risk assessment, dermal-contact was the major pathway, while the contribution of the risk from inhalation was less than 1%. The probabilistic risk assessment showed similar levels of cancer risk derived from the deterministic risk assessment. The result of sensitivity analysis reveal that exposure time is the most contributing factor (69%). Since the values of carcinogenic risk assessment were higher than 1.0 × 10-6, further detailed monitoring and refined risk assessment for PAHs may be required to identify more reliable and potential cancer risks for those who live in the study locations in Ulsan city.

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Refractometric Glucose Biosensor Incorporating a Vertically Coupled Microring Resonator in Polymeric Waveguides (수직형 폴리머 마이크로링 공진기 기반의 글루코스 바이오 센서)

  • Kim, Gun-Duk;Son, Keun-Sik;Lee, Hak-Soon;Kim, Ki-Do;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.127-131
    • /
    • 2008
  • A refractometric glucose biosensor incorporating a vertically coupled microring resonator in polymers was proposed and realized. The ring was covered with a target analyte of glucose solution with a certain concentration, so that its effective refractive index could be altered and, as a result, the resonance wavelength of the sensor was shifted. Therefore the concentration of the glucose solution can be estimated by observing the shift in the resonance wavelength. Two schemes were exploited for enhancing the sensitivity of the sensor. First, the effective refractive index of the polymeric waveguide used for the resonator sensor was adjusted to approach that of the target analyte as best as possible. Second, the ring waveguide, which serves as a crucial sensing part, was appropriately over-etched to enlarge its contact area with the analyte. The proposed resonator sensor was designed with the beam propagation method. The refractive indices of the core and cladding polymer involved were 1.430 and 1.375 respectively, leading to the waveguide's effective refractive index of ${\sim}1.390$, which is faiirly close to that of the glucose solution of ${\sim}1.333$. The prepared ring resonator with the $400-{\mu}m$ radius exhibited the free spectral range of 0.66 nm, the bandwidth of 0.15 nm, and the quality factor of 10,000. For the sensor operating at 1,550 nm wavelength, the achieved sensitivity was as great as 0.28 pm/(mg/dL), which is equivalent to 200 nm/RIU.

CO Sensing Properties in Layer structure of SnO2-ZnO System prepared by Thick film Process (SnO2-ZnO계 후막센서 구조에 따른 CO 감지 특성)

  • Park, Bo-Seok;Hong, Kwang-Joon;Kim, Ho-Gi;Park, Jin-Seoung
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.155-162
    • /
    • 2002
  • The sensing properties of carbon monooxide were investigated as a function of mixing ratio and the lamination structure of 3mol% ZnO-doped $SnO_2$ and 3mol% $SnO_2$-doped ZnO. The lamination structures were fabricared monolayer, double layer, and hetero layer of $SnO_2$, Zno, and theirs mixture composition using thick film process. There was no second phase by the reaction of $SnO_2$ and ZnO. The conductance was decreased by the addition of ZnO in $SnO_2$, but it was increased with the addition of $SnO_2$ in ZnO. The conductance was increased with temperature and the inlet of CO. There was no improvement of sensitivity in the structure of mono- and double-layer. The hetero-layer structure, however, of $SnO_2$ 3ZnO-ZnO $3SnO_2$ showed the higher resistivity and the highest sensitivity. Ohmic characteristics was confirmed by the linear properties for I-V measurements.

After Contraction in Isolated Cardiac Muscle (심룡근(心朧筋)의 반복수축현상(反復收縮現象)에 관(關)하여)

  • Ryo, Ung-Yun;Brooks, Chandler Mcc.
    • The Korean Journal of Physiology
    • /
    • v.1 no.1
    • /
    • pp.67-72
    • /
    • 1967
  • Present paper is attempted to introduce the phenomenon of 'after contraction' in isolated cardiac-muscle. Papillary muscles were removed from cat right ventricle and were used as a preparation. The muscle strip was Placed in tissue bath which is kept in steady temperature of around $25^{\circ}C$ and was perfuced by Tyrode solution, saturated with 95% $O_2$ and 5% $CO_2.$ under the condition of high calcium (8.2-10.0 mM/l), low sodium (72.4-70.0 mM/l) perfusion with the administration of epinephrine (1-2 mg/l) into tile tissue bath normally triggered muscle contraction was followed by oscillatory, repetitive contractions - after contraction. The phenomenon of after contraction was augumented by decrease in tissue bath temperature and by increase in number of preceding beats and in driving rate. Authors were able to maintain the phenomenon in prominent and steady state giving proper experimental conditions such as fixed bath temperature (ranged from $22^{\circ}C\;to\;27^{\circ}C$), suitable driving rate (20 per minute in average) and perfusion of high calcium, loll sodium and 1-2 mg/l of epinephrine. In some preparations, the strength of after contraction (second contraction) reached up-to 80% of normally triggered contraction and five repetitive contractions were observed as largest number of after contractions. Intracellular action potential measured in the muscle which was beating regulary showing steady after contraction revealed no oscillating after potential in most parts of the muscle but in few cases oscillating changes of after potentials were detectable. In electrogram of the muscle preparation recorded by means of contact electrode prominent, oscillating after potentials were observable when the recorder was set at highest sensitivity. It still is not clear that whether after contraction is the phenomenon which corresponds to those changes in action potential, oscillating after potential, of the muscle preparation. Possible mechanism of the phenomenon of after contraction relating with after potential changes was proposed. Detailed results obtained from further studies on after contraction and concrete discussion on the phenomenon will be reported by authors.

  • PDF