• 제목/요약/키워드: contact sensitivity

검색결과 253건 처리시간 0.034초

Comparison of two computerized occlusal analysis systems for indicating occlusal contacts

  • Jeong, Min-Young;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.49-54
    • /
    • 2020
  • PURPOSE. The purpose of this study was to compare the performance of Accura to that of the T-scan for indicating occlusal contacts. MATERIALS AND METHODS. Twenty-four subjects were selected. Their maxillary dental casts were scanned with a model scanner. The Stereolithography files of the casts were positioned to align with the occlusal plane. Occlusal surfaces of every tooth were divided into three to six anatomic regions. T-scan and Accura recordings were made during two masticatory cycles. The T-scan and Accura images were captured at the maximum bite force and overlapped to the cast. Photographs of interocclusal records were used as the reference during overlap. The occlusal contacts were counted to compare the T-scan and Accura. McNemar's test was used for statistical significance and the corresponding P-values were calculated from a chi-square distribution with one degree of freedom. The accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Accura were calculated relative to the T-scan values as a control. RESULTS. No statistical differences (P>.05) were found between the T-scan and Accura methods. The accuracy of Accura was 75.8%, sensitivity was 82.1%, specificity was 60.1%, PPV was 82.9%, and NPV was 60.1%. CONCLUSION. Accura could be another possible option as a computerized occlusal analysis system for indicating occlusal contacts at maximum intercuspation.

Imprinted Graphene-Starch Nanocomposite Matrix-Anchored EQCM Platform for Highly Selective Sensing of Epinephrine

  • Srivastava, Juhi;Kushwaha, Archana;Singh, Meenakshi
    • Nano
    • /
    • 제13권11호
    • /
    • pp.1850131.1-1850131.19
    • /
    • 2018
  • In this paper, an electrochemical sensor for epinephrine (EP), a neurotransmitter was developed by anchoring molecularly imprinted polymeric matrix (MIP) on the surface of gold-coated quartz crystal electrode of electrochemical quartz crystal microbalance (EQCM) using starch nanoparticles (Starch NP) - reduced graphene oxide (RGO) nanocomposite as polymeric format for the first time. Use of EP in therapeutic treatment requires proper dose and route of administration. Proper follow-up of neurological disorders and timely diagnosis of them has been found to depend on EP level. The MIP sensor was developed by electrodeposition of starch NP-RGO composite on EQCM electrode in presence of template EP. As the imprinted sites are located on the surface, high specific surface area enables good accessibility and high binding affinity to template molecule. Differential pulse voltammetry (DPV) and piezoelectrogravimmetry were used for monitoring binding/release, rebinding of template to imprinted cavities. MIP-coated EQCM electrode were characterized by contact angle measurements, AFM images, piezoelectric responses including viscoelasticity of imprinted films, and other voltammetric measurements including direct (DPV) and indirect (using a redox probe) measurements. Selectivity was assessed by imprinting factor (IF) as high as 3.26 (DPV) and 3.88 (EQCM). Sensor was rigorously checked for selectivity in presence of other structurally close analogues, real matrix (blood plasma), reproducibility, repeatability, etc. Under optimized conditions, the EQCM-MIP sensor showed linear dynamic ranges ($1-10{\mu}M$). The limit of detection 40 ppb (DPV) and 290 ppb (EQCM) was achieved without any cross reactivity and matrix effect indicating high sensitivity and selectivity for EP. Hence, an eco-friendly MIP-sensor with high sensitivity and good selectivity was fabricated which could be applied in "real" matrices in a facile manner.

휘어짐센서와 관성센서를 이용한 손가락을 포함한 상지 운동 검출 (Upper Limb Motion Detection Including Fingers Using Flex Sensors and Inertial Sensors)

  • 김연준;유재하;김동연;김수찬
    • 융합신호처리학회논문지
    • /
    • 제21권3호
    • /
    • pp.101-106
    • /
    • 2020
  • 가상현실의 활용도는 게임뿐만 아니라 재활 치료와 같은 의료에서도 높아지고 있다. 편리성으로 인하여 비디오를 활용한 비접촉 방식과 핸드 헬드 타입의 마우스 등을 사용하여 상지 움직임을 감지한다. 본 논문에서는 접힌 정도에 따라 저항값이 변화되는 휘어짐센서와 공간에서의 방향 정보를 얻을 수 있는 관성센서를 사용하여 손가락 움직임과 함께 상지 동작도 획득할 수 있는 장갑을 구현하였다. 구현된 장갑에서 얻은 신호로 오픈 소스 플랫폼인 Processing을 사용하여 손가락 움직임을 포함한 상지 동작을 실시간으로 표현하였다. 각 손가락 움직임의 감도는 0.5deg, 상지 동작 감도는 0.6deg였다.

Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI

  • Yu Zhang;Woocheol Kwon;Ho Yun Lee;Sung Min Ko;Sang-Ha Kim;Won-Yeon Lee;Suk Joong Yong;Soon-Hee Jung;Chun Sung Byun;JunHyeok Lee;Honglei Yang;Junhee Han;Jeanne B. Ackman
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.829-839
    • /
    • 2021
  • Objective: To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura. Materials and Methods: Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed. Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT). Results: At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI. Conclusion: The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.

Comparison of panoramic radiography with cone beam CT in predicting the relationship of the mandibular third molar roots to the alveolar canal

  • Shahidi, Shoaleh;Zamiri, Barbod;Bronoosh, Pegah
    • Imaging Science in Dentistry
    • /
    • 제43권2호
    • /
    • pp.105-109
    • /
    • 2013
  • Purpose: Preoperative radiographic assessment of the mandibular third molars is essential to prevent inferior alveolar nerve damage during extraction. The purpose of this study was to assess the reliability of panoramic signs of association between the roots of teeth and the canal, and to compare the panoramic signs with cone beam computed tomography (CBCT) findings. Materials and Methods: CBCT images of 132 impacted mandibular third molars were evaluated to determine the association of the root to the canal. The CBCT findings were compared with the corresponding panoramic images. Logistic regression analysis was used to define the diagnostic criteria of the panoramic images. Results: Among the panoramic signs, loss of the cortical line was the most frequent radiographic sign predicting association (sensitivity: 79.31). Contact of the tooth with the canal was observed in all cases in which the loss of cortical line of the canal or darkening of the roots was found on the panoramic radiographs. Conclusion: Darkening of the roots and loss of the cortical line on panoramic radiographs might be highly suggestive of the risk of nerve injury.

Low Specific On-resistance SOI LDMOS Device with P+P-top Layer in the Drift Region

  • Yao, Jia-Fei;Guo, Yu-Feng;Xu, Guang-Ming;Hua, Ting-Ting;Lin, Hong;Xiao, Jian
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권5호
    • /
    • pp.673-681
    • /
    • 2014
  • In this paper, a novel low specific on-resistance SOI LDMOS Device with P+P-top layer in the drift region is proposed and investigated using a two dimensional device simulator, MEDICI. The structure is characterized by a heavily-doped $P^+$ region which is connected to the P-top layer in the drift region. The $P^+$ region can modulates the surface electric field profile, increases the drift doping concentration and reduces the sensitivity of the breakdown voltage on the geometry parameters. Compared to the conventional D-RESURF device, a 25.8% decrease in specific on-resistance and a 48.2% increase in figure of merit can be obtained in the novel device. Furthermore, the novel $P^+P$-top device also present cost efficiency due to the fact that the $P^+$ region can be fabricated together with the P-type body contact region without any additional mask.

Standard Implementation for Privacy Framework and Privacy Reference Architecture for Protecting Personally Identifiable Information

  • Shin, Yong-Nyuo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제11권3호
    • /
    • pp.197-203
    • /
    • 2011
  • Personal Identifiable Information (PII) is considered information that identifies or can be used to identify, contact, or locate a person to whom such information pertains or that is or might be linked to a natural person directly or indirectly. In order to recognize such data processed within information and communication technologies such as PII, it should be determined at which stage the information identifies, or can be associated with, an individual. For this, there has been ongoing research for privacy protection mechanism to protect PII, which now becomes one of hot issues in the International Standard as privacy framework and privacy reference architecture. Data processing flow models should be developed as an integral component of privacy risk assessments. Such diagrams are also the basis for categorizing PII. The data processing flow may not only show areas where the PII has a certain level of sensitivity or importance and, as a consequence, requires the implementation of stronger safeguarding measures. This paper propose a standard format for satisfying the ISO/IEC 29100 "Privacy Framework" and shows an implementation example for privacy reference architecture implementing privacy controls for the processing of PII in information and communication technology.

Au 나노입자가 코팅된 그래핀 기반 CO2 가스센서의 제작과 그 특성 (Fabrication of CO2 Gas Sensors Using Graphene Decorated Au Nanoparticles and Their Characteristics)

  • 배상진;김강산;정귀상
    • 센서학회지
    • /
    • 제22권3호
    • /
    • pp.197-201
    • /
    • 2013
  • This paper describes the fabrication and characterization of graphene based carbon dioxide ($CO_2$) gas sensors. Graphene was synthesized by thermal decomposition of SiC. The resistivity $CO_2$ gas sensors were fabricated by pure graphene and graphene decorated Au nanoparticles (NPs). The Au NPs with size of 10 nm were decorated on graphene. Au electrode deposited on the graphene showed Ohmic contact and the sensors resistance changed following to various $CO_2$ concentrations. Resulting in resistance sensor using pure graphene can detect minimum of 100 ppm $CO_2$ concentration at $50^{\circ}C$, whereas Au/graphene can detect minimum 2 ppm $CO_2$ concentration at same at $50^{\circ}C$. Moreover, Au NPs catalyst improved the sensitivity of the graphene based $CO_2$ sensors. The responses of pure graphene and Au/graphene are 0.04% and 0.24%, respectively, at $50^{\circ}C$ with 500 ppm $CO_2$ concentration. The optimum working temperature of $CO_2$ sensors is at $75^{\circ}C$.

Highly Sensitive Multichannel Interdigitated Capacitor Based Bitterness Sensor

  • Khan, Md. Rajibur Rahaman;Kang, Shin-Won
    • 센서학회지
    • /
    • 제27권2호
    • /
    • pp.69-75
    • /
    • 2018
  • In this study, we propose a multichannel interdigitated capacitor (IDC) sensor for detecting the bitterness of coffee. The operating principle of the device is based on the variation in capacitance of a sensing membrane in contact with a bitter solution. Four solvatochromic dyes, namely, Nile red, Reichardt's dye, auramine-O, and rhodamine-B, were mixed with polyvinylchloride (PVC) and N,N-dimethylacetamide (DMAC), to create four different types of bitter-sensitive solutions. These solutions were then individually inserted into four interdigitated electrodes (IDEs) using a spin coater, to prepare four distinct IDC sensors. The sensors are capable of detecting bitterness-inducing chemical compounds in any solution, at concentrations of approximately $1{\mu}M$ to 1 M. The sensitivity of the IDC bitterness sensor containing the Reichardt's dye sensing-membrane was approximately 1.58 nF/decade. The multichannel sensor has a response time of approximately 6 s, and an approximate recovery time of 5 s. The proposed sensor offers a stable sensing response and linear sensing performance over a wide measurement range, with a correlation coefficient ($R^2$) of approximately 0.972.

견모낭충증(犬毛囊蟲症)의 동거감염(同居感染)에 관한 연구(硏究)(I) (Studies on the contact infection of canine demodicosis(I))

  • 이채용;이정길;서계원
    • 대한수의학회지
    • /
    • 제32권3호
    • /
    • pp.407-412
    • /
    • 1992
  • In order to obtain basic data concerning the treatment of canine demodicosis, 8 Doberman Pinschers were infected with Demodex canis. The clinical signs, were examined after infection, and their hematological and blood chemical values were determined, along with four non-infected control dogs of same breed. The number of white blood cells, especially the number of band neutrophils was significantly higher(p<0.01) in the infected than in the non-infected control dogs. This result indicated that the first episode of secondary infection should be treated with an appropriate antibiotics based on the culture and sensitivity test. The red blood cell counts, packed cell volume, hemoglobin contents, and serum albumin levels were significantly lower (p<0.01~0.001) in the infected than in the non-infected control dogs. These results suggested that the infected dogs had an anemia due to malnutrition. Thus, the infected dogs should be on a well balanced, high protein diet.

  • PDF