• Title/Summary/Keyword: contact sensitivity

Search Result 253, Processing Time 0.042 seconds

The analysis of interferometry fringe pattern under shearing quantity and inside pressure change for inspect inside defects using by digital shearography (Digital shearography를 이용한 내부결함 검출에 있어서 전단량과 내부압력 변화에 따른 간섭줄무늬 패턴 분석)

  • 김형택;김경석;홍진후;강기수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.140-143
    • /
    • 2001
  • Digital shearography, a speckle pattern method is based on the superposition of two laterally sheared images. Therefore, object points which are positioned in some distance from each other are superposed in the image plane. This shearography, one of NDT methods without contact, is able to inspect defects in pipelines and pressure vessels that are used in nuclear power plants. This is can inspect whole fields and has a low sensitivity to environmental noise. Because optical setting is very simple, it has a little exhaustion of time, cost and man power. And also it can find a defect position through real time monitoring of a part. This paper, finds out the relationship among shearing quantity image quality and defect size with this method.

  • PDF

SENSORS IN DEVURRING AUTOMATION

  • Lee, Seoung-Hwan
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.560-564
    • /
    • 1999
  • Burr sensing for burr size measurement and deburring process control is one of the essential elements in an automated deburring procedure. This paper presents the implementation of capacitance sensing and acoustic emission (AE) to deburring. The first application is the "on-line" measurement of burrs using a capacitance sensor. A non-contact capacitance gauging sensor is attached to an ultra precision milling machine which was used as a positioning system. The setup is used to measure burr profiles along machined workpiece edges. The proposed scheme is shown to be accurate, easy to setup, and with minor modifications, readily applicable to automatic deburring processes. As the second example, AE signals were sampled and analyzed for the sensor feedback of a precision deburring process - laser deburring -. The results, such as the sensitivity of AE signals to burr shapes and edge detection capability show a clear correlation between physical process parameters and the AE signals. A subsequent control strategy for deburring automation is also briefly discussed.

  • PDF

An Algorithm for the Characterization of Surface Crack by Use of Dipole Model and Magneto-Optical Non-Destructive Inspection System

  • Lee, Jin-Yi;Lyu, Sung-Ki;Nam, Young-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.10
    • /
    • pp.1072-1080
    • /
    • 2000
  • Leakage magnetic flux (LMF) is widely used for non-contact detection of cracks. The combination of optics and LMF offers advantages such as real time inspection, elimination of electrical noise, high spatial resolution, etc. This paper describes a new nondestructive evaluation method based on an original magneto-optical inspection system, which uses a magneto-optical sensor, LMF, and an improved magnetization method. The improved magnetization method has the following characteristics: high observation sensitivity, independence of the crack orientation, and precise transcription of the geometry of a complex crack. The use of vertical magnetization enables the visualization of the length and width of a crack. The inspection system provides the images of the crack, and shows a possibility for the computation of its depth.

  • PDF

Impact Damage of Brittle Materials by Small Spheres (ll ) (취성재료의 소구충돌에 의한 충격손상 (ll))

  • Kim, Mun-Saeng;Sin, Hyeong-Seop;Lee, Hyeon-Cheol;U, Su-Chang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.153-159
    • /
    • 2002
  • Brittle materials such as ceramics and glasses show fragile fracture due to the low toughness and the crack sensitivity. When brittle materials are subjected to impact loading by small spheres, high contact pressure occurs to the surface of the specimen. Local damage is subsequently generated in the specimen. This local damage is a dangerous factor which gives rise to the final fracture of structures. In this research, impact damage of soda-lime glass plates by small spheres was evaluated by considering the effects of impact directions of indenter, pressure condition of specimen and residual strength after impact loading.

The modeling of the IPT system used for PRT (Personal Rapid Transmit) (소형궤도 차량용 유도전력급전 계통 모델링)

  • Lee Byung-Song;Bae Chang-Han;Byun Yeun-Sub;Han Kyung-Hee
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1413-1418
    • /
    • 2004
  • This paper shows the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system, electrical power is transferred from a primary winding in the form of a coil or track, to one or more isolated pick-up coils that may relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. The coupling between the primary and secondary is then presented to include the effects of parameter and operational frequency variation.

  • PDF

The Characteristic analysis of the IPT system used for PRT(Personal Rapid Transmit) (소형궤도차량 유도전력급전 계통 특성해석)

  • Lee, B.S.;Kim, Do-Won;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.218-220
    • /
    • 2005
  • This paper shows the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system, electrical power is transferred from a prima교 winding in the form of a coil or track, to one or more isolated pick-up coils that may relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. The coupling between the primary and secondary is then presented to include the effects of parameter and operational frequency variation.

  • PDF

Displacement measurement sensor using astigmatic confocal technology

  • J.W. Seo;D.K. Kang;Lee, J.H.;Kim, D.M.;D.G. Gweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.163.2-163
    • /
    • 2001
  • Confocal scanning microscopy (CSM) has been reported as an excellent method using the optical probe in scanning probe microscopy (SPM). Transmission or reflection confocal scanning microscopy (TCSM, RCSM) has been used in the three-dimensional reconstruction of specimen or the non-destructive measurement in vivo. The axial movement of the primary focal point having the information of specimen gives a good measurement performance with the great sensitivity. Application of the confocal theory and astigmatism to displacement measurement sensor uses the aperture as the pinhole or slit after collecting lens relating to confocal response in non-contact measurement; and astigmatic lens using four-segments detector as short-range sensor, long-range one combining the grating and rotary one hating the rotary directional grating. The aperture type can play an ...

  • PDF

Novel Detection Algorithm of The Upstroke of Pulse Waveform for Continuously Varying Contact Pressure Method (연속 가압방식의 맥파 측정방법을 위한 시작점 검출 알고리즘 개발)

  • Bae, Jang-Han;Jeon, Young-Ju;Kim, Jong-Yeol;Kim, Jae-Uk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.46-54
    • /
    • 2012
  • We propose a continuously varying contact pressure(CVCP)-adaptive feature extraction algorithm for pulse diagnostic analysis. The CVCP method measures the pulse waveform with continuously increasing contact pressure(CP). This method offer a high resolution signal of the pulse waveform amplitude(PWA) as a function of the contact pressure. Therefore it enables us to overcome the limitation of commercially available pulse-taking devices whose analysis rely on a few number of PWA-CP pairs. We show that an efficient feature extraction algorithm which covers the features of the CVCP-method can be developed by sequentially applying Fast Fourier Transform, peak detection by center-to-edges method, baseline drift removal, detection of the percussion wave upstroke by intersecting tangent method and detection of the analysis region. Finally, by a clinical study with 30 subjects, we show that our CVCP-adaptive feature extraction algorithm detected the upstroke with accuracy of 99.46% and sensitivity of 99.51%, which were about 4.82% and 2.46% increases respectively, compared to a conventional feature extraction method. The proposed CVCP method and the CVCP-adaptive feature extraction algorithm are expected to improve the accuracy in the pulse diagnostic algorithms such as floating/sunken pulse qualities and deficient/excess pulse qualities.

Experimental Validation of Isogeometric Optimal Design (아이소-지오메트릭 형상 최적설계의 실험적 검증)

  • Choi, Myung-Jin;Yoon, Min-Ho;Cho, Seonho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.345-352
    • /
    • 2014
  • In this paper, the CAD data for the optimal shape design obtained by isogeometric shape optimization is directly used to fabricate the specimen by using 3D printer for the experimental validation. In a conventional finite element method, the geometric approximation inherent in the mesh leads to the accuracy issue in response analysis and design sensitivity analysis. Furthermore, in the finite element based shape optimization, subsequent communication with CAD description is required in the design optimization process, which results in the loss of optimal design information during the communication. Isogeometric analysis method employs the same NURBS basis functions and control points used in CAD systems, which enables to use exact geometrical properties like normal vector and curvature information in the response analysis and design sensitivity analysis procedure. Also, it vastly simplify the design modification of complex geometries without communicating with the CAD description of geometry during design optimization process. Therefore, the information of optimal design and material volume is exactly reflected to fabricate the specimen for experimental validation. Through the design optimization examples of elasticity problem, it is experimentally shown that the optimal design has higher stiffness than the initial design. Also, the experimental results match very well with the numerical results. Using a non-contact optical 3D deformation measuring system for strain distribution, it is shown that the stress concentration is significantly alleviated in the optimal design compared with the initial design.

Evaluation and Comparison with Standard 48 hr Acute Bioassay and High Temperature Rapid Toxicity Test for Sewage Toxicity Test (하수의 독성평가를 위한 표준독성시험법과 온도증가 단기독성평가법의 비교 평가)

  • Lee, Sang-Ill;Jun, Byong-Hee;Weon, Seung-Yeon;Kim, Yi-Jung;Kim, Keum-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.191-197
    • /
    • 2005
  • A new method, ToxTemp (TOXcity test based on TEMPerature control) using Ceridaphnia dubia was applied to evaluate the toxicity of insecticide materials and compared with the standard 48 hr acute bioassay. BPMC, diazinon and fenitrothion may cause the inhibition to the biological process in sewage treatment plant and need to detect toxicity within short contact time. The ToxTemp method showed sensitive detection with more shorter contact of 1-1.5 hr time than that of the standard 48 hr acute bioassay. To evaluate toxicity of real wastewater/sewage, the inhibition rate of nitrification and oxygen uptake rate (OUR) using activated sludge, the standard 48hr acute bioassay and ToxTemp method using C. dubia were compared, respectively. On the basis of the inhibition rate of nitrification, the OUR test showed the less sensitive results at the relatively strong toxic sewage. On the other hands, the standard 48hr acute bioassay and ToxTemp method using C. dubia represented the toxicity of each wastewater/sewage with high sensitivity. Even the slightly low (about 1.5%) sensitivity, the ToxTemp method showed the high applicability to the real site of sewage treatment plant.