• 제목/요약/키워드: contact fatigue strength

검색결과 64건 처리시간 0.023초

대기부식에 의한 가선재의 열화특성 (Degradation Properties of Catenary Wires on the Atmospheric Corrosion)

  • 김용기;장세기;정우성;이덕희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.590-596
    • /
    • 2002
  • Contact wires are made by metallic materials and exposured at atmosphere. We have investigated mechanical properties and the present condition of air pollution as to the messenger wires and ACSR wires of these contact wires. Mechanical properties between new contact wires and used, the used one's tensile strength and elongations was decreased by effect from corrosion. We observed a fatigue properties which was investigated by fatigue test because contact wires were affected with amplitude vibration everytime the train passed through the railways. In the evaluation of fatigue test, it was also shown that fatigue life of the used wires was decreased 50 ∼ 60% compared with that of new ones in average by effect from corrosion.

  • PDF

SM 30 C강의 중공 중실축 단면변화 부식피로강도에 미치는 영향 (The influence of the hollow and solid shaft cross sectionof SM 30 C steel on corrosion fatigue strength)

  • 신규동;장백선;김웅집
    • 한국해양공학회지
    • /
    • 제11권2호
    • /
    • pp.28-38
    • /
    • 1997
  • The corrosion fatigue test was conducted in air to investigate the corrosion fatigue strength of SM 30 C steel by which was corroded in the under sea and surface in the conditions of 3.0% NaCl salt solution. The fatigue tests were carried out on a rotary bending testing machine of cantilever type. The corrosion effect of the sea surface conditionwas served more than that of the under sea condition which was due ti the periodic contact of air thus accelerate the corrosion. The difference of the fatgue strength between sea surface and under sea conditions decreased with increase of stree level and corroded period. Inthe case of the solid shaft and thickness 2mm of hollow shaft, the difference of corrosion fatigue strength decreased as stress level and corrosion periodic increasing. Onthe contrary in the case of thickness 1mm of hollow sgaft, the difference of it increased as stress level, corrosionn periooodic increasing and also the condition of corrosion chaanged. The main factors affecting the degradation of fatigue strength due to corrosion were the reduction of sectional area and the increase of surface roughness. The interference phenomenon increase with stress level got higher.

  • PDF

고강도 알루미늄 합금의 Fretting Fatigue에 관한 연구 (A Study on Fretting Fatigue of High Strength Aluminum Alloys)

  • 이학선;김상태;최성종;양현태;김재경;이동석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.168-173
    • /
    • 2004
  • Fretting is a kind of surface degradation mechanism observed in mechanical components and structures. The fretting damage decrease in 50-70% of the plain fatigue strength. This may be observed in aircraft, automobile and nuclear power plant used in special environment and various loading conditions. In the present study, the characteristics of the fretting fatigue are investigated using the two aluminum alloy(Al2024-T3511 and Al7050-T7451). Through the experiment, it is found that the fretting fatigue strength of the Al7050-T7451 alloy decreased about 50% from the plain fatigue strength, while the fretting fatigue strength of the Al2024-T3511 alloy decreased about 45%. The tire track was widely observed in fracture surface area of oblique crack which was induced by contact pressure. These results can be the basic data to the structural integrity evaluation of aluminum alloy subjected to fretting damage.

  • PDF

소형 수문용 랙-피니언의 접촉 피로수명 (Contact Fatigue Life of Rack-Pinion for Small-Sized Sluice Gate)

  • 권순만
    • 한국생산제조학회지
    • /
    • 제26권3호
    • /
    • pp.299-305
    • /
    • 2017
  • Gate-lifting devices in small- to mid-sized sluice gates mostly employ the mechanical roller rack pinion (RRP) system. This RRP system, which consists of a rack-bar and a pinion, transforms a rotation motion into a linear one. The rack-bar has a series of roller trains that mesh with the pinion. In this study, we adopt an exact involute-trochoid tooth profile of the pinion to obtain a higher contact fatigue strength using the profile modification coefficient. Further, we determine the contact forces and investigate Hertz contact stresses to predict the pitting life of the pinion according to varying the shape design parameters. The results indicate that the design fatigue life of an RRP system for sluice gate can be achieved only when the design value of the profile modification coefficient reaches or exceeds a certain level.

유한요소법을 이용한 치아 임플랜트 피로수명 예측 (FATIGUE LIFE ESTIMATION OF IMPLANT USING A FINITE ELEMENT METHOD)

  • 한인숙;손정훈;양영수;이승영
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.414-420
    • /
    • 2006
  • Purpose : The purpose of this study is to use finite element analysis to predict the fatigue life of an implant system subjected to fatigue load by mastication (chewing force). The reliability and the stability of implant system can be defined in terms of the fatigue strength. Not only an implant is expensive but also it is almost impossible to correct after it is inserted. From a bio-engineering standpoint, the fatigue strength of the dental implant system must be evaluated by simulation (FEA). Material and Methods Finite element analysis and fatigue test are performed to estimate the fatigue strength of the implant system. Mesh of implant is generated with the actual shape and size. In this paper, the fatigue strength of implant system is estimated. U-fit (T. Strong, Korea, internal type). The stress field in implant is calculated by elastic-plastic finite element analysis. The equivalent fatigue stress, considering the contact and preload stretching of a screw by torque for tightening an abutment, is obtained by means of Sine's method. To evaluate the reliability of the calculated fatigue strength, fatigue test is performed. Results: A comparison of the calculated fatigue strength with experimental data showed the validity and accuracy of the proposed method. The initiation points of the fatigue failure in the implant system exist in the region of high equivalent fatigue stress values. Conclusion: The above proposed method for fatigue life estimation tan be applied to other configurations of the differently designed and improved implant. In order to prove reliability of prototype implant, fatigue test should be executed. The proposed method is economical for the prediction of fatigue life because fatigue testing, which is time consuming and precision-dependent, is not required.

Y$_2$O$_3$ 를 첨가한 정방정 지르코니아에서의 접촉손상 및 강도저하 (Contact Damage and Strength Degradation of Yttria doped Tetragonal Zirconia Polycrystal)

  • 정연길;최성철
    • 한국세라믹학회지
    • /
    • 제35권5호
    • /
    • pp.429-436
    • /
    • 1998
  • The mechanical properties and damage mode of {{{{ {Y}_{2 } {O}_{3} }}-doped tetragonal (Y-TZP) can-didated as biomaterials were performed under indentation stress-strain curve critical load for yield and cracking strength degradation and fatigue behavior with Hertzian indentation tests. This material shows the brittle behavior which is confirmed by indentation stress-strain response. The critical load for cracking(Pc) is much higher than that for yields (Py) indicating crack resistance Strength were strongly dependant on contact area and there were no degradation when the indenter size was ${\gamma}$=3.18 mm suggesting that Y-TZP should be highly damage tolerant to the blunt contacts. Multi-cycle contact were found to be innocuous up to {{{{ {10 }^{6 } }} cycles at 500N and {{{{ {10 }^{5 } }} cycles at 1000N in water. On the other hand contacts at {{{{ {10 }^{6 } }} cycles at 1000 N in water did show some signs of incipient degradation. By contrast contacts with Vickers indenter pro-duced substantial strength losses at much lower loads suggesting that the mechanical integrity of this ma-terial would be compromised by inadvertent sharp contacts.

  • PDF

가설환경에 따른 조가선의 피로수명 특성 (Fatigue Life Properties of Messenger Wire with Service Environments)

  • 김용기;장세기;조성일
    • 한국철도학회논문집
    • /
    • 제6권1호
    • /
    • pp.21-28
    • /
    • 2003
  • Environment-dependent fatigue life of Cu-Cd alloy wires used as messenger wires was investigated. Tensile test results showed the decrease of tensile strength and elongation of messenger wires by 3.7% and 16.8%, respectively, in used specimens when compared to new ones. Messenger wires used at industrial region for 26 yeras showed 35∼50% decrease in fatigue life, which is partly due to the in stress concentrations by formation of corrosion products at the surface. Single wires showed better fatigue properties than stranded wires, especially at low cycle regions with higher stresses. Stranded wires showed shorter fatigue lives than single wires because of friction between wires by surface contact. Service life of messenger wires was dependent upon the environments which they were exposed to. SO$_2$ and humidity deteriorated the fatigue properties by environmental degradation.

치아용 세라믹스에서의 접촉피로 및 강도저하 (Contact fatigue and strength degradation in dental ceramics)

  • 정연길;이수영;최성철
    • 한국결정성장학회지
    • /
    • 제9권5호
    • /
    • pp.527-533
    • /
    • 1999
  • 치아용 대체재료로 사용되고 있는 세 가지의 세라믹스, 장석질 자기, 운모를 함유한 유리-세라믹 및 유리침윤 알루미나에 대한 접촉피로을 실제 치아의 접촉상황과 유사한 구형입자를 이용한 헤르지안 압입시험법으로 물에서 수행하였으며, 각 재료에서의 접촉손상이 강도에 미치는 영향을 고찰하였다. 초기의 손상형태는 각 재료가 갖는 미세구조에 의존하여 나타났으며, 장석질 자기는 취성거동을 나타내는 cone 형태의 균열이, 운모를 함유한 유리-세라믹은 준-소성 변형 거동을 나타내는 변형이, 그리고 유리침윤 알루미나는 두 재료의 중간거동을 나타내었다. 그러나 반복하중의 수(n=1~n=$10^6$)가 증가됨에 따라 모든 재료에서 급격한 강도저하를 나타내었으며, 파괴는 접촉피로에 의해 형성된 손상에서 일어났다. 일정하중(200N, 500N 및 1000N)에서 반복하중의 수가 증가됨에 따라 두 번의 강도저하가 일어났으며, 첫 번째의 강도저하는 cone 형태의 균열이 주 요인으로 작용되었으며, 두 번째 강도저하는 반복하중에 따른 radial 형태의 균열에 의해 일어났다. 이러한 radial 형태의 균열발생은 각 재료에서 급격한 강도저하를 가져왔으며, 계속적인 반복하중으로 재료의 파괴를 유발시켰다. 반복하중의 수를 고정시킨 수 압입하중의 변화에 따른 강도저하에 대한 고찰을 통해 장석질 자기가 접촉피로에 대한 손상내구성을 갖음을 알 수 있었다.

  • PDF

미소슬립을 고려한 압입 시편의 접촉응력 해석 (Contact Stress Analysis of Shrink-fitted Specimen considering Micro-slip)

  • 이동형;구병춘;이찬우;정흥채
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.632-637
    • /
    • 2004
  • In the shrink or press fitted shaft such as railway axle, fretting can occur by cyclic stress and micro-slippage due to local movement between the shaft and the hub. When the fretting occurs in the press fitted shaft, the fatigue strength remarkably decreases compared with that of without fretting. In this paper, the analysis of contact stresses in a press fitted shaft in contact with a hub was conducted by finite element method and the micro-slip according to the bending load was analyzed. It is found that the largest stress concentration and maximum slip amplitude of shrink fitted shaft are found at the edge of the interface and the distribution of contact stresses at the contact edge has largely influenced and coefficient of friction.

  • PDF

Surface Densification Coupled with Higher Density Processes Targeting High-performance Gearing

  • Hanejko, Francis;Rawlings, Arthur;King, Patrick;Poszmik, George
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.738-739
    • /
    • 2006
  • This paper will describe a powder and processing method that facilitates single press-single sintered densities approaching $7.5g/cm^3$. At this sintered density, mechanical properties of the powder metal (P/M) component are significantly improved over current P/M technologies and begin to approach the performance of wrought steels. High performance gears have the added requirement of rolling contact fatigue durability that is dependent upon localized density and thermal processing. Combining high density processing of engineered P/M materials with selective surface densification enables powder metal components to achieve rolling contact fatigue durability and mechanical property performance that satisfy the performance requirements of many high strength automotive transmission gears. Data will be presented that document P/M part performance in comparison to conventional wrought steel grades.

  • PDF