Micro-finite element and analytical investigations of seismic dampers with steel ring plates

  • Rousta, Ali Mohammad;Azandariani, Mojtaba Gorji
    • Steel and Composite Structures
    • /
    • v.43 no.5
    • /
    • pp.565-579
    • /
    • 2022
  • This study investigated the yielding capacity and performance of seismic dampers constructed with steel ring plates using numerical and analytical approaches. This study aims to provide an analytical relationship for estimating the yielding capacity and initial stiffness of steel ring dampers. Using plastic analysis and considering the mechanism of plastic hinge formation, a relation has been obtained for estimating the yielding capacity of steel ring dampers. Extensive parametric studies have been carried out using a nonlinear finite element method to examine the accuracy of the obtained analytical relationships. The parametric studies include investigating the influence of the length, thickness, and diameter of the ring of steel ring dampers. To this end, comprehensive verification studies are performed by comparing the numerical predictions with several reported experimental results to demonstrate the numerical method's reliability and accuracy. Comparison is made between the hysteresis curves, and failure modes predicted numerically or obtained/observed experimentally. Good agreement is observed between the numerical simulations and the analytical predictions for the yielding force and initial stiffness. The difference between the numerical models' ultimate tensile and compressive capacities was observed that average of about 22%, which stems from the performance of the ring-dampers in the tensile and compression zones. The results show that the steel ring-dampers are exhibited high energy dissipation capacity and ductility. The ductility parameters for steel ring-damper between values were 7.5 to 4.1.

Quality Improvement to Prevent Shifting Error of Tracked Vehicles (궤도차량 변속오류 예방을 위한 품질개선)

  • Yun, Sunghyun;Baek, Hyun Moo;Park, Dong Min;Oh, Dong-Kyo
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.2
    • /
    • pp.297-313
    • /
    • 2023
  • Purpose: The purpose of this study is to investigate the causes of shifting errors reported in military tracked vehicles and to improve related quality to prevent recurrence. Methods: A systematic disassembly and inspection of the transmission is carried out and an experimental simulation is conducted to reproduce the shifting error phenomenon. Electrical characteristic tests are subsequently performed and microscopic observation is also carried out on the disassembled connector parts such as pins and fractured surfaces. Results: Oil contamination and swelling deformation are observed in the connector to the vehicle due to oil leakage of its counterpart connector to the transmission. This causes electrical contact failure between both connectors in the fastened state, and it is found that shifting error of the tracked vehicle could occur subsequently. To prevent the recurrence of this phenomenon, comprehensive quality improvement is conducted including product improvement of the wiring harness assembly and strengthening activities for quality control and preventive maintenance. Conclusion: This study is expected to be helpful as a prior case study for cause analysis and recurrence prevention in the event of similar cases in the future.

Estimating the maximum pounding force for steel tall buildings in proximity subjected to wind

  • Tristen Brown;Ahmed Elshaer;Anas Issa
    • Wind and Structures
    • /
    • v.39 no.1
    • /
    • pp.47-69
    • /
    • 2024
  • Pounding of structures may result in considerable damages, to the extent of total failure during severe lateral loading events (e.g., earthquakes and wind). With the new generation of tall buildings in densely occupied locations, wind-induced pounding becomes of higher risk due to such structures' large deflections. This paper aims to develop mathematical formulations to determine the maximum pounding force when two adjacent structures come into contact. The study will first investigate wind-induced pounding forces of two equal-height structures with similar dynamic properties. The wind loads will be extracted from the Large Eddy Simulation models and applied to a Finite Element Method model to determine deflections and pounding forces. A Genetic Algorithm is lastly utilized to optimize fitting parameters used to correlate the maximum pounding force to the governing structural parameters. The results of the wind-induced pounding show that structures with a higher natural frequency will produce lower maximum pounding forces than those of the same structure with a lower natural frequency. In addition, taller structures are more susceptible to stronger pounding forces at closer separation distances. It was also found that the complexity of the mathematical formula from optimization depends on achieving a more accurate mapping for the trained database.

LABORATORY STUDIES ON MIC OF AISI TYPE 304 STAINLESS STEEL USING BACTERIA ISOLATED FROM A W ASTEWATER TREATMENT SYSTEM

  • Sreekumari, Kurissery R.;Kyozo, Hirotani;Katsuya, Akamatsu;Takashi, Imamichi;Yasushi, Kikuchi
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.260-265
    • /
    • 2002
  • Microbiologically influenced Corrosion (MIC) is one of the most deleterious effects of metal microbe interactions. When a fresh metal surface comes in contact with a non-sterile fluid, biofilm formation is ensued. This might result in the initiation of corrosion. The sites and materials where MIC is implicated are versatile. Industries such as shipping, power generation, chemical etc are reported to be affected. The rapid and unexpected failure of AISI type 304 stainless steel was investigated in the laboratory by simulation studies for a period of 4 months. Slime and water samples from the failure site were screened for corrosion causing bacteria. Both aerobic and anaerobic nora were enumerated and identified using PCR techniques. Pseudomonas sp. and Bacillus sp. were the most common aerobic bacteria isolated from the water and slime samples, whilst sulfate reducing bacteria (SRB) were the major anaerobic bacteria. The aerobic bacteria were used for the corrosion experiments in the laboratory. Coupon exposure studies were conducted using a very dilute (0.1%V/V) nutrient broth medium. The coupons after retrieval were observed under a Scanning Electron Microscope (SEM) for the presence of MIC pits. Compared to sterile controls, metal coupons exposed to Pseudomonas sp and Bacillus sp. showed the initiation of severe pitting corrosion. However, amongst these two strains, Psudomonas sp. caused pits in a very short span of 14 days. Towards the end of the experiment, severe pitting was observed in both the cases. The detailed observation of pits showed they vary both in number and shapes. Whilst the coupons exposed to Bacillus sp. showed widely spread scales like pits, those exposed to Pseudomonas sp. showed smaller and circular pits, which had grown in number and size by the end of the experiment. From these results it is inferred that the rapid and unexpected failure of 304 SS might be due to MIC. Pseudonwnas sp. could be considered as the major responsible bacteria that could initiate pits in the metallic structures. As the appearance of pits was different in both the tested strains, it was thought that the mechanisms of pit formation are different. Experiments on these lines are being continued.

  • PDF

Analysis of Problems of Food Service Establishments Contributing to Food Poisoning Outbreaks Discovered through the Epidemiological Studies of Some Outbreaks (식중독 발생의 사례 통해 본 집단급식의 문제접 분석)

  • 김종규
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.3
    • /
    • pp.240-253
    • /
    • 1997
  • The main problems contributing to food poisoning outbreaks in institutional settings and a home were reviewed and analyzed through the epidemiological investigations of food poisoning. The major documented factors included improper holding temperatures, inadequate cooking, poor personal hygiene, cross-contamination and contaminated equipment, food from unsafe sources, failure to follow food hygiene policies, and lack of education, training, monitoring and superivision. Usually more than one factor contributed to the development of an outbreak. (1) Use of improper holding temperatures was the single most important factor contributing to food poisoning. They included improper cooling, allowing a laps of time (12 hours or more) between preparing food and eating it, improper hot holding, and inadequate or improper thawing. Food thermometers were not used in most of the instances. (2) In inadequate cooking, the core temperature of food during and after cooking had not been measured, and routine monitoring was limited to recording the temperature of plated meals. Compared with conventional methods of cooking, microwave ovens did not protect against food poisoning as effectively. Centralized food preparation potentially increased the risk of food poisoning outbreaks. (3) Poor personal hygiene both at the individual level (improper handwashing and lack of proper hygienic practices) and at the institutional level (poor general sanitization) increased the risk of transmission. Person to person transmission of enteric pathogens through direct contact and via fomites has been noted in several instances. (4) Obtaining food from unsafe sources was a risk factor in outbreaks of food poisoning. Food risks were high when food was grown or harvested from contaminated areas. Possibilities included contamination in the field, in transport, at the retail site, or at the time it was prepared for serving. (5) Cross-contamination and inadequate cleaning/handling of equipment became potential vehicles of food poisoning. Failure to separate cooked food from raw food was also a risk factor. (6) Failure to follow food hygiene policies also provided opportunities for outbreaks of food poisoning. It included improper hygienic practices during food preparation, neglect of personnel policies (involvement of symptomatic workers in food preparation), poor results on routine inspections, and disregarding the results and recommendations of an inspection. (7) Lack of formal and in-service education, training, monitoring, and supervision of food handlers or supervisors were critical and perhaps neglected elements in occurrences of food poisoning.

  • PDF

A Study for Examples of Fire including with Combustible Substance and electrical overload in Automotive Inside Room (자동차 실내 인화성물질과 전기과부하에 의한 화재관련 사례 연구)

  • Han, Jae Oh;Ham, Sung Hoon;Lim, Ha Young;Lee, Il Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.38-43
    • /
    • 2014
  • This paper is to analyze and study the failure examples of fire by inflammables and electric contact faulty in interior of vehicle. The first example, the driver used to air freshener that remove the air conditioner bad smell. He get out of a car. And then, he put it on the crash pad. Before long, a fire breaks out because of explosion solar radiation. The second example, the driver used in room of a car. It certified the fire by disconnection phenomenon happened the electric overload. The third example, the driver install the heat rays to warm his body, In the initial stages, it didn't seek the dangerous of fire during using a car to 5,000km. This heat rays become to down durability so that produced the electric overload in an instant. The fourth example, after the man smoked the cigarette on riding with rear seat, he put it on seat in vehicle no extinguishing the burning cigarette. It knew the fact that burnt to ashes a car by on well combustible paper. Thus, the driver must consider a countermeasure for minimize the fire production when he use the inflammable and install adding electric system.

Development of the Phased Array Ultrasonic Testing Technique for Nuclear Power Plant's Small Bore Piping Socket Weld (원전 소구경 배관 소켓용접부 위상배열 초음파검사 기술 개발)

  • Yoon, Byung-Sik;Kim, Yong-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.368-375
    • /
    • 2013
  • Failure of small bore piping welds is a recurring problem at nuclear power plants. And the socket weld cracking in small bore piping has caused unplanned plant shutdowns for repair and high economic impact on the plants. Consequently, early crack detection, including the detection of manufacturing defects, is of the utmost importance. Until now, the surface inspection methods has been applied according to ASME Section XI requirements. But the ultrasonic inspection as a volumetric method is also applying to enforce the inspection requirement. However, the conventional manual ultrasonic inspection techniques are used to detect service induced fatigue cracks. And there was uncertainty on manual ultrasonic inspection because of limited access to the welds and difficulties with contact between the ultrasonic probe and the OD(outer diameter) surface of small bore piping. In this study, phased array ultrasonic inspection technique is applied to increase inspection speed and reliability. To achieve this object, the 3.5 MHz phased array ultrasonic transducer are designed and fabricated. The manually encoded scanner was also developed to enhance contact conditions and maintain constant signal quality. Additionally inspection system is configured and inspection procedure is developed.

Failure in the COG Joint Using Non-Conductive Adhesive and Polymer Bumps (감광성 고분자 범프와 NCA (Non-Conductive Adhesive)를 이용한 COG 접합에서의 불량)

  • Ahn, Kyeong-Soo;Kim, Young-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • We studied a bonding at low temperature using polymer bump and Non-Conductive Adhesive (NCA), and studied the reliability of the polymer bump/Al pad joints. The polymer bumps were formed on oxidized Si substrates by photolithography process, and the thin film metals were formed on the polymer bumps using DC magnetron sputtering. The substrate used was AL metallized glass. The polymer bump and Al metallized glass substrates were joined together at $80^{\circ}C$ under various pressure. Two NCAs were applied during joining. Thermal cycling test ($0^{\circ}C-55^{\circ}C$, cycle/30 min) was carried out up to 2000 cycles to evaluate the reliability of the joints. The bondability was evaluated by measuring the contact resistance of the joints through the four point probe method, and the joints were observed by Scanning Electron Microscope (SEM). The contact resistance of the joints was $70-90m{\Omega}$ before the reliability test. The joints of the polymer bump/Al pad were damaged by NCA filler particles under pressure above 200 MPa. After reliability test, some joints were electrically failed since thinner metal layers deposited at the edge of bumps were disconnected.

  • PDF

Design of an NMOS-Diode eFuse OTP Memory IP for CMOS Image Sensors (CMOS 이미지 센서용 NMOS-Diode eFuse OTP 설계)

  • Lee, Seung-Hoon;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.306-316
    • /
    • 2016
  • In this paper, an NMOS-diode eFuse OTP (One-Time Programmable) memory cell is proposed using a parasitic junction diode formed between a PW (P-Well), a body of an isolated NMOS (N-channel MOSFET) transistor with the small channel width, and an n+ diffusion, a source node, in a DNW (Deep N-Well) instead of an NMOS transistor with the big channel width as a program select device. Blowing of the proposed cell is done through the parasitic junction formed in the NMOS transistor in the program mode. Sensing failures of '0' data are removed because of removed contact voltage drop of a diode since a NMOS transistor is used instead of the junction diode in the read mode. In addition, a problem of being blown for a non-blown eFuse from a read current through the corresponding eFuse OTP cell is solved by limiting the read current to less than $100{\mu}A$ since a voltage is transferred to BL by using an NMOS transistor with the small channel width in the read mode.

A caving self-stabilization bearing structure of advancing cutting roof for gob-side entry retaining with hard roof stratum

  • Yang, Hongyun;Liu, Yanbao;Cao, Shugang;Pan, Ruikai;Wang, Hui;Li, Yong;Luo, Feng
    • Geomechanics and Engineering
    • /
    • v.21 no.1
    • /
    • pp.23-33
    • /
    • 2020
  • An advancing cutting roof for gob-side entry retaining with no-pillar mining under specific geological conditions is more conducive to the safe and efficient production in a coalmine. This method is being promoted for use in a large number of coalmines because it has many advantages compared to the retaining method with an artificial filling wall as the gateway side filling body. In order to observe the inner structure of the gateway cutting roof and understand its stability mechanism, an equivalent material simulation experiment for a coalmine with complex geological conditions was carried out in this study. The results show that a "self-stabilization bearing structure" equilibrium model was found after the cutting roof caving when the cut line deviation angle was unequal to zero and the cut height was greater than the mining height, and the caving roof rock was hard without damage. The model showed that its stability was mainly controlled by two key blocks. Furthermore, in order to determine the optimal parameters of the cut height and the cut line deviation angle for the cutting roof of the retaining gateway, an in-depth analysis with theoretical mechanics and mine rock mechanics of the model was performed, and the relationship between the roof balance control force and the cut height and cut line deviation angle was solved. It was found that the selection of the values of the cut height and the cut line deviation angle had to conform to a certain principle that it should not only utilize the support force provided by the coal wall and the contact surface of the two key blocks but also prevent the failure of the coal wall and the contact surface.