• Title/Summary/Keyword: contact effect

Search Result 3,294, Processing Time 0.03 seconds

The effect of jaw's curvature on Brazilian tensile strength of rocks

  • Yousefi, Halime;Fereidooni, Davood
    • Geomechanics and Engineering
    • /
    • v.23 no.2
    • /
    • pp.165-178
    • /
    • 2020
  • This paper investigates the effect of the jaw's curvature, also known by contact angle and jaw arc central angle (2α), of the Brazilian test apparatus on indirect tensile strength of various rock types. That's why, ten rock samples including limestone, marble, skarn, granite, diorite, and granodiorite were collected from some quarries in different provinces of Iran. Petrographic, mineralogical and textural investigations were performed using thin section analyses. Physical properties of the selected rock samples namely dry and saturated unit weights, porosity, water absorption, and specific gravity were determined for the rock samples. In addition, Brazilian tensile strength at different 2α angles (i.e., 2α = 0°, 10°, 15°, 20°, 45°, and 60°) were determined for the rocks in the laboratory. Results show that the parameter for the rocks is between 3.81 MPa at 2α=0° and 54.76 MPa at 2α=60°. This means that Brazilian tensile strength increased with increasing 2α angle from 0° to 60°. Also, it was found that the highest change rate of the Brazilian tensile strength occurs in range of 2α=15°-30° for most studied rock samples. In some tested samples, the parameter is decreased only at 2α = 60°. The values of Brazilian tensile strength of the rocks tested by flat and standard jaws are near to each other.

Biomechanical Comparison of Spinal Fusion Methods Using Interspinous Process Compressor and Pedicle Screw Fixation System Based on Finite Element Method

  • Choi, Jisoo;Kim, Sohee;Shin, Dong-Ah
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.2
    • /
    • pp.91-97
    • /
    • 2016
  • Objective : To investigate the biomechanical effects of a newly proposed Interspinous Process Compressor (IPC) and compare with pedicle screw fixation at surgical and adjacent levels of lumbar spine. Methods : A three dimensional finite element model of intact lumbar spine was constructed and two spinal fusion models using pedicle screw fixation system and a new type of interspinous devices, IPC, were developed. The biomechanical effects such as range of motion (ROM) and facet contact force were analyzed at surgical level (L3/4) and adjacent levels (L2/3, L4/5). In addition, the stress in adjacent intervertebral discs (D2, D4) was investigated. Results : The entire results show biomechanical parameters such as ROM, facet contact force, and stress in adjacent intervertebral discs were similar between PLIF and IPC models in all motions based on the assumption that the implants were perfectly fused with the spine. Conclusion : The newly proposed fusion device, IPC, had similar fusion effect at surgical level, and biomechanical effects at adjacent levels were also similar with those of pedicle screw fixation system. However, for clinical applications, real fusion effect between spinous process and hooks, duration of fusion, and influence on spinous process need to be investigated through clinical study.

Effect of the Hydrophobicity and the Surface Roughness of Support Material on the Microbial Attachment (담체의 소수성과 표면 거칠기가 미생물 부착에 미치는 영향)

  • Park, Young-Seek;Suh, Jung-Ho;Song, Seung-Koo
    • Journal of Environmental Science International
    • /
    • v.6 no.6
    • /
    • pp.689-696
    • /
    • 1997
  • This paper discussed effect of the surface roughness and the hydrophobicity of support material on the microbial attachment In a rotating biological contactor. The by- drophoblclty of each support material was determined by the measurement of contact angle of water and the surface roughness was measured by the surface roughness In- strument. Microorganisms have well attached on the surface of more hydrophilic support material like Nylon6 than that of the hydrophobic support material like PE. When the relatively hydrophilic surface was roughen, the microbial attachment was increased but when the relatively hydrophobic surface was roughen, the attachment was slightly In- creased because the hydrophobicity of support material was Increased by roughening the hydrophobic surface. Although both variables, the surface hydrophobicity and the surface roughness, have Influenced the microbial attachment, the influence of the surface roughness overruled that of the surface hydrophobicity. Support material whose surfaces were roughened about 1mm, 6mm and 11mm were allowed for attached 3, 7 and 24hr, but the differences of maximum and minimum attachment of each material gave nearly constant values and similar trend with time.

  • PDF

Machining Characteristics according to Electrochemical Polishing (ECP) Conditions of Stainless Steel Mesh (스테인리스 망의 전기화학 폴리싱(ECP) 조건에 따른 가공 특성)

  • Kim, Uk Su;Park, Jeong Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.41-48
    • /
    • 2015
  • Stainless steel mesh has been used as a filter in various fields, including domestic, medical, etc. However, the surface before machining may have an adverse effect the product quality and performance because it is not smooth. Especially, adsorbed impurities in the surface result in difficulty in cleaning. Therefore, in this paper, we propose an improved surface quality through electrochemical polishing (ECP). Two electrodes, composed of STS304 (anode) and copper (cathode) underwent machining with two conditions according to polishing time and current density. As the polishing time and current density increase, the surface of curvature decreases, and roughness and material removal rate (MRR) improves. The machined surface roughness and image were obtained through the atomic force microscope (AFM) and stereoscopic microscope. The study also analyzed hydrophilic effect through contact angles. This obtains corrosion resistance, smoothness, hydrophilic property, etc.

Electrical Properties of CuPC FET with Varying Substrate Temperature (CuPC PET의 기판온도에 따른 전기적 특성 연구)

  • Lee, Ho-Shik;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.1
    • /
    • pp.110-114
    • /
    • 2009
  • Organic field-effect transistors (OFETs) are of interest for use in widely area electronic applications. We fabricated a copper phthalocyanine (CuPc) based field-effect transistor with different substrate temperature. The CuPc FET device was made a top-contact type and the substrate temperature was room temperature and $150^{\circ}C$. The CuPc thickness was 40nm, and the channel length was $50{\mu}m$, channel width was 3mm. We observed a typical current-voltage (I-V) characteristics in CuPc FET.

Analysis of effect of parasitic schottky diode on sense amplifier in DDI DRAM (DDI DRAM의 감지 증폭기에서 기생 쇼트키 다이오드 영향 분석)

  • Chang, Sung-Keun;Kim, Youn-Jang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.485-490
    • /
    • 2010
  • We propose the equivalent circuit model including all parasitic components in input gate of sense amplifier of DDI DRAM with butting contact structure. We analysed the effect of parasitic schottky diode by using the proposed model in the operation of sense amplifier. The cause of single side fail and the temperature dependence of fail rate in DDI DRAM are due to creation of the parasitic schottky diode in input gate of sense amplifier. The parasitic schottky diode cause the voltage drop in input gate, and result in decreasing noise margin of sense amplifier. therefore single side fail rate increase.

Fabrication and Electrical Properties of CuPc FET with Different Substrate Temperature (CuPc FET의 기판온도에 따른 제작 및 전기적 특성 연구)

  • Lee, Ho-Shik;Yang, Seong-Ho;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.548-551
    • /
    • 2007
  • Organic field-effect transistors (OFETs) are of interest for use in widely area electronic applications. We fabricated a copper phthalocyanine (CuPc) based field-effect transistor with different substrate temperature. The CuPc FET device was made a top-contact type and the substrate temperature was room temperature and $150^{\circ}C$. The CuPc thickness was 40nm, and the channel length was $50{\mu}m$, channel width was 3mm. We observed a typical current-voltage (I-V) characteristics in CuPc FET.

  • PDF

Surface treatment of polyethylene terephthalate films by corona discharge (코로나방전에 의한 polyethylene terephthalate 필름의 표면처리)

  • 김명룡
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.316-323
    • /
    • 1995
  • A vital step in magnetic tape manufacturing is the surface modification of polymer substrate prior to ink application. A critical element for good adhesion of magnetic ink on polymeric substrate is the ability to join ink in cost-effective manner. Corona discharging is one of the effective methods of modifying polymer surface to improve adhesion while maintaining the desirable properties of the film itself. Surface treatment by corona which is exposure of film surface to electron or ion bombardment, rather than mere exposure to active species, like atomic oxygen or ozone, can enhance adhesion by removing contaminant, electret, roughening surface, and/or introducing reactive chemical groups. Reactive neutrals, ions, electron and photons generated during the corona treatment interact simultaneously with polymers to alter surface chemical composition, wettability, and thus film adhesion. However, it is highly recommended that extensive chains scission be avoided because it can lead to side-effect by forming sticky matter, resulting in dropouts. This paper reviews principles of surface preparation of polymer substrate by corona discharging. In addition, the experimental section provides a description of parameter optimization on corona discharging treatment and its side-effect. Experimental results are discussed in terms of surface wetting as determined by contact angle measurements.

  • PDF

Investigation on the P3HT-based Organic Thin Film Transistors (P3HT를 이용한 유기 박막 트랜지스터에 관한 연구)

  • Kim, Y.H.;Park, S.K.;Han, J.I.;Moon, D.G.;Kim, W.G.;Lee, C.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04b
    • /
    • pp.45-48
    • /
    • 2002
  • Poly(3-hexylthiophene) or P3HT based organic thin film transistor (OTFT) array was fabricated on flexible poly carbonate substrates and the electrical characteristics were investigated. As the gate dielectric, a dual layer structure of polyimide-$SiO_2$ was used to improve the roughness of $SiO_2$ surface and further enhancing the device performance and also source-drain electrodes were $O_2$ plasma treated for improvement of the electrical properties, such as drain current and field effect mobility. For the active layer, polymer semiconductor, P3HT layer was printed by contact-printing and spin-coating method. The electrical properties of OTFT devices printed by both methods were evaluated for the comparison. Based on the experiments, P3HT-based OTFT array with field effect mobility of 0.02~0.025 $cm^{2}/V{\cdot}s$ and current modulation (or $I_{on}/I_{off}$ ratio) of $10^{3}\sim10^{4}$ was fabricated.

  • PDF

The Effect of Physical Chemistry Factors on Formation of Disinfection by-products (소독부산물 생성에 미치는 물리화학적인 인자 영향)

  • Chung Yong;Kim Jun-Sung
    • Journal of Environmental Science International
    • /
    • v.14 no.10
    • /
    • pp.965-972
    • /
    • 2005
  • This research studied the effect of factors that are able to form disinfection by-products (DBPs) of chlorination, including natural organic matter (NOM) with sewage, bromide ions, pH and contact time. Trihalomethane (THMs) yield of $0.95{\mu}mol/mg$ was higher than other DBPs yield for the chlorinated humic acid samples. THMs yield of sewage sample was $0.14{\mu}mol/mg$ and haloacetonitriles (HANs) yield in the sewage samples were $0.13{\mu}mol/mg$ but only $0.02{\mu}mol/mg$ for the humic acid samples. As the concentration of bromide ions increased, brominated DBPs increased while chlorinated DBPs decreased, because bromide ions produce brominated DBPs. THMs were highest $(55.55{\mu}g/L)$ at a pH of 7.9 and haloacetic acids (HAAs) were highest $(34.98{\mu}g/L)$ at a pH of 5. Also THMs increased with increasing pH while HAAs decreased with increasing pH. After chlorination, the rate of THMs and HAA formation are faster at initial contact time and then reaches a nearly constant value after 24 hours. This study considers ways to reduce DBP formation by chlorination.