• Title/Summary/Keyword: contact effect

Search Result 3,294, Processing Time 0.029 seconds

Effect of water temperature and soil type on infiltration

  • Mina Torabi;Hamed Sarkardeh;S. Mohamad Mirhosseini;Mehrshad Samadi
    • Geomechanics and Engineering
    • /
    • v.32 no.4
    • /
    • pp.445-452
    • /
    • 2023
  • Temperature is one of the important factors affecting the permeability of water in the soil. In the present study, the impact of water temperature on hydraulic conductivity (k) with and without coarse aggregations by considering six types of soils was analyzed. Moreover, the effect of sand and gravel presence in the soil was investigated through the infiltration based on constant and inconstant water head experiments. Results indicated that by increasing the water temperature, adding gravel to sandy soil caused the hydraulic conductivity to raise. It is supposed that the gravel decreased the contact surface between the water and the soil aggregates. It is deduced that due to decreasing kinetic energy, k tends to have lower values. Furthermore, adding the sand to sandy silt-clay soil showed that the sand did not have a marginal effect on the variation of k since the added sand cannot increase the contact surface like gravel. Finally, increasing the main diameter of the soil will increase the effect of the water temperature on hydraulic conductivity.

Effect of Contact Position and Structure of Test Probe on Its Signal Transmission Characteristics (테스트 프로브 접점 위치와 구조의 신호 전달 특성 영향)

  • Lee, Byung-sung;Kim, Moonjung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.324-329
    • /
    • 2018
  • This study examined the effects of the contact position and structure of the test probe on its signal transmission characteristics. The contact position in the operating of the test probe was considered and then divided into the plunger inner contact and barrel inlet contact. The high frequency performance of the test probes was investigated for both contact positions. The signal transmission characteristics of the test probes with the structures of double, single, and out-spring was also analyzed. The insertion and return losses were calculated using the HFSS and the characteristic impedance of the test probes was analyzed using a Q3D simulation. The insertion loss of the barrel inlet contact was smaller than that of the plunger inner contact. The contact position of the test probe may result in a change in the high frequency performance. The out-spring probe has better frequency characteristics at -1 dB insertion loss and -10 dB return loss. The double probe and single probe have the same characteristic impedance with $30.8{\Omega}$. On the other hand, the out-spring probe has an impedance of $47.1{\Omega}$. The out-spring probe is closer to $50{\Omega}$ than the other probes and then shows higher signal transmission characteristics. The out-spring probe has superior high-frequency characteristics and is expected to be suitable for high-speed applications.

Bleaching Observation of Cosmetic Color Lenses According to Multipurpose Contact Lens Solutions (다목적 콘택트렌즈 용액에 대한 미용 칼라렌즈의 탈색 관찰)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.295-303
    • /
    • 2014
  • Purpose: This study aims to observe bleaching resulted from multipurpose contact lens solutions used to manage lenses with the subjects of colored contact lenses being distributed in Korea. Methods: The lenses have been worn for six months, and their refraction is 0.00D. Three types of colored contact lenses of which margin has been colored with a different manufacturing method have been adopted (type 1: pigment application method, type 2: chemical bonding process, type 3: sandwich method), and multipurpose solutions used were two types containing different components. Each of the colored contact lenses was stored in the multipurpose solutions for 20 days and went through vortexing for 15 seconds per day. Their fluorescence absorbance, surface roughness, brightness index, and color coordinate index were measured before and after the vortexing to see the degree of bleaching. Results: In the two types of multipurpose solutions, every type of the color contact lenses showed no statistically significant difference in their fluorescence absorbance value before and after the vortexing. Regarding surface image, the front surface of the lenses was smooth in every type, and about the back surface, type 3 indicated less protrusion than type 1 and 2. About the difference of color on the lens surface before and after the vortexing, type 3 showed significantly less difference than type 1 and 2; however, all fell into the permissible error. Conclusions: About the bleaching of colored contact lenses resulted from multipurpose solutions for soft contact lenses, there was no difference observed in terms of fluorescence absorbance and color. According to the methods of manufacturing dyes, however, there was difference in the protrusion of the posterior surface image.

Effects of Chogam-Tang on Rat Skin Induced the Allergic Contact Dermatitis (백서(白鼠)에 유도된 알러지성 피부염에 대한 초감탕(椒甘湯)의 효과)

  • Yoon, Hui-Sung;Park, Owe-Suk;Kim, Hee-Jeong;Kim, Keoo-Seok;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.18 no.3
    • /
    • pp.44-54
    • /
    • 2005
  • Background and Objectives: Allergic contact dermatitis is a common environmental health issue and seriously affect the patient's quality of life. The more our environment industrialized, the number of material that could cause the allergic contact dermatitis has been increased, consequently the prevalence of allergic contact dermatitis has been increased. In oriental medicine, clinically Chogam-Tang has been used fur the treatment of allergic dermatitis, eczema, atopic dermatitis etc. The objective of this study is to investigate the effects of Chogam-Tang on allergic contact dermatitis Meterial and Methods: Fifteen Sprague-Dawley rats were divided into three groups: normal, control, experimental group. Control and experimental group were induced allergic contact dermatitis, by DNCB. Experimental group was orally administered the Chogam-Tang. Each group was observed after 24, 48 and 72 hours. Contact hypersensitivity assay, melanin-erythema measurement, pH measurement skin moisture measurement and biopsy were performed. Results: 1. In contact hypersensitivity assay, experimental group showed decreased ear swelling compared with control group at 48hours. 2. ln melanin measurement there was no difference in three groups. 3. In erythema measurement experimental group showed reduction at 48. 72 hours. 4. In pH measurement, experimental group and control group showed increase in pH but there was no statistical significance. 5. In skin moisture measurement, experimental group showed higher skin moisture level than control group at 24 hours and showed lower skin moisture level at 72 hours, but there was no statistical significance. 6. In biopsy, experimental group showed decrement of Iymphocyte as time goes by, and regeneration of keratin layer was increased compared with normal group. Conclusions: Chogam-Tang shows anti-inflammatory effect in biopsy, improves hydration levels of skin, decreases erythema level on allergic contact dermatitis.

  • PDF

The Effect of Eye Contact on User Experience in Synchronous Online Communication (실시간 온라인 커뮤니케이션에서 눈 맞춤이 사용자 경험에 미치는 영향)

  • Shin, Hyorim;Lee, Soyeon;Choi, Junho
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.8
    • /
    • pp.20-31
    • /
    • 2021
  • The spread of non-face-to-face culture due to COVID-19 led to innovation in untact services and the increase of non-face-to-face communication through video conference platforms. However, it is difficult to identify nonverbal expressions in synchronous online communication. Moreover, it is hard to interact with people by making eye contact. Despite the positive effects of eye contact, including such as sharing emotions and helping build intimacy, no research has empirically verified the effectiveness of eye contact in synchronous online communication. Thus, the study verified the effectiveness of eye contact in synchronous online communication. Depending on the context of the communication and whether(or not) there is eye contact, six video treatments were used to measure four dependent variables-Continuance Intention to Use, Performance Expectancy, Interactivity, and Personal Connection. The study shows that the communication with eye contact in all contexts was rated higher than the one without eye contact in all measurement variables. This study will help to provide a better user experience in synchronous online communication by verifying the effectiveness of eye contact in synchronous online communication and proposing the need of technology and the direction of the technological development.

Effects of Low Pressure and Atmospheric Pressure Plasma Treatment on Contact Angle of Polycarbonate Surface (저압 및 대기압 플라즈마 처리를 통한 폴리카보네이트의 접촉각 변화특성 비교)

  • Won, Dong Su;Kim, Tae Kyung;Lee, Won Gyu
    • Applied Chemistry for Engineering
    • /
    • v.21 no.1
    • /
    • pp.98-103
    • /
    • 2010
  • The effect of plasma treatment on surface characteristics of polycarbonate (PC) films was investigated using low pressure plasma and atmospheric pressure plasma with oxygen and argon. Untreated PC has a contact angle of $82.31^{\circ}$ with de-ionized water which reduced to $9.17^{\circ}$ as the lowest value after being treated with a low pressure plasma treatment with oxygen. Increase of delivered powers such as RF and AC with a high frequency and gas flow rates was not effective to reduce contact angles dramatically but gave the trend of reducing gradually. The surface of PC treated with plasma shows a low contact angle but the contact angle increases rapidly according to the exposure time in air ambient. Oxygen plasma was more effective to generate the polar functional group regardless of the type of plasma. Conclusively, a low plasma treatment with oxygen is more recommendable when the hydrophilic surface of PC is required.

Nano/Micro Friction with the Contact Area (접촉 면적에 따른 나노/마이크로 마찰 특성)

  • Yoon Eui-Sung;Singh R. Arvind;Kong Hosung
    • Tribology and Lubricants
    • /
    • v.21 no.5
    • /
    • pp.209-215
    • /
    • 2005
  • Nano/micro friction with the contact area was studied on Si-wafer (100) and diamond-like carbon (DLC) film. Borosilicate balls of radii $0.32{\mu}m,\;0.5{\mu}m,\;1.25{\mu}m\;and\;2.5{\mu}m$ mounted on the top of AFM tip (NPS) were used for nano-scale contact and Soda Lime glass balls of radii 0.25mm, 0.5mm, 1mm were used for micro-scale contact. At nano-scale, the friction between ball and surface was measured with the applied normal load using an atomic force microscope (AFM), and at micro scale it was measured using ball-on flat type micro-tribotester. All the experiments were conducted at controlled conditions of temperature $(24\pm1^{\circ}C)$ and humidity $(45\pm5\%)$. Friction was measured as a function of applied normal load in the range of 0-160nN at nano scale and in the range of $1000{\mu}N,\; 1500{\mu}N,\;3000{\mu}N\;and\;4800{\mu}N$ at micro scale. Results showed that the friction at nano scale increased with the applied normal load and ball size for both kinds of samples. Similar behavior of friction with the applied normal load and ball size was observed for Si-wafer at micro scale. However, for DLC friction decreased with the ball size. This difference of in behavior of friction in DLC nano- and microscale was attribute to the difference in the operating mechanisms. The evidence of the operating mechanisms at micro-scale were observed using scanning electron microscope (SEM). At micro-scale, solid-solid adhesion was dominant in Silicon-wafer, while plowing in DLC. Contrary to the nano scale that shows almost a wear-less situation, wear was prominent at micro-scale. At nano- and micro-scale, effect of contact area on the friction was discussed with the different applied normal load and ball size.

Disinfection of E. coli from Wastewater using a Non-contact type UV Photoreactor and Log Inactivation Index (비접촉식 자외선 광반응조를 이용한 하수 대장균의 살균과 Log 불활성화율 지표)

  • Kim, Sunghong;Kim, Kyungmyun;Kim, Gwangil;Choe, Jaewan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.139-145
    • /
    • 2016
  • Disinfection of microorganisms using UV light is widely used in the field of water supply and wastewater treatment plant, In spite of high germicidal effect and relatively clean by-product, UV disinfection has fundamental defeat that is accumulation of fouling materials at the interface of water and lamp sleeve. Non-contact type of UV photoreactor which can avoid this fouling generation was developed and the experimental performance evaluation of the system was carried out in this study. Log inactivation rate of E. coli was selected as a disinfection index. The concentration of E. coli of second clarifier effluent was $8.2{\times}10^1-8.2{\times}10^3$ colony per mL and was well inactivated by the non-contact type of UV photoreactor. Under the UV intensity condition of $2.1-2.5mW/cm^2$, E. coli removal rate was observed in the range of 54 - 95% when the HRT was increased from 10 to 52 seconds. Experimental results showed that log inactivation of E. coli was proportional to UV dosage and $200mJ/cm^2$ of UV dose is expected for the 2.0 log inactivation of E. coli from the second clarifier effluent. Between the two parameters of UV intensity and contact time which are consist of UV dose, UV intensity was 4 times more effective than contact time.

Prediction of Surface Crack Growth Considering the Wheel Load Increment Due to Rail Defect (레일손상에 의한 윤중증가를 고려한 표면균열 성장예측)

  • Jun, Hyun-Kyu;Choi, Jin-Yu;Na, Sung-Hoon;You, Won-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.9
    • /
    • pp.1078-1085
    • /
    • 2011
  • Prediction of a minimum crack size for growth, which is defined as a crack size that grows fast enough to keep ahead of its removal by contact wear and periodic grinding, is the most demanding work to prevent rail from fatigue failure and develop cost effective railway maintenance strategy In this study, we investigated the wheel load increment due to a rail defect during a train ran over it, and its effect on the minimum crack size for growth. For this purpose, we developed simulation software based on the Fletcher and Kapoor's "2.5D" model and measured wheel load increment during a train passed over a defect. A maximum contact pressure and contact patch size were calculated by 3D FEM and crack growth analyses were performed by varying two of dominant contact contributors; surface friction coefficient(0.1, 0.2, 0.3 and 0.4) and crack aspect ratio. The minimum crack sizes for growth were calculated from 0.29 to 1.44mm depending on the contact conditions. They were decreasing with increasing surface friction coefficient and decreasing with crack aspect ratio(a/b).

A Study on the Effects of Maximum Voluntary Clenching on the Tooth Contact Points and Masticatory Muscle Activities in Patients with Temporomandibular Disorders (측두하악장애환자에 있어서 수의적 악물기시의 치아접촉점 및 저작근 활성에 관한 연구)

  • Jae-Kap Choi;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.15 no.1
    • /
    • pp.105-115
    • /
    • 1991
  • The purpose of the study was to evaluate the occlusal stability at the moment of dynamic occlusal tooth contact and to investigate the correlation between the occlusal stability and the masticatory muscle activities. It also evaluated the effect of short-term use of occlusal splints on the occlusal stability and the masticatory muscle activities in patients with temporomandibular disorders during maximum voluntary clenching by synchondronized with temporomandibular disorders during maximum voluntary clenching by synchronized use of the T-Scan system(Tekscan, Inc, USA) and K6-Diagnostic system(Myo-tronics Research, Inc, USA) The author measured its distance from retruded contact position(RCP) to intercuspal position(IP), average of contact intervals(ACI), total left-right statistics(TLR), average muscle activities of masseter and anterior temporal muscles during maximum voluntary clenching in 20 patients with temporomandibular disorders and 22 dental students as a control group. The data were compared between two groups and investigated for any correlations between the parameters. The results were as follows : 1. Both of the mean average of contact intervals and the mean absolute value of total left-right statistics during maximum voluntary clenching were increased in the patient group when compared with the control group. 2. Muscular disharmony of anterior temporal muscles of patient group is significantly greater than that of control group. However, muscular disharmony of masseter muscles of patient group is not significantly greater than that of control group. 3. There were significant correlations between muscular disharmony of anterior temporal muscles and average of contact intervals as well as total left-right statistics, and also between muscular disharmony of masseter muscles and total left-right statistics. 4. There were not any significant correlations between distance from RCP to IP and any other parameters. 5. There were a significant decrease in total left-right statistics and muscular disharmony of anterior temporal muscles during maximum voluntary clenching after a 1week use of occlusal splint in the patient group.

  • PDF