• Title/Summary/Keyword: contact effect

Search Result 3,294, Processing Time 0.034 seconds

Effect of Sopung-san on Contact Hypersensitivity induced by Repeat Elicitation of DNCB (소풍산물추출물이 DNCB로 유발된 접촉성피부염에 미치는 영향)

  • Park, Sook-Jahr;Lee, Sang-Gon;Baek, Jung-Han;Byun, Sung-Hui;Kim, Sang-Chan
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.3
    • /
    • pp.623-628
    • /
    • 2006
  • Sopung-san(SPS; prescription No. DO27), a herbal medicine prescribed by oriental hospital of Daegu fanny University, has been used as cure for pruritus and psoriasis. To evaluate anti-inflammatory effect of Sopung-san, we treated Sopung-san extract in animal model system induced contact hypersensitivity. Contact hypersensitivity, a local inflammatory response of the skin, was induced by 1% DNCB on the right ear of BALB/C mouse. Sopung-san was prepared as water extract and administrated everyday for 2 weeks per oral. A right ear of mouse was potently swelled by 1% of DNCB treatment, but a mouse ear thickness was significantly reduced by Sopung-san after 2 weeks. treatment. Sopung-san reduced IgG in serum obtained from blood of 1 % DNCB-treated mouse. IgE in serum was not changed by DNCB and/or Sopung-san treatment. $IL-1{\beta}$ and IL-6 from ear tissue were significantly increased by DNCB, Dut were not reduced by Sopung-san. From these results, anti-inflammatory effect of Sopung-san, especially reduction of ear swelling, might be partly due to reduction of IgG in serum.

The effect of ambiguity of information on Covid-19 patients' contact trace on intention to visit the commercial district: Comparison of residents in Gangnam-gu and Seocho-gu (코로나19 확진자 동선정보의 모호성 차이가 유관 상권 방문의도에 미치는 영향 연구: 강남구민과 서초구민의 비교)

  • Min, Dongwon
    • Journal of Digital Convergence
    • /
    • v.18 no.8
    • /
    • pp.179-184
    • /
    • 2020
  • This study aims to investigate the effect that local government's information release range on Covid-19 patients' contact trace on consumer sentiment in the region. One hundred twenty-eight residents of Gangnam-gu and Seocho-gu participated in the study. The results showed that when ambiguity of information increased perceived anxiety on Covid-19 patients' contact trace, which in turn led lower intention to visit the commercial district near the Covid-19 patients' contact trace. Based on the findings, several suggestions was proposed for future research, including longitudinal studies covering even the "long-term" changes in consumer sentiment, the effect of implicit anxiety, and the behavioral difference between residence and non-residence.

Kinetic study about the effect of electric field and contact time of high voltage impulse on reduction of Ca2+ concentration (고전압 임펄스 공정의 전계와 접촉시간이 Ca2+ 농도 저감에 미치는 영향의 속도론 연구)

  • Kim, Dam-Ha;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.2
    • /
    • pp.113-120
    • /
    • 2021
  • High voltage impulse (HVI) has been gained attention as an alternative technique that could control the CaCO3 scale problems encountered in water main, pipe, cooling tower and heat exchanger vessels. The aim of this study was to investigate the effect of electric field (E) and contact time (t) of HVI on reduction of Ca2+ concentration at two different temperatures of 25℃ and 60℃. A kinetic model on the effect of E and t was investigated too. As the E and t increased, the Ca2+ concentration decreased more than that of the control (= no HVI). The Ca2+ concentration decreased up to 81% at 15 kV/cm at 60℃, which was nearly 2 times greater than the control. With these experimental data-set of reduction of Ca2+ concentration under different E and t, the kinetic model was developed. The relationship between E and t required to reduce the concentration of Ca2+ by 30% was modeled at each temperature. The empirical model equations were; E0.83· t = 60.3 at 25℃ and E0.08· t = 1.1 at 60℃. These equations state the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increment of E and vice versa.

Effect of MoSe2 on Contact Resistance of ZnO/Mo Junction in Cu(In,Ga)Se2 Thin Film Solar Module (MoSe2가 Cu(In,Ga)Se2 박막 태양전지 모듈의 ZnO/Mo 접합의 접촉 저항에 미치는 영향)

  • Cho, Sung Wook;Kim, A Hyun;Lee, Gyeong A;Jeon, Chan Wook
    • Current Photovoltaic Research
    • /
    • v.8 no.3
    • /
    • pp.102-106
    • /
    • 2020
  • In this paper, the effect of MoSe2 on the contact resistance (RC) of the transparent conducting oxide (TCO) and Mo junction in the scribed P2 region of the Cu(In,Ga)Se2 (CIGS) solar module was analyzed. The CIGS/Mo junction becomes ohmic-contact by MoSe2, so the formation of the MoSe2 layer is essential. However, the CIGS solar module has a TCO/MoSe2/Mo junction in the P2 region due to structural differences from the cell. The contact resistance (RC) of the P2 region was calculated using the transmission line method, and MoSe2 was confirmed to increase RC of the TCO/Mo junction. B doped ZnO (BZO) was used as TCO, and when BZO/MoSe2 junction was formed, conduction band offset (CBO) of 0.6 eV was generated due to the difference in their electron affinities. It is expected that this CBO acts as a carrier transport barrier that disturbs the flow of current, resulting in increased RC. In order to reduce the RC caused by CBO, MoSe2 must be made thin in a CIGS solar module.

Human Skin Safety Test of Green Tea Cell Extracts in Condition of Allergic Contact Dermatitis

  • Kim, Hyun-Kyu;Choi, Sun-Young;Chang, Hui-Kyoung;Baek, Seok-Yun;Chung, Jin-Oh;Rha, Chan-Su;Kim, Beom-Joon;Kim, Myeung-Nam
    • Toxicological Research
    • /
    • v.28 no.2
    • /
    • pp.113-116
    • /
    • 2012
  • Various kinds of positive effects of green tea extracts had been studied for long time which included anti-inflammation, anti-aging, and cardiometabolic effects. Although topical steroid and non-steroidal calcineurin inhibitors may control clinical symptoms of allergic contact dermatitis, some of patients also present allergic reaction to these topical agents. Therefore, we have tried green tea extracts for managing this skin disorder with expectation of anti-inflammatory effect without potential side effects including skin irritation and toxic responses. The toxicity test of green tea extract also did not show any sign of irritation in the skin throughout the test period. Moderate severity of allergic contact dermatitis presented satisfactory clinical outcome at second week follow-up which was final visit of outpatient. This result mean that green tea extract has a positive effect for managing allergic contact dermatitis but its potency and efficacy seem to be so not strong enough to control moderate severity allergy skin lesion. In this pilot study, we were able to conclude that green tea cell extracts might be applied for potential anti-inflammatory soaking without skin toxicity.

A Study of the Influence of Strain Gauge Location and Contact Conditions by Loading Platens on the Mechanical Behavior of Rock Specimens (암석공시체의 역학적 거동 해석에 미치는 변형율게이지 위치 및 단면구속 영향에 대한 연구)

  • 정교철
    • The Journal of Engineering Geology
    • /
    • v.8 no.3
    • /
    • pp.215-224
    • /
    • 1998
  • In this study, total strain was measured by LVDTs and local strains on the surface of specimens were measured by strain gauges. And axi-symmetrically elastoplastic FEM analyses was carried out for cylindrical specimens. Considering the influence of the restraint induced by the loading platen, in the case of H/D=1, the strain distribution on the side of a specimen is obviously affected by the condition of platen contact. Furthermore, it is clear that the larger H/D ratio becomes, the smaller the influence to the strain distribution is. For the smooth contact condition, the strain on the side is not influenced by the stiffness of the specimen, the shape and the scale effect, the strain distribution coincides with the nominal total strain. Whereas, in the case of rough contact condition, the strain distribution is remarkably affected. It is made clear that strain responses of hard rock specimens may more sensitive than these of soft rock specimens as a results of interaction between loading platens and specimen and the uniaxial strength of specimens may strongly depends on this interaction and stress-strain relation is affected by the contact condition.

  • PDF

A Study of Ultrastructure on attachment of Soft Contact Lens Surface of Incubated Pseudomonas aeruginosa (배양된 Pseudomonas aeruginosa의 소프트 콘택트 렌즈 표면부착에 대한 미세구조적 연구)

  • Kim, Douk Hoon;Park, Yong Tae;You, Hae Byung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.11-14
    • /
    • 2000
  • The soft contact lens was very simple technique in handling, good sensation in fitting, good effect of a beauty, and good attachment state on the cornea in physical movement. So that, the subjects have used the correct of visual acuity. If the contact lens handling have not skill, they have acquired the side effect on eye. To analysis of a study of ultrastructure on soft contact lens surface of incubated P. aeruginosa. We have observed the soft contact lens surface by SEM. We have founded the good technical method. On the method of sample process of manufacture, the best observation of samlpe tissue was $OsO_4$ postfixation and tannic acid treatment. In this case, P. aeruginosa was a rod shape and one cilia in ultrastructure and the identification was very good. But, On the process of manufacture have not used the $OsO_4$ and tannic acid treatment, this tissue sample appeared the foreign body materials and artifacts, and the identification of the P. aeruginosa was very difficult.

  • PDF

Effect of Hydrophobic Condition and Water Content on the Spectral Information of Soil Particle Surface (흙 입자 표면의 소수성 조건과 함수비가 분광정보에 미치는 영향)

  • Jeong-Jun, Park;Seung-Kyong, You;Kwang-Wu, Lee;Jung-Mann, Yun;Gigwon, Hong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.4
    • /
    • pp.93-100
    • /
    • 2022
  • This study describes the evaluation results on the effect of soil particle surfaces coated with various hydrophobic conditions on spectral information according to water content. Wettability test and spectral information evaluation test were performed on the hydrophobic coated standard sand. When the standard sand was coated with 1%, 3%, and 5% hydrophobic, the contact angles of sand-water interface were 130°~143°, 129°~144°, and 131°~144°, respectively. This means that the contact angle increased as the degree of hydrophobic coating increased at the same drying time, but the range of the contact angle had the same wettability. This means that the contact angle increases as the hydrophobic coating degree increases at the same drying time, whereas the contact angle range has the same wettability. As a result of spectral information evaluation, the maximum spectral reflectance of the dried sand with hydrophobic condition decreased compared to that of the hydrophilic sand, as the degree of hydrophobic increased. However, the maximum spectral reflectance was increased by increasing the degree of hydrophobic under the same water content conditions.

Study on vibration energy characteristics of vehicle-track-viaduct coupling system considering partial contact loss beneath track slab

  • Liu, Linya;Zuo, Zhiyuan;Zhou, Qinyue;Qin, Jialiang;Liu, Quanmin
    • Structural Engineering and Mechanics
    • /
    • v.75 no.4
    • /
    • pp.497-506
    • /
    • 2020
  • CA mortar layer disengagement will give rise to the overall structural changes of the track and variation in the vibration form of the ballastless track. By establishing a vehicle-track-viaduct coupling analysis and calculation model, it is possible to analyze the CRTS-I type track structure vibration response while the track slab is disengaging with the power flow evaluation method, to compare the two disengaging types, namely partial contact loss at one edge beneath track slab and partial contact loss at midpoint beneath track slab. It can also study how the length of disengaging influences the track structures vibration power. It is showed that when the partial contact loss beneath track slab, and the relative vibration energy level between the rail and the track slab increases significantly within [10, 200]Hz with the same disengaging length, the partial contact loss at one edge beneath track slab has more prominent influence on the vibration power than the partial contact loss at midpoint beneath track slab. With the increase of disengaging length, the relative vibration energy level of the track slab grows sharply, but it will change significantly when it reaches 1.56 m. Little effect will be caused by the relative vibration energy level of the viaduct. The partial contact loss beneath the track slab will cause more power distribution and transmission between the trail and track slab, and will then affect the service life of the rail and track slab.

The Research of Ni/Cu/Ag Contact Solar Cells for Low Cost & High Efficiency in Crystalline Solar Cells (결정질 실리콘 태양전지의 저가 고 효율화를 위한 Ni/Cu/Ag 전극 태양전지)

  • Cho, Kyeong-Yeon;Lee, Ji-Hun;Lee, Soo-Hong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.214-219
    • /
    • 2009
  • In high-efficiency crystalline silicon solar cells, If high-efficiency solar cells are to be commercialized. It is need to develop superior contact formation method and material that can be inexpensive and simple without degradation of the solar cells ability. For reason of plated metallic contact is not only high metallic purity but also inexpensive manufacture. It is available to apply mass production. Especially, Nickel, Copper and Silver are applied widely in various electronic manufactures as easily formation is available by plating. The metallic contact system of silicon solar cell must have several properties, such as low contact resistance, easy application and good adhesion. Ni is shown to be a suitable barrier to Cu diffusion as well as desirable contact metal to silicon. Nickel monosilicide(NiSi) has been suggested as a suitable silicide due to its lower resistivity, lower sintering temperature and lower layer stress than $TiSi_2$. Copper and Silver can be plated by electro & light-induced plating method. Light-induced plating makes use the photovoltaic effect of solar cell to deposite the metal on the front contact. The cell is immersed into the electrolytic plating bath and irradiated at the front side by light source, which leads to a current density in the front side grid. Electroless plated Ni/ Electro&light-induced plated Cu/ Light-induced plated Ag contact solar cells result in an energy conversion efficiency of 14.68 % on $0.2{\sim}0.6{\Omega}{\cdot}cm,\;20{\times}20mm^2$, CZ(Czochralski) wafer.

  • PDF