• Title/Summary/Keyword: contact effect

Search Result 3,294, Processing Time 0.037 seconds

Enhancement of insecticidal efficacy of acetamiprid soluble concentrates using different adjuvants (서로 다른 보조제에 의한 acetamiprid 액제의 살충활성 증진효과)

  • Kim, Hyeong-Min;Lee, Weon-Kee;Kim, Jong-Kwan;Lee, Chang-Hyuk;Yu, Yong-Man;Hwang, In-Cheon
    • The Korean Journal of Pesticide Science
    • /
    • v.8 no.4
    • /
    • pp.325-331
    • /
    • 2004
  • The studies were undertaken to establish optimum formulation recipes of acetamipid 4% SL(soluble concentrate) using different adjuvants and to evaluate enhanced control effect on target insect pests by adjuvants. Adjuvants for the studies used were SS(Sodium alkylcarboxylate) and PE(Polyoxyethylene alkyl ether). After the fundamental recipe for SL being established by using co-solvent for stability at low temperature, four types of SL were formulated. The physical properties and insecticidal efficacies of the tested SL formulations were investigated. Surface tension of SL1 without adjuvant was highly decreased from 44 dyne/cm to 34 dyne/cm by addition of adjuvants. SL4 using mixed adjuvant showed the lowest contact angle. Efficacies of SL1 without adjuvant against the palm thrips (Thrips palmi) and the cotton aphid (Aphis gossypii) on cucumber were increased by adding adjuvants. SL4 using mixed adjuvant showed higher efficacy than SL2 and SL3 using single adjuvant. These results have demonstrated that the selected adjuvants could be used to enhance insecticide efficacy and reduce spray dose of insecticide.

Effects of Sm:Ba:Cu Composition Ratio on the Superconducting Properties of SmBCO Coated Conductor Prepared by using a Composition Gradient Method (SmBCO 초전도 선재 특성에 대한 Sm:Ba:Cu 조성비의 영향)

  • Kim, H.S.;Oh, S.S.;Jang, S.H.;Min, C.H.;Ha, H.S.;Ha, D.W.;Ko, R.K.;Youm, D.J.;Moon, S.H.;Chung, K.C.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.7-11
    • /
    • 2011
  • The effects of Sm:Ba:Cu composition ratio in SmBCO coated conductor on their superconducting properties were investigated. The SmBCO coated conductors were fabricated by reactive co-evaporation method using EDDC(Evaporation using Drum in Dual Chamber) system. In this system, we could obtain various samples with different composition ratios in a batch by the technique providing composition gradient at deposition zone. From the specimens prepared by EDDC system, we found that composition ratio is uniform parallel to the drum axis, but gradient along the circumferential direction of the drum. We installed a shield having parallelogram open area between the deposition chamber and the evaporation chamber in EDDC system, and attached a 30 cm long template, which is parallel to drum axis, onto the drum surface. In this configuration, we could obtain SmBCO coated conductors having a gradient composition along the length of template. We measured the composition ratios and surface morphologies with periodic interval by SEM and EDAX, and confirmed the profile of composition ratio. We also measured critical current using non-contact Hall probe critical current measurement system and thereby could plot composition ratio vs. critical current. The maximum critical current was obtained, and the surface morphology with the shape of roof tile was observed at the corresponding composition ratio of Sm:Ba:Cu = 1.01:1.99:4.87. It was also found that composition ratio had an effect on not only critical current but also surface morphology.

Investigation of Friction and Wear Characteristics of Cast Iron Material Under Various Conditions (다양한 조건에 따른 주철 소재의 마찰/마모 특성에 관한 연구)

  • Joo, Ji-Hoon;Kim, Chang-Lae;Nemati, Narguess;Oh, Jeong-Taek;Kim, Dae-Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.8
    • /
    • pp.765-772
    • /
    • 2015
  • Cast iron is widely used in fields such as the transport and heavy industries. For parts where contact damage is expected to occur, it is necessary to understand the friction and wear characteristics of cast iron. In this study, we use cast iron plates as the specimens to investigate their friction and wear characteristics. We perform various experiments using a reciprocating type tribotester. We assess the frictional characteristics by analyzing the friction coefficient values that were obtained during the sliding tests. We observe the wear surfaces of cast iron and steel balls using a scanning electron microscope, confocal microscope, and 3d profiler. We investigate the friction and wear characteristics of cast iron by injecting sand and alumina particles having various sizes. Furthermore, we estimate the effect of temperature on the friction and wear characteristics. The results obtained are expected to aid in the understanding of the tribological characteristics of cast iron in industry.

Operating Report of a Hospice Cyber Counselling Program (호스피스 사이버상담 프로그램 운영에 대한 소고)

  • Yoo, Ji-Soo;Lee, Yoon-Jeoung;Kang, Se-Won
    • Journal of Hospice and Palliative Care
    • /
    • v.9 no.1
    • /
    • pp.30-34
    • /
    • 2006
  • Purpose: This study is to report the operating result of the Hospice Cyber Counselling Program for improving quality of lift for terminal patients and their families. Methods: This study was performed followed by counsellor training, building strategy of public relations, management, and evaluation of the effect in order. Results: 72 subjects visited our cyber homepage and became members for approximately 9 months from Oct. 2004 to July 2005; 17 subjects in their 20s (23.6%), 12 subjects in their 30s (16.7%), 17 subjects in their 40s (23.6%), and 13 subjects above 50s (18%). Classified by diagnose related group, cancer related disease consist of 90%. As for the relationship between contents of counselling and counselling applicants, families consist of 90% and self-applicants only 10%. Only 30 members used on-line counselling and their counselling frequency was just 35 times. Although counselling frequency and the number of members who used the counselling site were not high, they tend to contact with a counsellor continuously and use the site actively after the first counselling. Conclusion: Cyber counselling program for hospice was practically managed to improve quality of life for terminal patients and their families as a basic activity for hospice business activation. Basic public relations with regard to hospice business by mass media and the press should be performed continuously and the hospice training program is required for medical personnel to be continue.

  • PDF

Sliding Wear Properties of Graphite as Sealing Materials for Cut off Hot Gas (고온차단 기밀용 그라파이트의 고온 미끄럼마모 특성 평가)

  • Kim, YeonWook;Kim, JaeHoon;Yang, HoYeong;Park, SungHan;Lee, HwanKyu;Kim, BumKeun;Lee, SeungBum;Kwak, JaeSu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1349-1354
    • /
    • 2013
  • Sealing structure to prevent flowing hot gas into the driving device, located between the driving shaft and the liner of On-Off valve for controlling the hot gas flow path was studied. Wear occurs due to the constant movement of the driving shaft controlled by actuator on graphite as the sealing material. In this paper, the dynamic wear behavior in high temperature of graphite(HK-6) to be used as sealing material was evaluated. Reciprocating wear test was carried out for the graphite(HK-6) to the relative motion between shaft materials(W-25Re). The results of friction coefficient and specific wear rate according to contact load, sliding speed at room temperature and $485^{\circ}C$ considering the actual operating environment were evaluated. Through the SEM analysis of the worn surface, third body as lubricant films were observed and lubricant effect of third body was considered.

A Study on the Microstructure and Adhesion Properties of Sn-3.5Ag/Alloy42 Lead-Frame Solder Joint (Sn-3.5Ag/Alloy42 리드프레임 땜납접합의 미세조직과 접합특성에 관한 연구)

  • Kim, Si-Jung;Bae, Gyu-Sik
    • Korean Journal of Materials Research
    • /
    • v.9 no.9
    • /
    • pp.926-931
    • /
    • 1999
  • The microstructure, wettability, shear strength and aging effect of Sn-3.5Ag/Cu and Alloy42 lead-frame solder joints were measured for comparison. In the case of Sn-3.5Ag/Cu, $Ag_3Sn and Cu_6Sn_5$ phases in the matrix Sn and $1~2\mu\textrm{m}$ thick $Cu_6Sn_5$ phase at the interface of solder/lead-frame were formed. In the case of Sn-3.5Agl Alloy42, only AgJSn phase of low density in the matrix Sn and $0.5~1.5\mu\textrm{m}$ thick $FeSn_2$, phase at the interface of solder/leadframe were formed. Comparing to Cu, Alloy42 showed wider area of spread and smaller contact angle, thus better wet­tability. But shear strength and ductility of Alloy 42 solder joints were only 33% and 75% of those of Cu, respectively After aging at $180^{\circ}C$ for 1 week, $\xi-Cu_3Sn$ layer on $\eta-Cu_6Sn_5$ layer was formed on Cu lead-frame, while coarsened cir­cular $Ag_3Sn$ phase in the matrix and thickened $FeSn_2$, at the interface were formed on Alloy42 lead- frame.

  • PDF

A Comparison of Laser Flash and the Divided-bar Methods of Measuring Thermal Conductivity of Rocks (암석 열전도도 측정을 위한 Laser Flash Method와 Divided-bar Method 비교)

  • Oh, Jae-Ho;Kim, Hyoung-Chan;Park, Jeong-Min
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.387-397
    • /
    • 2011
  • In this study, we conducted the study of the merits and demerits of the laser flash and the divided-bar methods for measuring the thermal conductivity of rocks and investigated applicability of the divided-bar apparatus which was developed by KIGAM. The laser flash method can measure thermal diffusivity, specific heat capacity, and thermal conductivity of rocks with even small thickness (< ~3 mm) in the high temperature range($25-200^{\circ}C$) in non-contact mode. For the laser flash method, samples must be uniform and homogeneous. In the case of the divided-bar method, the apparatus measures only thermal conductivity of rock samples at the room temperature. We measured thermal conductivities of 12 rock samples with low density and high porosity using two methods. In the laser flash method, there exist potential errors caused by the effect of pulse dispersion and reflection by various minerals and porosity in rock samples; the difference in thermal conductivity values measured on the front surface and the opposite surface ranges from 0.001 to 0.140 W/mK with the standard deviation of 0.003~0.089 W/mK, which seems to be caused by heterogeneity of rock samples. On the contrary, the divided-bar apparatus shows stable thermal conductivity measurements and relatively small measurement errors; the difference in thermal conductivity values, just as we applied to the laser frash method, is 0.001~0.016 W/mK with the standard deviation 0.001~0.034 W/mK. In turn, the divided-bar method can be applied to more thick samples that are more representative of bulk thermal conductivity.

Knowledge on the chemical disinfectants among dental workers in some Daejeon region (대전 일부 지역 치과종사자의 화학소독제에 관한 지식도 연구)

  • Min, Hee-Hong;Ahn, Kwon-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.4
    • /
    • pp.455-470
    • /
    • 2007
  • The usage of appropriate disinfectants is essential for infection control in dental hospitals, dental clinics. Inadequate use of disinfectants is the cause of human or environmental toxicity and is a waste of cost. This study was aimed to assess the level of knowledge on the disinfection and chemical disinfectants among dental workers in dental hospitals, dental clinics. It's ultimately intended to serve as a basis for the preparation of more effective, appropriate educational programs on the disinfection and manuals on the use of disinfectants for dental workers. This study enforced a questionnaire with 184 dental workers employed in dental hospitals, dental clinics from 15 Aug. to 15 Sep. 2007, in the area of Daejeon. The obtained result were as follows; 1. The population sociological feature of dental hospital and dental clinic showed that significant differences of dental service career(pM0.039). Dental service career of dental workers shows; below 3 years 42.9%, 4~6 years 34.7%, more than 7 years 22.4% in dental hospitals, below 3 years 30.4%, 4~6 years 26.7%, more than 7 years 43.0% in dental clinics(pM0.039). 2. The average score of dental workers knowledge in 'Critical item soaks in high-level disinfectants for 20minutes was 2.73V0.49 point, got from knowledge of dental instrument is appropriate to immerse before sterilization in the dental device disinfection(pM0.002). 3. In the general disinfection which it follows in education experience of chemical disinfectants direction for use, 'Direction for use by Spaulding process classification' responded that the correct answer was the education experience dental workers 60.0%, the education non-experience dental workers 39.5%(p=0.026). 4. In the dental device disinfection which it follows in education experience of chemical disinfectants direction for use. 'High level disinfection is not applied for the non-critical items and equipment' responded that the education experience dental workers 49.2%, the education non-experience dental workers 31.9%(pM0.045), 'Semi-critical items is applied same method in presence of the infection disease which it acts responded that the education experience dental workers 44.6% answer back, the education non-experience dental workers 24.4%(pM0.017). 5. 'A hand disinfectants of anticeptics have effect' the education experience dental workers 78.5% answer back, the education non-experience dental workers 52.9%(pM0.003). 1t uses with hand disinfectants when the instruments which be imbrued and patient contact', the education experience dental workers 78.5% answer back, the education non-experience dental workers 62.2%(pM0.026), 'Boric acid solution uses for the skin disinfectants the education experience dental workers 52.3% answer back, the education non-experience dental workers is 37.0%(pM0.016), 'Gluconate have effective difference which it follows in chemical disinfectant consistency and the solution type' education experience dental workers 72.3% answer back, education non-experience dental workers 47.9%(pM0.004). 6. The education experience dental workers were appeared higher than the education non-experience dental workers in knowledge of the disinfection and chemical disinfectants. Consequently system and the specialty education which is standardized continuously must be provided to all dental workers.

  • PDF

Interactions between Hydrodenitrogenation of Pyridine and Hydrodeoxygenation of m-Cresol over sulfided CoMo/γ-Al2O3 Catalyst (황화 CoMo/γ-Al2O3 촉매상에서 수첨탈질반응과 수첨탈산소 반응의 상호작용)

  • Kim, Hak-Soo;Park, Hea-Kyung;Kim, Kyung-Lim
    • Applied Chemistry for Engineering
    • /
    • v.2 no.2
    • /
    • pp.108-118
    • /
    • 1991
  • Interactions between pyridine hydrodenitrogenation (HDN) and m-cresol hydrodeoxygenation(HDO), and the kinetic analysis were studied over sulfided $CoMo/{\gamma}-Al_2O_3$ catalyst at the range of temperatures between 473 K and 723 K, the total pressures between $10{\times}10^5Pa$ and $50{\times}10^5Pa$, and the contact times between 0.0125 g-cat. hr/ml-feed and 0.03g-cat. hr/ml-feed. HDN of pyridine and HDO of m-cresol were inhibited by each other and the inhibition effect of HDO by pyridine is higher than that of HDN by m-cresol. But reactivity of m-cresol is higher than that of pyridine. The rate equations of pyridine and m-cresol were given to be ${\gamma}_{HDN}=k_{HDN}{\cdot}K_pC_p/(1+K_cC_c+K_pC_p)$ and ${\gamma}_{HDO}=k_{HDO}{\cdot}K_cC_c/(1+K_cC_c+K_pC_p)$ in terms of Langmuir-Hinshellwood-Hougen-Watson model. At each temperature, reaction rate constants and adsorption equilibrium constants were determined and activation energies of pyridine HDN and m-cresol HDO are 13.83kcal/mol, respectively and the heat of adsorption are -6.458 and -5.045kcal/mol, respectively.

  • PDF

The study on the penetration and washing features of blood on the surface of fabric (천에 혈액이 침투되는 특성 및 침투된 혈액이 세탁되는 특성 연구)

  • Kim, Yeounjeung;Lim, Jaehee;Hong, Sungwook
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.270-278
    • /
    • 2017
  • The absorption of blood onto the surfaces of white cotton, polyester, rayon, and nylon fabrics was studied. Different categories of fabrics (woven and knitted) with diverse thickness, were manually folded twice to obtain four fabric layers, and $100{\mu}L$ of human blood was dropped onto the surface of the fabrics. The amount of blood that penetrated the fabric layer and the shape of bloodstain observed on the fabrics were influenced by the chemistry, thickness, and texture of the fabric. The blood bearing fabrics were left to dry for 3 days, washed by hand using tap water, and Lumiscene was then sprayed onto the fabrics to enhance the latent bloodstain for comparison of the shape of the bloodstain before and after washing by hand. The features of the bloodstain after washing varied greatly with the recipient fabrics. Additionally, stronger luminescence was observed at the surface where the blood was deposited compared to the background. However, it was confirmed that physical contact during the washing can deform the original shape of the bloodstain. The effect of the drying time on the bloodstain after hand washing was also studied. $100{\mu}L$ of blood was dropped on the surfaces of the fabrics and dried for 0, 1, 12, 24, 72 h, and 7 days, then washed by hand, before the bloodstain was enhanced with Lumiscene. The results of this experiment indicated that the increased drying time induces stronger chemiluminescence of Lumiscene. However, after drying of the bloodstain for 7 days, the luminescence of the bloodstain was decreased at the blood deposited site and increased around the blood deposited site.