• Title/Summary/Keyword: contact effect

Search Result 3,294, Processing Time 0.029 seconds

Detection of immunity in sheep following anti-rabies vaccination

  • Hasanthi Rathnadiwakara;Mangala Gunatilake;Florence Cliquet;Marine Wasniewski;Mayuri Thammitiyagodage;Ramani Karunakaran;Jean-Christophe Thibault;Mohamed Ijas
    • Clinical and Experimental Vaccine Research
    • /
    • v.12 no.2
    • /
    • pp.97-106
    • /
    • 2023
  • Purpose: Rabies is a fatal but preventable disease with proper pre-exposure anti-rabies vaccination (ARV). Dogs, as household pets and strays, are the reservoir and vector of the disease, and dog bites have been associated with human rabies cases in Sri Lanka over the past few years. However, other susceptible species having frequent contact with humans may be a source of infection. One such species is sheep and immunity following ARV has never been tested in sheep reared in Sri Lanka. Materials and Methods: We have tested serum samples from sheep reared in the Animal Centre, Medical Research Institute of Sri Lanka for the presence of anti-rabies antibodies following ARV. Sheep serum samples were tested with Bio-Pro Rabies enzyme-linked immunosorbent assay (ELISA) antibody kits used for the first time in Sri Lanka and our results were verified by a seroneutralization method on cells (fluorescent antibody virus neutralization, FAVN test) currently recommended by World Organization for Animal Health and World Health Organization. Results: Sheep received annual ARV and maintained high neutralizing antibody titers in their serum. No maternal antibodies were detected in lamb around 6 months of age. Agreement between the ELISA and FAVN test, i.e., coefficient concordance was 83.87%. Conclusion: Annual vaccination in sheep has an effect on maintaining adequate protection against rabies by measurements of anti-rabies antibody response. Lambs need to be vaccinated earlier than 6 months of age to achieve protective levels of neutralizing antibodies in their serum. Introducing this ELISA in Sri Lanka will be a good opportunity to determine the level of anti-rabies antibodies in animal serum samples.

The effect of PVT process parameters on the resistance of HPSI-SiC crystal (PVT 공법의 공정 변수가 고순도 반절연 SiC 단결정의 저항에 미치는 영향)

  • Jun-Hyuck Na;Min-Gyu Kang;Gi-Uk Lee;Ye-Jin Choi;Mi-Seon Park;Kwang-Hee Jung;Gyu-Do Lee;Woo-Yeon Kim;Won-Jae Lee
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.34 no.2
    • /
    • pp.41-47
    • /
    • 2024
  • In this study, the resistance characteristics of semi-insulating SiC single crystals grown using the PVT method were investigated, considering the purity level of SiC source powders used in PVT growth and the cooling procedure after crystal growth. Two β-SiC powders with different purities were employed, and the cooling rate after growth was adjusted to achieve various resistance values. 4-inch HPSI-SiC ingots were grown using the PVT method, utilizing SiC powders with low nitrogen concentration and relatively high nitrogen concentration. These ingots were then subjected to different cooling procedures to modify the cooling rate. Transmission/absorption spectra and crystal quality of the grown crystals were analyzed through UV/VIs/NIR spectroscopy and X-ray rocking curve analysis, respectively. Additionally, electrical properties were investigated through non-contact resistivity analysis to identify the dominant factors influencing resistivity properties.

Study of the Effect of Surface Roughness through the Application of 3D Profiler and 3D Laser Confocal Microscope (삼차원 표면 조도 측정기와 삼차원 레이저 공초점 현미경 적용에 따른 표면 거칠기에 대한 영향 연구)

  • Hee-Young Jung;Dae-Eun Kim
    • Tribology and Lubricants
    • /
    • v.40 no.2
    • /
    • pp.47-53
    • /
    • 2024
  • Surface topography plays a decisive role in determining the performance of several precision components. In particular, the surface roughness of semiconductor devices affects the precision of the circuit. In this regard, the surface topography of a given surface needs to be appropriately assessed. Typically, the average roughness is used as one of the main indicators of surface finish quality because it is influenced by both dynamic and static parameters. Owing to the increasing demand for such accurate and reliable surface measurement systems, studies are continuously being conducted to understand the parameters of surface roughness and measure the average roughness with high reliability. However, the differences in the measurement methods of surface roughness are not clearly understood. Hence, in this study, the surface roughness of the back of a silicon wafer was measured using both contact and noncontact methods. Subsequently, a comparative analysis was conducted according to various surface roughness parameters to identify the differences in surface roughness depending on the measurement method. When using a 3D laser confocal microscope, even smaller surface asperities can be measured compared with the use of a 3D profiler. The results are expected to improve the understanding of the surface roughness characteristics of precision components and be used as a useful guideline for selecting the measurement method for surface topography assessment.

Research on Improving Drying Technology For Sewage Waste Using Direct Flotation Using Heat Storage Media (축열메디아 활용 직접부상방식을 이용한 하수찌꺼기의 건조기술 향상에 관한 연구)

  • Sung-Il Noh;Ung-Yong Kim;Sung-Gyun Jo;Hyun-Gon Shin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.4
    • /
    • pp.5-11
    • /
    • 2023
  • This study was conducted to improve energy efficiency and problems such as clumping and fouling in the glue zone that occur in the moisture content range of 40 to 60% when sewage dehydration residue is directly fed into the dryer. The temperature of the hot air is low at 270~300℃, and the paddle-type flotation method and dehydrated residue are applied to the circulated heat storage media to increase the contact area with the hot air, thereby reducing energy recovery and gas emissions. The water content of the dried residue is 2.7. ~7 .5%, the heat of evaporation of moisture was 608.0~690.6 kcal/kg·H2O, which confirmed an energy saving effect of about 8.8% compared to the heat of evaporation of moisture of 714.5 kcal/kg·H2O when no heat storage media was used.

Prediction of PTO Power Requirements according to Surface energy during Rotary Tillage using DEM-MBD Coupling Model (이산요소법-다물체동역학 연성해석 모델을 활용한 로타리 경운작업 시 표면 에너지에 따른 PTO 소요동력 예측)

  • Bo Min Bae;Dae Wi Jung;Jang Hyeon An;Se O Choi;Sang Hyeon Lee;Si Won Sung;Yeon Soo Kim;Yong Joo Kim
    • Journal of Drive and Control
    • /
    • v.21 no.2
    • /
    • pp.44-52
    • /
    • 2024
  • In this study, we predicted PTO power requirements based on torque predicted by the discrete element method and the multi-body dynamics coupling method. Six different scenarios were simulated to predict PTO power requirements in different soil conditions. The first scenario was a tillage operation on cohesionless soil, and the field was modeled using the Hertz-Mindlin contact model. In the second through sixth scenarios, tillage operations were performed on viscous soils, and the field was represented by the Hertz-Mindlin + JKR model for cohesion. To check the influence of surface energy, a parameter to reproduce cohesion, on the power requirement, a simple regression analysis was performed. The significance and appropriateness of the regression model were checked and found to be acceptable. The study findings are expected to be used in design optimization studies of agricultural machinery by predicting power requirements using the discrete element method and the multi-body dynamics coupling method and analyzing the effect of soil cohesion on the power requirement.

A New Composite Wall Inner Tie System Applied in Reinforced Concrete Modular Integrated Construction

  • Xiaokang ZOU;Jiang HUANG;Wenjie LU;Jun SHI;Zhen ZHAO;Tian SHI
    • International conference on construction engineering and project management
    • /
    • 2024.07a
    • /
    • pp.85-92
    • /
    • 2024
  • Reinforced concrete modular integrated construction (MiC) has been widely used in Hong Kong nowadays, but the solutions for temporary tying of the side walls during the construction of the composite wall have still shortcomings. Based on a MiC project in Hong Kong, this paper proposes a new inner tie system for composite wall. The system components are installed on the side walls of precast modules without penetrating through the side walls. After the loop is rotated to contact the hook, the tying effect can be generated when the concrete is poured on site between the middle gap of two modules. This system replaces tie bolts penetrating through precast side walls, so that the modules' interior fitting-out can be fully completed in factory and the on-site construction has no adverse effects on the internal decoration. This paper mainly describes the mechanism of the system, FEA simulation and optimization of the member size, as well as tensile and punching shear tests to verify the reliability, safety and to get more information about failure mode of the system. The system will be further examined by assembling 1:1 mockup modules, and finally applied to a real MiC project soon. The system can also act as permanent tie bars for the composite wall to reduce the total wall thickness, save the structural cost and increase the usable area. Compared with other existing tying methods in the industry, the system is easy to install, reliable to take loads, adaptable to large construction errors, and has the potential to be widely used in future practical projects.

Control of Ni/β-Ga2O3 Vertical Schottky Diode Output Parameters at Forward Bias by Insertion of a Graphene Layer

  • Madani Labed;Nouredine Sengouga;You Seung Rim
    • Nanomaterials
    • /
    • v.12 no.5
    • /
    • pp.827-838
    • /
    • 2022
  • Controlling the Schottky barrier height (φB) and other parameters of Schottky barrier diodes (SBD) is critical for many applications. In this work, the effect of inserting a graphene interfacial monolayer between a Ni Schottky metal and a β-Ga2O3 semiconductor was investigated using numerical simulation. We confirmed that the simulation-based on Ni workfunction, interfacial trap concentration, and surface electron affinity was well-matched with the actual device characterization. Insertion of the graphene layer achieved a remarkable decrease in the barrier height (φB), from 1.32 to 0.43 eV, and in the series resistance (Rs), from 60.3 to 2.90 mΩ.cm2. However, the saturation current (Js) increased from 1.26×10-11 to 8.3×10-7(A/cm2). The effects of a graphene bandgap and workfunction were studied. With an increase in the graphene workfunction and bandgap, the Schottky barrier height and series resistance increased and the saturation current decreased. This behavior was related to the tunneling rate variations in the graphene layer. Therefore, control of Schottky barrier diode output parameters was achieved by monitoring the tunneling rate in the graphene layer (through the control of the bandgap) and by controlling the Schottky barrier height according to the Schottky-Mott role (through the control of the workfunction). Furthermore, a zero-bandgap and low-workfunction graphene layer behaves as an ohmic contact, which is in agreement with published results.

The effect of early loading on the direct bone-to-implant surface contact of the orthodontic osseointegrated titanium implant (교정력이 골유착성 티타니움 임프란트의 초기 고정에 미치는 영향에 관한 실험적 연구)

  • Chung, Kyu-Rhim;Lee, Sung-Ja
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.173-185
    • /
    • 2001
  • The orthodontic osseointegrated titanium implant, a kind of intraoral skeletal anchorage can be an alternative to tooth-borne anchorage, in case that the conventional tooth-borne anchorage is not available or the anchorage is critical. This study was conducted to elucidate the effect of early loading on the osseointegration of the orthodontic titanium implant and the healing process of the impaired bone at the site of implant after removing it. In two adult beagle dogs24 osseointegrated titanium implants were inserted into the alveolar bone, with 12 implants placed in each dog. In dog1, 6 out of 12 implants were loaded with 200-300gm of force immediately after placing, and the remaining 6 implants were not loaded for 4weeks. In dog2, all 12 implants had healing period of 4weeks, and then were loaded with 200-300gm of force for another 4weeks. Following an observation period of 4 and 8 weeks, the animals were sacrificed. Then the implants and the surrounding bone of dog1 and dog2 were removed, respectively. Undecalcified sections along the long axis of implant were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features of tissues around implants anchored in dog1, there was no difference between immediately loaded implants and unloaded implants. Immature woven bone was ingrowing into the thread spaces from the original compacta and in direct contact with the implant surface in part. 2. The premature loading just after 4weeks healing period did not halt the progress of the osseointegration between bone and implant surface. The woven bone around the implants was maturing into the lamellar bone which resembled the structure of the original compacta at the end of 8weeks observation period. 3. Most implants with the inflammed surrounding mucosa were lost or mobile. The mobile implants were encapsulated by fibrous connective tissue which separated the implant surface from the bone. 4. The impaired bone at the site of the implant failed to anchor was showing recovery without inflammatory reaction 2weeks after removing, with the immaure woven bone lined by active osteoblasts and osteoid. Based on the results of this study, the integration of this orthodontic implant seemed to be impaired by the inflammation of the tissue surrounding the Implant rather than by early loading on implant, and increased with time lapsed after placing the implant. The use of implant described in this report can be recommended as an orthodontic anchorage unit immediately after insertion under the careful control of orthodontic force applied and plaque.

  • PDF

The effects of Galgŭnhaegit'ang and Won's-Galgŭnhaegit'ang for Taeŭmin on the immune response (태음인(太陰人) 갈근해기탕(葛根解肌湯)과 원특상(元特上)의 갈근해기탕(葛根解肌湯)이 면역반응(免疫反應)에 미치는 영향(影響))

  • Park, Seong-Sik;Ko, Byung-Hee;Song, Il-Byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.9 no.1
    • /
    • pp.315-337
    • /
    • 1997
  • In order to compare the dffects of $Galg{\breve{u}}nhaegit'ang$(葛根解肌湯) of "Dongeuisusebowon(東醫壽世保元)and Won's(元)-$Galg{\breve{u}}nhaegit'ang$(葛根解肌湯) of "Dongeuisasansinpyun(東醫四象新編)" on the immune respone, Sprague-Dawley male rats were used and randomly divided into four groups. Normal group was under normal condition, Control group was injected i.v. with 2mg/kg Methotrexate(MTX) on the 9th day and 11th day after sensitization with SRBC on the 5th day, $Galg{\breve{u}}nhaegit'ang$ group was fed with 1ml of $Galg{\breve{u}}nhaegit'ang$ and Won's-$Galg{\breve{u}}nhaegit'ang$ group was fed with 1ml of Won's-$Galg{\breve{u}}nhaegit'ang$ by oral during eighteen days. In the 9th day and the 11th day after oral feeding with medication, MTX was injected in tail of rats in order to reduce immune function. Leukocyte count, lymphocyte ratio, lymphocyte count of spleen, lymphocyte count of bone marrow, contact hypersensitivity to DNFB, morphologic change of thymus cell, and electropherogram of serum protein were estimated and compared according to the group. The results are as follows : 1. Before and after MTX injection, leukocyte(WBC) count was increased signigicantly in Won's-$Galg{\breve{u}}nhaegit'ang$ group compared to control group. $Galg{\breve{u}}nhaegit'ang$ group had no significant difference compared to control group. 2. Before and after MTX injection, lymphocyte ratio was not significantly different in Won's-$Galg{\breve{u}}nhaegit'ang$ group and in $Galg{\breve{u}}nhaegit'ang$ group compared to control group. 3. The lymphocyte count of spleen was increased significantly in $Galg{\breve{u}}nhaegit'ang$ group compared to control group and Won's-$Galg{\breve{u}}nhaegit'ang$ group. Won's-$Galg{\breve{u}}nhaegit'ang$ group had no significant difference compared to control group. 4. The lymphocyte count of bone marrow was increased significantly in Won's-$Galg{\breve{u}}nhaegit'ang$ group compared to control group and $Galg{\breve{u}}nhaegit'ang$ group. $Galg{\breve{u}}nhaegit'ang$ group had no significant difference compared to control group. 5. Contact hypersensitivity was increased significantly in Won's-$Galg{\breve{u}}nhaegit'ang$ group compared to other group. $Galg{\breve{u}}nhaegit'ang$ group had no significant difference compared to control groups. 6. In the morphologic change of thymus cell, control group compared to normal group had a indistinct boundary between cortex and medulla and lymphocyte cell density of thymus was low. $Galg{\breve{u}}nhaegit'ang$ group and Won's-$Galg{\breve{u}}nhaegit'ang$ group compared to control group had a definite boundary between cortex and medulla and lymphocyte cell density of thymus was high. 7. In the SDS-PAGE electropherogram of serum protein, Won's-$Galg{\breve{u}}nhaegit'ang$ group had a wide band of nearby 25,000 Dalton, and which meant IgG generated more actively. Considering this results, $Galg{\breve{u}}nhaegit'ang$ group and Won's-$Galg{\breve{u}}nhaegit'ang$ group have an effect on the depression of immune function induced by MTX, and especially Won's-$Galg{\breve{u}}nhaegit'ang$ group has an significant effect than $Galg{\breve{u}}nhaegit'ang$ group.

  • PDF

Effect of Mouthguard on Tooth Distortion During Clenching (이악물기 시 발생되는 치아변형에 대한 구강보호장치의 역할)

  • Lee, Yun;Choi, Dae-Gyun;Kwon, Kung-Rock;Lee, Richard Sung-Bok;Noh, Kwan-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.405-417
    • /
    • 2010
  • Previous studies have already shown that mouthguard is effective in protecting jaw bone, teeth and oral tissue against sports trauma. However, other than severe trauma, repetitive force, such as disorders like clenching, cause teeth or oral tissue damage. These kinds of disorders usually present pathologic attrition in the posterior teeth, resorption in alveolar bone, loss of teeth and destruction of occlusion. Wearing a mouthguard is believed to be effective in preventing these disorders. But its effect is not examined thoroughly enough. The purpose of this study is to identify whether mouthguard is effective in reducing strain caused by clenching. Mandibular first molars in the normal occlusal relationship without any history of dental treatment were chosen. Biaxial type strain gauge was placed on the buccal surface of the tooth. Having maximum occlusal force, measured by load cell, as a standard, clenching intensity were divided into three stages; moment of slightly tooth contact, medium bite force (50% of maximum bite force), maximum bite force. Strain occurring in dentition in each stage with and without mouthguard was measured. Changes in strain (on dentition) between each stage and difference in strain, between with or without mouthguard were recorded by PCD-300 analyzer and PCD-30 soft ware. The data was statistically analyzed by Wilcoxon signed rank test. The following results were drawn; Without mouthguard, strain given on dentition increased as the clenching force increased. With mouthguard, strain given on dentition also increased as the clenching force increased. With mouthguard, strain decreased, in all cases of clenching force stages. Data on the moment of slightly tooth contact stage, had no statistical significance. However, with mouthguard, 50-90% of decrease in strain could be obtained in maximum occlusal force, compared to the group without mouthguard. Mouthguard decreased the strain on the dentition, caused by clenching. Therefore, mouthguard seems to be effective in preventing damage on dentition, by acting against clenching, which occurs both consciously and unconsciously during sports activities.