• Title/Summary/Keyword: construction material

Search Result 4,992, Processing Time 0.034 seconds

Cyclic Behavior of Wall-Slab Joints with Lap Splices of Coldly Straightened Re-bars and with Mechanical Splices (굽힌 후 편 철근의 겹침 이음 및 기계적 이음을 갖는 벽-슬래브 접합부의 반복하중에 대한 거동)

  • Chun, Sung-Chul;Lee, Jin-Gon;Ha, Tae-Hun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.275-283
    • /
    • 2012
  • Steel Plate for Rebar Connection was recently developed to splice rebars in delayed slab-wall joints in high-rise building, slurry wall-slab joints, temporary openings, etc. It consists of several couplers and a thin steel plate with shear key. Cyclic loading tests on slab-wall joints were conducted to verify structural behavior of the joints having Steel Plate for Rebar Connection. For comparison, joints with Rebend Connection and without splices were also tested. The joints with Steel Plate for Rebar Connection showed typical flexural behavior in the sequence of tension re-bar yielding, sufficient flexural deformation, crushing of compression concrete, and compression rebar buckling. However, the joints with Rebend Connection had more bond cracks in slabs faces and spalling in side cover-concrete, even though elastic behavior of the joints was similar to that of the joints with Steel Plate for Re-bar Connection. Consequently, the joints with Rebend Connection had less strengths and deformation capacities than the joints with Steel Plate for Re-bar Connection. In addition, stiffness of the joints with Rebend Connection degraded more rapidly than the other joints as cyclic loads were applied. This may be caused by low elastic modulus of re-straightened rebars and restraightening of kinked bar. For two types of diameters (13mm and 16mm) and two types of grades (SD300 and SD400) of rebars, the joints with Steel Plate for Rebar Connection had higher strength than nominal strength calculated from actual material properties. On the contrary, strengths of the joints with Rebend Connection decreased as bar diameter increased and as grade becames higher. Therefore, Rebend Connection should be used with caution in design and construction.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.

A Study on the Activation of Construction Practical Course through the Analysis of the Satisfaction Level in NCS Learning Module (NCS 학습모듈 만족도 분석을 통한 건설 교과 실무과목 수업 활성화 방안)

  • Lee, Jae-Hoon;Kim, Sun-Woo;Park, Wan-Shin;Jang, Young-Il;Kim, Tae-Hoon
    • 대한공업교육학회지
    • /
    • v.45 no.1
    • /
    • pp.63-83
    • /
    • 2020
  • The purpose of this study is to provide the basic materials needed to plan the NCS Learning Module to be used effectively in practical courses. In this study, teachers and students' satisfaction surveys were collected about the NCS (National Competency Standards) learning module, career and field practice, practical environment used in the construction subject course. This study was conducted on public high schools in Chungcheong province (including Daejeon), which is operating practice course using the NCS learning module. The research questions are as follows; First, how was the satisfaction of teachers and students in the practical subject class using NCS learning module? Second, what is the degree of satisfaction of teacher's career and field practice guidance, student's career decision and field practice after the practical course using NCS learning module? Third, the satisfaction level of the developed NCS learning module and practical subject class using the same was determined by setting whether the number of training of NCS-related teachers or the presence or absence of on-the-job training of students were affected? The results of the study are as follows; As a result of comparing the teachers' and students' satisfaction, the students showed satisfaction in all items, whereas the teachers showed 'content level', 'interest', 'necessary knowledge', 'skill acquisition', 'Improvement of practical skills (level of skill performance)', 'scale of experimental practice', and 'items of experimental practice equipment' were dissatisfied. It was found that the number of NCS related teachers' training (or absence) or the presence of students on the field had an effect on the satisfaction of the developed NCS learning module and the practical course using it. In order to fully utilize the developed NCS learning module in the practical course, it is required to develop and construct the teaching material of the teacher who can serve as an intermediary for conceptualization and understanding of job skills. It is necessary to increase the number of education and training specialists to positively reflect the demands of the education field.

A Study of Iljiam Tea Garden of Daeheung-sa at Mt. Dooryun - Focusing on the Comparison between Poetry and Current State - (두륜산 대흥사 일지암 다정(茶庭)의 일고찰(一考察) - 시문과 현황 비교를 중심으로 -)

  • Rho, Jae-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.3
    • /
    • pp.97-110
    • /
    • 2012
  • This study aimed at considering the original shape of Iljiam Tea Garden at Mt. Daedun. In order to accomplish our goal, we tried to strengthen the authenticity of construction of Iljiam by comparing its space structure depicted in the poetry of Choeui(艸衣) the monk with its current restored state. According to the clues and situation in the poetry along with symbolic words like 'Choeui' and 'Ilji(一枝)', Iljiam seemed to be a tea garden with elegant and celestial beauties, and with a nice view where Choeui the famous monk searched for the highest state of enlightenment by enjoying and living in nature. When we compared the plural aspects of Iljiam like Dacheon(茶泉), Dajo, Mulhwak, Darim(茶林), Chaewon(菜園), and Yeonji(蓮池) with those of Dasan Tea Garden[茶山草堂], we could see that the basic components of tea-culture space of both gardens are the same, showing the organizational principle of the top and bottom area to stress reading and studying. When it is restored, the authenticity of Iljiam should be pursued by linking spatial, historical, and landscaping characteristics as the space of which Choeui the monk carried out Zen meditation and mastered tea. However, the recent grand scale Buddhist business like the expansion of access road and construction of Buddhist sanctuary and Seolimdang became the biggest threat to the authenticity. Especially, it was emphasized many times in various poetry that the view from Iljiam and its surroundings is extraordinary, so it is critical to get rid of obstacles to the view from Iljiam and its surroundings in order to restore Iljiam as its genuine form. The current Iljiam should be re-made because it is like a leaf-roofed garden, not like a hermitage. However, the opinion that Jawoohongryeon-sa(紫芋紅蓮社) is somewhat a Taoistic and Taoist hermit space with a special shape adopted the pattern of building of the Joseon period rather than a Buddhist building can be accepted as long as other convincing historical evidences are found out, considering the ideology of uniting Confucianism and Buddhism and the spirit of Taoist hermit found out from poetry of Choeui and his friends. In conclusion, the restoration of Iljiam in 1979 was carried out to restore the place of Iljiam rather than to restore the originality of Iljiam by combining and referring domestic cases of tea gardens. However, there is not much material for restoration even though the main frame of Iljiam was distorted. Nevertheless, the top and bottom ponds should be constructed as a rectangle shape. In addition, it can be improved much in terms of plants and trees. It is necessary to restore bamboo forest, which was razed in order to make a tea plantation around Seolimdang, to set vines of arbors above the upper limbs, to plant pine trees and willow trees inside of the garden, and to put Dajeolgu under the corner of the eaves. Especially, the bamboo forest emphasized in poetry and took care of by Choeui himself should be restored inside of the garden.

A Study The Structural Stability of the Fence Ohgokmun Soswaewon Factor Analysis (소쇄원 오곡문 담장의 구조적 안정에 미치는 요인 분석)

  • Jang, Ik-Sik;Jeon, Hyeong-Soon;Ha, Tae Ju;Lee, Jae-Keun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.4
    • /
    • pp.113-122
    • /
    • 2013
  • In this study, the traditional structure of the impact on the stability analysis. Korean traditional landscape architecture column space of stonework stable composition as the foundation of the fence for a long time been known to fall down and not maintained. The destination of research Ohgokmun Damyang Soswaewon fence which is in harmony with nature is one of the traditional structures that affect its shape without being kept so far came true. This includes our ancestral wisdom and that wisdom can guess guesswork. But I let the traditional reproduction incidence structures frequently. This deviation from the traditional method of construction application of shorthand stand. Thus, the subject of this study, the factors that do not fall down fences Ohgokmun solution is to indirectly gain the weak. In addition, epidemiological studies and the methods of calculation of the inferred physical examination, the results of the analysis were derived through the following. First, the internal factors of the fence Ohgokmun constituting the structural member and the coupling of the scheme. 1) based on stable ground. Greater role in the country rock The fact that the settlement will have no symptoms. 2) to minimize the friction caused by hydrological water to remove the two-pronged process through stone work building form and menu sustaining power in hydrology and flooding made against the bypass channel. 3) due to the load bearing capacity and durability to withstand the strength of the material and the construction of structures in the form of a dispersion of power between each individual to maximize the process of getting traction was applied. Second, external factors Ohgokmun fence the results obtained through the calculation of the dynamics of repair, is greatly affected by the wind and the water gate of the fence, but the action of the structural stability of the lack of power that hurt enough conclusion. In this study, the results of the structure of internal and external influence as well through the structure can be viewed as composed consisting. However, over the next follow-up in terms of climate and environmental factors due to the fact that the fall might.

A re-appraisal of scoring items in state assessment of NATM tunnel considering influencing factors causing longitudinal cracks (종방향균열 영향인자 분석을 통한 NATM터널 정밀안전진단 상태평가 항목의 재검토)

  • Choo, Jin-Ho;Yoo, Chang-Kyoon;Oh, Young-Chul;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.479-499
    • /
    • 2019
  • State assessment of an operational tunnel is usually done by performing visual inspection and durability tests by following the detailed guideline for safety inspection (SI) and/ or precision inspection for safety and diagnosis (PISD). In this study, 12 NATM tunnels, which have been operational for more than 10 years, were inspected to figure out the cause of longitudinal cracks for the purpose of modifying the scoring items in the state assessment NATM tunnel related to the longitudinal crack and the thickness of concrete lining. All investigated tunnels were classified into four groups depending on the shape and usage of each tunnel. The causes of longitudinal crack occurrence were analyzed by investigating the correlations between the longitudinal crack and the following four factors: the patterns of ground excavation; construction state of primary support system; characteristics of material properties of the concrete lining; and thickness of lining which was obtained by Ground Penetration Radar (GPR) tests. It was found that influencing factors causing longitudinal cracks in the lining were closely related with the construction condition of the primary support system, i.e. shotcrete, rockbolt, and steel-rib; crack occurrences were not much affected by the excavation patterns. As for the properties of concrete lining materials, occurrence of the longitudinal crack was mostly affected by the following three items: w/c ratio; contents of cement; and strength of lining. When estimating the lining thickness of the concrete lining by GPR tests and taking thickness effect into account in the statement assessment, it was concluded that increase of the index score by an average of 0.03 (ranging from 0.01 up to 0.071) is needed; a more realistic way of state assessment should be proposed in which the increased index score caused by lack of lining thickness should be taken into account.

A Study on the Structure and the owners of the Royal Tombs of the Goryeo Dynasty (고려왕릉의 구조 및 능주(陵主) 검토)

  • Lee, Sang June
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.2
    • /
    • pp.4-19
    • /
    • 2012
  • There remain many royal tombs of the Goryeo Dynasty in Gaeseong and Ganghwa. During the Goryeo Dynasty, these royal tombs were taken over tradition of tomb construction style from previous generation, and they completed their own inventive style. Furthermore they handed down those style to the Joseon Dynasty. The area of tomb was divided into 3 or 4 steps, and stone figures and T-shaped houses for sacrifice were arranged on each steps. It was the stone chamber of lateral opening style which had an entrance to southward, and it was formed as a rectangular box-shaped with a pile of stone walls and a flat ceiling. There was a coffin stand in the middle of floor, and traditional bricks were around them. The wall side and ceiling had been whitewashed and painted pictures. These are general characteristics for the tomb construction style of the Goryeo Dynasty. By the way, we can notice a number of features except those general things with inspection in detail. In early days, we confirmed 1step-parallel fulcrum ceiling, coffin stand of all in one stone, bier of burial artifact, and mural of plant material as a set, but they were changed as flat ceiling, Red-stone wall with rectangular stone, coffin stand set as stone pillar through the period of transitional form as of in the late 12th century. In case of several royal tombs, the fragments of king's epitaph which were confirmed from tombs could be defined owners clearly, and there were considerable timing difference between the large numbers of celadons which were excavated with the fragments of king's epitaph and recording chronologically of stone chamber structure. The reason for timing difference is that posterity artifacts were buried through repairing courses by occasion of destruction caused by robbing of the royal tombs. Meanwhile I inferred the existing hypothesis about owners of royal tombs and autonym ones in comparison the burial spot direction of hypothesis ones and outcomes of excavation. Therethrough, some hypothesis about owners of royal tombs such as Myung-neung which was assumed as tomb of the King Choongmok were not correct.

Design and Management Direction of Smart Park for Smart Green City (스마트 그린시티 구현을 위한 스마트 공원 설계·관리 방향)

  • Kim, Yong-Gook;Song, Yu-Mi;Cho, Sang-kyu
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.6
    • /
    • pp.1-15
    • /
    • 2020
  • The purpose of this study is to propose a direction for designing and managing a smart park for realizing a smart green city and to present measures in the landscape field to foster related industries. The research process is as follows. First, the concept of a smart park was operationally defined through a literature review, and three principles to be considered in the process of creation and management were established. Second, in terms of the three principles, problems and implications for improvement were derived through an analysis of established cases of smart parks in new and pre-existing cities. Third, a pool of designs and management standards for each spatial component of a smart park was prepared through literature and case studies, and then further refined through brainstorming with experts in related fields. Fourth, measures were suggested to the government, local governments, and the landscape field to promote smart park creation and management. The main findings are as follows. First, the concept of a smart park is defined as "a park that contributes to securing the social, economic, and environmental sustainability of cities and local communities by supporting citizens' safe and pleasant use of parks and improving the management and operational efficiency by utilizing the digital, environment, and material technologies." Second, the three principles of smart parks are to improve the intrinsic value of parks, to improve the innovative functions of parks to solve urban problems, and to make the design, construction, and management process smart. Third, improvement implications were derived through the analysis of cases of smart parks creation in new and pre-existing cities. Fourth, the directions for smart park design and management were suggested in five aspects: green area, hydroponic facility area, road and plaza area, landscape facilities area, and park design method. Fifth, as for policy implications for revitalizing the construction and management of smart parks, the development of smart park policy business models by city growth stage, and park type, the promotion of pilot projects, the promotion of smart park projects in connection with the Korean New Deal policy, and smart park policies led by landscape experts were presented.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.