• Title/Summary/Keyword: construction control

Search Result 5,209, Processing Time 0.029 seconds

Application of Seismic Isolation and Vibration Control in Korea (우리나라의 면진 및 진동제어)

  • Lee, Dong-Guen;Kim, Tae-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.67-77
    • /
    • 2006
  • Seismic activity of Korea is not so high as that of Japan or California and most of the structures were designed without considering the influence of earthquakes until the first seismic design code was enforced in 1988. Therefore, it was very hard to find seismically isolated structures in Korea until 1980's. Korean engineers assumed that the seismic isolation or vibration control would be useful only in a high seismicity region while such technologies can be quite useful in a low seismicity region for the efficient reduction of earthquake damages. Recently, Korean engineers began to have interest in the seismic isolation or vibration control and applied it to some important structures such as LNG storage tanks, many bridges and several buildings. However, design codes are not defining such useful advanced technologies for the design of building structures and several projects employing seismic isolation or vibration control in the design of structures had difficulties in obtaining construction permit from the local government. Therefore, it is an urgent requirement to introduce these advanced technologies in the seismic design code.

A Study on Measuring Soil-Water Characteristic Curve Using a Suction Control Technique (흡입력 조절 기법을 이용한 함수특성곡선 측정에 관한 연구)

  • Lee, Joonyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5587-5594
    • /
    • 2012
  • Determination of the soil-water characteristic curve is one of the most important things to solve geotechnical engineering problems. Expecially, convenient and reliable method to measure the soil-water characteristic curve during drying and wetting cycles is required with lower labor input, more independence from operator experience, and shorter testing time than other available methods. Many measurement methods including the flow pump system have been developed to characterize the soil-water characteristic curve for the several decades. This study measured the soil-water characteristic curve during drying and wetting cycles using a suction control technique with the flow pump system. Two test materials were used for determination of the soil-water characteristic curve, and it is concluded that suction control technique is suitable for determination of the soil-water characteristic curve and characterization of the hydraulic hysteresis with varying test conditions. Especially, the suction control technique can reduce error of measurement and save time in measuring the soil-water characteristic curve due to automated system and high degree of precision.

Damper Configuration for Seismic Performance Improvement of Heavy Facilities with Frictional Sliding Behavior inside Building (마찰 슬라이딩 거동을 보이는 건물 내 중량 설비의 내진성능 향상을 위한 감쇠기 연결 방안)

  • Ok, Seung-Yong;Park, Kwan-Soon;Lee, Jeeho
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.53-61
    • /
    • 2020
  • This study proposes a new damper configuration for seismic performance improvement of heavy sliding facilities inside a building. For this purpose, we deal with two connection types of control system, and the parametric study has been performed to investigate their comparative seismic performances according to the variations of the control capacity. In order to simulate the seismic responses of the proposed system, we employed a recently-developed seismic response analysis method that can deal with the two-mass system with nonlinear frictional sliding behavior. The numerical results demonstrate that the typical method of diagonal bracing damper connection can exhibit effective control performance both on structure and the heavy sliding facilities, whereas the structure-facilities connection method does not show any control effect on both responses. On the other hand, the typical method has some limitations that it can adversely cause excessive sliding of the facilities, depending upon the frequency characteristics of structure and earthquake. On the contrary, the structure-facilities connection method is very effective in reducing the sliding displacement of the heavy facilities, even with small amount of control capacity. Thus, the following potential expectations can be inferred from these results: The typical diagonal bracing damper connection method will have some promising benefits in controlling the sliding facilities inside the building as well as the building itself, and the structure-facilities connection method can be a cost-effective way of protecting the internal heavy important facilities inside the structure already designed with sufficient seismic performance.

Implementation of Multilateral Control System for Small UAV Control-Focused on Design (소형 무인기 통제를 위한 다자간 방식 관제시스템 구축방안-설계 중심으로)

  • Choi, Hyun-Taek;Kim, Seok-Kwan;Ryu, Gab-Sang
    • Smart Media Journal
    • /
    • v.6 no.4
    • /
    • pp.65-71
    • /
    • 2017
  • In this paper, we propose a design method for the construction of LTE-based small unmanned aerial vehicle control system to quickly and reliably collect multiple small unmanned aerial vehicle position information simultaneously flying all over the country. In particular, the main requirements are the network (N/W), hardware (H/ W), software(SW), Database(DB), development architecture, and business needs. To satisfy these requirements, N/W, H/W, SW, DB design, and architectural design plan were suggested regarding the design requirements of a small UAV system. To effectively control the small unmanned multi-party system in the system design, the architecture is divided into the front-end service area and the back-end service area according to the function and role of the unit system. In the front-end service area that grasps and controls the position and state of small unmanned aerial vehicles (UAVs), we have studied the design part that can be expanded to N through TCP/IP network by applying Client PC method.

The Study on Test for Control of Weeds Invasion in Constructed on Upper Embankment in the Shoulder of a Expressway (고속도로 갓길 외측 성토상단의 잡초침입 억제를 위한 시험 연구)

  • Jeon, Gi-seong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.6
    • /
    • pp.227-237
    • /
    • 2015
  • From January 2013 to October 2015, weed invasion control techniques was tested in the test road of Jungbunaeryuk expressway so as to collect preliminary data for the management methods of the upper exterior banking of expressway shoulders. Then, monitoring was conducted and its results are as follows. Mat (sheet), solidifying agent, and mulching (wood chips) were applied for the test and their initial effects of preventing weed invasion were all excellent. It was found that the homogeneity of the wood chip mulching method needs to improve. In the mat method and the mulching method were found to have the most excellent economic feasibility and aesthetics, respectively. The covering degree was found to be the highest at 80% in the control site, followed by the wood chip site at 20% and the solidifying agent site and the non-woven fabric site at 5% each. As for species diversity, the control had the largest variety of species. Two years after the construction, many different species of plants invaded and were growing. Plants including weed didn't tend to invade the slopes applied with non-woven fabric. In addition, weed didn't invade the solidifying agent site and the aesthetics of the upper exterior banking of expressway shoulders was found to be excellent. The wood chip site was found to require consistent management for preventing weed invasion. The mat (sheet) site, the solidifying agent site, and the wood chip mulching site were found to have excellent weed prevention effects. As time passed, the mat (sheet) site and the solidifying agent site showed better weed prevention effects. However, they need consistent monitoring for further application.

A Study for Storage Reallocation of Multipurpose Reservoir(I) - Flood Control Storage Analysis (다목적댐 용량 재할당에 대한 연구(I)- 치수용량 분석)

  • Yi, Jae-Eung;Kwon, Yong-Ik;Yoon, Young-Nam;Ahn, Tae-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.4
    • /
    • pp.273-281
    • /
    • 2004
  • Generally, reservoir storage is allocated according to planned purposes established before construction and operating policies are established through release control. The established reservoir allocation is hardly changed unless the special cases such as raising dam or changed purposes occur It Is, however, likely that public needs and objectives can be changed as time go on, the study for multipurpose reservoir storage reallocation is performed as an alternative to reflect these. In this study, flood control analysis is performed for several alternatives of reallocation for the Daechung multi-purpose reservoir in Geum river. As a result, it is confirmed that flood control capability is not decreased compared to single operation of Daechung reservoir for the same flood condition even if conservation level of Daechung multi-purpose reservoir is increased.

Experimental Study for Construction of Mouth Care in Chemotherapy Patients (화학요법을 받는 암환자의 구강간호전략을 위한 연구)

  • 변영순;김애경
    • Journal of Korean Academy of Nursing
    • /
    • v.26 no.2
    • /
    • pp.428-442
    • /
    • 1996
  • Stomatitis is a common toxicity associated with the administration of certain cancer chemotherapeutic agents used in the treatment of malignant tumors. It represents one of the most distressing side effects of cancer chemotherapy and can interfere with the patient's ability to eat, be the cause of much pain and discomfort, and require the use of potent analgesics. The situation also creates favorable conditions for local infection which may lead to septicemia. Several authors have identified the need to establish protocols for the control and treatment of the oral discomfort associated with oral mucositis as a result of chemotherapy. Thus this study attempted to development of oral care protocol for chemotherapy patients. The effects of the mouth care using sterile normal saline, nystatine solution on oral stomatitis were investigated in 30 patients on chemotherapy. The subsect were divided into three groups : control group : not gargling experimental group A : normal saline gargling (4 times a day) experimental group B : nystatine solution gargling(4 times a day) The Oral Assessment Guide (OAG) was used to assess oral status three times(once in the prechemotherapy period, on 5th, 10th day of post chemotherapy) Oral culture was used to assess oral infection on 5th day of postchemotherapy. Data was analyzed on SAS program which used repeated ANOVA, t-test, X/sup²test. The results are as follows : 1. The incidence of stomatitis was higher in the control group and experimental group A than in experimental group B.(X/sup²=0.002 P=0.001). The grade of stomatitis(mean of total score) for patients in the experimental group B were significantly lower than in the experimental group A F=1.96 P=0.0024). In incidence of tongue change, control group, experimental group B were significantly higher than experimental group B(F=6.84 P=0.0039). In control group and experimental group A. oral infection due to pathogenic bacteria were identified. In conclusion, mouth care with nystatine solution four times a day could reduce the incidence of stomatitis and secondary oral infection due to stomatitis. Thus active mouth care protocol which used to nystatine solution gargling need to prevention of stomatitis in chemotherapy patients.

  • PDF

Development of a Wireless Control System for Rice Transplanter of Walking Type(II) -Field Test of the Experimental Machine- (보행(步行) 이앙기(移秧機)를 위(爲)한 무선자동제어(無線自動制御) 시스템의 개발(開發)(II) -공시기(供試機)의 포장실험(圃場實驗)-)

  • Kim, C.S.;Choi, K.H.;Min, Y.B.;Kim, S.T.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.3
    • /
    • pp.213-222
    • /
    • 1992
  • To develop the wireless remote opreating system of walking rice transplanter, this study was carried out for manufacturing the wireless remote control system acting upon the transplanter. The first report of this study contained about the construction and operating method of a developed remote control system for 2-row walking type transplanter. It is the second report about the field test for an experimental transplanter being attached a wireless control system and for a conventional transplanter. The test was executed to investigate the characteristics of velocity, rectilinearity, turning time, interval of roots and of rows, and field capacity in accordance with various engine speeds for an experimental transplanter. The measurements of this test were compared with those of the conventional transplanter. The obtained results were as follows : 1. The operating velocity of the experimental transplanter was faster than the conventional one when the high speed range of the engine but the variances were very large. 2. The rectilinearity, interval of raws and of roots, and the turning time of the experimental transplanter was inferior to the conventional one at some speed ranges of the engine. 3. Field capacity of the experimental transplanter was superior to the conventional one at high speed of the engine. 4. There were some disadvantages for the experimental transplanter to operate, because it was constructed without any aid devices, such as float and hydraulic system for instance. But if the remote control system of this study equip at the modern walking transplanter, it will be improved and utilized without defects which was revealed from this test.

  • PDF

The effect of a risk factor on quantitative risk assessment in railway tunnel (철도터널에서 위험인자가 정량적 위험도 평가에 미치는 영향)

  • Yoo, Ji-Oh;Kim, Jin-Su;Rie, Dong-Ho;Shin, Hyun-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.117-125
    • /
    • 2015
  • Quantitative risk assessment (QRA) of railway is to create a variety of scenario and to quantify the degree of risk by a result of the product of accident frequency and accident. Quantitative risk Assessment is affected by various factors such as tunnel specifications, characteristics of the fire, and relation of smoke control and evacuation direction. So in this study, it is conducted that how the way of smoke control and the relation of smoke control and evacuation direction affect quantitative risk assessment with variables (the tunnel length (2, 3, 4, 5, 6 km) and the slope (5, 15, 25‰)). As the result, in a train fire at the double track tunnel (Area = $97m^2$), it is most efficient to evacuate to the opposite direction of smoke control regardless of the location of train in train fire. In addition, under the same condition, index risk in mechanical ventilation up to 1/10.

Implementation of PC-based education PLC(Power Line-network Communication) control system using Labview (LabView를 이용한 PC기반의 교육용 전력선망 통신 제어시스템 구현)

  • Park, Tae-Jin;Lee, Un-Sun;Lee, Sang-Hee;Lee, Jong-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.3
    • /
    • pp.730-739
    • /
    • 2013
  • More than 30% of energy in Korea was spent in lighting part and then the consumption level and $CO_2$ emission will be increase from now. In this like situation, control-system construction for street-lamp of a smart grid-based that it has important meaning. Nowadays as a result, as an trying to utilize using Power-line-network communication modem and application a terminal in industrial fields, in this paper, we are want to implement the Power-line-network communication control system of PC-based. Therefore it will be use varied communication test-equipment and tools through the system. For experimentation, using the MODEM was able to use Planet production of based on the ZIC protocol and then the application program use the LabView. The result is primarily focused on equipments control by the PLC, and that we are able to perform each test with PLC equipment for experiment it.