• Title/Summary/Keyword: construction control

Search Result 5,209, Processing Time 0.03 seconds

An Experimental Study on the Behavior of Reinforced Concrete Beams using Recycled Coarse Aggregate (재생 굵은골재를 사용한 철근 콘크리트 보의 거동에 관한 실험연구)

  • Lee, Myeong-Gyu;Kim, Gwang-Seo;Lee, Geun-Ho;Yun, Geon-Ho;Jeong, Sang-Hwa
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.133-141
    • /
    • 2004
  • The object of this study is to investigate experimentally the shear behavior of reinforced concrete beams using recycled coarse aggregate. At first, the specimens are manufactured for the compressive strength of 210kgf/$\textrm{cm}^2$ with recycled coarse aggregate ratio of 0%, 20%, 40%, 60%, 80%, 100%, respectively. From the results, Reinforced concrete beams using recycled coarse aggregate were made with recycled coarse aggregate ratio of 0%, 20%, 40%, 60%, 80%, with stirrups and recycled coarse aggregate ratio of 0%, 20%, 40% without stirrups. The results of crack pattern and failure mode, load-displacement curve(center point and load point) and load-steel curve(compressive, tensile, stirrup) were analysed. It is concluded from the test that the shear behavior of recycled concrete beams is determined to have similar behavior of normal concrete beams. Therefore, from this study the application of recycled concrete to concrete structures may be possible. But, for using the recycled concrete widely, it is expected that the more studies on quality control, substitution ratio and mix design related with recycled concrete are necessary.

Traffic Noise Reduction of Sunken Squares (썬큰광장의 교통소음 감쇠 효과)

  • Min Jang-Ki;Chang Tai-Hyun;Jung Jae-Man
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.5
    • /
    • pp.35-42
    • /
    • 2004
  • This study examines the traffic noise reduction effects of the diverse efficiency features of a sunken square, and investigates the reduction effects and characteristics of noise alterations according to the construction conditions in order to verify its possibility as a new noise reduction facility. The measured data were analyzed. As a result, (1) the traffic noise from the roads around the sunken squares exceeded the regulatory standards; (2) the sunken squares were protected from noise; (3) the sunken spaces yielded a greater reduction by 6∼7dB than the flat ground thanks to the diffraction effect; and (4) there were fine changes to noise according to the conditions of space construction. In short, a sunken square has the potential to afford new applications as a noise reduction facility in a highly concentrated downtown with the existing defects solved. In addition, its use for effective noise control is evident based on the noise characteristics of a space. Future studies need to include efforts to provide clearer quantitative data, as well as research on shape, layout, and materials.

Thermal cracking assessment for nuclear containment buildings using high-strength concrete

  • Yang, Keun-Hyeok;Mun, Jae-Sung;Kim, Do-Gyeum;Chang, Chun-Ho;Mun, Ju-Hyun
    • Computers and Concrete
    • /
    • v.26 no.5
    • /
    • pp.429-438
    • /
    • 2020
  • To shorten the construction times of nuclear facility structures, three high-strength concrete mixtures were developed with specific consideration given to their curing temperatures, their economic efficiency, and the practicality of their quality control. This study was conducted to examine the temperature rise profiles of these three concrete mixtures and the potential for early-age thermal cracking in the primary containment vessel of a nuclear reactor with a wall thickness of 1200 mm. The one-layer placement height of the concrete for the primary containment vessel was increased from the conventional 3 m to 3.5 m. A nonlinear finite element analysis (FEA) was conducted using the thermal properties of concrete determined from the isothermal hydration and adiabatic hydration tests, and tuned through comparisons made with temperature rise profiles obtained for 1200-mm-thick mock-up wall specimens cured at temperatures of 5, 20, and 35℃. The hydration heat performance of the three concrete mixtures and their potential to produce thermal cracking in nuclear facilities indicate that the mixtures have considerable potential for practical application to the primary containment vessel of a nuclear reactor at various curing temperatures, fulfilling the minimum requirements of the ACI 301 and minimizing the likelihood of the occurrence of thermal cracks.

Field Application of the Slit Type Coastal Structures under Waves and Currents

  • Park, Sang-Gil;Kang, Sug-Jin;Kim, Kang-Min;Kim, Suk-Mun;Lee, Joong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.34 no.9
    • /
    • pp.711-718
    • /
    • 2010
  • Redevelopment of the domestic small fishing ports is being started in earnest by applying the environmentally friendly technology in order to attract tourists. For the purpose of improving water quality in the harbor, selection of breakwater type might have the priority to secure calmness and stability. Therefore, this study is to determine the hydraulic characteristics of reflective ratio, installation efficiency and stability of the special type of blocks through the hydraulic model experiment. The results were introduced to analyze for the effect of infield construction work through numerical analysis. Gujora, a small fishing port in southern Korea, is affected by the waves of SSE, S, SSW direction and strong tidal currents. The results of applying cylindrical slit block show that stability of the blocks and harbor calmness were secured. Considering that the pass rate of a long period wave is still excellent, the primary objective of wave control and the secondary objective of improving water exchange are satisfied simultaneously.

The mold form coating material research for the exposure concrete surface control (노출콘크리트 표면처리를 위한 거푸집 코팅재료 연구)

  • Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.137-143
    • /
    • 2010
  • This research is a comparative analysis of the surface gloss of concrete depending on the coating material added to the cast, and includes analyses of the surface gloss of specimens made of cement mortar, with and without the addition of superplasticizer. In terms of coating material, the 7th material, which is part of a liquid packaging material, was shown to have the highest gloss, and was followed by the 3rd material, which uses transparent film. As the level of gloss is shown to vary depending on the material used for the coating film, it can be interpreted that the surface gloss can differ depending on surface particles and chemical composition factors. To make a concrete surface smooth, it is more effective to use a coating material with impermeability and a highly dense surface.

Analysis of the Correlation Between the Density of the Hydrometer Method and Fly Ash Fineness in Acceptance Inspection (인수검사시 Hydrometer법의 밀도 값과 플라이애시의 분말도간 상관관계 분석)

  • Moon, Byeong-Yong;Hyun, Seong-Yong;Lee, Jae-Jin;Song, Heung-Ho;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.20-21
    • /
    • 2017
  • There have been reports in the media about some refineries that omit the refining process and deliver raw material for reasons of cost reduction, shortening of production time, etc. Also, in most RMC factories acceptance inspection is not conducted on account of issues with the proficiency of the equipment and cost issues; instead only scores are relied upon. Therefore this study sought to analyze the relation between the value of the density of FA actually delivered to RMC companies, attained with the Hydrometer method, and its fineness, to see whether the quality of FA can be evaluated statistically. Results led to the conclusion that there is a problem in terms of credibility in the fineness of FA shown on the test report. Upon analyzing the difference between the fineness of FA as measured using Blaine's air permeability method and its density of the Hydrometer method, the correlation was found to be satisfactory; therefore the possibility of a FA fineness quality evaluation could be proved as well.

  • PDF

An Analysis of Important Factors for Energy Efficient Healthcare Facilities on Experts' Survey (전문가 설문조사를 통한 에너지 효율적인 병원시설을 위한 중요한 영향요소의 분석)

  • Choi, Yeo-Jin;Choi, Yool
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.45-50
    • /
    • 2017
  • Purpose: There have been more researches focused on eco-friendly construction practices in order to save energy consumed and these practices have been extensively applied for constructing buildings. However, researches on energy consumption saving and efficiency for hospital facilities have been still insufficient. This research aims to draw factors that affect energy efficiency of hospital buildings through literature reviews and perform an expert-survey using AHP(Analytical Hierarchy Process) method in order to analyze the importances and priorities of these energy efficient factors. Method: Using the AHP method, this paper suggests the importances and priorities of factors to affect energy efficiency in hospital buildings. The survey of experts at a architectural design and a construction management companies was conducted via e-mail and mail. Result: As a result, factors of window and door, insulation, ventilation, and natural lighting turned out relatively important as respectively 0.104, 0.102, 0.101, and 0.095 n the energy efficiency in hospital buildings, while factors of artificial lighting, geothermal, solar heat, and control did unimportant as 0.027, 0.033, 0.043, and 0.053.

Delivering IPTV Service over a Virtual Network: A Study on Virtual Network Topology

  • Song, Biao;Hassan, Mohammad Mehedi;Huh, Eui-Nam
    • Journal of Communications and Networks
    • /
    • v.14 no.3
    • /
    • pp.319-335
    • /
    • 2012
  • In this study, we design an applicable model enabling internet protocol television (IPTV) service providers to use a virtual network (VN) for IPTV service delivery. The model addresses the guaranteed service delivery, cost effectiveness, flexible control, and scalable network infrastructure limitations of backbone or IP overlay-based content networks. There are two major challenges involved in this research: i) The design of an efficient, cost effective, and reliable virtual network topology (VNT) for IPTV service delivery and the handling of a VN allocation failure by infrastructure providers (InPs) and ii) the proper approach to reduce the cost of VNT recontruction and reallocation caused by VNT allocation failure. Therefore, in this study, we design a more reliable virtual network topology for solving a single virtual node, virtual link, or video server failure. We develop a novel optimization objective and an efficient VN construction algorithm for building the proposed topology. In addition, we address the VN allocation failure problem by proposing VNT decomposition and reconstruction algorithms. Various simulations are conducted to verify the effectiveness of the proposed VNT, as well as that of the associated construction, decomposition, and reconstruction algorithms in terms of reliability and efficiency. The simulation results are compared with the findings of existing works, and an improvement in performance is observed.

Development of the Flexible Observation System for a Virtual Reality Excavator Using the Head Tracking System (헤드 트래킹 시스템을 이용한 가상 굴삭기의 편의 관측 시스템 개발)

  • Le, Q.H.;Jeong, Y.M.;Nguyen, C.T.;Yang, S.Y.
    • Journal of Drive and Control
    • /
    • v.12 no.2
    • /
    • pp.27-33
    • /
    • 2015
  • Excavators are versatile earthmoving equipment that are used in civil engineering, hydraulic engineering, grading and landscaping, pipeline construction and mining. Effective operator training is essential to ensure safe and efficient operating of the machine. The virtual reality excavator based on simulation using conventional large size monitors is limited by the inability to provide a realistic real world training experience. We proposed a flexible observation method with a head tracking system to improve user feeling and sensation when operating a virtual reality excavator. First, an excavation simulator is designed by combining an excavator SimMechanics model and the virtual world. Second, a head mounted display (HMD) device is presented to replace the cumbersome large screens. Moreover, an Inertial Measurement Unit (IMU) sensor is mounted to the HMD for tracking the movement of the operator's head. These signals consequently change the virtual viewpoint of the virtual reality excavator. Simulation results were used to analyze the performance of the proposed system.

Study on the Profile of Nut Bearing Surface and the Torque Coefficient of a High Strength Bolt Set (고장력 볼트세트의 자리면형상과 토크계수에 관한 연구)

  • Lee, Baek Joon;Sohn, Seung Yo
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.2 s.45
    • /
    • pp.143-150
    • /
    • 2000
  • Depending upon the combination of tolerances specified in the standards on bolt, nut and washer for high tension bolt sets, there arises center-to-center deviation between bolt and washer. This deviation nay cause loss of effective contact area between nut- and washer-faces, which leads to some dispersion of the torque coefficient K. By adapting circular arc surface instead of flat surface for the nut, it is shown through numerical analyses that the dispersion of the torque coefficient can be minimized. In this way, optimum radius of curvature of the nut bearing surface is proposed.

  • PDF