Sensorless Passivity Based Control of a DC Motor via a Solar Powered Sepic Converter-Full Bridge Combination

  • Linares-Flores, Jesus;Sira-Ramirez, Hebertt;Cuevas-Lopez, Edel F.;Contreras-Ordaz, Marco A.
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.743-750
    • /
    • 2011
  • This article deals with the sensor-less control of a DC Motor via a SEPIC Converter-Full Bridge combination powered through solar panels. We simultaneously regulate, both, the output voltage of the SEPIC-converter to a value larger than the solar panel output voltage, and the shaft angular velocity, in any of the turning senses, so that it tracks a pre-specified constant reference. The main result of our proposed control scheme is an efficient linear controller obtained via Lyapunov. This controller is based on measurements of the converter currents and voltages, and the DC motor armature current. The control law is derived using an exact stabilization error dynamics model, from which a static linear passive feedback control law is derived. All values of the constant references are parameterized in terms of the equilibrium point of the multivariable system: the SEPIC converter desired output voltage, the solar panel output voltage at its Maximun Power Point (MPP), and the DC motor desired constant angular velocity. The switched control realization of the designed average continuous feedback control law is accomplished by means of a, discrete-valued, Pulse Width Modulation (PWM). Experimental results are presented demonstrating the viability of our proposal.

Measurement of Normal Spring Constant of Colloidal Probes for Atomic Force Microscope (원자 현미경용 콜로이드 탐침 수직 스프링 상수 측정)

  • Kim, Dae-Hyun;Kim, Min-Seok;Hahn, Junhee;Ahn, Hyo-Sok
    • Tribology and Lubricants
    • /
    • v.28 no.5
    • /
    • pp.212-217
    • /
    • 2012
  • A modified thermal noise method was proposed to measure the normal spring constants of the colloidal probes for an atomic force microscope. We used commercial tipless cantilevers (length 150, width 30, nominal k 7.4 N/m) and borosilicate spheres with a diameter of 20 to fabricate colloidal probes. The inverse optical lever sensitivity of both the tipless cantilever and colloidal probes were used to measure the normal spring constant of the colloidal probes. We confirmed the accuracy and usefulness of our method by comparing the measurement results with those obtained using the nanoforce calibrator (NFC), which reportedly has an uncertainty of 1.00%. The modified thermal method showed a good agreement (~10% difference) with the NFC, allowing us to conclude that the modified thermal method could be employed for the effective measurement of the normal spring constants of colloidal probes.

Design of LLCL Filter for Single Phase Inverters with Confined Band Variable Switching Frequency (CB-VSF) PWM

  • Attia, Hussain A.;Freddy, Tan Kheng Suan;Che, Hang Seng;El Khateb, Ahmad H.
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.44-57
    • /
    • 2019
  • Recently, the use of LLCL filters for grid inverters has been suggested to give better harmonic attenuation than the commonly used L and LCL filters, particularly around the switching frequency. Nevertheless, this filter is mainly designed for constant switching frequency pulse width modulation (CSF PWM) methods. In variable switching frequency PWM (VSF PWM), the harmonic components are distributed across a wide frequency band which complicates the use of a high order filter, including LCL and LLCL filters. Recently, a confined band variable switching frequency (CB-VSF) PWM method has been proposed and demonstrated to be superior to the conventional constant switching frequency (CSF) PWM in terms of switching losses. However, the applicability of LLCL filters for this type of CB-VSF PWM has not been discussed. In this paper, the authors study the suitability of an LLCL filter for CB-VSF PWM and propose design guidelines for the filter parameters. Using simulation and experimental results, it is demonstrated that the effectiveness of an LLCL filter with CB-VSF PWM depends on the parameters of the filters as well as the designed variable frequency band of the PWM. Simulation results confirm the performance of the suggested LLCL design, which is further validated using a lab scale prototype.

An Experimental Study on the Dowel Action in Reinforced Concrete Members(II) (철근 콘크리트 부재의 장부작용에 관한 실험적 연구 (II))

  • 김성훈;신장호;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.59-64
    • /
    • 1994
  • Following the previous research(7), a total of forty six specimens were tested to scrutinize the dowel action of reinforcing bars. Concrete cover, width of specimen and reinforcing bar size were taken as main test variables for constant compressive strength of concrete, based on the observation of the test results, the characteristic effects of the test variables on the dowel strength have been analyzed.

  • PDF

Operational Properties of Ridge Waveguide Lasers with Laterally Tapered Waveguides for Monolithic Integration

  • Kwon, Oh-Kee;Kim, Ki-Soo;Sim, Jae-Sik;Baek, Yong-Soon
    • ETRI Journal
    • /
    • v.29 no.6
    • /
    • pp.811-813
    • /
    • 2007
  • We report on a ridge waveguide laser diode with laterally tapered waveguides fabricated in a single growing step using a double patterning method. In this structure, nearly constant output power is obtained with the change of the lower tapered waveguide width, and the facet power ratio of 1.4 to 1.5 is observed over the current range. The asymmetric facet power property is also investigated.

  • PDF

Characteristics of UHF Antenna with microstrip structure (UHF 대역용 마이크로 스트립 안테나 특성)

  • Park, Yong-Wook
    • Journal of the Korea Computer Industry Society
    • /
    • v.9 no.5
    • /
    • pp.217-222
    • /
    • 2008
  • The characteristics of UHF antenna with microstrip structure was studied. Design parameters as center frequency, band width, and VSWR by slot length, stub was analyzed by HFSS simulator. UHF antenna with microstrip structure was fabricated using FR4_epoxy substrate of 4.4 dielectric constant.

  • PDF

Tension Control System for Hot Strip Mills (열간 압연 공정에서의 장력 제어시스템)

  • 박성한;안병준;황이철;홍신표;이만형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.169-169
    • /
    • 2000
  • The modeling for the looper of a hot strip finishing mill to control the tension of the strip is presented. The looper is an arm pushing against the strip between stands in a tandem mill to keep the strip tension constant and to isolate the interactions of the adjacent stands. Tension is influenced by the difference in mass flow through the up stream and down-stream rolling stands. Tension is critical to strip quality, influencing width, gauge, and shape. This paper presents how looper angle and strip tension are controlled for a hot strip finishing mill.

  • PDF

Sequential Estimation of variable width confidence interval for the mean

  • Kim, Sung Lai
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.14 no.2
    • /
    • pp.47-54
    • /
    • 2001
  • Let {Xn, n = 1,2,${\cdots}$} be i.i.d. random variables with the only unknown parameters mean ${\mu}$ and variance a ${\sigma}^2$. We consider a sequential confidence interval C1 for the mean with coverage probability 1-${\alpha}$ and expected length of confidence interval $E_{\theta}$(Length of CI)/${\mid}{\mu}{\mid}{\leq}k$ (k : constant) and give some asymptotic properties of the stopping time in various limiting situations.

  • PDF

Influence of Fertilizer Levels and Cultivated Regions on Morphological Characteristics of Rice Grains (시비수준(施肥水準) 및 재배지역(栽培地域)이 쌀의 형태적(形態的) 특성(特性)에 미치는 영향(影響))

  • Hong, Young-Pyo;Kim, Seong-Yeol;Im, Jeong-Nam
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.2
    • /
    • pp.85-92
    • /
    • 1993
  • This study was investigated on the morphological characteristics of rice grain as affected by three fertilizer application treatments. Of no-nitrogen, optimum nitrogen, and heavy nitrogen without potassium in three regions of Suweon (Mid-West Plain Zone), Ichon(Mid-Inland Plain Zone), and Kyehwado(South-charyung Mts. Plain Zone) with four varieties, i.e., three Tonsil types(Geumgangbyeo, Milyang 23, and Chilseongbyeo) and one japonica type(Chucheongbyeo, Akibare in Japanese name). The results obtained were as follows: The increase of nitrogen application caused an increase of grain length in rough rice and grain width in milled rice, resulting in a decrease of the width/thickness ratio in milled rice. The width and thickness of rice grain produced in Kyehwado were smaller than those in the other regions. Therefore, the ratio of length/width and length/thickness in rice grain produced in Kyehwado was larger. The one thousand grain weight of rice was heavier at the optimum nitrogen level than at the no-nitrogen and heavy nitrogen without potassium treatment levels. The weight percentage of hull in rough rice grain decreased in accordance with the increase of nitrogen application, while the weight percentage of bran in brown rice was constant. This suggested that for the normal development of rice grain a constant ratio of bran is needed. The morphological change of rice grain by fertilizer treatments and the change of region cultivated could not be distinguished from the native characteristics of the variety. Other grain characteristics were discussed in view of treatment and regional effects.

  • PDF

Effects of vertical head rotation on the posteroanterior cephalometric measurements (정모두부방사선사진 촬영시 두부의 수직회전에 따른 투사오차)

  • Koh, Eun-Hee;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.73-84
    • /
    • 2003
  • This study was performed to find out how much projection errors in the cephalometric measurements were made by vertical head rotation in taking posteroanterior cephalograms. 25 adults without any apparent facial asymmetry or severe sagittal skeletal discrepancy were selected and the posteroanterior cephalograms were taken with the head rotated $5^{\circ},\;10^{\circ}$ superior and inferior each to the reference $position(0^{\circ})$. The 7 height, 5 width and 6 angular measurements were taken at each 5 positions. Through the statistical analysis of all measurements taken at each rotated position, folowing results were obtained.1. The projection errors of height measurements were remarkably target than those of width or angular measure nents. f. Among the height measurements, the farther to the rotation axis the measurements were, the larger the projection errors were. 3. Among the width measurements, mandibular width and mandibular width of mandibular first molars showed significant differences between the values taken at each rotated position, while nasal width, maxillary width and intermolar width of maxillary first molars did not. 4. Among the angular measurements, the angle between horizontal reference line and the line that is connected to crista galli and antegonion or maxillare showed significant differences between the values taken at each rotated Position. The above results suggest that it is needed to the effort to keep constant head position for taking the useful posteroanterior cephalogra, because projection errors are caused by vertical head rotation.