• 제목/요약/키워드: constant power

검색결과 2,851건 처리시간 0.076초

Estimating Stability of MTDC Systems with Different Control Strategy

  • Nguyen, Thai-Thanh;Son, Ho-Ik;Kim, Hak-Man
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.443-451
    • /
    • 2015
  • The stability of a multi-terminal direct current (MTDC) system is often influenced by its control strategy. To improve the stability of the MTDC system, the control strategy of the MTDC system must be appropriately adopted. This paper deals with estimating stability of a MTDC system based on the line-commutated converter based high voltage direct current (LCC HVDC) system with an inverter with constant extinction angle (CEA) control or a rectifier with constant ignition angle (CIA) control. In order to evaluate effects of two control strategies on stability, a MTDC system is tested on two conditions: initialization and changing DC power transfer. In order to compare the stability effects of the MTDC system according to each control strategy, a mathematical MTDC model is analyzed in frequency domain and time domain. In addition, Bode stability criterion and transient response are carried out to estimate its stability.

Characteristics of Sparkover Discharge In Flowing Air With Variation of Temperature (온도변화를 고려한 유동공기의 방전특성에 관한 연구)

  • 김상구;오재열;송현직;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 1991년도 추계학술발표회논문집
    • /
    • pp.28-32
    • /
    • 1991
  • This paper reports the characteristics of sparkover discharge in flowing air with variation of Temperature(T). Also, We studied changes of discharge pattern for constant input power by adjustment of the reynolds number(Re) and T. the essentials of this paper are as followers. The invaluable equation obtained from this experiment is [%] {{{{ { Vs} over {Re } = A·LOG10 Re + B}}}} w here A,B : constant Breakdown Voltage for variation of temperature at 1[m/s] is given by expression Vs = K(23.98 pd + 6.8{{{{ SQRT { pd} }}}}) [kV] where K = 0.331 The discharge pattern can be controlled by adjustment of the Reynolds number

  • PDF

Sensorless Speed Control for Brushless DC Motor using Digital IP Controller (디지털 IP 제어기를 이용한 브러시리스 직류 전동기의 센서리스 속도제어)

  • Kim Jong-Sun;Park Hyong-Joon;Jang Jae-Hoon;Yoo Ji-Yoon;Seo Sam-Jun
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.289-293
    • /
    • 2004
  • The sensorless speed control technique for BLDCM using digital IP control is proposed in this paper for advanced speed characteristic which is robust for loads. The sensorless drive of BLDCM using terminal voltages is affected by load or speed because it uses analog filters to estimate the rotor position. For this reason, the robust speed controller with the accurate rotor position estimator is needed for sensorless control which is robust to load and insensitive to motor parameters. The constant speeds robust to load variation and the stable sensorless control of BLDCM robust to the increase or decrease of speed with constant load are implemented using digital IP control in this paper. The validity to these is established with experimentation.

  • PDF

Average Current Controlled X-Y Channel Driving White LED Backlight System for 46" LCD TV

  • Cho, Dae-Youn;Oh, Won-Sik;Cho, Kyu-Min;Moon, Gun-Woo;Yang, Byung-Choon;Jang, Tae-Seok
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.271-273
    • /
    • 2008
  • A novel white-LED (light emitting diode) backlight system for 46"LCD TVs which involves the average current controlled X-Y channel driving method is proposed, which is composed of 1 converter and row and column channel switches. In the conventional X-Y channel driving driven with a constant voltage source, the driving current of LED increases because the threshold voltage of LED decreases when LED temperature goes up. To maintain the luminance of backlight constant, the average current controlled X-Y channel driving will be employed. Finally the results are confirmed by experimental results.

  • PDF

Perfonnance Analysis of Binary CDMA systems in Multi-Path Fading Channel (다중경로 페이딩 환경에서의 바이너리 CDMA 시스템 성능 분석)

  • Ko Jae-Yun;Lee Yong-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제30권9A호
    • /
    • pp.795-802
    • /
    • 2005
  • Binary CDMA(B-CDMA) is a new modulation scheme that employs a constant envelope modulation scheme By quantizing the envelope of multi-codes CDMA signal into a small number of levels, the B-CDMA can reduce the peak-to-average power ratio, while preserving the advantages of CDMA signaling such as the soft capacity and robustness to interference. In this paper, we analyze the performance of B-CDMA systems in multi-path channel assuming that the spreading factor is not too small. Finally, the analytic results are verified by computer simulation.

A Study on the 2nd exitation method for CVCF Generation of doubly-fed induction Generator (권선형 유도 발전기 CVCF 발전을 위한 2차 여자 제어법에 관한 연구)

  • Ahn, Jin-Woo;Kim, Chul-Woo;Hwang, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.341-344
    • /
    • 1988
  • This paper derives a condition foe constant voltage i constant frequency generation of doubly-fed induction generator. The condition is varied by the magnitude of output voltage, load current and its power factor, slip of the machine. Magnitude of output voltage is controlled by exiting voltage which is caculated by derived equation from operating condition. frequency of output voltage is controlled by injecting slip frequency to the rotor which is the difference between wanted output frequency and rotor frequency.

  • PDF

Transient Response Characteristic of a Linear Actuator in a Spring Stiffness Variations (공진형 선형 액추에이터의 스프링 강성 변화에 따른 과도응답특성)

  • Kang Do-Hyun;Hong Do-Kwan;Woo Byung-Chul
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제54권3호
    • /
    • pp.134-138
    • /
    • 2005
  • A typical conventional systems of a linear motion use rack and pinions or ball screws to convert rotary motions from DC servo motors. A linear motor has been used a several field for a MEMS technology and a aircraft carrier. We have studied a transient response of a linear actuator with a damping ratio, spring constant and a pressed power for a constant stroke control.

Design of off-line UPS with AVR (AVR 기능 부가 off-line UPS 설계)

  • Lee, Seung-Hee;Park, Tae-Jun;Lee, Jin-Hee;Lee, Wang-Ha;Lee, Chi-Wan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.605-607
    • /
    • 2001
  • In this paper, an off-tine UPS with CVT(constant voltage transformer) is designed and the experimental result and problems of the designed UPS is given and discussed. This off-line UPS consists of triple-port CVT and PWM inverter which acts as charger and inverter. It can be evaluated in low price because haying simple structure. It offers high performance because CVT restricts the short current automatically about two or three times of rated current, has nearly unit power factor and constant output voltage to varying input voltage. The weak points of this UPS are that the output voltage waveform is not perfect sinusoidal and has phase difference to input voltage. The experimental result and problems of the designed UPS is given.

  • PDF

Performance Improvement of Stepping Motor Driver (2상 스테핑 모터 드라이버의 성능개선)

  • Kim, Il-Hwan;Oh, Tae-Seok
    • Journal of Industrial Technology
    • /
    • 제24권A호
    • /
    • pp.91-97
    • /
    • 2004
  • This paper describes the design of a 2-phase stepping motor driver using CPLD(Complex Programmable Logic Device). The driver IC such as L297(SGS-Thomson Microelectronics), which is mostly used has some difficulties in PWM control because of the switching noise of power MOSFETs. It causes current ripple and acoustic noise. To improve theses characteristics, we proposed a new current control method that the output PWM frequency is almost constant using a digital filter. Also we proposed constant current method for 1-2 phase(half step) excitation. The proposed method is implemented with CPLD(Xilinx, XC9572-PC44). Experimental results show the effectiveness of the proposed method.

  • PDF

Electromagnetothermoelastic behavior of a rotating imperfect hybrid functionally graded hollow cylinder

  • Saadatfar, M.;Aghaie-Khafri, M.
    • Smart Structures and Systems
    • /
    • 제15권6호
    • /
    • pp.1411-1437
    • /
    • 2015
  • The electro-magneto- thermo-elastic behavior of a rotating functionally graded long hollow cylinder with functionally graded piezoelectric (FGPM) layers is analytically analyzed. The layers are imperfectly bonded to its inner and outer surfaces. The hybrid cylinder is placed in a constant magnetic field subjected to a thermo-electro-mechanical loading and could be rested on a Winkler-type elastic foundation. The material properties of the FGM cylinder and radially polarized FGPM layers are assumed to be graded in the radial direction according to the power law. The hybrid cylinder is rotating about its axis at a constant angular velocity. The governing equations are solved analytically and then stresses, displacement and electric potential distribution are calculated. Numerical examples are given to illustrate the effects of material in-homogeneity, magnetic field, elastic foundation, applied voltage, imperfect interface and thermo-mechanical boundary condition on the static behavior of a FG smart cylinder.