• 제목/요약/키워드: constant power

Search Result 2,851, Processing Time 0.032 seconds

DESIGN OF A HIGH-SPEED HIGH-POWER SWITCHED RELUCTANCE MOTOR

  • Jacket F. Gieras;Park, Jaeho
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.19-25
    • /
    • 2001
  • A high speed, three phase, 12/8 pole, 225 kW switched reluctance motor (SRM) has been designed and analyzed. A circuital approach has been used to find the geometry, windings parameters and electromagnetic loading. Then, the 3D finite element method (FEM) has been used to calculate the static torque more accurately and optimize the design. The efficiency of the designed SRM is almost constant over wide range of speed and its phase current is less sensitive to the speed than that of an induction motor of the same rating. Recommendations for manufacturers and users are given.

  • PDF

Voltage Amplitude Control of DC Power Regenerating Inverters with $\alpha$-Conduction Mode ($\alpha$도통모드에 의한 직류전력회생용 인버터 출력전압의 크기 제어)

  • 이주훈
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.351-354
    • /
    • 2000
  • This paper deals with the voltage amplitude control in inverter systems which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. To maintain the magnitude of output fundamental voltage constant in spite of the variation of input DC voltage inverters are operated in symmetrical $\alpha$-conduction mode with the range of $120^{\circ}$<$\alpha$<$180^{\circ}$ To match the output voltage of the inverter systems with AC supply voltage harmonic reduction techniques are also investigated. Computer simulations are carried out to verify the validity of the proposed systems.

  • PDF

AC and DC Applications of Induction Generator Excited by Static VAR Compensator

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.169-179
    • /
    • 2004
  • This paper presents the steady-state analysis of the three-phase self-excited induction generator (SEIG). The three-phase SEIG with a squirrel cage rotor is driven by a variable-speed prime mover (VSPM) or a constant-speed prime mover (CSPM) such as a wind turbine or a micro gas turbine. Furthermore, a PI closed-loop feedback voltage regulation scheme of the three-phase SEIG driven by a VSPM on the basis of the static VAR compensator (SVC) is designed and evaluated for the stand-alone AC and DC power applications. The simulation and experimental results prove the practical effectiveness of the additional SVC with the PI controller-based feedback loop in terms of its fast responses and high performances

Investigation of Capacitor Voltage Regulation in Modular Multilevel Converters with Staircase Modulation

  • Shen, Ke;Wang, Jianze;Zhao, Dan;Ban, Mingfei;Ji, Yanchao;Cai, Xingguo
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.282-291
    • /
    • 2014
  • This paper presents a detailed theoretical analysis and performance assessment of the capacitor voltage balancing strategies for staircase modulated modular multilevel converters (MMC) in terms of the algorithm structures, voltage balancing effect, and switching frequency. A constant-frequency redundancy selection (CFRS) method with minimal switching loss is proposed and the function realization of specific modules of the algorithm is given. This method is simple and efficient in both switching frequency and regulation capacity. Laboratory results show very good agreement with the theoretical analysis and numerical simulations.

Battery Energy Storage Based Voltage and Frequency Controller for Isolated Pico Hydro Systems

  • Singh, Bhim;Rajagopal, V.
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.874-883
    • /
    • 2009
  • This paper deals with an integrated voltage and frequency (VF) controller for isolated asynchronous generators (IAG) driven by a constant power pico-hydro uncontrolled turbine feeding three-phase four-wire loads. The proposed VF controller is used to control the frequency and voltage of an IAG with load leveling. Such a VF controller is also known as an integrated electronic load controller (IELC) which is realized using an isolated star/polygon transformer with a voltage source converter (VSC) and a battery at its DC bus. The proposed generating system with a VFC is modeled and simulated in MATLAB along with Simulink and Simpower system (SPS) toolboxes. The simulated results are presented to demonstrate the performance of an isolated asynchronous generator feeding three-phase four-wire loads with neutral current compensation.

NEW GROUP OF ZVS PWM CONVERTERS OPERABLE ON CONSTANT FREQUENCY AND ITS APPLICATION TO POWER FACTOR CORRECTION CIRCUIT (일정 주파수로 동작이 가능한 ZVS PWM 컨버터와 역률개선 회로에의 응용)

  • Huh, Dong-Y.;Kim, Hack-S.;Cho, Gyu-H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.988-991
    • /
    • 1992
  • A new zero voltage switching PWN converter family is presented by using a new ZVS PWN module (ZPM) with a saturable inductor which prevents diode junction capacitors and a commutation inductor from resonating. The new converters show almost all characteristics of the conventional PWN converters. A boost ZVS PWN converter is applied to a power factor correction circuit. It operates on an continuous conduction mode. Experimental results for output power of 1kW are presented.

  • PDF

Water Absorption Sensor of Generator Stator Bar Insulation using Cross Capacitance (크로스 커패시턴스를 이용한 발전기 고정자 권선 절연물 흡습 측정 센서)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Doo-Young;Lee, Wook-Ryun;Lee, Rae-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1972-1977
    • /
    • 2011
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. To cool down the heat emitted from generator winding during its operation, a majority of generators use de-mineralized water characterized by high cooling efficiency. Contrary to such the excellent cooling efficiency, however, the damaged bar insulations attributed to the absorption of cooling water in the generator stator winding lead to highly time- and cost consuming efforts as well as to service deterioration due to unexpected forced outage of generator. It is described that the new design of water absorption sensor using cross capacitance for generator in power plant in order to increase the reliability of water absorption diagnostics for generator stator bar insulation.

Grid-tied Power Converter for Battery Energy Storage Composed of 2-stage DC-DC Converter

  • Kim, Do-Hyun;Lee, Yoon-Seok;Han, Byung-Moon;Kim, Ju-Yong;Chae, Woo-Kyu
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1400-1408
    • /
    • 2013
  • This paper proposes a new grid-tied power converter for battery energy storage, which is composed of a 2-stage DC-DC converter and a PWM inverter. The 2-stage DC-DC converter is composed of an LLC resonant converter connected in cascade with a 2-quadrant hybrid-switching chopper. The LLC resonant converter operates in constant duty ratio, while the 2-quadrant hybrid-switching chopper operates in variable duty ratio for voltage regulation. The operation of proposed system was verified through computer simulations. Based on computer simulations, a hardware prototype was built and tested to confirm the technical feasibility of proposed system. The proposed system could have relatively higher efficiency and smaller size than the existing system.

Load distribution analysis of a sprocket wheel tooth for a low head hydro-turbine power transmission system (저낙차용 수차의 동력전달 스프로켓 휠 이의 하중분포 해석)

  • 강용석;김현수;김현진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1087-1095
    • /
    • 1994
  • Chain drive power transmission system was developed for a low head hydro-turbine which generates power by energy transformation on the turbine blades attached to chains. Also, experimental and theoretical analysis for the sprocket wheel tooth load distribution were performed. The tooth load was measured by the specially designed load sensor. It was found that the tooth load distribution for the steady state operation was in good accordance with the quasi-static state results showing the peak load at the final meshing tooth. The trend of the experimental results agreed with the theoretical results based on the spring model analysis and difference in the magnitude of the maximum tooth load was considered to be the effect of the variable spring constant due to the moving contact point between the roller and sprocket wheel tooth.

The maximum power condition of the Brayton cycle with heat exchange processes (熱交換 過程 을 考慮한 브레이튼 사이클 의 最大出力條件)

  • 정평석;차진걸;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.6
    • /
    • pp.795-800
    • /
    • 1985
  • The ideal Brayton cycle has been analyzed with the heat exchange processes between the working fluid and the heat source and the sink while their heat capacity rates are constant. The power fo the cycle can be expressed in terms of a temperature of the cycle and the heat capacity rate of the working fluid. There exists an optimum power condition where the heat capacity rate of the working fluid has a value between those of the heat source and the heat sink, and the cycle efficiency is determined by the inlet temperatures of the heat source and the sink.