• Title/Summary/Keyword: constant power

Search Result 2,851, Processing Time 0.033 seconds

A Study on the determination of the potassium supplying power of paddy soils by $^{40}K$ application ($^{40}K$을 이용(利用)한 답토양(畓土壤)의 가리(加里) 공급력(供給力) 측정법 연구(測定法 硏究))

  • Kim, Tai-Soon
    • Applied Biological Chemistry
    • /
    • v.15 no.2
    • /
    • pp.143-162
    • /
    • 1972
  • Based on the concentration of $^{40}K$ naturally occurring radioisotope of potassium, a method for the determination of total potassium in soils and plants was developed. The method was extended to evaluate the potassium supplying power of soils by taking the ratio of exchangeable potassium to total potassium $(K_{ex}/K_t)$, termed the potassium buffering capacity. Using this as index, it was observed that the release of potassium from soil fellows the from order reaction. A linear relationship was found between the potassium buffering capacity and the release constant of potassium or mica content of the clay. Similarly the potassium buffering capacity was also closely correlated with total uptake of potassium by rice plant. Hence it is concluded that the method for determining of the potassium buffering capacity could be veil applied to characterize the potassium availability of soils. The method for the determination of potassium is characterized by (1) The efficient measurement of the weak beta activity emissions from the samples, (2) identification of $^{40}K$, (3) calculation of total potassium content using the proportional constant of $^{40}K$ of samples to that of the standard. Difference in the potassium supplying power of soils due to soil types was also evaluated with the use of this technique. The degree of the potassium supplying power was in the order of soil types as red-yellow podzolic and lateric soils, basaltic materials(Rvd)> low-humic gley and alluvial soils, alluvial plains and food plains(Apa)> low-humic gley soils, nearly level to sloping local alluvial plains and slopes(Afb)> low-humic gley and alluvial soils, fluvio-marine plains (Fma).

  • PDF

Control and Operating Modes of Battery Energy Storage System for a Stand-Alone Microgrid with Diesel Generator (디젤발전기가 포함된 독립형 마이크로그리드에서의 BESS 제어기법 및 운전모드 연구)

  • Jo, Jongmin;An, Hyunsung;Kim, Jichan;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.86-93
    • /
    • 2018
  • In this work, control methods and operating modes are proposed to manage standalone microgrid. A standalone microgrid generally consists of two sources, namely, battery energy storage system (BESS) and diesel generator (DG). BESS is the main source that supplies active and reactive power regardless of load conditions, whereas DG functions as an auxiliary power source. BESS operates in a constant voltage constant frequency (CVCF) control, which includes proportional-integral + resonant controller in a parallel structure. In CVCF control, the concept of fundamental positive and negative transformation is utilized to generate a three-phase sinusoidal voltage under imbalanced load condition. Operation modes of a standalone microgrid are divided into three modes, namely, normal, charge, and manual modes. To verify the standalone microgrid along with the proposed control methods, a demonstration site is constructed, which contains 115 kWh lead-acid battery bank, 50 kVA three-phase DC - AC inverter, and 50 kVA DG and controllable loads. In the CVCF control, the total harmonic distortion of output voltage is improved to 1.1% under imbalanced load. This work verifies that the standalone microgrid provides high-quality voltage, and three operation modes are performed from the experimental results.

The Direct TM01-TE11 Mode Converter Using Circular Waveguide for High Power Applications (원형 도파관을 이용한 초고출력용 TM01-TE11 직접 모드 변환기)

  • Lee Byoung-Moo;Lee Sang-Heun;Yoon Young-Joong;Yang Gi-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.351-357
    • /
    • 2006
  • In this paper, a direct $TM_{01}-TE_{11}$ mode converter of circular waveguide which is used the approximated design method of mode conversion between $TM_{01}$ and $TE_{11}$ modes is designed for radiation with the maximum directivity of high power energy into air (rom high power microwave antenna system. The proposed direct $TM_{01}-TE_{11}$ mode converter is calculated and designed with an approximated method for non-linear function about an extended non-constant serpentine type of circular waveguide. Then, the designed mode converter is optimized by length of 200 mm and efficiency above 95% by FIM simulation and achieved short length and high efficiency of the antenna by results of fabricated and measured characteristics.

Development of DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle (하이브리드 자동차 보조전원 공급용 DC-DC 컨버터 개발)

  • Kim, Jong-Cheol;Choi, Deok-Kwan;Park, Hae-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.261-265
    • /
    • 2005
  • This paper describes the DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle. DC-DC Converter is used for charging 12V auxiliary battery supplying electric power to head ramp, audio, ECU etc in automobiles. used DC-DC Converter Topology is PS-ZVS FB(Phase Shifted Zero Voltage Switching Full-Bridge) to reduce switching loss and EMI noise induced by high frequency operating condition. And For easy compensation and stable system response characteristic, current mode control method including slope compensation is employed. Constant current / constant voltage charging control method guarantee stable electric charging of auxiliary battery. Simulation toll PSIM6.0 is used for initial circuit parameter settings and H/W debuging. Thermal problems of Switching components in DC-DC Converter is improved by using Thermo Tracer.

  • PDF

Series Load Resonant High Frequency Inverter with ZCS-PDM Control Scheme for Induction-Heated Fusing Roller

  • Sugimura, Hisayuki;Kwen, Soon-Kurl;Koh, Kang-Hoon;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.415-420
    • /
    • 2005
  • This paper presents the two lossless auxiliary inductors-assisted voltage source type half bridge (single ended push pull: SEPP) series resonant high frequency inverter for induction heated king roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimental ones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proved from the practical point of view.

  • PDF

Harmonics Control of Electric Propulsion System using Direct Torque Control (직접벡터제어방식을 사용하는 전기추진시스템의 고조파 제어)

  • Kim, Jong-Su;Oh, Sae-Gin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2618-2624
    • /
    • 2009
  • Harmonics (or distortion in wave form) has always existed in electrical power systems. It is harmless as long as its level is not substantial. However, with the recent rapid advancement of power electronics technology, so-called nonlinear loads, such as variable frequency drives for motor power/speed control, are increasingly finding their way to shipboard or offshore applications. In this paper a new approach to direct torque control (DTC) of induction motor drive is presented. In comparison with the conventional DTC methods the inverter switching frequency is constant and is dramatically increased, requiring neither any increase of the sampling frequency, nor any high frequency dither signal. The well-developed space vector modulation technique is applied to inverter control in the proposed DTC-based induction motor drive system, thereby dramatically reducing the current harmonics. As compared to the existing DTC approach with constant inverter switching frequency, the presented new approach does not invoke any concept of deadbeat control, thereby dramatically reducing the computations.

Electrical/Mechanical Diagnosis of Local Deterioration in 600V Shielded Twist Pair Cable in a Nuclear Power Plant (원전용 600V 차폐 꼬임쌍선 케이블의 국부열화에 대한 전기적/기계적 진단)

  • Park, Myeongkoo;Kim, Kwangho;Lim, Chanwoo;Kim, TaeYoon;Kim, Hyunsu;Chai, Jangbom;Kim, Byungsung;Nah, Wansoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.203-210
    • /
    • 2017
  • In this paper, we propose a electrical/mechanical method to effectively diagnose the local deterioration of a 10m long power shielded twist pair cable defined by the American Wire Gauge (AWG) 14 specification using electrical/mechanical methods. The rapid deterioration of the cable proceeded by using the heating furnace, which is based on the Arrhenius equations proceeds from 0 to 35 years with the deteriorated equivalent model. In this paper, we introduce a method to diagnose the characteristics of locally deteriorated cable by using $S_{21}$ phase and frequency change rate measured by vector network analyzer which is the electrical diagnostic method. The measured $S_{21}$ phase and rate of change of frequency show a constant correlation with the number of years of locally deteriorated cable, thus it can be useful for diagnosing deteriorated cables. The change of modulus due to deterioration was measured by a modulus measuring device, which is defined by the ratio of deformation from the force externally applied to the cable, and the rate of modulus change also shows a constant correlation with the number of years of locally deteriorated cable. Finally, By combining the advantages of electrical/mechanical diagnostic methods, we can efficiently diagnose the local deterioration in the power shielded cable.

Analysis of Electromagnetic Wave Characteristics of Microwave Nondestructive Device for Inspecting Human Lower Leg (마이크로파 비파괴 검사를 위한 인체 하지에 대한 전자파특성 분석)

  • Kim, Byung-Mun;Lee, Sang-Min;Park, Young-Ja;Hong, Jae-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.385-394
    • /
    • 2021
  • In this paper, a new equation of electromagnetic wave transmission matrix was proposed to calculate the reflected power and transmitted power for the multi-layered planar lossy structure. The applied human leg was modeled as a four-layer planar structure of skin, fat, muscle and bone. The complex dielectric constant to consider the loss of each of these layers was calculated using the 4-pole cole-cole model parameter. When electromagnetic waves were incident on the skin surface, total reflected and transmitted power, and human body loss were calculated for a frequency band of 0.1 to 20.0 GHz. And for various muscle thicknesses, the power reflected only from the outermost bone and re-radiated from the skin was calculated. It was confirmed that at the muscle thickness of 3.0 mm and the frequency of 4.6 GHz the return loss was -6.13 dB, which was 3.42 dB lower than the average value.

Characteristic PCS of Inverter by Boost Converter of PV Generation (태양광 발전 부스트 컨버터를 이용한 인버터 PCS 특성)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Oh, Sang-hak
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.654-664
    • /
    • 2018
  • In this paper, this system is operated by PCS that is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. it can cause the effect of energy saving of electric power, from 10 to 20%. and through a normal operation of electric energy storage system (EESS). In addition, better output waveform was generated because of pulse width modulation (PWM) method, and it was Proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

Synthesis and Properties of Y0.08Sr0.92Fe0.3Ti0.7O3 as Ceramic Anode for SOFC (SOFC의 세라믹 음극물질로서 Y0.08Sr0.92Fe0.3Ti0.7O3의 합성 및 물성 평가)

  • Lee, Tae-Hee;Jeon, Sang-Yun;Im, Ha-Ni;Song, Sung-Ju
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.161-165
    • /
    • 2021
  • In general, SOFCs mainly use Ni-YSZ cermet, a mixture of Ni and YSZ, as an anode material, which is stable in a high-temperature reducing atmosphere. However, when SOFCs have operated at a high temperature for a long time, the structural change of Ni occurs and it results in the problem of reducing durability and efficiency. Accordingly, a development of a new anode material that can replace existing nickel and exhibits similar performance is in progress. In this study, SrTiO3, which is a perovskite-based mixed conductor and one of the candidate materials, was used. In order to increase the electrical conduction properties, Y0.08Sr0.92Fe0.3Ti0.7O3, doped with 0.08 mol of Y3+ in Sr-site and 0.03 mol of transition metal Fe3+ in Ti-site, was synthesized and its chemical diffusion coefficient and reaction constant were measured. Its electrical conductivity changes were also observed while changing the oxygen partial pressure at a constant temperature. The performance as a candidate electrode material was verified by predicting the defect area through the electrical conductivity pattern according to the oxygen partial pressure.