• 제목/요약/키워드: constant power

Search Result 2,851, Processing Time 0.034 seconds

A Study on the Secondary Optimization Analysis based on the Result of Primary Structure Analysis for the Die Thickness (금형두께에 대한 1차 구조해석 결과를 기반으로 한 2차 최적화 해석에 관한 연구)

  • Lee, Jong-Bae;Kim, Sang-Hyun;Woo, Chang-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3448-3454
    • /
    • 2014
  • Generally existing structure analysis was applied to elastic analysis basically in practice. Considering the nonlinear material and the nonlinear geometric to be a more precise analysis, for this reason, The necessity for a structual analysis have been constantly required. Therefore, after optimization is performed, designed a simple model which is applied the principle of nonlinear in this study, a structural analysis of existing experienced users, have a aims at presenting theory and a method in order to perform anyone the analysis easily. In this study, the proposed model applied to die ribs, Regarding the shear load, less strain and stress was generated but strength was sufficient. The initial strain and stress was reconfigured to fit the size and shape, A hyperstudy in conjunction with Abaqus with nonlinear structural analysis, revealed an acceptable maximum and minimum range of stress and under the conditions of minimum strain, the plate made with a constant increment. In the experimental models, the plate thickness was given a power of 40 Newton, according to the thickness of the press die through an iterative process. When the stress and strain was applied to the die thickness, 7-8mm thickness could be obtained by optimizing.

Characteristic Analysis of Permanent Magnet Linear Generator by using Space Harmonic Method (공간고조파법을 이용한 영구자석 선형 발전기의 특성 해석)

  • Seo, Seong-Won;Choi, Jang-Young;Kim, Il-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.688-695
    • /
    • 2017
  • This paper deals with characteristics analysis of a permanent magnet (PM) linear generator using analytical methods for wave energy harvesting. The wave energy is carried out from the movement of a yo-yo system. A linear generator using permanent magnets to generate a magnetic force itself does not require a separate power supply and has the advantage of simple maintenance. In addition to the use of a rare earth, a permanent magnet having a high-energy density can be miniaturized and lightweight, and can obtain high energy-conversion efficiency. We derived magnetic field solutions produced by the permanent magnet and armature reaction based on 2D polar coordinates and magnetic vector potential. Induced voltage is obtained via arbitrary sinusoidal input. In addition, electrical parameters are obtained, such as back-EMF constant, resistance, and self- and mutual-winding inductances. The space harmonic method used in this paper is confirmed by comparing it with finite element method (FEM) results. These facilitate the characterization of the PM-type linear generator and provide a basis for comparative studies, design optimization, and machine dynamic modeling.

Studies on the Extraction Rate of Oil from Sardine, Sardinops melanosticta (정어리 지질의 추출속도에 관한 연구)

  • YANG Hyun-Seok;LEE Keun-Tai;BYUN Dae-Seok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.1
    • /
    • pp.40-46
    • /
    • 1984
  • The extraction ratio of oil using solvent from the muscle of sardine, Sardinops melanosticta, was studied. The results were critically evaluated in the light of the theory of oil diffusion in a porous solid model. In addition the effect of temperature and moisture on the extraction rate was examined. Sardine muscle was prepared in a manner to meet the conditions required by the diffusion theory from Fick's law. The results of the model were well coincidenced to the theory derived from Fick's law. Diffusion constants at the direction to muscle fiber($D_1$) and at direction perpendicular to fiber($D_2=D_3$) when extracted at $45^{\circ}C$ were $8.16{\times}10^{-8}cm^2/sec\;and\;4.12{\times}10^{-8}cm^2/sec$, respectivly. The extraction rate was linearly propotional to absolute temperature(T) by eleventh power under the constant condition of moisture contents and muscle size. A comparison of the experiments with the highest($74.22\%$) and the lowest ($32.48\%$) moisture indicated that difference of $1\%$ in moisture contents caused to change the slope(K) of the extraction curve $0.53{\times}10^{-6}sec^{-1}$ approximately.

  • PDF

A Study on the Manufacturing, Mechanical Properties,Abrasion Resistance, and Slow Crack Growth Resistance of the Recycled Polyethylene/Fly Ash Composites (재생 폴리에틸렌/비산회 분말 충전 복합체 제조와 기계적 물성, 내마모성 및 저속균열성장 저항성에 관한 연구)

  • Kye, Hyoung-San;Shin, Kyung-Chul
    • Elastomers and Composites
    • /
    • v.46 no.4
    • /
    • pp.335-342
    • /
    • 2011
  • The virgin and recycled polyethylene composites with various ratio of fly ash were manufactured by using a fully intermeshing co-rotating twin screw extruder for the reuse of fly ash from power plant and post-consumed polyethylene. Fly ash were blended with virgin HDPE and recycled polyethylene at the weight fraction of 0 to 40 wt.%. Mechanical properties such as yield strength, abrasion resistance, and slow crack resistance were measured with ISO and ASTM standards. The experimental results for the various composites showed that the elongation at break and the yield stress of the composites decreased with increasing fly ash contents. Generally, the abrasion resistance of PEs decreased with increasing sandpaper grits but the abrasion resistance of the composites increased with fly ash content at finer abrasive surface. The slow crack growth resistance of virgin HDPE, recycled JRPE and the JRPE composite showed higher slow crack growth resistance up to 50% of load at notch depth of 20% and 30%, but KRPE and the KRPE composite showed much lower resistance than virgin HDPE, JRPE and the JRPE composite. Time to break, measured with NCLS test method, of all PEs and the composites satisfies the regulation of Korean Industrial Specification for sewer pipe and support application.

A STUDY ON THE EFFECT OF ORTHODONTIC FORCES AND EXOGENOUS ELECTRIC CURRENTS ON $PGE_2$ CONTNET OF ALVEOLAR BONE IN CATS (교정력 및 외인성 전류가 고양이 치조골의 prostaglandin $E_2$에 미치는 영향에 관한 연구)

  • Kim, Jong-Tae;Kim, Joong-Soo;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.203-215
    • /
    • 1984
  • This experiment was performed to explore the effect of electric currents and orthodontic forces on bone $PGE_2$ content and orthodontic tooth movement on cats. Stainless steel electrodes were connected a power pack consisting of five miniature batteries, a transistor, and a resistor. The current $(10{\pm}2{\mu}A)$ was provided by a constant source encased in a palatal acrylic plate. In first experiment, the cathode was placed mesial to the right maxillary canine tooth and the anode was positioned distal to the tooth, Sham electrodes were placed new the left cuspid, to serve as control. Nine cats were divided into three groups evenly. Groups of three animals were treated with electric currents only-for 1, 3 and 7 days, respectively. In second experiment, electric currents and the orthodontic forces of about 80 gm were applied to the right maxillary canine, and the orthodontic forces only were applied to the left maxillary canine. 3 groups of three cats each were treated in this experiment-for 1, 3 and 7 days, respectively. Alveolar bone samples were obtained from sites of tension and compression as well as from contralateral sites. Bone samples were extracted by homogenization in $40\%$ ethanal. The supernatant partitioned twice with 2 volumes of petroleum ether to remove neutral lipids and the aqueous supernatant partitioned in ethyl acetate. After drying the solvent, $PGE_2$ was measured by radioimmunoassay technique. The obtained results were as follows. 1. Teeth treated with combined force and electricity moved faster than those treated with force alone. 2. Alveolar bone $PGE_2$ content of electric stimulation was increased at both electrodes. 3. Alveolar bone $PGE_2$ content of mechanical stimulation at compression sites was gradually increased at all time period. At tension site, $PGE_2$ content increased after 1 day of mechanical stimulation remained elevated at all time period. 4. Alveolar bone $PGE_2$ content of compression sites was increased more than that of tension sites from mechanical stimulation as well as electrical stimulation.

  • PDF

Formation Constants of 18-Crown-6 Complexes with Substituted Potassium Phenoxides (置換 Potassium phenoxide와 이루는 18-Crown-6 Complex의 形成常數)

  • Soo-Dong Yoh;Soon-Kyoo Kim;In-Sook Han;Jong-Hwan Park
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.53-59
    • /
    • 1988
  • Recently, the formation of the complexes between macrocyclic polyethers and alkali metal salts have been determined by several methods. It has been suggested that the specificity of the complexation be due to the nature of the surrounding solvent molecules. The formation constant values ($K_f$) of $K^+$ are shown to be the largest among the other alkali metal cations because the ionic diameter of $K^+$ is approximately the same with the hole size of 18-crown-6. In this study the formation constants of the 1 : 1 complexes of 18-crown-6 with potassium p-substituted phenoxide are calculated by the conductance measurement in organic solvents. As a result, the $K_f$ value series among organic solvents are given in the order of $CH_3$OH > DMF > DMSO. It seems that the donor number of the solvent is a main factor in the formation of the complex between $K^+$ metal ion and 18-crown-6 molecules. At the same time, the formation constants increase with increasing the electron-withdrawing power of substituents because the phenoxide ion is stabilized by the charge dispersion.

  • PDF

Supercritical Fluid Dyeing of Polyester Fiber with Two Different Dispersion Dyes (두 종류의 분산염료를 이용한 폴리에스테르 섬유의 초임계유체 염색)

  • Jung, In-Il;Lee, Sang-Yun;Lim, Gio-Bin;Ryu, Jong-Hoon
    • Clean Technology
    • /
    • v.17 no.2
    • /
    • pp.110-116
    • /
    • 2011
  • The dyeing of polyester fiber with two different disperse dyes (Disperse Red 60 and Disperse Yellow 54) was carried out using supercritical carbon dioxide ($SCCO_2$) as a dyeing medium at temperatures ranging from $50^{\circ}C$ to $90^{\circ}C$ and at pressures from 15 MPa to 30 MPa. The dye uptake of Disperse Red 60 on polyester fiber was found to increase with temperature at constant pressure and $SCCO_2$ density (700 kg/$m^3$). At $90^{\circ}C$ and 30 MPa, the dye uptake on polyester fiber increased with dyeing time and the saturation concentration of Red 60 was attained within 240 min, while a longer dyeing time was required for Yellow 54 to reach its saturation concentration. When dyestuff mixtures with mixing ratios of 0.01 to 9.0 (Red 60/Yellow 54) were used, the uptake ratio of the two dyes was found to be proportional to 0.26 power of their mixing ratio. Dyed fibers showed an orange color and the depth of the color depended upon the mixing ratio of the dyestuffs.

Growth of CdS thin film using hot wall epitaxy method and their photoconductive characteristics (HWE 방법에 의한 CdS 박막의 성장과 광전도 특성)

  • 홍광준
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.3
    • /
    • pp.341-350
    • /
    • 1996
  • The CdS thin films are grown on quartz plate by hot wall epitaxy. The source and substrate temperature is $590^{\circ}C$ and $400^{\circ}C$ respectively, and thickness of the film is $2.5\;\mu\textrm{m}$. Using extrapolation method of X-ray diffraction patterns for the CdS thin film, it was found hexagonal structure whose lattice constant a and c were $4.137\;{\AA}$ and $6.713\;{\AA}$, respectively. Hall effect on this sample was measured by the method of van der Pauw and studied on cattirer density and mobility depending on temperature. From hall data, the mobility was likely to be decreased by piezoelectric scattering in the temperature range 30 K to 200 K and by polar optical scattering in the temperature range 200 K to 293 K. In order to explore the applicability as a photoconductive cell we measured the sensitivity ($\gamma$), the ratio of photocurrent to darkcurrent (pc/dc), maximum allowable power dissipation (MAPD), spectral response and response time. The results indicated that for the samples annealed in Cu vapor the photoconductive characteristics are the best. Then we obtained the sensitivity of 0.99, the value of pc/dc of $9.42{\times}10^{6}$, the MAPD of 318 mW, and the rise and decay time of 10 ms and 9 ms, respectively.

  • PDF

A Study on the Pyroelectric Properties of PZT(30/70) Thick film Prepared by Using 1,3 Propanediol (1,3 Propanediol을 이용해 제작된 PZT(30/70) 후막의 초전특성에 관한 연구)

  • Song, Kum-Suck;Chang, Dong-Hoon;Joung, Yang-Hee;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.6
    • /
    • pp.9-15
    • /
    • 2004
  • PZT(30/70) thick film was fabricated by using 1,3 propanediol-based sol-gel method. Prepared film of pyroelectric property was investigated by Dynamic method of modulation frequency dependence. Pyroelectric coefficient was obtained about $5.0{\times}10^{-8}\;C/cm^2{\cdot}K$. The figure of merits for voltage responsively and specific detectivity were $3.4{\times}10^{-11}\;C{\cdot}cm/J$ and $5.9{\times}10^{-9}\;C{\cdot}cm/J$, respectively, because of relative high-dielectric constant and high-pyroelectric coefficient. Voltage responsively was increased at low modulation frequency and it was decreased at high modulation frequency. Voltage responsively was maximum 1.84 V/W at 10Hz. As Johnson noise is dominant, Noise voltage was increased nearly proportional to $f^{-1/2}$. Noise equivalent power and specific detectivity were $2.83{\times}10^{-7}\;W/Hz^{1/2}$ and 3.13{\times}10^5\;cm{\cdot}Hz^{1/2}/W$ the same frequency at 80Hz, respectively.

Gracilis Muscle Transplantation in Neglected Brachial Plexus Palsy (진구성 상완 신경총 마비에 대한 유리박근이식술)

  • Chung, Duke-Whan;Han, Chung-Soo;Ok, Jae-Chul;Cho, Chang-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.73-79
    • /
    • 1997
  • Complete denervation after severe brachial plexus injury make significant muscle atrophy with loss of proper function. It is much helpful to reconstruct the essential function of the elbow flexion movement in patient with total loss of elbow flexion motion after brachial plexus lesion which was not recovered with nerve surgery or long term conservative treatment from onset. In whole arm type brachial plexus injury, if there were no response to neurotization or neglected from injury, the volume of the denervated muscle is significantely reduced month by month. About 18 months most of the muscle fibers change to fibrous tissues and markedly atrophied irreversibly, further waiting is no more meaningful from that period. Authors performed 14 cases of functioning gracilis muscle transfer from 1981 to 1995 with microneurovascular technique, neuromusculocutaneous free flaps were performed for reconstruction of lost elbow flexion function. Average follow-up period was 5 years and 6 months. We used couple of intercostal nerves as a recipient nerve which were anastomosed to muscular nerve from obturator nerve in all cases. Recipient vessels were three deep brachial artery and eleven brachial artery which were anastomosed to medial femoral circumflex artery with end to end or end to side fashion. Average resting length of the transplanted gracilis were 24 cm. We can get average 54 degree flexion range of elbow with fair muscle power from flail elbow. There were one case of muscle necrosis with lately developed thrombosis of microvascular anastomosed site which comes from insufficient recipient arterial condition, 3 cases of partial marginal necrosis of distal skin of the transplanted part which were not significant problem with spontaneously solved with time goes by gracilis muscle has constant neurovascular pattern with relatively easy harvesting donor with minimal donor morbidity. Especially it has similar length and shape with biceps brachii muscle of upper arm and longer nerve pedicle which can neurorrhaphy with intercostal nerve without nerve graft if sufficient mobilization of the nerves from both sides of gracilis and intercostal region. Authors can propose gracilis muscle transplantation with intercostal nerves neurotization is helpful method with minimal donor morbidity for neglected brachial plexus palsy patients.

  • PDF