• Title/Summary/Keyword: constant power

Search Result 2,851, Processing Time 0.033 seconds

Evaluation of self-heating propensity and its relation with fuel properties of various coals (다양한 탄종별 자체발열 특성과 물성의 비교 분석)

  • Kim, Jungsoo;Lee, Yongwoon;Im, Hyeon Soo;Park, Hoyoung;Ryu, Changkook
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.83-85
    • /
    • 2013
  • With an increase in the use of low rank coals in power plants, various operational issues were raised in the fuel storage and supply, combustion, boiler and flue gas treatment systems. In the fuel storage and supply system, the main issue is the self-heating propensity of low rank coals leading to spontaneous combustion in yard storage, transport and pulverization. This study evaluated the reactivity of various sub-bituminous and bituminous coals with oxygen at low temperatures by analyzing the temperature increase characteristics of coals under a constant flow rate of oxygen supply. The results were quantified to a self-heating index and the relation with the fuel properties were evaluated.

  • PDF

Induction Motor Speed Control System using Two Phase SRPP-PWM Scheme (2상 SRPP-PWM 기법을 사용한 유도모터 속도제어 시스템)

  • Wi Seog-Oh;Kim Jung-Kun;Lim Young-Cheol;Jung Young-Gook
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.25-28
    • /
    • 2002
  • In this paper, 2 phase modulated SRPP-PWM(Separately Random Pulse Position PWM) is proposed. This PWM technique is based on the 2 phase modulated SVPWM(Space Vector Pulse Width Modulation). In according to the theory of SVPWM, 2 phase modulated SVPWM uses two pulses, not three pulses as in 3 phase modulated SVPWM. In the proposed SRPP-PWM scheme, each of two phase pulses is located randomly in each switching interval. The experimental results show that the voltage and switching noise harmonics are spread to a wide band area. Also, the performance of the proposed 2 phase modulated SRPP-PWM and the conventional SVPWM are compared to each other In result, the speed response is nearly similar to each other from the viewpoint of the v/f constant control.

  • PDF

Characteristics Analysis According to Switching of Switched Reluctance Generator (스위치드 릴럭턴스 발전기의 스위칭에 따른 특성)

  • Oh, Jae-Seok;Oh, Ju-Hwan;Kwon, Byung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1356-1361
    • /
    • 2008
  • A switched reluctance generator(SRG) has simple magnetic structure, and needs simple power electronic driving circuit. But, a SRG are no windings or permanent magnets on the rotor, and there are concentrated windings placed around each salient pole on the stator. Because of the characteristics of time-sharing excitation, the control of SRG is very flexible. And there are several parameters for controlling SRG, such as switch turn-on angle, switch turn-off angle, and exciting voltage and controlling mode, all these will affect the generation greatly. A SRG has positive torque at increasing inductance region and negative torque at decreasing inductance region. In this paper, we studied characteristics about the switch turn-on and off angles according to switch method for constant output voltage of the fixed speed SRG. It is the acoustic noise and torque ripple characteristics. Characteristics for a switch angle and method are presented by experiment using a 50W SRG with 12/8 poles.

Scheduling of Preventive Maintenance for Generating Unit Considering Condition of System (시스템의 상태를 고려한 발전설비의 예방 유지보수 계획 수립)

  • Shin, Jun-Seok;Byeon, Yoong-Tae;Kim, Jin-O;Kim, Hyung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1305-1310
    • /
    • 2008
  • Traditional maintenance planning is based on a constant maintenance interval for equipment life. In order to consider economic aspect for time based preventive maintenance, preventive maintenance is desirable to be scheduled by RCM(Reliability-Centered Maintenance) evaluation. The main objective of RCM is to reduce the maintenance cost, by focusing on the most important functions of the system and avoiding or removing maintenance actions that are not strictly necessary. So, Markov state model is utilized considering stochastic state in RCM. In this paper, a Markov state model which can be used for scheduling and optimization of maintenance is presented. The deterioration process of system condition is modeled by the stepwise Markov model in detail. Also, because the system is not continuously monitored, the inspection is considered. In case study, simulation results about RCM will be shown using the real historical data of combustion turbine generating unit in Korean power systems.

Phase Shift Analysis and Phase Identification for Distribution System with 3-Phase Unbalanced Constant Current Loads

  • Byun, Hee-Jung;Shon, Sugoog
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.729-736
    • /
    • 2013
  • Power grids are large complicated networks in use around. An absolute phase value for a particular unknown-phase line at a local site should be identified for the operation and management of a 3-phase distribution network. The phase shift for a specific point in the line, as compared with a phase reference point at a substation, must be within a range of ${\pm}60^{\circ}$ for correct identification. However, the phase shift at a particular point can fluctuate depending on the line constants, transformer wiring method, line length, and line amperage, etc. Conducted in this study is a theoretical formulation for the determination of phase at a specific point in the line, Simulink modeling, and analysis for a distribution network. In particular, through evaluating the effects of unbalanced current loads, the limitations of the present phase identification methods are described.

Study of reflection rate character of anodized aluminum thin film (알루미늄 양극산화피막의 반사율 특성연구)

  • Kim, Seung-Kyum;Kim, Dong-Hyun;Joo, In-Joong;Nam, In-Tak;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.227-232
    • /
    • 2003
  • Anodizing film was prepared by anodic oxidation of pure aluminum(purity > 99.50) using DC power supply for constant current mode in an electrolytic solution of surface of sulfuric acid. Effects of pre-treatment process such as chemical polishing, acid cleaning, alkali etching before anodic oxidation, were studied to microstructures and surface morphologies. A roughness on surface of anodizing film had to be decreased for amorphous phase by anodic oxidation. A roughness on surface of anodizing film decrease as annealing temperature increased in chemical polishing.

  • PDF

A Parallel Resonant inverter linked type DC-DC Converter with active-c1amp circuits (능동클램프회로를 갖는 병렬공전 인버터 링크형 DC-DC 컨버터)

  • 오경섭;남승식;김동희;김희대;선우영호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.311-314
    • /
    • 2003
  • In this paper, proposed circuit proposes that Active-Clamp-Circuits basis of a current-fed inverter linked type high frequency resonant dc-dc converter of conventional. and the paper the most of characteristics of the reduced high voltage stress main switches with active clamp circuits and output current constant with the resonant part consists of L, C resonant tank circuit. Also, the capacitor (C$_1$, C$_2$) connected in switches are a common using by resonance capacitor and ZVS capacitor. and circuit analysis used state equation of each part modes. Also we conform a rightfulness theoretical analysis by comparing a parameters values and simulation values obtained from simulation using Power MOS-FET as switching devices.

  • PDF

DC Power Supply for Constant Current Drive of LED Backlight Module (LED 백라이트 모듈의 정전류 구동 전원공급 장치)

  • Yoo, Doo-Hee;Park, Jong-Moon;Jeong, Gang-Youl
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.349-352
    • /
    • 2010
  • 본 논문은 LCD LED 백라이트의 정전류 구동 전원공급 장치를 제안한다. 백라이트로 이용되는 LED의 밝기는 LED로 흐르는 전류에 거의 선형적으로 비례하기 때문에 일정한 밝기를 얻기 위해서는 LED에 정전류가 공급되어야 한다. 제안된 전원공급 장치는 구현이 용이하며 간단한 LED 전류제어 방식을 이용하였으며, 200V의 직류 최대 출력전압과 20W의 최대출력전력을 가진다. 그리고 제안된 회로는 컴퓨터 시뮬레이션을 통하여 회로 동작의 정확함을 보인다.

  • PDF

The study of interleaved flyback converter for LED Constant-current control (LED 정전류 제어를 위한 인터리브드 플라이백 컨버터의 연구)

  • Kim, Hyo-Seon;Song, Gwang-Seok;Kim, Seung-Ae;Kim, Tae-Hun;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.588-589
    • /
    • 2012
  • 최근 LED 드라이버의 효율 향상에 집중될수록 LED의 특성을 고려한 정전류 제어가 더욱 중요해지고 있다. 본 논문에서는 LED 모듈과 같은 정전류 제어가 필요한 부하에 플라이백 컨버터의 병렬구조 연결에 의한 정전류 공급법에 대해 제안한다. 플라이백 컨버터를 병렬구조로 연결하고 전류 불연속 모드 상태에서 스위칭 소자에 PWM 신호를 교차 인가하고, 또한 싱글 스테이지의 전력변환을 함으로써 시스템 효율을 개선하였다. 더불어 병렬구조로 연결된 플라이백 컨버터의 변압기를 통합하여 설계함으로써 코어의 부피, 비용 및 출력 리플 저감의 효과를 가능하게 하였다. 제안된 알고리즘 및 시스템에 대해서 시뮬레이션을 통해 그 타당성을 검증하였다.

  • PDF

The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality (전압품질이 저압 전기기기 운전에 미치는 특성연구)

  • Park, In-Deok;Lee, Geun-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.33-35
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF