• Title/Summary/Keyword: constant output

Search Result 1,067, Processing Time 0.026 seconds

Power Sharing Method for a Grid connected Microgrid with Multiple Distributed Generators

  • Nguyen, Khanh-Loc;Won, Dong-Jun;Ahn, Seon-Ju;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.459-467
    • /
    • 2012
  • In this paper, a grid connected microgrid with multiple inverter-based distributed generators (DGs) is considered. DG in FFC mode regulates the microgrid as a controllable load from the utility point of view as long as its output is within the capacity limit. The transition mode causes a change in frequency of microgrid due to the loss of power transferred between main grid and microgrid. Frequency deviation from the nominal value can exceed the limit if the loss of power is large enough. This paper presents a coordinated control method for inverter-based DGs so that the microgrid is always regulated as a constant load from the utility viewpoint during grid connected mode, and the frequency deviation in the transition mode is minimized. DGs can share the load by changing their control modes between UPC and FFC and stabilize microgrid during transition.

Hybrid position/force control in the same direction for assembly operation in variable friction environment (마찰이 있는 조립작업을 위한 동일 방향 혼합위치/힘 제어)

  • 김상연;권동수;김문상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.253-256
    • /
    • 1997
  • This paper proposes a control strategy of position and force control in the same direction based on hybrid position/force control. In order to control position and force in the same direction, a weighting matrix is introduced instead of a selection matrix suggested by Raibert and Craig. The major part of the controller output comes from the position controller when a position control error is large, from the force controller when a position control error is large. The proposed algorithm is implemented by the simulation and experiment focusing on the peg-in-hole task where friction exist significantly and is not constant. It also adopts and event control scheme for more efficient performance.

  • PDF

Improved the Noise Immunity of Phase-Locked Loop

  • Intachot, Terdsak;Panaudomsup, Sumit;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1643-1647
    • /
    • 2003
  • This paper, we propose a new high noise immunity phase-locked loop(PLL) which can suppress the high incident noise coupling with large amplitude and long period to the input frequency of PLL and keeps constant frequency and phase of the VCO output for providing the high stability distribution clock pulse.

  • PDF

Study on Thermal Analysis for Optimization LED Driver ICs

  • Chung, Hun-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.59-61
    • /
    • 2017
  • This research was analyzed thermal characteristics that was appointed disadvantage when smart LED driver ICs was packaged and we applied extracted thermal characteristics for optimal layout design. We confirmed reliability of smart LED driver ICs package without additional heat sink. If the package is not heat sink, we are possible to minimize package. For extracting thermal loss due to overshoot current, we increased driver current by two and three times. As a result of experiment, we obtained 22 mW and 49.5 mW thermal loss. And we obtained optimal data of 350 mA driver current. It is important to distance between power MOSFET and driver ICs. If the distance was increased, the temperature of package was decreased. And so we obtained optimal data of 3.7 mm distance between power MOSFET and driver ICs. Finally, we fabricated real package and we analyzed the electrical characteristics. We obtained constant 35 V output voltage and 80% efficiency.

Multiple-Load Induction Cooking Application with Three-Leg Inverter Configuration

  • Sharath Kumar, P.;Vishwanathan, N.;Murthy, Bhagwan K.
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1392-1401
    • /
    • 2015
  • Inverter configurations for multiple-load induction cooking applications need development. Inverter configurations for induction cooking applications are used in home appliances based on single coil inverters. For multiple-load configurations, multiple coils are used. They require proper inverters, which provide independent control for each load and have fewer components. This paper presents a three-leg inverter configuration for three load induction cooking applications. Each induction coil powers one induction cooking load. This configuration operates with constant switching frequency and powers individual loads. The output power of the required load is controlled with a phase-shift control technique. This configuration is simulated and experimentally tested with three induction loads. The simulation and experimental results are in good agreement. This configuration can be extended to more loads.

Single-Phase Z-Source Electronic Transformer with AC and DC Output Voltages (직류출력과 교류출력을 갖는 단상 Z-소스 전자변압기)

  • Yoo, Dae-Hyun;Eom, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.25-26
    • /
    • 2013
  • 본 논문에서는 직류출력과 교류출력을 갖는 단상 Z-소스 전자변압기를 제안하였다. 제안된 시스템은 입력은 병렬로, 츨력은 직렬로 연결된 2대의 Quasi Z-소스 AC-AC 컨버터로 구성되어 있다. 교류 입력 전압에 대하여 Quasi Z-소스 AC-AC 컨버터의 출력 전압은 동상의 강압과 승압 고정 주파수 가변 전압 VVCF(Variable Voltage Constant Frequency)의 특성을 가지고 있다. 또한 Quasi Z-소스 AC-AC 컨버터의 Active 스위치 단에 벅-컨버터를 연결하여 48V 직류 전압도 동시에 출력 할 수 있다. 끝으로 PI제어된 직류 벅 컨버터에 의하여 일정한 직류전압을 출력할 수 있음을 PSIM 시뮬레이션과 실험을 통하여 확인하였다.

  • PDF

A Study of the Device Development for the Contamination Detection in the Delivery Line (유체배관 오염 검출장치 개발에 관한 연구)

  • Jeong, Yi Ha;Kim, Byung Han;Hong, Joo-Pyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.1
    • /
    • pp.45-49
    • /
    • 2015
  • Process gases with vapor or liquid phase as well as gas phase may experience alteration in itself or be contaminated in the fluid pipe to the process chamber. And thus it result in as particles or defects on the substrates in semiconductor, LCD, LED manufacturing. Purifiers and filters are used for control of contamination. However, none of detection device is available in the delivery line. In this paper, we propose simple device with lighting and sensing in order to predict contamination of the fluid or the tube wall. For some general purpose gases, it showed constant voltage output regardless of the flow rates. But, the smoke and the moisture in the air lowered the figure due to its concentration. Numerical values for several solid and liquid media were obtained. And, the operating temperature tendency was investigated.

FLC-MPPT Photovoltaic System for Induction Motor Drive (유도전동기 드라이브를 위한 FLC-MPPT 태양광 발전시스템)

  • Choi, Jung-Sik;Ko, Jae-Sub;Jung, Byung-Jin;Kim, Do-Yeon;Park, Ki-Tae;Choi, Jung-Hoon;Chung, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.301-305
    • /
    • 2007
  • This paper is proposed by fuzzy-based MPPT control of photovoltaic to drive induction motor. Design and prototype implement of a fuzzy logic(FL) controller for maxim]m power extraction from a stand-alon photovoltaic Is proposed in this paper. Error and the change of error between maximum power and real power are used by input of fuzzy controller. Moreover, it output changing of voltage from control constant. The validity of this paper is proved by comparing maximum power point tracking and performance of motor drive through comparison fuzzy and PI of tradition method.

  • PDF

A Study of Ballst for Fluorescent Lamp using DC power source (직류 전원을 사용하는 형광등용 안정기 연구)

  • Han, Soo-Bin;Park, Suck-In;Song, Eu-Gine;Jeoung, Hak-Guen;Jeong, Bong-Man;You, Seung-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.131-133
    • /
    • 2007
  • In a design of DC ballast for fluorescent lamp, pre-stage of DC-DC converter is required to keep the constant output lumen performance regardless of variable DC input voltage. In this paper, flyback topology is used for optimum performance of 32W lamp, and various important design points for successful operation over the whole operating range are described.

  • PDF

Charge/Discharge System for Small Scaled Photovoltaics using Microprocessor (마이크로프로세서를 이용한 소형 태양광발전용 충방전시스템)

  • Moon, E.A.;Kim, B.H.;Jeong, N.I.;Piao, Z.G.;Cho, Y.O.;Cho, G.B.
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.199-201
    • /
    • 2008
  • This paper persents charge/discharge system for small PV using micro-processor. Charge/discharge system designs a Buck converter and using constant voltage charge system because regular voltage is rather high a condenser. Besides, we did compensate for charge voltage of condenser through a temperature compensation circuit. We consists of a 170W stand-alone PV system to observe charge/discharge system character. In the result of search about output character we know that charge and discharge are smoothly running.

  • PDF