• Title/Summary/Keyword: constant output

Search Result 1,067, Processing Time 0.029 seconds

On-Line Identification Algorithm of Unknown Linear Systems (미지의 선형 시스템에 대한 On-Line 모델링 알고리즘)

  • 최수일;김병국
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.4
    • /
    • pp.48-54
    • /
    • 1994
  • A recursive on-line algorithm with orthogonal ARMA identification is proposed for linear systems with unkonwn time delay, order, and parameters. The algorithm is based on the Gram-Schmidt orthogonalization of basis functions, and extendedto recursive form by using two dimensional autocorrelations and crosscorrelations of input and output with constant data length. The proposed algorith can cope with slowly time-varying or order-varying delayed system. Various simulations reveal the performance of the algorithm.

  • PDF

Modeling of The Ni-MH Battery Source and Development of The Charger.Discharger System (Ni-MH 전지전원의 모델링과 충.방전 장치 개발)

  • 김광헌;허민호;박영수;안재영;양승학;이일기
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.433-437
    • /
    • 1998
  • Equalize SOC of the cell which effect on the charge.discharge ability and the efficiency of the battery, through the charge.discharge characteristic test of the battery source, and develope the high efficiency charge.discharge system in the series HEV have a constant engine-generator output. For this, in this paper, establish the electrical model and the condition of high efficiency charge.discharge, and proposed the improvement method of charge.discharge characteristic in the battery source that consist of twenty Ni-MH cells connected serial/parallel

  • PDF

A MODEL FOR MYOELECTRIC SIGNAL WITH LOCALIZED MUSCLE FATIGUING

  • Lee, Y.S.;Jeon, C.J.;Lee, S.H.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.7 no.1
    • /
    • pp.79-86
    • /
    • 2003
  • A myoelectric signal, under sustained isometric contraction of muscle the modelled as the output of a linear time-varying system whose input is constant number of pulse train. The proposed model considered localized muscle fatigue by metabolic by-products during sustained fatiguing contraction. To characterize muscle fatiguing model of myoelectric signal, We calculated median frequency of generated signal as fatiguing index of muscle during sustained isometric contraction.

  • PDF

The development of laser system for cancer (암치료용 레이저 시스템 개발)

  • 이동진;김주명;김선학;임현수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.08a
    • /
    • pp.154-155
    • /
    • 2001
  • A laser system for therapy of cancer is proposed in this paper. In order to accuracy and statistical output control we used the constant current control method and designed the power source to protect the resonator from the over -current, rush-current and electrical fault. The most important things are the radiation type for cancer therapy in laser system, we developed the radiation type of cw, pulse, and burst pulse. The experimental result show that laser beam power increase linearly from 100mW to 300mW for input current increasing and the exposure time.

  • PDF

Development of Simulator for AC Traction Power Supply System (교류 급전시스템 해석을 위한 윈도우즈 기반 시뮬레이터 개발)

  • Kim, Joo-Rak;Lee, Chang-Mu;Chang, Sang-Hoon;Kim, Jung-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.411-417
    • /
    • 2009
  • This paper describes the development of integrated simulator for traction power supply system with GUI (Graphic User Interface). This simulator consists of a lot of calculation modules such as TPS, time table, line constant, and power supply system analysis. Each module has input and output structure respectively. The proposed simulator is tested on both high speed railway line and metropolitan subway line. The test has confirmed the function of the developed simulator.

  • PDF

Analysis of Transistorized Logarithmic Amplifier (트랜지스터 대수증폭기의 해석)

  • 이상배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.6 no.1
    • /
    • pp.19-22
    • /
    • 1969
  • Detailed analysis has been developed concerning the transfer function and stability condition of the logarithmic amplifier using a common emitter transistor as a feed-back element. The analysis shows that input current vs output voltage transfer characteristics is accurately ogarithmic through entire operating current, and the time constant depends on input capcitance and collector-emitter equivalent resistance. Also the minimum value of imput capacitance required to stabilize the system is derived.

  • PDF

Automatic setting of delay time of an occupancy sensor using an adder circuit (인체감지 센서의 시간지연 설정)

  • 정영훈;송상빈;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.162-165
    • /
    • 1998
  • A certain degree of energy saving can be possible by controlling the delay time of occupancy sensor. In this paper a control circuit is designed for automatic control of delay time setting appropriate to different situations using a digital counter, two latches and an adder. The delay time is controlled by adjusting the time constant of RC circuit through on-off control of switching devices according to adder output, which determines the base current level of switching devices. And from PSpice simulation it is verified to function properly.

  • PDF

A control of wound-rotor induction generator for random wave input generation system

  • Kim, Moon-Hwan
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.3
    • /
    • pp.223-228
    • /
    • 2007
  • This paper deals with the secondary excited induction generator applied to random wave input generation system. As it is preferred to stabilize the output voltage and frequency in the constant level, microcomputer controlled CSI connected to the secondary windings supplies the secondary current with slip frequency. For testing this method, the input torque simulator is constructed, according to the power flow analysis. The experimental and numerical results show the advantage of secondary excited induction generator system for the random input wave generation system.

Experimental Research to Improve the Output Characteristic of CDI System (CDI시스템의 출력발생향상을 위한 실험적 연구)

  • 전병실;김종규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.31 no.11
    • /
    • pp.146-154
    • /
    • 1982
  • This paper proposes a new circuit for the CDI system to have a constant ignition power at the engine speed range of 500 to 7500 rpm and the battery voltage range of 12 to 16 volts in the 4-cylinder automobile. The proposed CDI system has a closed-loop with a PWM DC-DC converter controlled by the error signal between capacitor voltage and reference voltage. In order to decrease the capacitor charging time, the primary winding of ignition coil is made to be shorted during capacitor charging. An experimental suystem is fabricated and the results obtained thereof are found to be satisfactory.

A Robust Discrete-Time Adaptive Control with a Compensator (보상기를 이용한 강인한 이산 시간 적응 제어)

  • 이호진;최계근
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.12
    • /
    • pp.1610-1617
    • /
    • 1988
  • In this paper, a robust discrete-time adaptive control with compensation is proposed for single-input single-output discrete-time plants which have unmodeled dynamics. The stability of the overall system is studied using the conic sector stability theorems when a normalized constant gain parameter adaptation algorithm and a properly chosen compensation are used. An illustrative exmple shows that this compensation can also increase the parameter adaptation speed. And a method of compensation using the adaptive observation is also discussed.

  • PDF