• Title/Summary/Keyword: constant output

Search Result 1,067, Processing Time 0.028 seconds

Deducing Improvement Schemes for Public Medical Centers through Annual Progress Analysis (공공의료기관의 효율성 개선방안에 대한 연도별 추이분석)

  • Kim, Yong-Tea;Kim, Yang-Kyun
    • Journal of Korean Society for Quality Management
    • /
    • v.37 no.3
    • /
    • pp.123-139
    • /
    • 2009
  • This study examines the relative efficiency of 34 local public medical centers in Korea. In order to concretely grasp the causes of inefficiency and suggest improvement solutions, the desirable set point was established based on the actual value which needs to be improved. As a result of analysis, we determined that output must be increased while input is held constant in order to improve effectiveness through the actual value and set point. Efficiency cannot be achieved if input is augmented solely to increase output. Also, to increase output, the medical centers need to improve their quality without increasing any input for customer visits and hospitalizations. Further, in order to strategically promote effectiveness and efficiency of local public medical centers, these medical centers must focus on input resource and patient interchange through the mutual cooperation with local private hospitals and university medical centers.

A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter (전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한연구)

  • 장수진;류동균;서민성;김준호;원충연;배기훈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.151-156
    • /
    • 2002
  • The output voltage of Synchronous Generator is regulated constantly by field current control in excitation system. A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the constant output voltage under normal operating conditions about various levels. High frequency PWM converter (Current Mode Control Buck converter) type excitation system for synchronous generator is able to sustain output voltage level properly when the fault condition happened. This paper deals with the design and evaluation of the excitation system controller for a synchronous generator to improve the steady state and transient stability. The simulation and experimental results show that the proposed excitation system is improve the respons time by the AVR(automatic voltage regulator) of 50kW synchronous generator that is applied the current mode control excitation system.

  • PDF

Measurement of Cardiac Output During Treadmill Exercise Using Impedance Cardiography (트래드밀 운동시 임피던스 심장기록법을 이용한 심박출량의 측정)

  • 김덕원;송철규
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.279-284
    • /
    • 1989
  • Measurement of cardiac output during exercise by noninvasive technique is very needed in the area of sports medicine. However there are only two noninvasive techniques, one of which is $CO_2$ subscript rebreathing technique and the other one is impedance cardiography. While $CO_2$ rebreathing technique needs special breathing and metablic steady state, impedance cardiography has motion Uiiau problem. In this study maior sources of the mothion artifact during treadmill exercise was found experimentally to. be the impact caused by each step on the treadmill. Thus special shoes to reduce the impact were developed. These are the shoes with silicon rubber and hard sponge attached to the soles. It was possible to measure cardiac output with the newly developed shoes for Burke protocol whose speed of the treadmill was constant 3.5 miles/hour while it was impossibel with the conventional exercise shoes.

  • PDF

A converting method for square wave to average value in real time (실시간 구형파-평균치 변환 방법)

  • Lee, J.M.;Kim, C.K.;Kim, S.J.;Cheon, J.M.;Park, M.K.;Kwon, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.585-587
    • /
    • 2006
  • Generally, LPF(low pass filter) circuits are used for converting square wave to average value, but these are not used necessary for average value of square wave in real time because of time constant of LPF. This paper deals with acquiring method for average value of square wave in real tine in case of frequency of output voltage is fixed, waveform of output voltage is square wave and duty of output voltage is varied like as 1 quadrant or 4 quadrant chopper.

  • PDF

Coordination Control of ULTC Transformer and STACOM using Kohonen Neural Network (코호넨 신경회로망을 이용한 ULTC 변압기와 STACOM의 협조제어)

  • 김광원;이흥재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1103-1111
    • /
    • 1999
  • STACOM will be utilized to control substation voltage in the near future. Although STACOM shows good voltage regulation performance owing to its rapid and continuous response, it needs additional reactive power compensation device to keep control margin for emergency such as fault. ULTC transformer is one of good candidates. This paper presents a Kohonen Neural Network (KNN) based coordination control scheme of ULTC transformer and STACOM. In this paper, the objective function of the coordination control is minimization of both STACOM output and the number of switchings of ULTC transformer while maintaining substation voltage magnitude to the predefined constant value. This coordination, control is performed based on reactive load trend of the substation and KNN which offers optimal tap position in view of STACOM output minimization. The input variables of KNN are active and reactive power of the substation, current tap position, and current STACOM output. The KNN is trained by effective Iterative Condensed Nearest Neighbor (ICNN) rule. This coordination control applied to IEEE 14 bus system and shows satisfactory results.

  • PDF

Conducted Noise Reduction in Three-Phase Boost Converter using Random (3상 승압형 컨버터에 의한 전도노이즈 감소)

  • Jung, Dong-Hyo;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.79-82
    • /
    • 2003
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. In the switching-mode power converter, the output voltage is generally controlled by varying the duty ratio of main switch. When a converter operates in steady state, duty ratio of the converter is kept constant. So the power of switching noise is concentrated in specific frequencies. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

  • PDF

Analysis of Heat Treatment Process Conditions for Output Characteristics of Permalloy Core on Current Sensors using DOE (실험계획법을 이용한 퍼멀로이 전류 코어 센서의 출력특성에 관한 열처리 공정조건 분석)

  • Kim, Young Shin;Kim, Yoon Sang;Jeon, Euy Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.4
    • /
    • pp.16-23
    • /
    • 2020
  • An electric vehicle operates at high currents and requires real-time monitoring of the entire system for ensuring efficiency and safety of the vehicle. Current sensors are applied to drive the motors, inverters, and battery control systems, and are the key components to ensure constant monitoring of the magnitude and waveforms of the operating current. In this study, a heat treatment process condition to influence the performance of Permalloy current sensors was developed; the correlation between the output capacity, low-temperature characteristics, and high-temperature characteristics of the current sensor was studied; and the process was optimized to meet the required output accuracy and temperature characteristics.

A Stable Model Reference Adaptive Control with a Generalized Adaptive Law (일반화된 적응법칙을 사용한 안정한 기준모델 적응제어)

  • 이호진;최계근
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.8
    • /
    • pp.1167-1177
    • /
    • 1989
  • In this paper, a generalized adaptive law is proposed which uses a rational function type operator for parameter adjustment. To satisfy the passivity condition of the adaptation block, we introduce a constant feedback gain into the adaptation block. This adaptation scheme is applied to the model reference adaptive control of a continuous-time, linear time-invariant, minimum-phase system whose relative degree is 1. We prove the asymptotic stability of the output error of this adaptive system by hyperstability method. It is shown that by digital computer simulations this law can give a better output error transient response in some cases than the conventional gradient adaptive law. And the output error responses for the several types of the proposed adaptation law are examined in the presence of a kind of unmodeled dynamics.

  • PDF

Design of a High Frequency PWM Converter for Synchronous Generator Excitation System (동기발전기 여자시스템용 고주파 PWM 컨버터 설계)

  • Jang Su-Jin;Ryu Dong-Kyun;Won Chung-Yuen;Lee Jin-Kuk;Bae Kee-Hun;Kim Soo-Suck
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.515-518
    • /
    • 2002
  • A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the output voltage constant under normal operating conditions at various levels. The output voltage of Synchronous Generator is regulated constantly by field voltage control in excitation system. High frequency PWM converter (Buck converter) type excitation system for synchronous generator that can sustain prefer output voltage level even at the fault condition happened. The proper operation of the proposed excitation system was verified through the simulations and the experiments.

  • PDF

A study of stable output of solid-state laser through feedback control (Feedback 제어를 통한 고체 레이저의 출력특성 안정화에 관한 연구)

  • Song, K.Y.;Kwak, S.Y.;Hong, J.H.;Noh, K.K.;Kim, W.Y.;Kang, U.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1853-1855
    • /
    • 2002
  • A pulsed Nd:YAG laser is used widely in many applications such as materials processing, communications, military and medical instruments. It is important to control the laser energy in those fields with using a pulsed Nd:YAG laser. In this paper, constant-frequency current resonant half-bridge inverter and feedback control circuit are used to have output stable. This laser power supply is designed and fabri which was isolated. Also, this study is used an one-chip microprocessor, SCR, current transform A stable output of this Nd:YAG laser system investigated. The tested results are described.

  • PDF